QUICKSTART e-360 allows you two mounting configurations, depending on your preferences and the space available in your installation:
Compact Installation Sketch
The cell and the electronic control unit are assembled.
- Optional BY-PASS
Independent cell installation sketch
-
The cell and the electronic control unit are assembled separately.
-
Hang the control unit to the wall with the rear brackets, and use the approved cable extender (An additional option to the standard equipment).
-
Optional BY-PASS
Protocol of Installation
- Installation has to be done with the unit switched off and disconnected from the energy network.
Control Unit installation:
- (a) Be sure that heat-dissipating elements are free to permit air circulation.
- (b) Avoid direct sunlight.
- (c) Use the unit connected to the ground kit.
CELL INSTALLATION:
- (a) The orientation of the cell must always be vertical. The tab marked in the following image is facing the opposite side of the wall.
- (b) On the inside of the cell, there are two deflectors IN and OUT. Choose the correct position depending on your hydraulic installation.
- (c) Put the cell in place, making sure that the junction joints are correctly positioned.
- Note: The arrow in the previous image indicates the correct water flow direction.
- (d) Place and tighten the locking clips between the connectors and the cell inlet/outlet.
- (e) Check that the cell is properly installed inside the housing.
Mounting A (cell and control unit mounted together):
- a) Insert the control unit into the front housing of the cell.
- b) Connect the 3 cables.
- c) Attach the top cover and firmly tighten the 3 threaded knobs.
Mounting B (control unit hanging on the wall):
- a) Install the control unit on the wall.
- b) Connect the extension cable (an additional option, not included in the standard product) between the cell cables and the control unit cables.
- c) Put on the top cover of the cell and firmly tighten the 3 threaded knobs.
Note: The orientation of the cell must always be vertical.
Note: Before electrical installation, check for water loss leaking.
ELECTRICAL INSTALLATION
Disconnect the power supply from the control panel before handling it.
- (a) It is very important to ensure that the ground connection is in good condition.
- (b) Check that you have the appropriate protection elements: Magnetothermic, differential switch, and motor protection for the filtration pump.
- (c) Connect the equipment power cable to the panel, respecting the phase, neutral, and ground connections.
Note: The electrical connection must be made in such a way that the QUICKSALT chlorinator is started only when the filtration pump is in operation.
Protocol – Unit start-up
- Unit installed. Switch off the unit:
- Basic water treatment: Modify the values of the main parameters of water. The appropriated values are indicated in the following table.
- Salt loading. Introduce the salt directly into the swimming pool and maintain the filtering running for 24 hours.
- Chlorine buffer production: Switch on the unit for 24 hours.
- Introduction of standard filtering time: Define the usual filtering time. BSV recommends 8 hours of filtering time.
- Disinfection customizing: It is possible to modify the production level depending on the user preferences. BSV recommends maintaining 0,5 to 2,5 ppm of FCL in the water.
FAQs
- Q: What should I do if I encounter issues during unit start-up?
- A: Refer to the troubleshooting section in the user manual or contact customer support for assistance.
- Q: How do I maintain the optimal pH level in the water?
- A: Check the recommended pH level in the manual and adjust using appropriate chemicals as needed.
CONTACT INFOMATION
- Avda. De las Américas, 10/2 Modulo C.
- 30820 Alcantarilla
- Murcia (Spain)
- Tel (+34) 93 861 51 15 .
- Fax (+34) 93 861 52 99