DMX king eDMX1 MAX DIN sACN to DMX Controller User Manual
- August 30, 2024
- DMX king
Table of Contents
eDMX1 MAX DIN
USER MANUAL
INTRODUCTION
Thanks for purchasing a DMXking product. Our aim is to bring you high quality products with great features we know you’ll appreciate. DMXking MAX series devices are Art-Net and sACN/E1.31 protocol compatible designed for use with computer based show control software or expansion of lighting console outputs. There are many free and commercial software packages available. http://dmxking.com/control-software
HARDWARE AND FIRMWARE VERSIONS
From time-to-time minor hardware changes occur in our products usually small
feature additions or unseen optimizations. The table below lists eDMX1 MAX DIN
product variants. Check the product label for P/N details.
Part Number | Feature addition |
---|---|
0125-1.0-3 | Initial product release. 3pin screw terminal. |
0125-1.0-8 | Initial product release. 8pin RJ45 socket. |
Firmware updates are released on a semi-regular basis. We recommend updating to the latest available firmware version so all product features are available. Please take note the user manual reflects latest firmware version features unless otherwise noted.
Firmware Version | Comments |
---|---|
V4.6 | Initial release. RDM support. |
V4.7 | SD card detection improvements. |
MAIN FEATURES
- Wide input power range 7-28Vdc
- Optional power from USB-C
- OEM board available for integration into your designs
- DIN rail and wall mount using built in clips
- Static or DHCP IPv4 network addressing
- USB DMX functionality in addition to Network Art-Net/sACN
- Supported operating systems: Windows, MacOS, Linux, iOS, Android
- eDMX1 MAX DIN – 1x DMX512 OUT or DMX512 IN with Art-Net, sACN E1.31 and E1.20 RDM support
- Art-Net broadcast, Art-Net II,3 & 4 unicast, sACN/E1.31 Multicast and sACN Unicast support
- Merge 2 incoming Art-Net/sACN streams per output channel with both HTP and LTP options
- sACN Priority takeover for multi-tier controller arrangements
- Mix and match Art-Net with sACN merge/priority sources
- DMX-IN and DMX-OUT channel offset re-mapping
- User configuration of Art-Net Node short and long names
- Fully compatible with all software and hardware that supports Art-Net I, II, 3 & 4 and sACN protocols
- Works with your existing console if Art-Net or sACN external nodes are supported
- Universe Sync Art-Net, sACN and Madrix Post Sync
- Recording and playback to microSD card (not included). See eDMX MAX Record / Playback manual
- Standalone show playback without computer or network connection
- Show triggering via I/O Port
- Internal clock with optional battery backup for timed playback. NTP time sync
- Configuration utility with basic Art-Net output/input test functionality
- USB and Network configuration supported
eDMX MAX translates Art-Net 00:0:0 to Universe 1 (i.e. offset by 1) so there is an easy mapping between sACN/E1.31 and Art-Net.
EXTERIOR VIEW
FRONT VIEW
I/O VIEW Network 10/100Mbps RJ45 socket. Pluggable 2way 5mm pitch
terminal block for 7-28Vdc power input. One 3way 5.0mm pitch pluggable
terminal block connector or 1x RJ45 socket for DMX512.
STATUS LED TABLE
LED | Indication |
---|---|
Protocol | Protocol activity. Flash Red = Art-Net/sACN. Solid Red = Bootloader |
mode
Link/Act| Network activity. Green = Link, Flash = Trafficxc
Port A| DMX512 Port A TX/RX activity
USB DMX OPERATION
DMXking MAX series devices include USB DMX functionality alongside Ethernet
lighting protocols Art-Net/sACN.
SOFTWARE COMPATIBILITY
Software packages for USB DMX use either a Virtual COM Port (VCP) driver or
FTDI specific D2XX driver. DMXking MAX series uses VCP which is more universal
than FTDI D2XX, especially across different operating systems, however this
has created some compatibility issues with existing software packages using
the later. We are working with software developers still using D2XX to
encourage updating their code to utilize VCP instead and also leverage DMXking
USB DMX protocol extensions that allow multiple universe operation.
Check https://dmxking.com/ for DMXking MAX series USB
DMX compatible software list.
DEVICE CONFIGURATION
Previously DMXking USB DMX capable devices did not require DMX port
configuration for DMX-IN mode as this was automatically selected by certain
USB DMX messages. This has changed in DMXking MAX series devices which now
require explicit DMX-OUT or DMX-IN port configuration along with selecting
which port to forward over USB DMX to allow multi-port devices to function
with complete flexibility.
DMX PORT MAPPING
Simple USB DMX protocol output messages are automatically mapped to the
physical DMX512 ports regardless of configured universe.
USB DMX SERIAL NUMBER
For software compatibility reasons a BCD serial number is calculated from the
MAX device hardware MAC address using the lower 3 hexadecimal bytes converted
to a decimal number. Software that has been updated for MAX series devices
will display the hardware MAC address.
DEFAULT CONFIGURATION
All eDMX1 MAX DIN units ship with default IP address settings. Please reconfigure network settings as required before use.
Parameter | Default Setting |
---|---|
IP Address | 192.168.0.112 |
Subnet Mask | 255.255.255.0 |
Default Gateway | 192.168.0.254 |
IGMPv2 Unsolicited Report | Unchecked |
Network Mode | Static IP address |
DMX512 Port configuration parameter defaults.
Parameter | Default Setting |
---|---|
Async Update Rate | 40 [DMX512 frames per second]. Universe Sync will override. |
Port Operation Mode | DMX-OUT |
Timeout all sources | Unchecked |
USB Forwarding [DMX-IN] | Unchecked |
Channel Offset | 0 |
Fixed IP | 0.0.0.0 [Only for DMX IN – Unicast to 1 IP address only] |
Merge Mode | HTP |
Full DMX Frame | Unchecked |
*Broadcast Threshold | 0 [Art-Net broadcast] |
Unicast IP [DMX-IN] | 0.0.0.0 |
sACN Priority [DMX-IN] | 100 |
RDM Enable | Unchecked |
RDM Discovery Period [DMX-OUT] | 0s / RDM Disabled |
RDM Packet Spacing [DMX-OUT] | 1/20s |
DMX-OUT Failsafe Mode | Hold Last |
Recall DMX Snapshot at startup | Unchecked |
DMX512 Universe | 1-8 [Art-Net Net 00, Subnet 0, Universe 0-7] Note: sACN |
Universe 1 = Art-Net 00:0:0
*Global threshold for all DMX-IN ports, configured only in Port A settings tab.
CONFIGURATION UTILITY
Download latest eDMX MAX Configuration Utility from https://dmxking.com
/downloads-list
*eDMX1 MAX DIN requires eDMX MAX Configuration Utility v2.2+
User manual for the utility
https://dmxking.com/downloads/eDMXMAXConfigurationUtilityUserManual(EN).pdf
TECHNICAL SPECIFICATIONS
- Dimensions: 53mm x 90mm x 32mm (WxDxH)
- Weight: 70 grams
- DC Power input 7-28Vdc, 2.5W max. Typical current consumption @ 12Vdc 200mA
- USB-C power input. Any USB power source, only 5V supply is negotiated @ 300mA maximum current.
- DMX512 connector: 3 way 5.0mm pitch terminal block or RJ45 socket
- DMX512 port is NOT isolated
- Ethernet 10/100Mbps Auto MDI-X port.
- Internal DMX512-A line biasing termination as per ANSI E1.20 RDM requirements
- Art-Net, Art-Net II, Art-Net 3, Art-Net 4 and sACN/E1.31 support.
- ANSI E1.20 RDM compliant with RDM over Art-Net.
- Universe Sync Art-Net, sACN and Madrix Post Sync.
- Both HTP and LTP merging of 2 Art-Net streams
- sACN Priority
- IPv4 Addressing
- IGMPv2 for multicast network management
- DMX512 Frame Rate: Adjustable per port
- Operating temperature -10C to 50C non-condensing dry environment
WARRANTY
DMXKING HARDWARE LIMITED WARRANTY
What is covered
This warranty covers any defects in materials or workmanship with the
exceptions stated below.
How long coverage lasts
This warranty runs for two years from the date of shipment from an authorized
DMXking distributor.
What is not covered
Failure due to operator error or incorrect application of product.
What DMXking will do
DMXking will repair or replace, at its sole discretion, the defective
hardware.
H ow to obtain service
Contact your local distributor https://dmxking.com/distributors
ACKNOWLEDGEMENTS
Art-Net™ Designed by and Copyright Artistic Licence
DECLARATIONS
The eDMX1 MAX DIN has been tested against applicable standards and certified
compliant as below.
Standard|
---|---
IEC 62368-1| Audio/Video and ICTE Safety Requirements
IEC 55032| Radiated Emissions
IEC 55035| EMC Immunity Requirements
FCC Part 15| Radiated Emissions
RoHS 3| Restriction or Hazardous Substances
Certification| Country
---|---
CE| Europe
FCC| North America
RCM| New Zealand / Australia
UKCA| United Kingdom
DMXking.com
JPK Systems Limited
New Zealand
0125-700-4.7
References