HAMPSHIRE GENERATORS EcoFlow PowerStream Micro Inverter Installation Guide

September 9, 2024
HAMPSHIRE GENERATORS

HAMPSHIRE GENERATORS EcoFlow PowerStream Micro Inverter

Product Information

Specifications

  • Product Name: EcoFlow PowerStream
  • Country of Installation: UK
  • Manufacturer: Hampshire Generators
  • Date: 31/07/2024

Product Usage Instructions

Installation Guidelines

When installing the EcoFlow PowerStream in the UK, it is crucial to ensure that the installation is carried out by a qualified electrician.

Follow these steps for a safe installation:

  1. Contact an electrician to handle the installation process.
  2. Ensure the electrician complies with all local requirements and regulations.
  3. Do not attempt the installation yourself if you are not a qualified electrician.

Further Assistance

If you have any questions or need additional support regarding the installation of the EcoFlow PowerStream, please feel free to contact us. Our team is here to assist you.

Frequently Asked Questions

Q: Can I install the EcoFlow PowerStream myself?

A: It is strongly recommended to seek the assistance of a qualified electrician for the installation to ensure safety and compliance with local regulations.

Q: What should I do if I have questions about the installation?

A: If you have any queries or need further assistance, do not hesitate to reach out to us for guidance and support.

Disclaimer

  • Read this user manual carefully before using the product to ensure that you completely understand the product and can correctly use it. After reading this user manual, keep it properly for future reference.
  • Improper use of this product may cause serious injury to yourself or others, or cause product damage and property loss. Once you use this product, it is deemed that you understand, approve and accept all the terms and content in this document.
  • EcoFlow is not liable for any loss caused by the user’s failure to use this product in compliance with this user manual.
  • In compliance with laws and regulations, EcoFlow reserves the right to the final interpretation of this document and all documents related to this product. This document is subject to changes (updates, revisions, or termination) without prior notice.
  • Please visit EcoFlow’s official website to obtain the latest product information.
  • Hereby, EcoFlow Inc. declares that EcoFlow PowerStream Microinverter complies with Directive 2014/53/EU.
  • The full text of the EU Declaration of Conformity is available at the following internet addresses.
  • http://www.ecoflow.com/eu/eu-compliance
  • http://www.ecoflow.com/de/eu-compliance
  • http://www.ecoflow.com/fr/eu-compliance
  • Hereby, EcoFlow Inc. declares that the EcoFlow PowerStream Microinverter complies with Radio Equipment Regulations 2017.
  • The full text of the UKCA declaration of conformity is available at the following internet address: http://www.ecoflow.com/uk/eu-compliance
  • The crossed-out wheeled bin indicates that the electrical and electronic (EE) products should not be discarded as unsorted waste but must be sent to separate collection facilities for recovery and recycling.
  • The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by EcoFlow Inc. is under license. Other trademarks and trade names are those of their respective owners.

Safety Instruction

General safety

  1. Please carefully read the documents before installing, operating, or maintaining the equipment. The documents are subject to change due to product updates or other reasons.
  2. Do not put heavy objects on the equipment.
  3. Ensure that all cables and connectors are intact and dry before connecting to prevent electric shocks.
  4. Use insulation tools or wear personal protective equipment when you install or operate the equipment.
  5. Do not install or operate the equipment in extreme weather events such as lightning, snow, heavy rain, strong wind, and so on.
  6. Do not damage, smear, or rip off any warning labels on the equipment.
  7. Do not hit, pull, drag, squeeze, or step on the equipment, or throw it into the fire, as there is a risk of explosion.
  8. After installing, please clean the remains of the installation, such as boxes, clipped cable ties, ripped insulation materials, etc.
  9. Do not modify or repair the equipment, please contact our customer service or qualified personnel if necessary.
  10. Use tools and equipment correctly to prevent personal injuries and product damage.
  11. Understand the components and function of the grid-tied PV power system. Make sure that all electrical connections, and voltage and frequency at the connection point meet the local microinverter grid-tie requirements.
  12. Make sure the screws are tightened to the specified torque during installation (M512: 30 Kgfcm; ST512: 45 Kgfcm; M620: 90 Kgfcm).
  13. If you only connect solar panels and the battery with the microinverter without plugging into the AC outlet, the microinverter shall be grounded.
  14. It is strongly recommended to install an overcurrent circuit breaker between the equipment and the grid.
  15. The equipment may get more than 70 °C (158 °F) while in use. Do not touch its enclosure before it cools down. Also, always keep the equipment out of reach of children and pets.
  16. The installation location should be convenient for you to pull out the connectors.
  17. Before you pull out the AC (or battery) connector from the microinverter, disconnect the cable from the AC socket (or battery’s) end.
  18. Make sure the portable power station is off during the whole connection process.
  19. You can only connect solar panels to the PV port and only connect an EcoFlow portable power station to the battery port.

Environment requirements

  1. Make sure the equipment is installed, operated, or stored in a well-ventilated place.
  2. Do not install or operate the equipment near flammable, explosive, corrosive, caustic, or moist sources.
  3. Do not expose the equipment to strong electromagnetic fields to avoid radio interference.

Explanation of Symbols

Symbols on the documentation

Symbols on the device

DANGER Do not damage, smear, or cover any warning labels on the device. All labels must be visible after installation.

What’s in the Box

D     E     F     G| Used for mounting the microinverter on the wall. See “Mount on the wall” for details.
---|---
D     F     H     I| Used for mounting the microinverter on the bracket. See “Mount on the bracket” for details.
J| Used for disconnection, located at the bottom of the protective case. See “Unplug the Cables” for details.

  • The images of the product and components may differ from the actual product.
  • If there are missing or defective components, please contact EcoFlow customer service.

Overview

System Overview

You can purchase optional accessories from the official EcoFlow website.

Product Overview

  1. Antenna
    • Works with the EcoFlow app and Smart Plugs
  2. PV port
    • Connects with solar panels
  3. Battery port / DC port
    • Connects with an EcoFlow portable power station
  4. AC output port
    • Connects to the power grid

LED indication

Assembly

Pre-assembly

  • NOTICE This user manual only provides the cable connection method and the mounting method for the microinverter.
  • For installing the solar panel, please refer to the instructions for the solar panel and its accessories.
  • If you wish to verify the solar system, complete the assembly on a sunny day.

Select a location for the PowerStream Microinverter

  • Make sure that the microinverter is within the Wi-Fi coverage.
  • Do not place or install the microinverter in an area where flammable or explosive materials are stored.
  • The IP rating of the microinverter is IP 67, hence, it can be installed. either indoors or outdoors. However, the EcoFlow portable power station is not waterproof. If your system includes a portable power station, keep both of them indoors.

Measure the distance

  • The lengths of cables vary in different countries or regions. Please refer to the actual products.
  • Except for the standard BKW-Solar cable and the BKW-AC cable, other cables need to be purchased from the official website.

Assembly procedure

  1. Place the microinverter on the Ecoflow portable power station
    • If you need to mount the microinverter, please refer to “Mounting the Microinverter”.
  2. Connect with solar panels
    • NOTICE A BKW-Solar cable includes two groups of MC4 connectors, which can connect with two groups of solar panels.
    • After the solar panels capture solar radiation, they provide direct current to the microinverter. At this time, the LED indicator will light up white.
    • If you connect several solar panels in series or parallel as a group, refer to “Connecting several solar panels in series or parallel”.
    • If you connect the EcoFlow River-series portable power station to the DC port of the microinverter, it is recommended to connect solar panels to the power station, otherwise, the energy will not be stored.
    • For the connection, refer to the user manual of the power station. Download user manuals here.
  3. Connect with the EcoFlow portable power station
    • There are three types of battery connection cables for different EcoFlow portable power stations, as shown in the figures below.
    • NOTICE Make sure the portable power station is off during the whole connection process.
    • If you use the EcoFlow BKW-RIVER cable for the EcoFlow River-series portable power station, the power station only discharges power but does not receive a charge.
  4. Connect to the power grid
    • NOTICE Please confirm that the AC socket is switched on, and the power grid is being powered.
  5. Turn on the EcoFlow portable power station
    • NOTICE If your PowerStream balcony solar system does not include a portable power station, skip this step.
    • After completing the connection, the LED indicator will light up green when the solar panel captures solar radiation and the microinverter outputs AC.
    • It is highly recommended to install the protective case on the top of the microinverter to protect you from high-temperature burns. The protective case is in the box.

Connecting several solar panels in series or in parallel

  • NOTICE If you connect several solar panels in series or parallel as a group, make sure that the maximum operating voltage (Vm) and maximum operating current (Im) of each group do not exceed the maximum input voltage (55V) and maximum output current (13A) of the microinverter PV input.
  • The maximum operating voltage (Vm) and maximum operating current (Im) of solar panels must be consistent respectively.

Solar panels in series

Solar panels in both series and parallel

Mounting the microinverter

  • If your balcony solar system does not include a power station, you can mount the microinverter.
  • DANGER Wear protective goggles or gloves when drilling holes.

Mount on the wall

  1. Use the installation board to locate the hole and drill two holes about 41 mm deep in the wall.
    • Then, insert M5*40 into the holes.
    • Install M5*12 in the corresponding positions on the back of the microinverter.
  2. Insert ST5.525 into M540 through holes in the board.

Mount on the bracket

  1. Install M3*6 in the corresponding positions on the back of the microinverter.
  2. Install two M6*20 in two holes of the installation board, and tighten the M6 nuts on them.
    • CAUTION Please install vertically ≤ 15° for stability and safety.

Grounding considerations

There is an earth wire inside the supplied BKW-AC cable, so grounding can be done directly by using this BKW-AC cable.

If you need to add an additional grounding conductor:

Tools and components (not provided): an M4*6 screw, a grounding wire (cross- section ≥ 4 mm²) with a connection tool, safety gloves, and a driller.

  1. Find the grounding terminal on the bottom of the microinverter.
  2. Insert M4*6 into the grounding terminal through the connection tool of the grounding cable.

EcoFlow App

  • NOTICE The figures are for reference only, please refer to the actual app interface.
  • Control, monitor, and customize your EcoFLow PowerStream microinverter from afar with the EcoFlow app.
  • Download at: https://download.ecoflow.com/app

Privacy policy

Page of your PowerStream balcony solar system

Setting the power supply mode

  • NOTICE This feature can be enabled when the portable power station is connected.
  • On the page of your PowerStream system, tap > “Power supply mode”. Then, select the mode you need.
  • Prioritize power supply: Select this option if you want to prioritize meeting the power consumption of electrical appliances. In this mode, when the power supply exceeds the demand for electrical appliances, the portable power station will be charged.
  • When the demand for electrical appliances is less than the power supply, the portable power station will discharge.
  • Prioritize power storage: Select this option if you want to prioritize charging the portable power station until it reaches its charging limit. In this mode, the portable power station will not discharge to the microinverter.

Setting the AC output power demand

  • On the page of your PowerStream system, tap > “AC output power demand”.
  • The AC output power demand = Power demand from other loads + Load power of smart plugs

Firmware update

  • On the page of your PowerStream system, tap > “Firmware” to check the firmware version of the microinverter and the smart plug to update the firmware.
  • To update the microinverter separately, you can also update the firmware on the “Setting” page of your microinverter.

Page of your microinverter

  • In the list of your devices, tap the microinverter to go to the page of your microinverter.

Unplug the Cables

  • DANGER Do not remove the connector with your hand only. Please use the cable puller supplied with the product to assist in pulling out the connector.
  • If you have installed the protective case, please remove the protective case from the microinverter before you pull out the connector.

Where is the cable puller?

How to use the cable puller?

  • CAUTION Before you remove the battery connection cable, turn off the power station.

Remove connectors in the following order:

NOTICE Before you pull out the AC (or battery) connector from the microinverter, disconnect the cable from the AC socket (or battery’s) end.

Troubleshooting

If the LED indicator turns yellow or red, warning or errors occur. Please follow the instructions in the app or the table below to deal with the problem. If it is not eliminated, please contact the customer service.

DANGER Do not attempt to repair the microinverter.

Error code| LED

indicator

| Name| Suggestion
---|---|---|---
1| Red| Device error| 1. Unplug all cables connected to the PowerStream.

2. Wait for 30 seconds, and then plug in all the cables.

3. If the issue persists, contact customer service.

2| Red| Device error| 1. Unplug all cables connected to the PowerStream.

2. Wait for 30 seconds, and then plug in all the cables.

3. If the issue persists, contact customer service.

4| Red| Device error| 1. Unplug all cables connected to the PowerStream.

2. Wait for 30 seconds, and then plug in all the cables.

3. If the issue persists, contact customer service.

8| (Displayed in-app)| Grid error| 1. Try pulling out the AC cable and inserting it back again. Make sure that the plug is securely inserted.

2. If the issue persists, the power grid is probably faulty. Wait for the power grid to recover.

3. If the issue persists for more than 1 hour, contact customer service.

16| (Displayed in-app)| Grid error| 1. Try pulling out the AC cable and inserting it back again. Make sure that the plug is securely inserted.

2. If the issue persists, the power grid is probably faulty. Wait for the power grid to recover.

3. If the issue persists for more than 1 hour, contact customer service.

32| (Displayed in-app)| Grid error| 1. Try pulling out the AC cable and inserting it back again. Make sure that the plug is securely inserted.

2. If the issue persists, the power grid is probably faulty. Wait for the power grid to recover.

3. If the issue persists for more than 1 hour, contact customer service.

64| (Displayed in the app)| Grid error| 1. Try pulling out the AC cable and inserting it back again. Make sure that the plug is securely inserted.

2. If the issue persists, the power grid is probably faulty. Wait for the power grid to recover.

3. If the issue persists for more than 1 hour, contact customer service.

---|---|---|---
128| (Displayed in the app)| Grid error| 1. Try pulling out the AC cable and inserting it back again. Make sure that the plug is securely inserted.

2. If the issue persists, the power grid is probably faulty. Wait for the power grid to recover.

3. If the issue persists for more than 1 hour, contact customer service.

256| Red| Device error| 1. Unplug all cables connected to the PowerStream.

2. Wait for 30 seconds, and then plug in all the cables.

3. If the issue persists, contact customer service.

512| Red| Device error| 1. Unplug all cables connected to the PowerStream.

2. Wait for 30 seconds, and then plug in all the cables.

3. If the issue persists, contact customer service.

1024| Red| Device error| 1. Unplug all cables connected to the PowerStream.

2. Wait for 30 seconds, and then plug in all the cables.

3. If the issue persists, contact customer service.

4096| (Displayed in the app)| Disconnected from grid| 1. Try pulling out the AC cable and inserting it back again. Make sure that the plug is securely inserted.

2. If the issue persists, the power grid is probably faulty. Wait for the power grid to recover.

3. If the issue persists for more than 1 hour, contact customer service.

16384| Red| Device error| 1. Unplug all cables connected to the PowerStream.

2. Wait for 30 seconds, and then plug in all the cables.

3. If the issue persists, contact customer service.

4| Yellow| Incorrect wiring of the solar panel| Make sure the solar panel is correctly wired. If the issue persists, contact customer service.
8| Yellow| Incorrect wiring of the solar panel| Make sure the solar panel is correctly wired. If the issue persists, contact customer service.

16

|

Yellow

| The device temperature is too high| Keep the ambient temperature within the range of -40 °C to 50 °C. If the issue persists, contact the customer service.
32| Yellow| Temperature too low| Keep the ambient temperature within the range of -40 °C to 50 °C. If the issue persists, contact customer service.
---|---|---|---
64| Red| Overvoltage at the solar panel| Check if the open-circuit voltage of the solar panel is between 11V and 55V.
16| Yellow| Temperature too high| Keep the ambient temperature within the range of -40 °C to 50 °C. If the issue persists, contact customer service.
4| Yellow| The battery level of the power station is too high| Discharge electricity from the power station until the battery level drops to 90%.
16| Yellow| Abnormal voltage at the DC port| Make sure the voltage at the DC port falls within the range of 11V to 15V or 40V to 59V.
32| Yellow| Abnormal voltage at the DC port| Make sure the voltage at the DC port falls within the range of 11V to 15V or 40V to 59V.
8| Yellow| Temperature too high| Keep the ambient temperature within the range of -40 °C to 50 °C. If the issue persists, contact customer service.
16| Yellow| Temperature too low| Keep the ambient temperature within the range of -40 °C to 50 °C. If the issue persists, contact customer service.

Specifications

General info

Model| EFWN511/EFWN511B
Dimension| 242×169×33 (mm)
Weight| Approximately 3 kg
PV port
Operating voltage| 11 – 55 Vd.c.
Maximum input voltage| 55 Vd.c.
Maximum input current| 13 A
Initial input voltage| 15 Vd.c.
Anti-reverse connection protection| Supported
Overvoltage| Ⅱ
Max. PV short circuit current (Isc PV)| 14 A
Max. inverter back feed current to the array| 0 A
BAT / DC port
Discharging mode
Maximum input current| 13 A
Input voltage| 11 -15 Vd.c. , 40 – 59 Vd.c.
Maximum input voltage| 59 Vd.c.
Charging mode
Charging voltage| 30 – 58 Vd.c.
Maximum charging current| 13 A
Rated charging voltage| 48 Vd.c.
Overvoltage| Ⅱ
Battery input short circuit current rating| 20 A
AC port
Output voltage| 220/230/240 Va.c.
---|---
Output frequency| 50 Hz
Output power factor| ±0.8 ~ 1
Maximum output current| EFWN511: 3.7 A

EFWN511B: 2.8 A

Maximum output fault current| 18.4 A
Maximum output overcurrent protection| 4 A
THDI| <=3%@100% load
Overvoltage| Ⅲ
Others
Placed| Indoors or outdoors
Pollution degree| PD3

Ingress Protection rating

|

IP67

Operating temperature| -40 °C to 50 °C (-40 °F to 122 °F)
Humidity| 0 % to 100 %
Altitude| ≤2000 m
Wet location| Yes
Type of inverter| Isolated
Protective class| 1
Wi-Fi (2.4G)| Frequency range:

20M: 2412 – 2472 MHz / 40M: 2422- 2462 MHz

Maximum output power: ≤ 20 dBm

Bluetooth®| Frequency range: 2402-2480MHz Maximum output power: ≤ 20 dBm

For updated parameters, please go to our website to download the latest user manual.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)