neo pure SS-10 Anti Scale System with Hydroblend Stick Installation Guide
- September 3, 2024
- neo PURe
Table of Contents
SS-10 Anti Scale System with Hydroblend Stick
“`html
Specifications:
-
Product Name: ScaleStick SS-10 with HydroBlend Cartridge
-
Application: Prevents limescale build-up and provides corrosion
protection for various water-fed equipment -
Compatibility: Coffee and espresso machines, dishwashers,
tankless water heaters, ice machines, reverse osmosis systems,
distillers, misting systems, instant-hot water dispensers -
Fit: Standard 10 Housings
-
Certification: NSF Certified to meet NSF/ANSI Standard 42 for
material requirements
Product Usage Instructions:
Installation Steps:
-
Locate a suitable spot for the filter housing ensuring easy
access for cartridge replacement. -
Assemble the mounting bracket to the housing cap aligning the
flow direction with your plumbing. -
Mount the bracket on a flat wall surface for vertical housing
screw-on from below. -
Install male adapters into the inlet and outlet ports of the
cap using Teflon tape to prevent leaks. -
Turn off water supply and make plumbing connections using
provided adapters for Pex, CPVC, or Copper. -
Insert the ScaleStick into the cap and secure the housing sump
by hand tightening. -
Turn water back on slowly and check for leaks.
Replacement Cycle:
The media in the ScaleStick will dissolve over time with water
flow. Replace the cartridge when the media is almost depleted.
Media Replacement:
Push the ScaleStick’s o-ring end onto the center port in the cap
for replacement.
FAQ:
How often should I replace the ScaleStick SS-10 cartridge?
The replacement frequency depends on water usage. Monitor the
media level and replace when it is nearly depleted.
Is deliming equipment necessary before installing the
ScaleStick SS-10?
Deliming equipment is recommended but not required. It is
advised to remove any loose scale before installation.
“`
Anti-Scale System with Hydroblend Scale Stick Installation and User Guide
The ScaleStick SS-10 w/ HydroBlend Cartridge prevents limescale build-up while providing corrosion protection for water fed equipment including coffee and espresso machines, dishwashers, tankless water heaters, ice machines, reverse osmosis systems, distillers, misting systems, instant-hot water dispensers. Fits in a Standard 10″ Housings.
4
2
5
Features
HydroBlend The SS-10 features the Hydroblend
compound, which is a unique blend that inhibits mineral scale deposits and provides corrosion
7
6
protection in water-fed equipment. HydroBlend is
unaffected by high temperatures unlike standard scale
control additives like polyphosphates. The SS-10’s
patented design dispenses a controlled amount of
HydroBlend for long-term protection and greater
effectiveness of other standard treatments.
3 1
Operation Recommendations. It is possible for pre- existing scale in your
equipment to come loose and clog downstream equipment. Please remove any loose
scale before installing the ScaleStick SS-10. Deliming your equipment prior to
use is recommended, but it is not required. It is best practice to inspect the
ScaleStick cartridge every 6 months. The SS-10 should be replaced before the
HydroBlend is completely dissolved.
NSF Certified. This filter has been certified by NSF International to meet
NSF/ANSI Standard 42 for material requirements only.
Kit Includes:
Number Description
1
Scale Stick 10
2
NP 10″ Standard Housing w/PR 3/4 FPT Blk / Clear
3
Mounting Bracket for STD housings
4
Male adapters 3/4 CTS x 3/4 NPT
5
Housing Wrench
6
Screws to mount cap on the bracket
7
Teflon Tape
Qty 1 1 1 2 1 4 1
REV 2/24
Anti-Scale System with Hydroblend Scale Stick Installation and User Guides
Installation Precautions: · Install on cold water line only. Maximum
temperature for
the housing and ScaleStick is 100F · Do not install where the unit could
freeze · Maximum pressure is 90 psi · Scale Stick is good for flow rates up to
6 gpm
Installation Steps
1. Locate a spot where the filter housing will be accessible and replacing the cartridge will be easily accomplished. Make sure you will have 6-10″ of vertical clearance below the housing cap.
2. Assemble the mounting bracket to the housing cap so the flow direction of the cap matches how your plumbing flows.
3. Mount the bracket with the cap now attached to a flat wall surface so that the housing will screw onto the cap vertically from below.
4. Install the male adapters into the inlet and outlet ports of the cap using a few wraps of Teflon tape on the threads. Be careful to not over tighten.
5. Turn the water off and make plumbing connections. Included adapters will work with Pex, CPVC or Copper. If threading copper directly to cap, be sure and solder parts before threading into the plastic cap.
6. Install the ScaleStick by inserting the top of the stick in the cap
7. Screw housing sump up on the cap. The housing sump only needs to be hand tight, do not use the wrench to tighten.
8. Slowly turn water back on and check for leaks.
9. The ScaleStick does not need to be flushed
Replacement Cycle:
Frequency of replacement will vary based on
water usage. The media in the ScaleStick will
slowly dissolve as water flow through the housing.
Watch the level of media and replace when it is
almost depleted.
Media
Push the ScaleStick’s o-ring end onto the center port in the cap
Push it on until it contacts the cap
REV 2/24
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>