WANDFLUH M.Z45 Solenoid Coil Instruction Manual
- August 13, 2024
- WANDFLUH
Table of Contents
WANDFLUH M.Z45 Solenoid Coil
Specifications
- Type: M.Z45-.-.
- Coil Resistance: 100 – 152 Ohms
- Temperature Range: Not specified
- Equipment Group: M224, M238
- Design-Index: Subject to change
Product Information
The Solenoid coil MKZ45 and MDZ45 are designed for specific applications and come with installation and operating instructions for proper setup and use. The coils are manufactured by Wandfluh AG and are suitable for various industrial uses.
Installation Instructions
- Ensure authorized personnel handle the installation.
- Choose the appropriate solenoid coil type for your application in consultation with Wandfluh AG or their representatives.
- Follow the provided connection terminal instructions for proper setup.
- Integrate the solenoid coil into the potential equalization of the overarching installation to maintain explosion protection.
Operating Instructions
Once installed, follow these operating instructions:
- Only operate the solenoid coil within the specified temperature range.
- Ensure the coil is connected to certified intrinsically safe electric circuits for explosion protection.
- Observe all safety guidelines provided in the manual.
FAQ
Q: Can I use the solenoid coil without following the installation
instructions?
A: No, it is crucial to follow the installation instructions provided to
ensure safe and proper operation of the solenoid coil.
Q: What should I do if I encounter difficulties during installation?
A: If you face any challenges during installation, contact Wandfluh AG or
their representatives for assistance.
Overall view
1 Type Designations
Safety
Use in line with the intended purpose
Solenoid coils of the types MKZ45-.-., installed on an armature tube, are
foreseen for he actuation of valves in explosion hazard areas. The solenoid
coils are constructed in the ignition protection class «intrinsically safe»
and have type examination certifications in accordance with ATEX, UKEX, IECEx
und CCC. The solenoid coils are foreseen for operation with intrinsically safe
electric power supplies.
Installation conditions and operating conditions have to be observed.
The solenoid coil type suitable for the application should be selected
together with the manufacturer Wandfluh AG Frutigen or his representatives.
Authorised Persons
The work described here must only be carried out by qualified persons.
Qualified are persons who have been at least «electro-technically instructed»
(equivalent to EN 60 204).
About these installation and operating instructions These installation and
operating instructions are a component part of the product and have to be
integrated into the corresponding operating instructions of the superordinate
installations or machines.
General remarks about danger
The supply voltage must not exceed the values indicated under «technical
safety limit values».
For maintaining the explosion protection, the solenoid coil has to be
connected to certified intrinsically safe electric circuits.
For maintaining the explosion protection, the installation instructions have
to be observed. In particular, the solenoid coil has to be integrated in the
potential equalisation of the superordinate installation.
Guarantee
A safe operation without any problems is only assured, if the requirements of
these installation and operating instructions are completely adhered to.
Decisive for the assertion of legal rights is
the german language version. In case of non-observance, Wandfluh AG assumes no
liability.
Subject of technical changes and changes in the scope of delivery.
Explosion protection
Device group I, mining:
Solenoid coils of this execution may be utilised in explosion hazard areas in
accordance with the certifications:
Examination certificate | Certification | Ta min. | Ta max. |
---|---|---|---|
M238 | M224 | Standard | |
SEV 16 ATEX 0127 X CML 22UKEX2141X |
I M1 Ex ia I Ma
|
-60 °C
|
-40 °C
|
-25°C
|
+60 °C
IECEx SEV 16.0005X| Ex ia I Ma| -60 °C| -40 °C| -25°C| +60 °C
Device group II, other areas:
Solenoid coils of this execution may be utilised in explosion hazard areas in accordance with the certifications:
Examination certificate | Certification | Ta min. | Ta max. |
---|---|---|---|
M238 | M224 | Standard | |
SEV 16 ATEX 0127 X CML 22UKEX2141X | II 1 G Ex ia IIC T5 Ga | -60 °C | -40 °C |
-25°C | +60 °C | ||
II 1 G Ex ia IIC T6 Ga | -60 °C | -40 °C | -25°C |
IECEx SEV 16.0005X
| Ex ia IIC T5 Ga| -60 °C| -40 °C| -25°C| +60 °C
Ex ia IIC T6 Ga| -60 °C| -40 °C| -25°C| +45 °C
CCC:
| Ex ia IIC T5 Ga| -60 °C| -40 °C| -25°C| +45 °C
Ex ia IIC T6 Ga| -60 °C| -40 °C| -25°C| +45 °C
In case of applications in zone 0, the solenoid coil must only be connected to
intrinsically safe electric circuits of the category ia.
In case of applications in zones 1 and 2, the solenoid coil may be connected
to intrinsically safe electric circuits of the categories is and ib.
The technical safety limit values have to be complied with (refer to Technical
data).
Applications in zone 0
The solenoid valve has to be securely fixed, e.g., by means of a stable screw
connection to supporting elements, so that it cannot move even during
switching operations.
The installation conditions in accordance with EN-60079-14, section 12.3 have
to be complied with.
The solenoid valve or any parts of it must not be utilised as separating wall for the zone 0.
If supply lines are conducted through the separating wall of the zone 0 (e.g., for installation in reservoirs) the requirements of EN 60079-26, section 4.2.5 have to be complied with.
Technical data
The solenoid coil is foreseen for connection to intrinsically safe electric circuits with the following technical safety limit values:
Device group / I mining | Device group II / other areas | |
---|---|---|
Open-circuit voltage | Ui ≤ 30 V | Ui ≤ 30 V |
Short-circuit current | Ii ≤ 3,25 A | Ii ≤ 0,8 A |
Internal inductivity | ineffective , Li ≈ 0 | ineffective |
, Li ≈ 0
Innere Kapazität| ineffective , Ci ≈ 0| ineffective ,
Ci ≈ 0
Maximum power| Pi ≤ 7,0 W| Pi ≤ 3,0 W
Electrical operating values| In accordance with type designation
Operating time| 100 % (continuous operation)
Ambient temperature| See certification in the chapter explosion protection
Relative air humidity| Max. 95 % (not condensing)
Protection against contamination| IP65 according to EN 60 529 with
corresponding cable screw connection IP65
Operating conditions
Electric power supply
- Harmonic oscillations have no influence on the function, if the effective value of the sum total of all voltages corresponds to the nominal voltage.
- Admissible voltage pulses: Peak value ≤ 50 V
- The values permissible for voltage interruption/-undershooting are dependent on the device (possibly enquire from the manufacturer).
Electro-magnetic compatibility
- The solenoid coils do not produce any interference in accordance with EN 50081-1.
- The solenoid coils are not susceptible to interfering radiation in accordance with EN 64000-6-2.
- For line conducted interference, the indications for the power supply have to be observed.
Enhanced requirements
Solenoid coils in this execution are foreseen for utilisation in stationary
industrial hydraulics as well as in mobile hydraulics.
They have been successfully tested for temperature shock, vibration and mechanical shock.
Nonetheless the manufacturer does not guarantee the suitability and assumes no responsibility for the utilisation under extreme conditions.
Installation/commissioning/dismantling
Before starting, «Safety» and «General remarks about danger» have to have been read and understood.
Installation
Types M.Z45-…
- Slide the solenoid coil over the armature tube of the valve.
- Fix with retaining washer and nut.
- Tighten the nut until any turning or loosening of the solenoid coil due to jarring to be anticipated is not possible anymore.
Electrical connection works
Type MKZ45-…
- Open the cover of the connection housing with a suitable screwdriver.
- Connect the solenoid coil with a twin core cable, in doing so, pay close attention to the polarity, otherwise no function!
- Close the cover again and screw it on.
- Connect the solenoid coil with a grounding conductor at the external grounding connection.
- Depending on the cable/line entry, a separate strain relief must be provided for the connecting cable. Wandfluh Standard-KLE require a strain relief.
Type MBZ45-…
- The connection takes place with a three-pole bayonet connection in accordance with VG 95234. Recommended as socket type is: Type CA 310* E 10SL-3 SB*** of the company ITT Cannon.
- Connect the solenoid coil with a grounding conductor at the external grounding connection.
Type MDZ45-…
- The connection takes place with a three-pole connection in accordance with ISO 440/DIN 43650.
- Connect the solenoid coil with a grounding conductor at the external grounding connection, if applicable.
Type MGZ45-…
- The connection takes place with a two-pole connection DT04-2P/DT06-2S.
- Connect the solenoid coil with a grounding conductor at the external grounding connection.
Type MJZ45-…
- The connection takes place with a two-pole connection AMPJunior Timer.
- Connect the solenoid coil with a grounding conductor at the external grounding connection.
Dismantling
Types M.Z45-…
- Remove the connection cable.
- Unscrew the fixing nut and remove the solenoid coil from the armature tube.
Disposal
For the assurance of the explosion protection, solenoid coils must not be
repaired.
Dispose of in accordance with the directives of the respective country or else
return to the manufacturer.
EU/UK-Declaration of conformity
| | |
---|---|---|---
We| Wandfluh AG
Helkenstrasse 13
3714 Frutigen Switzerland
| Hereby declare in our sole responsibility, that the product| Solenoid coil
Type:|
M.Z45-.-.
| EU-type examination certificate:|
SEV 16 ATEX 0127 X
| UKEX-type examination certificate:|
CML 22UKEX2141X
| IECEx-type examination certificate:|
IECEx SEV 16.0005X
which is the subject of this declaration, is in conformity with the following
standards or normative documents:
Terms of the directive:| 2014/34/EU: ATEX-Richtlinie UKEX-Directive
2014/34/EU: Directive ATEX SI2016 Nr. 1107
2014/34/EU: ATEX Directive 2004/108/EG: EMV-Richtlinie 2004/108/EC: EMC Directive 2004/108/CE: Directive CEM
---|---
Number and date of issue of the standard:| EN IEC 60079-0: 2018
EN 60079-11: 2012
EN 50303: 2000 Kat. M1
EN 61000-6-2: 2001
EN 61000-6-4: 2001
Production quality assessment:| SEV 16 ATEX 4130 CH/SEV/QAR16.0001
22UKQAN15178
Issued by notified bodies:| Eurofins Electrosuisse 1258
Eurofins CML 2503
Place and date
Head of valve technology.
Director quality management dept.
E-mail: sales@wandfluh.com Seite