National PXIe-5774 Channel 6.4 GS s DC 3 GHz Kintex UltraScale User Guide

August 23, 2024
NATIONAL

National PXIe-5774 Channel 6.4 GS s DC 3 GHz Kintex UltraScale

National-PXIe-5774-Channel-6.4-GS s DC-3-GHz-Kintex-UltraScale-
PRODUCT

Product Usage Instructions

Verifying the System Requirements
To use the PXIe-5774, ensure your system meets the minimum requirements. Check the readme file for detailed information or visit ni.com/manuals.

Unpacking the Kit

  1. Ground yourself to prevent electrostatic discharge. Touch the antistatic package to a metal part of the computer chassis.
  2. Carefully inspect the device for any damage or loose components after removing it from the package.
  3. Unpack all included items and documentation from the kit.
  4. Store the device in the antistatic package when not in use.

Preparing the Environment
Ensure the operating environment meets specified conditions such as ambient temperature, humidity, altitude, and pollution degree. Refer to the specifications document at ni.com/manuals for detailed information.

Getting Started Guide

This document explains how to install, configure, test, and use the PXIe-5774. You can program the PXIe-5774 with the following software options.

  • FlexRIO driver software
  • NI LabVIEW Instrument Design Libraries for FlexRIO (instrument design libraries)

Note Before you begin, install and configure your chassis and controller.

Note Adapter modules are not installable or interchangeable on the PXIe-5774.

© 2019–2021 National Instruments Corporation. All rights reserved. Refer to the \_Legal Information directory for information about NI copyright, patents, trademarks, warranties, product warnings, and export compliance.

FlexRIO Documentation and Resources
Table 1. FlexRIO Documentation and Resources

Document/Resource Location Description
PXIe-5774 Getting Started Guide (this document) Available at
ni.com/manuals. Contains installation

instructions and basic programming instructions for your PXIe-5774.
PXIe-5774 Specifications| Available at ni.com/manuals.| Contains specifications for your PXIe-5774.
PXIe-5774 Safety, Environmental, and Regulatory Information| Available at ni.com/manuals.| Contains important safety, environmental, and regulatory information for your PXIe-5774.
LabVIEW FPGA Module Help| Embedded in LabVIEW Help

and at ni.com/manuals.

| Contains information about the basic functionality of the LabVIEW FPGA Module.
Document/Resource| Location| Description
---|---|---
FlexRIO Help| Available at ni.com/manuals.| Contains information about the FPGA module front panel connectors and I/O, programming instructions, and I/O component-level IP (CLIP).
LabVIEW Examples| Available in NI Example Finder.

InxLaambVpIlEeWs, cHlicakrdHwelapre» FIninpdut

»

and Output » FlexRIO.

| Contains examples of how to run FPGA VIs and Host VIs on your FlexRIO devices.
FlexRIO product page| Located at ni.com/flexrio.| Contains product information and data sheets for FlexRIO hardware.

Verifying the System Requirements

To use the PXIe-5774, your system must meet certain requirements. For more information about minimum system requirements, recommended system, and supported application development environments (ADEs), refer to the readme, which is installed or available at ni.com/manuals.

Unpacking the Kit

Notice To prevent electrostatic discharge (ESD) from damaging the device, ground yourself using a grounding strap or by holding a grounded object, such as your computer chassis.

  1. Touch the antistatic package to a metal part of the computer chassis.

  2. Remove the device from the package and inspect the device for loose components or any other sign of damage.
    Notice Never touch the exposed pins of connectors.
    Note Do not install a device if it appears damaged in any way.

  3. Unpack any other items and documentation from the kit. Store the device in the antistatic package when the device is not in use.

PXIe-5774 Kit Contents

The following items are included in the device kit:

  • PXIe-5774
  • Documentation:
    • PXIe-5774 Getting Started Guide (this document)
    • PXIe-5774 Safety, Environmental, and Regulatory Information

Preparing the Environment
Ensure the environment in which you are using the PXIe-5774 meets the following specifications.

Operating environment

Ambient temperature range| 0 °C to 55 °C[1]
Relative humidity range| 10% to 90%, noncondensing
Maximum altitude| 2,000 m (800 mbar) (at 25 °C ambient temperature)
Pollution Degree| 2

Note For complete specifications, refer to the specifications document for your device at ni.com/manuals.

Installing the Software and Driver Using NI Package

Manager
Before installing your hardware, you must install the application software and instrument driver. Install the software in the following order:

  1. Install LabVIEW. Refer to the LabVIEW Installation Guide for installation instructions for LabVIEW and system requirements for the LabVIEW software. Refer to the ©LabVIEW Upgrade Notes for additional information about upgrading to the most recent version of LabVIEW for Windows. Documentation for LabVIEW is available at ni.com/manuals.
  2. Install the LabVIEW FPGA Module. Refer to the LabVIEW FPGA Module Release and Upgrade Notes for installation instructions and information about getting started with the LabVIEW FPGA Module. Documentation for the LabVIEW FPGA Module is available at ni.com/manuals.
  3. (Optional) Install the LabVIEW Real-Time Module. Refer to the LabVIEW Real-Time Module Release and Upgrade Notes for system requirements, installation instructions, and additional information about using the LabVIEW Real-Time Module.
  4. Install FlexRIO. Refer to the FlexRIO Readme for system requirements and installation instructions for FlexRIO. Documentation for FlexRIO is available at ni.com/manuals.

Installing the PXIe-5774

Notice To prevent damage to the PXIe-5774 caused by ESD or contamination, handle the module using the edges or the metal bracket.

  1. Ensure the AC power source is connected to the chassis before installing the module. The AC power cord grounds the chassis and protects it from electrical damage while you install the module.

  2. Power off the chassis.

  3. Inspect the slot pins on the chassis backplane for any bends or damage prior to installation. Do not install a module if the backplane is damaged.

  4. Remove the black plastic covers from all the captive screws on the module front panel.

  5. Identify a supported slot in the chassis. The following figure shows the symbols that indicate the slot types.
    Chassis Compatibility SymbolsNational-PXIe-5774-Channel-6.4-GS s DC-3
-GHz-Kintex-UltraScale-FIG- \(1\)

  6. PXI Express System Controller Slot

  7. PXI Peripheral Slot

  8. PXI Express Hybrid Peripheral Slot

  9. PXI Express System Timing Slot

  10. PXI Express Peripheral Slot
    PXIe-5774 modules can be placed in PXI Express peripheral slots, PXI Express hybrid peripheral slots, or PXI Express system timing slots.

  11. Touch any metal part of the chassis to discharge static electricity.

  12. Ensure that the ejector handle is in the downward (unlatched) position.

  13. Place the module edges into the module guides at the top and bottom of the chassis. Slide the module into the slot until it is fully inserted.
    Module Installation

  14. Chassis

  15. Hardware Module

  16. Ejector Handle in Downward (Unlatched) Position

  17. Latch the module in place by pulling up on the ejector handle.

  18. Secure the module front panel to the chassis using the front-panel mounting screws.
    Note Tightening the top and bottom mounting screws increases mechanical stability and also electrically connects the front panel to the chassis, which can improve the signal quality and electromagnetic performance.

  19. Cover all empty slots using either filler panels (standard or EMC) or slot blockers with filler panels, depending on your application.
    Note For more information about installing slot blockers and filler panels, go to ni.com/r/pxiblocker.

  20. Power on the chassis.

Installing the Ferrite on the DIO Cable

Notice To ensure the specified EMC performance, install the snap-on ferrite bead (National Instruments part number 781233-02) in accordance with these instructions.

  1. Open the ferrite bead and place the cable inside the center of the bead. Ensure the ferrite bead is as close to where the cable connects to the PXIe-5774 as practical.
  2. Close the ferrite bead until the locking tabs engage securely.

Snap-On Ferrite Bead Installation

  1. Molex™ Nano-Pitch I/O™ connector
  2. Ferrite

PXIe-5774 Front Panel and Pinout

Front Panel
The following figure shows the PXIe-5774 front panel.

National-PXIe-5774-Channel-6.4-GS s DC-3-GHz-Kintex-UltraScale-FIG-
\(3\)The following table describes the signal connections for the PXIe-5774

Connector Description Function
DIO Molex Nano-Pitch DIO connector Multi-signal DIO connector that provides

access to FPGA multi- gigabit transceivers (MGTs) and general-purpose LVCMOS signals.
AI 0| Standard SMA female connector| Analog input connection.
AI 1
REF/CLK IN| Standard SMA female connector| Input for an external Reference Clock or Sample Clock.
TRIG IN| Standard SMA female connector| Analog IN trigger.
Connector| Description| Function
---|---|---
TRIG OUT| Standard SMA female connector| Digital OUT trigger.

Digital I/O Pinout
The following figure shows the Digital I/O (DIO) connector pinout.

Signal Type Direction
MGT Tx± <0..3> Xilinx UltraScale GTH Output
MGT Rx± <0..3> Xilinx UltraScale GTH Input
DIO <0..7> Single-ended Bidirectional
5.0 V DC Output
GND Ground

Notice The maximum input signal levels are valid only when the module is powered on. To avoid permanent damage to the PXIe-5774, do not apply a signal to the device when the module is powered down.

Notice Connections that exceed any of the maximum ratings of any connector on the PXIe-5774 can damage the device and the system. NI is not liable for any damage resulting from such connections.

Configuring the PXIe-5774 in MAX

Use Measurement & Automation Explorer (MAX) to configure your NI hardware. MAX informs other programs about which NI hardware products are in the system and how they are configured. MAX is automatically installed with FlexRIO.

  1. Launch MAX.
  2. In the configuration tree, expand Devices and Interfaces to see the list of installed NI hardware. Installed modules appear under the name of their associated chassis.
  3. Expand your Chassis tree item. MAX lists all modules installed in the chassis. Your default names may vary. Note If you do not see your module listed, press to refresh the list of installed modules. If the module is still not listed, power off the system, ensure the module is correctly installed, and restart.
  4. Record the identifier MAX assigns to the hardware. Use this identifier when programming the PXIe-5774.
  5. Self-test the hardware by selecting the item in the configuration tree and clicking Self-Test in the MAX toolbar.

The MAX self-test performs a basic verification of hardware resources.

FlexRIO Examples
FlexRIO includes several example applications for LabVIEW. These examples serve as interactive tools, programming models, and as building blocks in your own applications.

Accessing FlexRIO Examples
FlexRIO examples are available in LabVIEW’s NI Example Finder. Complete the following steps to access the examples by task.

1. In LabVIEW, click Help » Find Examples.
2. In the NI Example Finder window that appears, click Hardware Input and Output » FlexRIO.

Click on an example and refer to the Information window for a description of the example. Refer the Requirements window for a list of hardware that can run the example. You can also click the Search tab to search all installed examples by keyword. For example, search for FlexRIO to locate all FlexRIO examples. Online examples are also available to demonstrate FlexRIO basics, such as using DRAM, acquiring data from adapter modules, and performing high throughput streaming. To access these examples, search FlexRIO examples in the Search the community field at ni.com/examples.

Block Diagrams

Carrier Block Diagram (KU040 and KU060)

National-PXIe-5774-Channel-6.4-GS s DC-3-GHz-Kintex-UltraScale-FIG-
\(4\)

PXIe-5774 Block Diagram

National-PXIe-5774-Channel-6.4-GS s DC-3-GHz-Kintex-UltraScale-FIG-
\(5\)

Component-Level Intellectual Property (CLIP)

The LabVIEW FPGA Module includes component-level intellectual property (CLIP) for HDL IP integration. FlexRIO devices support two types of CLIP: user- defined and socketed.

  • User-defined CLIP allows you to insert HDL IP into an FPGA target, enabling VHDL code to communicate directly with an FPGA VI.
  • Socketed CLIP provides the same IP integration of the user-defined CLIP, but it also allows the CLIP to communicate directly with circuitry external to the FPGA. Adapter module socketed CLIP allows your IP to communicate directly with both the FPGA VI and the external adapter module connector interface.

The PXIe-5774 ships with socketed CLIP items that add module I/O to the LabVIEW project.

Making a Measurement with LabVIEW

  1. Launch LabVIEW.
  2. Select Help » Find Example.
  3. Open the example VI that you want to use by selecting Hardware Input and Output » FlexRIO.
  4. Follow any setup, configuration, and execution instructions in the VI.

Troubleshooting

If an issue persists after you complete a troubleshooting procedure, search our KnowledgeBase for additional information our technical support engineers create as they answer common user questions and resolve unexpected issues.

What Should I Do if the PXIe-5774 Does Not Appear in MAX?

  1. In the MAX configuration tree, expand Devices and Interfaces.
  2. Expand the Chassis tree to see the list of installed hardware, and press to refresh the list.
  3. If the module is still not listed, power off the system, ensure that all hardware is correctly installed, and restart the system.
  4. Navigate to the Device Manager by right-clicking the Start button, and selecting Device Manager.
  5. Verify the PXIe-5774 appears in the Device Manager.
  6. Under an NI entry, confirm that a PXIe-5774 entry appears. Note If you are using a PC with a device for PXI remote control system, under System Devices, also confirm that no error conditions appear for the PCI-to-PCI Bridge.
  7. If error conditions appear, reinstall the FlexRIO driver.

What Should I Do if the PXIe-5774 Fails the Self-Test?

  1. Restart the system.
  2. Launch MAX, and perform the self-test again.
  3. Power off the chassis.
  4. Reinstall the failed module in a different slot.
  5. Power on the chassis.
  6. Perform the self-test again.

Where to Go Next
Refer to the following figure for information about other product tasks and associated resources for those tasks.

NI Services

  • Visit ni.com/support to find support resources including documentation, downloads, and troubleshooting and application development self-help such as tutorials and examples.
  • Visit ni.com/services to learn about NI service offerings such as calibration options, repair, and replacement.
  • Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI.

NI corporate headquarters is located at 11500 N Mopac Expwy, Austin, TX, 78759-3504, USA.

FAQ

Q: What software options can be used to program the PXIe-5774?
A: The PXIe-5774 can be programmed using FlexRIO driver software and NI LabVIEW Instrument Design Libraries for FlexRIO (instrument design libraries).

Q: How can I prevent damage from electrostatic discharge when unpacking the kit?
A: Ground yourself using a grounding strap or by touching a grounded object before handling the device. Avoid touching exposed pins of connectors.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

NATIONAL User Manuals

Related Manuals