SILK PRO IPL Device Luxe Laser Hair Removal User Manual

September 7, 2024
SILK PRO

SILK PRO IPL Device Luxe Laser Hair Removal

Product Information

Specifications

  • Weight: 186g
  • Size: 1248348.5mm

Product Introduction

Packing List: IPL device, Power adapter, User
Manual, Wet razor, Safety goggles.

Diagram of Controls: Air inlet/outlet

Technical Parameters

  • Weight: 186g
  • Size: 1248348.5mm

Functions Introduction

Functions:

  • Skin rejuvenation
  • Hair removal

Product Usage Instructions

Safety Tips

Skin Protection Guidelines:

  • Not suitable for individuals with known skin disorders.
  • Avoid use if you have a skin disease like allergic dermatitis or eczema.
  • If you are photosensitive, this product may not be appropriate.
  • Avoid using this product during menstruation, pregnancy, or lactation.
  • Do not use if you have sunburn.
  • Not suitable for individuals with dark or sunburned skin. Refer to the color contrast card for guidance.
  • Avoid using the product if you have dark or fuscescent nevi (moles).
  • Do not apply to broken skin, scabs, healed wounds, cancerous areas, or hemangiomas.
  • Avoid use on the eyes and any areas with artificial aesthetics, prosthetics, or plastic implants.

Instructions For Use

  1. Use the razor to shave the hair every time before using the device.
  2. If you are sensitive to bright lights, use the safety goggles to protect your eyes when using the device.
  3. Plug in the device using the power adapter (no battery to charge).
  4. Clean the glass window using a medical alcohol wipe before each use.
  5. Power On: Press (not hold) the power button to turn on the device. The green indicator light will stop flashing, and you will hear the system running.

FAQ

Q: Can this product be used on all skin types?
A: No, it is not suitable for individuals with dark or sunburned skin. Please refer to the color contrast card for guidance on suitable skin tones.

Q: Is it safe to use this product during pregnancy?
A: It is advised to avoid using this product during pregnancy, menstruation, or lactation.

Thank you for choosing our IPL system, for the most effective use of the product, please read the user manual carefully before using.

Safety Tips

Skin Protection Guidelines:

  1. Skin Disorders: Not suitable for individuals with known skin disorders.

  2. Skin Diseases: Avoid use if you have a skin disease like allergic dermatitis or eczema.

  3. Photosensitivity: If you are photosensitive, this product may not be appropriate.

  4. Menstruation, Pregnancy, Lactation: Avoid using this product during menstruation, pregnancy, or lactation.

  5. Sunburn: Do not use if you have sunburn.

  6. Skin Tone: Not suitable for individuals with dark or sunburned skin.
    Please refer to the color contrast card for guidance.

  7. Nevus: Avoid using the product if you have dark or fuscescent nevi (moles).

  8. Wounds and Conditions: Do not apply to broken skin, scabs, healed wounds, cancerous areas, or hemangiomas.

  9. Sensitive Areas: Avoid use on the eyes and any areas with artificial aesthetics, prosthetics, or plastic implants.

Product Introduction

Packing list:
IPL device, Power adapter, User Manual, Wet razor, Safety goggles.

Diagram of controls :

Technical Parameters

Functions Introduction

Skin rejuvenation

  • Hair removal

This product can be used for: excess hair such as lip hair,armpit hair, limb body hair,forehead hair etc.; Painless hair removal is suitable for black hair and dark-hair people, it is not suitable for white, gray or blonde( Refer to the following color contrast card)

Skin and Hair color contrast card

Instructions For Use

Use the razor to shave the hair every time before using the device. If you are sensitive to bright lights, use the safety goggles to protect your eyes when using the device.
Plug in the device using the power adapter. (No battery to charge).

  1. Clean the glass window using a medical alcohol wipe.
  2. Powering On: Press (not hold) the “power button” to turn on the device. The green indicator light will stop flashing, and you will hear the system running.

Note:

  1. Activating the Flash Window: Position the flash window on your skin.
    The red indicator light will start flashing, indicating the presence of a built-in human body induction sensor that detects your skin.

  2. Ensuring Proper Operation: The red indicator light must be flashing for the device to function. If it isn’t flashing, move the flash window closer to your skin.

  3. Selecting Intensity Level: Click the “power button” to choose the desired intensity level. There are five levels, indicated by blue lights. The diagram below shows the levels, ranging from low to high power. Level 1 is the lowest, and level 5 is the highest. You can adjust the intensity level by clicking the power button in sequence.

  4. After setting the intensity level, place the flash window on your skin so it is fully covered. The red indicator light will start flashing. Press the flash button, and the device will emit a single flash. After each flash, the red light will turn off for 1-3 seconds to recharge and will then turn back on, indicating it’s ready for the next use.

Note:

For optimal results, repeat the hair removal process 2-3 times, ensuring that all body parts are treated without omission or repetition.

Troubleshooting Red Indicator Light Issues: If the red indicator light remains steady without flickering, follow these steps:

  1. Ensure the “flash window” is properly positioned and in close contact with your skin.
  2. If the red indicator light still doesn’t flicker, hold the flash window against your skin for 3-5 seconds and check for normal function.
  3. Restart the device if the issue persists.
  4. If these steps don’t resolve the problem, contact our customer service team for further assistance.

Standby Mode: If the device is left unused for 5 minutes, it will enter standby mode. Click the power button to wake it up. Note that upon restarting, the intensity will revert to level 1.

Shutdown: To shut down the device, hold the power button for 3 seconds.

Cleaning: After use, clean the flash window with a recommended medical alcohol wipe.

Note: After frequent usage, a white dew spot may appear inside the lens.This won’t affect normal operation or the device’s lifespan.

Hair Management Process

Skin test before use

Pre-Procedure Skin Test: It’s highly recommended to perform a skin test 2 hours before any hair removal procedure to check for adverse reactions.

Testing Method:

  • Choose a small area of skin on the inside of your upper arm (medial side).
  • Apply 1-2 flashes at the same location, starting from low to high energy levels.
  • After 2 hours, if you notice redness, burns, stabbing pain, or other symptoms, consult a doctor before using again.

Operating Steps:

  1. Preparation: Clean the flash window, shave body hair, and remove any residue from skin.
  2. Device Setup: Start the device and select the appropriate intensity level.
  3. After Care: After hair removal, cool your skin using ice water or a cold, damp towel.
  4. Moisturizing: Apply toner to retain moisture after the procedure. 6.2.5 Intensity Guidance: For recommendations on intensity levels suitable for different skin types and body areas, refer to the comparison table below.
  5. Usage Guidelines: Avoid using the device repeatedly on the same area. Flash no more than twice in a row on a single spot. Reduce usage frequency when using high-energy intensity levels.

Note:

  • Hair Removal Cycle: Use the device 6-10 times per cycle.
  • Initial Frequency: Use once every two weeks for up to six treatments. Extended Frequency: After six treatments, use once every four weeks for the remaining 6-10 sessions.
  • Maintenance: If thin hair regrows after the cycle, treat the area every 2-3 months for continued results.
  • Thick Hair: For thick hair, multiple treatments over time are recommended for optimal results.
  • Individual Variation: Frequency may vary depending on individual hair growth. Reduce usage if only about 30% of the area has regrown hair.

Device Operation Notes

  1. Eye Safety: Avoid flashing near or directly at the eyes while using the device.

  2. Post-Procedure Care: Mild skin redness after use is normal. To soothe the area, apply ice water or a cold, damp towel.

  3. Cleaning Instructions: Avoid cleaning the flash window directly with alcohol spray.

  4. Cosmetics: Do not use the device in conjunction with other cosmetic products.

  5. Dietary Recommendations: Avoid consuming photosensitive foods (e.g. citrus fruits, parsnip, fennel, celery,parsley) during treatment.

  6. Energy Settings: For best results, use a higher energy setting.
    Warning: Follow the previous instructions carefully before doing so.

  7. Skin Reactions: Darker skin may not show immediate reactions, which could be delayed. Ensure a 2-hour waiting period before increasing the intensity.

  8. Post-Treatment Care: Continue to moisturize your skin and use sunscreen as usual.

  9. UV Protection: Avoid UV exposure during treatment. Protect your skin with sunscreen and avoid prolonged exposure to computer radiation.

  10. Ventilation: Do not block the air inlet or cooling outlet, as it may affect the device’s cooling function.

  11. Hair Residue: Hair stuck to the device may cause blank spots but won’t affect performance or normal use.

  12. Bulb Aging: The inner wall of the light bulb may darken over time due to normal aging. It is safe to continue using within the specified parameters.

  13. Water Safety: This product is not waterproof, so avoid contact with water.

  14. Malfunction Response: Immediately unplug the device in case of faults.If the cover or flash window glass is damaged, return the device for repair or replacement.

  15. Safe Storage: Do not store the device in areas with strong magnetic fields, high humidity, dust, or high temperatures.

  16. Child Safety: Prevent damage by keeping the device out of reach and sight of children.

  17. Approved Applications: Only use the device for its intended purposes. Do not use it with unapproved applications.

  18. Authorized Maintenance : Only authorized personnel should open this device. Unauthorized tampering may lead to electric shock or other hazards.

Note: This manual is for reference only.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>