Product Information
Specifications
- Out shell material: ABS
- Liquid crystal transparent window material: High hardness acrylic
- Work voltage: DC24V, 36V, 48V, 60V (customizable)
- Communication protocol: UART
Product Usage Instructions
Front and Side View
Ensure that the LCD-M5 Hand Control Panel is mounted with the front view
facing you and the side view accessible for easy operation.
Voltage and Connection Mode
The control panel supports various work voltages including DC24V, 36V, 48V,
and 60V. You can choose the voltage on the meter. The connection mode involves
line sequences for the label connector which includes functions like
instrument power cord, meter data receiving line, and meter earth wire.
Function Description
The LCD-M5 Hand Control Panel offers various display functions such as speed
display, power level display, power indicator, failure warning, total mileage,
single mileage, headlight display, and single driving time display. It also
provides control and setting functions like power switch control, headlight
switch control, wheel diameter setting, maximum speed setting, and more.
Communication Protocol
The control panel uses UART communication protocol for data transmission and
reception.
FAQ
-
Q: What is the material of the outer shell?
A: The outer shell material is ABS while the liquid crystal transparent window material is high hardness acrylic. -
Q: What are the available voltage options for the control panel?
A: The available work voltages are DC24V, 36V, 48V, and 60V. You can select the desired voltage on the meter. -
Q: What functions are displayed on the LCD screen?
A: The LCD screen displays speed, power level, power indicator, failure warnings, total mileage, single mileage, headlight status, and more.
OVERVIEW
Work Voltage and connection mode
- Work voltage: DC24V, 36V, 48V, 60V (which you can choose on the meter), the others you can customized.
- Connection mode:
Table: Line sequence of the label connector table
Order of line | Color of line | Function |
---|---|---|
1 | Brown(VCC) | Instrument power cord |
2 | Green(RX) | Meter data receiving line |
3 | Black(GND) | Meter earth wire |
4 | Orange(K) | Controller power line |
--- | --- | --- |
5 | White(TX) | Data transmission line of instrument |
Notes: Part of the products lead wire use waterproof connection. User cannot see the color of lead line.
Function description
-
Display function
Speed display, power level display, power indicator, failure warning, total mileage, single mileage, headlight display, single driving time display -
Control, setting up functions
Power switch control, headlight switch control, 6Km/h point control, wheel diameter setting, maximum speed setting, idle automatic hibernation time setting, backlight brightness setting, voltage level setting -
Communication protocol: UART
All the contents of the display screen(full display in boot 1S)
Show content introduction
-
Headlight The instrument can be manually turned on and the brightness of the sensing environment is automatically turned on(light sensitivity support is required).
-
Battery power display BATTERY
-
Multifunctional display area
Total mileage ODO, single mileage TRIP A, single mileage TRIP B, battery current voltage VOL, current operating current CUR, remaining mileage RM; Instrument boot time TM -
Vehicle mode
Walk boost mode; Cruise: constant speed cruise mode; PAS: Power file position: 0 ~ 9 adjustable; -
Speed display area
- Maximum speed MAX, average speed AVG
- Unit MPH, KM/H
- The meter will calculate the true speed based on the wheel diameter and signal data
-
Vehicle Status Display Area
**** Vehicle Status Code Meaning:
Status Code | State Meaning | Remarks |
---|---|---|
E06 | Battery under voltage | |
E07 | Motor failure | |
E08 | turn malfunctioning | |
E09 | Controller failure | |
E10 | Communication reception failure | |
E11 | Communication dispatch failure |
-
Setting
-
P01: Backlight brightness, level 1 darkest, level 3 brightest;
-
P02: mileage unit, 0: KM; 1: MILE;
-
P03: Voltage level: 24V, 36V, 48V, 60V, 64V default 36V;
-
P04: Dormancy time: 0, not dormancy; range: 1-60; Unit minutes; default 10 minutes
-
P05: Help file bit: 0, 3 file mode: 1,5 gear mode:
-
P06: Wheel diameter: unit, inch; Precision: 0.1; This parameter is related to the meter display speed and needs to be entered correctly;
-
P07: Speed gauge magnetic steel number: range: 1-100;
This parameter is related to the meter display speed and needs to be entered correctly;
If it is an ordinary hub motor, direct input of magnetic steel;
If it is a high-speed motor, it is also necessary to calculate the deceleration ratio, and
the input data = the number of magnetic steel × deceleration ratio;
For example: number of motor magnets 20, deceleration ratio 4.3: input data is: 86 = 20 × 4.3 -
P08: Speed limit: range 0-100km / H, 100 means no speed limit, The input data here represents the maximum operating speed of the vehicle: for example, input 25, indicating that the maximum operating speed of the vehicle will not exceed 25km/h; Drive speed maintained at set value, Error: ± 1km/h; (Speed limit for power and steering)
Note: The value here is based on kilometers. When the unit setting is converted from kilometers to miles, the speed value of the display interface automatically converts to the correct mile value, but the speed limit value set at this menu under the mile interface is not converted. Is inconsistent with the actual speed limit of the mile speed;
Note: P09-P15 menu is only valid in communication state -
P09: zero start, non-zero start setting, 0: zero start; 1: Non-zero start;
-
P10: The drive mode is set to 0: Power Drive(how much power is output is determined by the power file bit, and the switch is invalid).
- Electric drive(by turning the handle drive, when the power file bit is invalid).
- Power Drive and Electric Drive Coexistence
- P11: Help sensitivity setting range: 1-24;
- P12: Help start intensity setting range: 0-5;
- P13: Power Magnetic Steel Disk Type Setting 5, 8, 12 Magnetic Steel Types
- P14: Controller limit value set default 12A range: 1-20A
- P15: Controller undervoltage
- P16: ODO zero setting length press key 5 seconds ODO zero
- P17 :0: No enabling cruising, 1: enabling cruising; Automatic cruise optional(valid for protocol 2 only)
- P18: Display speed ratio adjustment range: 50 % ~ 150 %,
- P19: 0 power bit, 0: 0, 1: does not include 0
- P20:0:2 Protocol 1:5 S Protocol 2: Standby 3: Standby
-
Key Introduction
- Power on/off: Press and hold the button to power on/off.
- Multi-function display: Turned on display. Click button to switch the multi-functional to display interface at the bottom of the screen will switch between ODO、TRIP、VOL、CUR、TM and ODO are displayed by default after each turn on display. (” TIME “is a single running TIME)
- PAS Set up: Turned on display. Click button to PAS+1. Click button to PAS-1. (The default is PAS1)
- Front light: Turned on display. Press and hold button to turn on/off the front light under the normal display speed interface.
- Walk mode function: Under the interface of normal speed display. When the Ebike is stationary, press and hold button will enter 6KM/h in walk mode. (The walk mode is divided into locked mode and non-locked mode. Locked mode: After press and hold button enters the walking mode, the Ebike still maintains the walk mode after releasing the button. It needs to press and hold button again or brake to exit the walking mode. Non-lock mode: Press and hold button and the walk mode will take effect. Release the button to exit the walk mode.)
- Speed mode display: On the normal display speed interface, press and hold button and button switches the average speed, maximum speed and real-time speed successively. (Default display the real-time SPEED )
- Press and hold button and button enter Settings Parameter value modification: under a parameter state, press button switch Parameters, press button value plus one, press button value minus one. And when it’s modified, press button switch to the next parameter and save the previous parameter value; Press and hold button and button again to save and exit the settings. If not, wait 8 seconds to automatically exit and save the parameters.
- ODO cleared: On the P16 menu interface. Press and hold button for 5 seconds to cleared ODO.
- Reset defaults: On the P16 menu interface. Press and hold button for 2 seconds to reset all defaults. (This operation can not cleared ODO)
Note: due to the upgrade of the company’s products, the content of the product will be different from the specifications, but it will not affect your normal use.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>