PLANET ISW-500T, ISW-800T Industrial 5-/8-Port 10/100TX Compact Ethernet Switch User Manual

August 30, 2024
PLANET

ISW-500T, ISW-800T Industrial 5-/8-Port 10/100TX Compact Ethernet Switch

“`html

Product Specifications

  • Product: ISW-500T / ISW-800T

  • Hardware Specifications:

    • Hardware Version: 2

    • Copper Ports: 5 x 10/100BASE-TX RJ45 TP
      auto-MDI/MDI-X (ISW-500T) / 8 x 10/100BASE-TX RJ45 TP
      auto-MDI/MDI-X (ISW-800T)

    • Connector: Removable 6-pin terminal block

    • Alarm LED: Provides one relay output for power
      failure. Alarm relay current carry ability: 1A@DC 24V

    • LEDs:

    • 3 x LED for system and power: Green: DC Power 1, Green: DC
      Power 2, Red: Power Alarm

    • 1 x LED for each copper port: Green: 10/100Mbps LNK/ACT

    • ESD Protection: 6KV

    • EFT Protection: 6KV

    • Power Requirements: 12~48V DC, redundant power
      with reverse polarity protection function, 24V AC power
      support

    • Power Consumption / Dissipation: Max. 1.1
      watts/3.77BTU (Power on without any connection), Max. 2
      watts/6.86BTU (Ethernet full loading)

Product Usage Instructions

1. Installation

1.1 Unpack the Industrial Ethernet Switch and ensure all package
contents are present.

1.2 Choose between DIN-rail or wall-mount installation using the
provided kits.

2. Power Connection

2.1 Connect the power source (12~48V DC or 24V AC) to the
terminal block according to the provided pin configuration.

3. Network Connection

3.1 Connect Ethernet cables to the RJ45 ports of the switch.

3.2 Ensure proper auto-negotiation and MDI/MDI-X settings for
network communication.

4. LED Indicators

4.1 Monitor the LED indicators for system status, power status,
port link/activity, and power alarm.

Frequently Asked Questions (FAQ)

Q: What should I do if any package contents are missing or

damaged?

A: If any items are missing or damaged, please contact your
dealer immediately. Retain the original packing materials for
potential return.

Q: How do I access the online user manual or quick installation

guide?

A: Scan the provided QR code with your device’s camera to access
the online resources in multiple languages.

Q: What power source options are supported by the switch?

A: The switch supports a power input range of 12~48V DC with
redundant power capabilities and reverse polarity protection.

“`

Industrial 5-/8-Port 10/100TX Compact Ethernet Switch
ISW-500T/ISW-800T User’s Manual

Table of Contents
1. Package Contents ……………………………………………………………………………… 3 2. Product Specifications ………………………………………………………………………… 4 3. Hardware Introduction ……………………………………………………………………….. 6
3.1 Three-View Diagram…………………………………………………………………….. 6 3.2 Front View ………………………………………………………………………………… 8 3.3 LED Definition ……………………………………………………………………………. 8 3.4 Top View …………………………………………………………………………………… 9 3.5 Wiring the Power Inputs ……………………………………………………………….. 9 3.6 Wiring the Fault Alarm Contact …………………………………………………….. 12 3.7 Grounding the Device…………………………………………………………………. 12 4. Installation…………………………………………………………………………………….. 13 4.1 DIN-rail Mounting Installation……………………………………………………….. 13 4.2 Wall-mount Plate Mounting ………………………………………………………….. 14 4.3 Side Wall-mount Plate Mounting……………………………………………………. 14 5. Customer Support …………………………………………………………………………… 15

1. Package Contents
Thank you for purchasing PLANET industrial 5-/8-port 10/100TX Compact Ethernet Switch, ISW-500T/800T. In the following section, the term “Industrial Ethernet Switch” means the ISW-500T or ISW-800T.
Open the box of the Industrial Ethernet Switch and carefully unpack it. The box should contain the following items:

Industrial Ethernet Switch x 1

QR Code Sheet x 1

DIN-rail Kit x 1

Wall-mount Kit x 1

Let’s get started with your PLANET product ISW-500T

EN

Please scan the QR code to browse our online User’s Manual or Quick Installation Guide and follow the instructions to complete the setup.

Bitte scannen Sie den QR Code sie werden per Browser zur DE Bedienungsanleitung oder Schnellanleitung weiter geleitet. Folgen Sie den
Anweisungen um die Installation abzuschließen.

Veuillez scanner le code QR pour obtenir notre Notice d’Utilisation en FR ligne ou notre Guide d’Installation Rapide et suivez les instructions pour
compléter la configuration

Escanee el código QR para encontrar el Manual del Usuario en línea o

ES la Guía de Instalación Rápida y siga las instrucciones para completar la

configuración.

User’s Manual

IT

Scansiona il codice QR per consultare online il Manuale utente o la Guida di installazione rapida e segui le istruzioni per completare la configurazione.

PT

Por favor, escaneie o QR code para navegar no Manual do Usuário ou Guia de Instalação Rápida. Siga as instruções para completar a configuração.

Zeskanuj kod QR, aby otworzy nasz internetow instrukcj obslugi PL lub instrukcj szybkiej instalacji. Postpuj zgodnie z instrukcjami, aby
zakoczy poprawn konfiguracj.

One word modify: QR-, RU –
,

RO Te rugam sa scanezi codul QR, pentru a descarca User’s Manual sau Quick Installation Guide si a urmari instructiunile necesare in finalizarea instalarii

AR

Need more help?
PLANET online FAQs: http://www.planet.com.tw/en/support/faq Technical Support: support@planet.com.tw

Copyright © PLANET Technology Corp. 2024. Contents are subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.

Part No. 2360-AH0780-001

RJ45 Dust Cap

ISW-500T x 5 ISW-800T x 8
If any of these are missing or damaged, please contact your dealer immediately; if possible, retain the carton including the original packing material, and use them again to repack the product in case there is a need to return it to us for repair.

3

2. Product Specifications

Product

ISW-500T

ISW-800T

Hardware Specifications Hardware Version Copper Ports Connector Alarm
LED

2

5 x 10/100BASE-TX RJ45 TP auto-MDI/MDI-X, auto negotiation

8 x 10/100BASE-TX RJ45 TP auto-MDI/MDI-X, auto negotiation

Removable 6-pin terminal block Pin 1/2 for Power 1; Pin 3/4 for fault alarm; Pin 5/6 for Power 2

Provides one relay output for power failure. Alarm relay current carry ability: 1A@DC 24V

3 x LED for system and power: Green: DC Power 1 Green: DC Power 2 Red: Power Alarm
1 x LED for each copper port: Green: 10/100Mbps LNK/ACT

ESD Protection

6KV

EFT Protection Power Requirements

6KV
12~48V DC, redundant power with reverse polarity protection function, 24V AC power support

Power Consumption / Dissipation

Max. 1.1 watts/3.77BTU (Power on without any connection) Max. 2 watts/6.86BTU (Ethernet full loading)

Max. 1.1 watts/3.77BTU (Power on without any connection) Max. 2.5 watts/8.57BTU (Ethernet full loading)

Installation Enclosure

DIN-rail kit and wall-mount ear IP30 metal case

Dimensions (W x D x H) Weight

30 x 70 x 104 mm 255g

41 x 70 x 115 mm 300g

4

Standards Conformance

Switch Processing Scheme Store-and-Forward

Address Table

1K entries

Shared Data Buffer Flow Control

448K bits
Back pressure for half duplex IEEE 802.3x pause frame for full duplex

Switch Fabric

1Gbps

1.6Gbps

Throughput (packet per second)

0.74Mpps@64bytes

1.19Mpps@ 64 bytes

Network Cables

10/100BASE-TX Cat. 3, 4, 5, 5e, 6 UTP cable (max. 100 meters) EIA/TIA-568 100-ohm STP (max. 100 meters)

Standards Conformance

Standards Compliance

IEEE 802.3 Ethernet IEEE 802.3u Fast Ethernet IEEE 802.3x Full-Duplex Flow Control
IEEE 802.3az Energy Efficient Ethernet IEEE 802.1p Class of Service
PROFINET Traffic Passthrough with QoS

Regulatory Compliance

FCC Part 15 Class A, CE

Stability Testing

IEC60068-2-32 (free fall) IEC60068-2-27 (shock) IEC60068-2-6 (vibration)

Environment

Temperature

Operating: -40 ~ 75 degrees C Storage: -40 ~ 85 degrees C

Humidity

Operating: 5~95%, Storage: 5~95% (non-condensing)

5

3. Hardware Introduction
3.1 Three-View Diagram
The three-view diagram of the Industrial Ethernet Switch consists of five or eight auto-sensing 10/100BASE-TX RJ45 port and one removable 6-pin terminal block. The LED indicators are also located on the front panel.
Top View

V1+ PWR1

V2+ Alarm PWR2

DC Input: 12-48V , 0.17A max. AC Input: 24V , 0.15A max.

Max. Fault Alarm Loading: 24V, 1A

40.00 18.00

Side View

70.00
104.00 30.00
30.00 50.00

Front View
P1 P2 Fault 10/100
LNK ACT 1 2 3 4 5
ISW-500T

Side View Bottom View

52.00

52.00

Rear View

Mounting Kit

91.00 9.00
18.00

Mounting Kit

18.00

28.00

40.00

147.00 48.80

DIN-Rail Kit

Figure 1: ISW-500T Three-View Diagram

Unit: mm

6

Top View

Max. Fault Alarm Loading: 24V, 1A

V1+ PWR1

V2+ Alarm PWR2

70.00

DC Input: 12-48V , 0.2A max. AC Input: 24V , 0.16A max.

Side View

Front View

P1 P2 Alarm 1 2 3 4 5 6 7 8 10/100 LNK ACT
ISW-800T
Bottom View

115.00 41.00

Side View

18.00
27.19 28.65 70.00

Rear View

Mounting Kit

DIN-Rail Kit

103.00 9.00

Mounting Kit

Figure 2: ISW-800T Three-View Diagram

Unit: mm

7

3.2 Front View

P1 P2 Alarm 10/100
LNK ACT 1 2 3 4 5
ISW-500T
Figure 3: ISW-500T Front View

P1 P2 Alarm
1 2 3 4 5 6 7 8 10/100 LNK ACT
ISW-800T
Figure 4: ISW-800T Front View

3.3 LED Definition System

LED Color

Function

DC1 Green Lights to indicate DC power input 1 has power.

DC2 Green Lights to indicate DC power input 2 has power.

Alarm Red Lights to indicate that AC or DC power has failed.

Per 10/100BASE-TX Port

LED

Color

10/100 LNK/ACT

Green

Lights Blinks

Function
Indicating the port is running at 10/100Mbps and successfully established.
Indicating that the switch is actively sending or receiving data over that port.

8

3.4 Top View

Max. Fault Alarm Loading: 24V, 1A
1 2 3 4 5 6

V1+ PWR1

V2+ Alarm PWR2

DC Input: 12-48V , 0.17A max. AC Input: 24V , 0.15A max.

Figure 5: ISW-500T Top View

Max. Fault Alarm Loading: 24V, 1A
1 2 3 4 5 6

V1+ PWR1

V2+ Alarm PWR2

DC Input: 12-48V , 0.2A max. AC Input: 24V , 0.16A max.

Figure 6: ISW-800T Top View

3.5 Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of Industrial Ethernet Switch is used for two DC redundant power inputs. Please follow the steps below to insert the power wire by professionals.
When performing any of the procedures like inserting the wires or tightening the wire-clamp screws, make sure the power is OFF to prevent from getting an electric shock.

Lorsque vous effectuez l’une des procédures telles que l’insertion des fils ou le serrage des vis de serrage, assurez-vous que l’alimentation est coupée pour éviter tout choc électrique.

9

[ISW-500T] 1. Insert positive and negative DC power wires into contacts 1 and 2 for Power 1,
or 5 and 6 for Power 2.
Max. Fault Alarm Loading: 24V, 1A
1 2 3 4 5 6

V1+ PWR1

V2+ Alarm PWR2

DC Input: 12-48V , 0.17A max. AC Input: 24V , 0.15A max.

Wire Range 12-24 AWG Str/Sol

Wire Type FW

Cu

2

Torque In-lbs (N.m) 5 (0.56)

2. This product is intended to be supplied with a UL-listed power adapter or power source, rated 24V AC 50/60Hz min. 0.15A or 12-48V DC min. 0.17A, and Tma 75°C (max.).
3. Tighten the wire-clamp screws for preventing the wires from loosening.

12 Power 1 +-

34 Alarm

56 Power 2 +-

1. The power input range is 12V ~ 48V DC and supports 24V AC. 2. Use one power input when using 24V AC.

1. La plage d’entrée d’alimentation est de 12V ~ 48V DC et prend en charge 24V AC.
2. Utilisez une entrée d’alimentation lorsque vous utilisez 24V AC.

10

[ISW-800T] 1. Insert positive and negative DC power wires into contacts 1 and 2 for POWER 1, or contacts 5 and 6 for POWER.

Max. Fault Alarm Loading: 24V, 1A
1 2 3 4 5 6

V1+ PWR1

V2+ Alarm PWR2

DC Input: 12-48V , 0.2A max. AC Input: 24V , 0.16A max.

Wire Range 12-24 AWG Str/Sol

Wire Type FW

Cu

2

Torque In-lbs (N.m) 5 (0.56)

2. This product is intended to be supplied with a UL-listed power adapter or power source, rated 24V AC, 50/60Hz min. 0.16A or 12-48V DC, min. 0.2A, and Tma 75°C (max.).
3. Tighten the wire-clamp screws for preventing the wires from loosening.

12 Power 1 +-

34 Alarm

56 Power 2 +-

1. The power input range is 12V ~ 48V DC and supports 24V AC. 2. Use one power input when using 24V AC.

1. La plage d’entrée d’alimentation est de 12V ~ 48V DC et prend en charge 24V AC.
2. Utilisez une entrée d’alimentation lorsque vous utilisez 24V AC.

11

3.6 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block connector as the picture shows below. Inserting the wires, the Industrial Ethernet Switch will detect the fault status of the power failure and then forms an open circuit. The following illustration shows an application example for wiring the fault alarm contacts.
123456

Fault Alarm Contacts

Alarm

The Fault Alarm Contacts are energized (CLOSE) for normal operation and will OPEN when failure occurs

Insert the wires into the fault alarm contacts

Wire Range 12-24 AWG Str/Sol

Wire Type FW

Cu

2

Torque In-lbs (N.m) 5 (0.56)

Alarm relay circuit accepts up to 24V DC, 1A.

3.7 Grounding the Device
Users MUST complete grounding wired with power cord adapter or power supply source should be connected to a socket outlet with an earthing connection; otherwise, a sudden lightning could cause fatal damage to the device

Max. Fault Alarm Loading: 24V, 1A
1 2 3 4 5 6

V1+ PWR1

V2+ Alarm PWR2

DC Input: 12-48V , 0.17A max. AC Input: 24V , 0.15A max.

EMD (Lightning) DAMAGE IS NOT COVERED UNDER WARRANTY.

LES DOMMAGES EMD (éclair) NE SONT PAS PRIS SOUS GARANTIE. 12

4. Installation
This section describes the functionalities of the Industrial Ethernet Switch’s components and guides you to installing it on the DIN rail and wall. Please read this chapter completely before continuing.
This following pictures show the user how to install the device, and the device is not ISW-500T or ISW-800T.
4.1 DIN-rail Mounting Installation
1 2
13

4.2 Wall-mount Plate Mounting
Mount on product or wall (Screw size and quantity: 4mm (L), 3mm (dia.) and 4pcs); DIN-rail mount on product (Screw size and quantity: 4mm (L), 3mm (dia.) and 3pcs)
4.3 Side Wall-mount Plate Mounting
You must use the screws supplied with the wall-mounting brackets. Damage caused to the parts by using incorrect screws would invalidate your warranty. Vous devez utiliser les vis fournies avec les supports muraux. Les dommages causés aux pièces par l’utilisation de vis incorrectes invalideraient votre garantie.
14

5. Customer Support
Thank you for purchasing PLANET products. You can browse our online FAQ resource on PLANET web site first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team. PLANET online FAQs: http://www.planet.com.tw/en/support/faq.php Support team mail address: support @planet.com.tw
Copyright © PLANET Technology Corp. 2024. Contents are subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.
15

FCC Warning This equipment has been tested and found to comply with the regulations for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this user’s guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
Avertissement de la FCC Cet équipement a été testé et jugé conforme à la réglementation pour un appareil numérique de classe A, conformément à la partie 15 des règles de la FCC. Ces limites sont conçues pour fournir une protection raisonnable contre les interférences nuisibles lorsque l’équipement est utilisé dans un environnement commercial. Cet équipement génère, utilise et peut émettre de l’énergie radiofréquence et, s’il n’est pas installé et utilisé conformément au présent guide de l’utilisateur, peut causer des interférences nuisibles aux communications radio. Le fonctionnement de ces équipements dans une zone résidentielle est susceptible de provoquer des interférences préjudiciables, auquel cas l’utilisateur sera tenu de corriger les interférences à ses propres frais.
CE Mark Warning This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference.
Avertissement de marquage CE Il s’agit d’un produit de classe A. Dans un environnement domestique, ce produit peut provoquer des interférences radio, auquel cas l’utilisateur peut être tenu de prendre des mesures adéquates. Cet équipement est conforme à la classe A du CISPR 32. Dans un environnement résidentiel, cet équipement peut causer des interférences radio.
16

WEEE Warning To avoid the potential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment, end users of electrical and electronic equipment should understand the meaning of the crossed-out wheeled bin symbol. Do not
dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately. Avertissement WEEE
Afin d’éviter les effets potentiels sur l’environnement et la santé humaine résultant de la présence de substances dangereuses dans les équipements électriques et électroniques, les utilisateurs finaux d’équipements électriques et électroniques devraient comprendre la signification du symbole du bac à roulettes barré. Ne jetez pas les WEEE en tant que déchets municipaux non triés et devez les collecter séparément.
17

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

PLANET User Manuals

Related Manuals