HDWR Global H1000P Hook scale
Product Information
- Model: wagPRO-H1000P
- Capacity: 1 ton
- Features: Remote control operation, stable weight indicator, tare function
Product Usage Instructions
Safety Instructions:
- Do not overload the scale.
- Avoid leaving the load hanging on the scale hook for extended periods.
- Regularly inspect the hook and screws for any damage.
- Avoid using the scale during thunderstorms or in rainy conditions.
- Hang the scale in a dry and well-ventilated area, not directly on the ground.
- Do not attempt to repair the scale yourself; contact the supplier for assistance.
Operating Instructions:
- To turn on the scale, press and hold the power button for 3 seconds.
- If a non-zero value appears on the display, press the tare button to reset to zero.
- To pause the screen with the displayed weight, use the HOLD UNIT button. Pressing again will unlock the screen.
- Press and hold the unit button for 1 second to change between kilograms and pounds units.
- Indicators: S – stable weight, Z – weight at 0, T – tare, H – locked screen, LB – pounds unit, KG – kilograms unit.
Operation via Remote Control:
Further details on operating the scale via remote control can be found in the
specific remote control operation section of the manual.
FAQ:
Common Problems and Solutions:
- Problem: The scale does not start when the power button is turned on.
- Possible Causes:
- Dead battery
- Broken power button
- Broken power cord
- Solution:
- Check and charge the battery if discharged.
- Press the power button harder for 2 seconds.
- Inspect and check the power cord.
Specification
- Material: steel
- Maximum nominal load: 1000 kg
- Maximum permissible load: 100% of nominal load
- Maximum Safety Load: 120% of Nominal Load
- Display: Digital LCD
- Display Backlight: Blue
- Additional Functions: Pause Screen, Tare Scale, Swap Units
- Available weight units: kg, lb
- Battery type: Lithium-ion
- Power supply: mains, battery
- Battery capacity: 2400mAh
- Battery life: up to 4 days
- Standby time: up to 2 weeks
- Operating temperature: -10 – 40°C
- Operating humidity: up to 90% at 20°C
- Device dimensions: 26 x 14 x 5 cm
- Package dimensions: 27.5 x 18 x 10 cm
- Package weight: 1.3 kg
The set contains
- Hook scale PRO-H1000P
- Hook holder with robust safety latch and clamping pin
- AC adapter
- Remote control for scale control
- Manual
Features
- Solid steel construction for safety
- Can weigh products up to 1 tonne
- Remote control for convenience
- Ability to change units and measure in kilograms and pounds
- Clear LCD display with blue backlight
- 2400 mAh battery for up to 4 days of battery life
Taking care of the battery
To maximize battery life, follow these battery care rules.
- The battery compartment can be opened by removing 2 screws.
- Depending on the brightness of the backlight and the idle mode setting, the battery lasts more than 65 hours.
- To save battery life, turn on auto power off and dim the backlight brightness when idle.
- For maximum life, the battery should be stored between -20°C and +50°C.
Troubleshooting
Below are the most common problems and their solutions. If you don’t find a solution, contact your supplier.
Problem:
The scale does not start when the power button is turned on.
Possible causes:
- Dead battery
- Broken power button
- Damaged power cord
Solution:
- Check the battery and if it is discharged, charge it.
- Press the power button harder and press for 2 seconds
- Check the power cord
Safety Instructions
To ensure good performance and precise measurements, please follow the following safety rules during daily operation and maintenance.
- Do not overload the scale. Doing so may damage the load cell and void the warranty.
- Do not leave the load hanging on the scale hook for a long time. This can affect the accuracy of the balance and shorten the lifespan of the load cells.
- Inspect the hook and the ratchet on it before use. Check the condition of the hook and screws regularly.
- Do not use the scale during a thunderstorm, do not expose it to rain.
- The scale should be hung in a dry and well-ventilated area. Do not place the scale directly on the ground.
- Do not attempt to repair the scale yourself. If you have any problems, please contact your supplier.
Operating Instructions
- To turn on the scale, hold the button for 3 seconds.
- If a value other than 0.0 appears on the display, press the button to tap the device.
- The device gives you the option to pause the screen with the currently displayed weight. To do this, use the button, and the letter H will appear at the bottom of the screen.
- Pressing the HOLD UNIT key again will unlock the screen.
- Holding down the key for 1 second allows you to change the current unit.
- When the KG mark is visible on the screen, the kilograms are set. When the LB designation appears on the screen, the unit set is pounds.
Indicators
- S – informs about the stable weight of the product
- Z – informs about the weight with a value of 0
- T – informs about the taring of the device
- H – informs about the locked screen with the current value
- LB – indicates the unit set to pounds
- KG – informs about the unit set to kilograms
Operation via remote control
With the remote control included in the set, you can conveniently operate the scale from a distance.
- Key A – used to turn off the device
- B key – short press to stop the screen with the current value of the weighed product. Press for 3 seconds to change the unit.
- C key – tare the scale
- D key – change the backlight mode. It is possible to set the backlight to turn off automatically after a few seconds (d — AUT), turn off the backlight completely (d — OFF), and turn the backlight on all the time (d — ON).