Specifications
-
Power options: 802.3at/802.3bt PoE
-
Dimensions: 215mm x 215mm x 64mm (8.46in x
8.46in x 2.52in) -
Weight: Operating temperature
-
Operating humidity: Operating altitude
Electromagnetic emissions I/O -
RF:
-
Maximum PHY rate Indicators:
-
Operating altitude: 3,048m (10,000 ft)
-
Electromagnetic emissions: FCC Part 15 Class
B -
I/O: Multi-color status LED
-
Safety standards: CSA 62368-1 CAN/CSA-C22.2
No. 62368-1-19 ICES-003:2020 Issue 7, Class B (Canada)
Product Usage Instructions
AP64 Mounting
There are two mounting options available for the AP64:
-
Flush Mount Bracket: Instructions for
installing the AP64 using the flush mount bracket. -
Articulating Mount Bracket: Instructions for
installing the AP64 using the articulating mount bracket.
I/O Ports
The AP64 features the following I/O port:
- ETH0/PoE IN: 100/1000/2500BASE-T RJ45
interface that supports 802.3at/802.3bt PoE PD. Ensure proper
grounding by connecting to Earth ground using an 8AWG or larger
diameter wire.
FAQ
What power options does the AP64 support?
The AP64 supports 802.3at/802.3bt PoE power options.
What is included in the box with the AP64?
The AP64 comes with the following items: 1. AP64 Access Point,
2. APOUTBR-FM2 Flush mount bracket, 3. RJ45 cable gland.
“`
AP64 Hardware Installation Guide
Overview
The AP64 contains three IEEE 802.11ax radios that deliver 2×2 MIMO with two
spatial streams when operating in multi-user (MU) or single-user (SU) mode.
The AP64 can operate simultaneously in the 6GHz band, 5GHz band, and 2.4GHz
band or two bands and a dedicated tri-band scan radio.
1 Juniper Business Use Only AP64 Hardware Installation Guide Juniper Networks
(C) Copyright 2023. All Rights Reserved
I/O ports
ETH0/PoE IN
100/1000/2500BASE-T RJ45 interface that supports 802.3at/802.3bt PoE PD
Ground should be connected to Earth ground using wire that is 8AWG or larger diameter.
2 Juniper Business Use Only
AP64 Hardware Installation Guide Juniper Networks (C) Copyright 2023. All
Rights Reserved
AP64 Mounting
Flush Mount Bracket
Articulating Mount Bracket
3 Juniper Business Use Only AP64 Hardware Installation Guide Juniper Networks
(C) Copyright 2023. All Rights Reserved
4 Juniper Business Use Only
AP64 Hardware Installation Guide Juniper Networks (C) Copyright 2023. All
Rights Reserved
5 Juniper Business Use Only
AP64 Hardware Installation Guide Juniper Networks (C) Copyright 2023. All
Rights Reserved
6 Juniper Business Use Only
AP64 Hardware Installation Guide Juniper Networks (C) Copyright 2023. All
Rights Reserved
Technical Specifications:
Feature
Description
Power options
802.3at/802.3bt PoE
Dimensions
215mm x 215mm x 64mm (8.46in x 8.46in x 2.52in)
Weight
Operating temperature
Operating humidity
AP64: 1.50 kg (3.31 lbs) AP64: -40° to 65° C without solar loading AP64: -40° to 55° C with solar loading 10% to 90% maximum relative humidity, non- condensing
Operating altitude Electromagnetic emissions I/O
RF
Maximum PHY rate Indicators
3,048m (10,000 ft)
FCC Part 15 Class B
1 100/1000/2500BASE-T auto-sensing RJ-45 with PoE
2.4GHz or 6GHz – 2×2:2SS 802.11ax MU-MIMO & SU-MIMO 5GHz – 2×2:2SS 802.11ax
MU-MIMO & SU-MIMO 1×1: 1SS 802.11ax 2.4GHz/5GHz/6GHz scan 2.4GHz BLE with
Antenna Zigbee: 802.15.4 Thread: 802.15.4 Total maximum PHY rate 3600 Mbps
6GHz 2400 Mbps 5GHz 1200 Mbps 2.4GHz 600 Mbps
Multi-color status LED
Safety standards
CSA 62368-1 CAN/CSA-C22.2 No. 62368-1-19 ICES-003:2020 Issue 7, Class B (Canada)
7 Juniper Business Use Only
AP64 Hardware Installation Guide Juniper Networks (C) Copyright 2023. All
Rights Reserved
Warranty Information
The AP64 family of Access Points comes with a one-year limited warranty.
Included in the box: 1. AP64 2. APOUTBR-FM2 3. RJ45 cable gland
Ordering Information:
Access Points: AP64-US
AP64-WW
802.11ax WiFi6E 2+2+2 AP Internal Antenna for the US Regulatory domain
802.11ax WiFi6E 2+2+2 AP Internal Antenna for the WW Regulatory domain
Mounting bracket included in the box:
APOUTBR-FM2
Flush mount bracket for AP
Optional accessory bracket: APOUTBR-ART2
Articulating mount for AP
Power Supply options: 802.3at or 802.3bt PoE power
8 Juniper Business Use Only
AP64 Hardware Installation Guide Juniper Networks (C) Copyright 2023. All
Rights Reserved
Regulatory Compliance Information:
If you need further assistance with purchasing the power source, please
contact Juniper Networks, Inc.
9 Juniper Business Use Only AP64 Hardware Installation Guide Juniper Networks
(C) Copyright 2023. All Rights Reserved
FCC Requirement for Operation in the United States of America:
FCC Part 15.247, 15.407, 15.107, and 15.109
FCC Guideline for Human Exposure This equipment complies with FCC radiation
exposure limits set forth for an uncontrolled environment. This equipment
should be installed and operated with minimum distance between the radiator &
your body; AP64 20cm
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one of the
following measures:
Reorient or relocate the receiving antenna. Increase the separation between
the equipment and receiver. Connect the equipment into an outlet on a circuit
different from that to which the
receiver is connected. Consult the dealer or an experienced radio/TV
technician for help.
FCC Caution Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this
equipment. This transmitter must not be co-located or operating in conjunction
with any other antenna or transmitter. The 5.925 ~ 7.125GHz operation of this
device is prohibited on oil platforms, cars, trains, boats, and aircraft,
except that operation of this device is permitted in large aircraft while
flying above 10,000 feet. Operation of transmitters in the 5.925-7.125 GHz
band is prohibited for control of or Communications with unmanned aircraft
systems.
10 Juniper Business Use Only AP64 Hardware Installation Guide Juniper Networks
(C) Copyright 2023. All Rights Reserved
Industry Canada
This device contains license-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s license-exempt
RSS(s). Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired
operation.
Cet appareil contient des émetteurs / récepteurs exempts de licence qui sont
conformes au (x) RSS (s) exemptés de licence d’Innovation, Sciences et
Développement économique Canada. L’opération est soumise aux deux conditions
suivantes: (1) le dispositif ne doit pas produire de brouillage préjudiciable,
et (2) ce dispositif doit accepter tout brouillage reçu, y compris un
brouillage susceptible de provoquer un fonctionnement indésirable.
IC Caution
(i) The maximum antenna gain permitted for devices in the bands 5250-5350 MHz
and 5470-5725 MHz shall be such that the equipment still complies with the
e.i.r.p. limit; (ii) The maximum antenna gain permitted for devices in the
band 5725-5850 MHz shall be such that the equipment still complies with the
e.i.r.p. limits specified for point-topoint and non-point-to-point operation
as appropriate; and (iii) Operation on oil platforms, cars, trains, boats and
aircraft shall be prohibited except for on large aircraft flying above 10,000
ft. (iv) Devices shall not be used for control of or communications with
unmanned aircraft systems. (v) The device for operation in the band 5150-5250
MHz is only for indoor use to reduce the potential for harmful interference to
co-channel mobile satellite systems. (vi) The transmitter module may not be
co-located with any other transmitter or antenna.
Avertissement (i) le gain maximal d’antenne permis pour les dispositifs
utilisant les bandes de 5250 à 5 350 MHz et de 5470 à 5725 MHz doit être
conforme à la limite de la p.i.r.e; (ii) le gain maximal d’antenne permis
(pour les dispositifs utilisant la bande de 5 725 à 5 850 MHz) doit être
conforme à la limite de la p.i.r.e. spécifiée pour l’exploitation point à
point et l’exploitation non point à point, selon le cas; (iii) Utilisation
interdite à bord de plateformes de forage pétrolier, de voitures, de trains,
de bateaux et d’aéronefs, sauf à bord d’un gros aéronef volant à plus de 10
000 pieds d’altitude. (iv) Les dispositifs ne doivent pas être utilisés pour
commander des systèmes d’aéronef sans pilote ni pour communiquer avec de tels
systèmes.
11 Juniper Business Use Only AP64 Hardware Installation Guide Juniper Networks
(C) Copyright 2023. All Rights Reserved
(v) Les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés
uniquement pour une utilisation à l’intérieur afin de réduire les risques de
brouillage préjudiciable aux systèmes de satellites mobiles utilisant les
mêmes canaux. (vi) Le module émetteur peut ne pas être coïmplanté avec un
autre émetteur ou antenne.
Radiation Exposure Statement:
This equipment complies with IC RSS-102 radiation exposure limits set forth
for an uncontrolled environment. This equipment should be installed and
operated with minimum distance 20cm (AP64) between the radiator & your body.
Cet équipement est conforme aux limites d’exposition aux rayonnements IC
établies pour un environnement non contrôlé. Cet équipement doit être installé
et utilisé avec un minimum de 20cm (AP64) de distance entre la source de
rayonnement et votre corps.
12 Juniper Business Use Only AP64 Hardware Installation Guide Juniper Networks
(C) Copyright 2023. All Rights Reserved
CE
Hereby, Juniper Networks, Inc. declares that the radio equipment type (AP64) is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following: https://www.mist.com/support/
The frequency and maximum transmitted Power in EU:
Bluetooth/Thread/Zigbee: Frequency range (MHz) 2400 2483.5
Maximum EIRP in EU (dBm) 8.45
WLAN:
Frequency range (MHz)
2400 2483.5 5150 5250 5250 5350 5500 5700 5745 5825 5945 6425
Maximum EIRP in EU (dBm) 19.97 22.97 22.97 29.96 13.97 22.97
This equipment complies with EU radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
The device is restricted to indoor use only when operating in 5150 to 5350 MHz and 5945 to 6425MHz frequency ranges.
AT BE BG CZ DK EE FR DE IS IE IT EL ES CY LV LI LT LU HU MT NL NO PL PT RO SI SK TR FI SE CH HR UK(NI)
13 Juniper Business Use Only
AP64 Hardware Installation Guide Juniper Networks (C) Copyright 2023. All
Rights Reserved
UK
Hereby, Juniper Networks, Inc. declares that the radio equipment type (AP64)
is in compliance with Radio Equipment Regulations 2017. The full text of the
UK declaration of conformity is available at the following:
https://www.mist.com/support/
The frequency and maximum transmitted Power in UK:
Bluetooth: Frequency range (MHz) 2400 2483.5
Maximum EIRP in UK (dBm) 8.45
WLAN:
Frequency range (MHz)
2400 2483.5 5150 5250 5250 5350 5500 5700 5745 5825 5925 6425
Maximum EIRP in UK (dBm) 19.97 22.96 22.96 29.74 22.98 22.97
This equipment complies with UK radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
The device is restricted to indoor use only when operating in 5150 to 5350 MHz and 5945 to 6425MHz frequency ranges.
UK(NI)
14 Juniper Business Use Only
AP64 Hardware Installation Guide Juniper Networks (C) Copyright 2023. All
Rights Reserved
Japan
AP64 Access Point is restricted to indoor use only when operating in
5150-5350MHz and 5925 to 6425MHz frequency ranges.
Taiwan
NCC (LP0002)
15 Juniper Business Use Only AP64 Hardware Installation Guide Juniper Networks
(C) Copyright 2023. All Rights Reserved
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>