Robertshaw RS8110 Non Programmable Thermostat Instruction Manual

August 28, 2024
Robertshaw

Robertshaw RS8110 Non Programmable Thermostat

Specifications

  • Model: RS8110
  • Power Supply: 24 VAC
  • Battery Type: AAA Alkaline
  • Warranty: 6 Year Limited Warranty

Product Usage Instructions

  • The thermostat has an LCD, fan switch, system switch, temperature set-point buttons, and an easy-change battery door for convenience.
  • To access the battery compartment, press the lower portion of the thermostat to open the battery door.
  • Install two AAA Alkaline batteries ensuring the correct alignment of the positive ends with the terminals in the compartment.
  • Replace the batteries immediately when the low battery indicator appears to prevent system malfunction.

Adjusting the Temperature Differential

  • Details on adjusting the temperature differential are not provided in this section. Refer to the detailed user manual for specific instructions.

FAQ

  • Q: How do I know when to replace the batteries?
  • A: Replace the batteries immediately when the low battery indicator appears on the display to avoid system malfunction.
  • Q: What should I do if my heating and cooling system becomes inoperable?
  • A: Check the battery compartment and replace the batteries with new AAA Alkaline ones. Ensure proper alignment of the battery terminals.

Caution

  • Do not switch the system to cool if the temperature is below 50°F (10°C).
  • This can damage the air conditioning system and cause personal injury.

THERMOSTAT OPERATION

  1. LCD Display

  2. Fan Switch

  3. System Switch

  4. Temperature Set-Point Buttons

  5. Easy change battery door

  6. LCD Screen
    See page 6 for detailed information.

  7. Fan Switch
    Select ON or AUTO. ON will run the fan continuously. AUTO will turn the fan on only in a call for heating or cooling.

  8. System Switch
    Select HEAT or COOL for your HVAC system. Selecting HEAT turns on the heat mode. Selecting COOL turns on the cool mode. Selecting OFF turns both heating and cooling off.

  9. Temperature Set-Point Buttons
    Press the to select the desired temperature.

  10. Easy change battery door
    for details.

THERMOSTAT QUICK REFERENCE

Battery Door Information

Caution

  • When the low battery icon appears replace your 2x AAA batteries immediately.
  • Failure to do so may result in your heating and cooling system becoming inoperable.
  • Freezing or overheating can occur.

THERMOSTAT QUICK REFERENCE

ADJUSTING THE TEMPERATURE DIFFERENTIAL

COOLING DIFFERENTIAL OR SWING.
The cooling differential is factory preset at 0.5°. This means that whenever the room temperature heats by 0.5° from the temperature setting, the cooling system will turn on. If the cooling system turns on too often, increase the temperature differential. To access the COOL SWING setting and adjust the cooling differential, select COOL and hold down together for 3 seconds. Use to adjust the cooling differential from between 0.2°F and 2°F. Wait approximately 15 seconds or toggle the system switch to return to normal operation.

HEATING DIFFERENTIAL OR SWING.
The heating differential is factory preset at 0.4°. This means that whenever the room temperature cools by 0.4° from the temperature setting, the heating system will turn on. If the heating system turns on too often, increase the temperature differential. To access the HEAT SWING setting and adjust the heating differential, select HEAT and hold it down together for 3 seconds. Use to adjust the heating differential from between 0.2°F and 2°F. Wait approximately 15 seconds or toggle the system switch to return to normal operation.

CALIBRATION SETTING

To access the CALIBRATION setting and adjust the temperature, select OFF and hold down together for 3 seconds. Use to adjust the temperature from between -4°F and +4°F.
Press to select F (Fahrenheit) or C (Celsius), and press to select the temperature scale.
Then press – to access the compressor short cycle DELAY setting. If the compressor short cycle delay setting is ON, the compressor cannot be turned on for at least 3 minutes after it was last turned off. Use to adjust the compressor short cycle delay setting to ON or OFF. Wait approximately 15 seconds or toggle the system switch to return to normal operation.

TERMINAL DESIGNATIONS

  • RH………….24 VAC (system power supply) HEAT
  • RC………….24 VAC (system power supply) COOL
  • C…………….Common 24 VAC (system power supply)
  • W……………HEAT
  • Y…………….COOL
  • G…………….FAN
  • B…………….REV VALVE HEAT
  • O…………….REV VALVE COOL

CONTACT

  • Customer Service +1.800.304.6563Technical Service +1.800.445.8299
  • HVACCustomerService@robertshaw.com. www.robertshaw.com
  • 0016YearLimited WarrantyUse Phone to Scan for Warranty Info
  • 352-00309-001 Rev. B
  • © 2021 Robertshaw Controls Company.
  • Robertshaw® is a trademark of Robertshaw Controls Company.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals