TROTEC BX50 MID Wattmeter Instructions

August 10, 2024
TROTEC

TROTEC BX50 MID Wattmeter

Product Information

Specifications

  • Power Consumption: 10 VA
  • Loss Power
  • Measurement Range Basic Current (lb)
  • Starting Current
  • Accuracy Class
  • Protection Class
  • Operating Conditions: 230 V AC, single-phase, 50/60 Hz
  • Storage Conditions
  • Pulse Frequency (LED)
  • Protection Class MID Certification
  • Weight: Approximately 155 g
  • Dimensions: Approximately 119 x 68 x 77 mm (with plug)
  • LCD with Backlight

Product Usage Instructions

  • Safety Instructions
    Before using the product, make sure you have understood all safety precautions mentioned in the manual.

  • Installation
    Follow the installation guidelines provided in the manual to ensure proper setup of the BX50 MID / BX50 MID F / BX50 MID C device.

  • Operation
    To operate the device, connect it to a suitable power source meeting the specified requirements. Use the controls as indicated in the manual for accurate readings.

  • Maintenance
    Regularly check the device for any signs of damage or wear. Keep the device clean and free from dust to maintain optimal performance.

FAQ

  • Q: Where can I download the current version of the operating manual and declaration of conformity?
    A: You can download the manual and declaration of conformity from the following link: https://hub.trotec.com/?id=43926

  • Q: What is the power consumption of the BX50 MID?
    A: The power consumption of the BX50 MID is 10 VA.

  • Q: What are the dimensions of the BX50 MID?
    A: The dimensions of the BX50 MID are approximately 119 x 68 x 77 mm (with plug).

Safety

Read this manual carefully before starting or using the device. Always store the manual near the device or its site of use.

Warning
Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire, and/or serious injury. Save all warnings and instructions for future reference.

  • The device is supplied with a warning sign. Before initial start-up, make sure to paste the corresponding warning sign in your local language over the one present at the rear of the device.
    • Do not plug in line!
    • For use in dry rooms only!
    • Voltage-free only with the plug disconnected!
    • Do not cover during operation!
  • Do not use the device in potentially explosive rooms or areas and do not install it there.
  • Do not use the device in an aggressive atmosphere.
  • Do not immerse the device in water. Do not allow liquids to penetrate the device.
  • Protect the device from permanent direct sunlight.
  • Do not cover the device! With a higher power input, the device will warm up. Covering the device may cause overheating and consequently may cause a fire!
  • Do not open the device.
  • Do not remove any safety signs, stickers, or labels from the device. Keep all safety signs, stickers, and labels in legible condition.
  • Check the device for potential damage before each application. Do not use any defective devices.
  • Do not connect several devices by plugging one into another.
  • Only operate the device in dry surroundings.
  • Please note that the device is only de-energized when the plug has been disconnected from the mains.
  • Observe the storage and operating conditions (see Technical data).

Intended use

  • Only use the device for measurements on circuits directly connected to the low-voltage grid via a plug connection, e.g. household appliances, portable electrical appliances, etc., whilst adhering to the technical data.
  • If you are in the position of measuring instrument operator or if you have been assigned by the measuring instrument operator to record measured values, you shall, depending on the intended purpose, register the usage of new or renewed measuring devices to your responsible calibration authority within 6 hours after the initial operation. For this purpose, it is best to use the central German control platform (www.eichamt.de).
  • On this website, you can find the PDF information file ‘Duty to give notice’ (“Infoblatt Anzeigepflicht”) which contains further useful information about the procedure.
  • Any use other than the intended use is regarded as misuse.

Reasonably foreseeable misuse
The device is not suitable for use with any type of extension cable. The device may not be used in potentially explosive atmospheres, when wet or very humid.

Personnel qualification
People who use this device must:

  • have read and understood the instructions, especially the Safety chapter.

Safety signs and labels on the device

Notice
Do not remove any safety signs, stickers, or labels from the device. Keep all safety signs, stickers, and labels in legible condition.

The following safety signs and labels are attached to the device:

For indoor use only

This symbol indicates the following:
Only use the device in dry interior spaces, not in outdoor areas.

Residual risks

  • Warning of electrical voltage

    • Electric shock due to insufficient insulation! Check the device for damages and proper functioning before each use.
    • If you detect damages, do not use the device any longer.
    • Do not use the device when either the device or your hands are damp!
    • Do not use the device when the battery compartment or the housing is open.
  • Warning of electrical voltage

    • There is a risk of a short circuit due to liquids penetrating the housing!
    • Do not immerse the device and the accessories in water. Make sure that no water or other liquids can enter the housing.
  • Warning of electrical voltage
    Work on the electrical components must only be carried out by an authorized specialist company!

  • Warning

    • Risk of suffocation!
      Do not leave the packaging lying around. Children may use it as a dangerous toy.
  • Warning
    The device is not a toy and does not belong in the hands of children.

  • Warning
    Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications!

  • Caution
    Keep a sufficient distance from heat sources.

  • Notice
    To prevent damage to the device, do not expose it to extreme temperatures, extreme humidity, or moisture.

  • Notice
    Do not use abrasive cleaners or solvents to clean the device.

Operating Instruction

  1. You can download the current version of the operating manual and the EU declaration of conformity via the following link:

https://hub.trotec.com/?id=43926

Technical information

Parameter Value
Model BX50 MID
Weight (packaging excluded) approx. 155 g

Dimensions

(length x width x height)

| approx. 119 x 68 x 77 mm (with plug)
Display| LCD with background illumination
Power supply|  |
230 V AC,  single-phase, 50/60 Hz
Power consumption| 10 VA
Power loss| < 2 W
Measuring range| 0.25 to 5 (16) A
Basic current (lb)| 5 A
Starting current| 0.004 lb
Accuracy class| 1/
Protection class| II/
Indicator resolution| 0 to 999999.9 kWh

0 to 999999.9 W

Operating conditions| -25 °C to 55 °C

0 % RH to 95 % RH (non-condensing)

Storage conditions| -40 °C to 70 °C,

0 % RH to 95 % RH (non-condensing)

Measuring category| CAT II
Pulse frequency (LED)| 1000 impulses/kWh
Type of protection| IP54
MID certification| yes

Disposal

Always dispose of packing materials in an environmentally friendly manner and under the applicable local disposal regulations.

The icon with the crossed-out waste bin on waste electrical or electronic equipment is taken from Directive 2012/19/EU. It states that this device must not be disposed of with household waste at the end of its life. You will find collection points for free return of waste electrical and electronic equipment in your vicinity. The addresses can be obtained from your municipality or local administration. You can also find out about other return options that apply to many EU countries on the website https://hub.trotec.com/?id=45090. Otherwise, please contact an official recycling center for electronic and electrical equipment authorized for your country.

The separate collection of waste electrical and electronic equipment aims to enable the re-use, recycling, and other forms of recovery of waste equipment as well as to prevent negative effects on the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment.

Only for the United Kingdom
According to Waste Electrical and Electronic Equipment Regulations 2013 (SI 2013/3113) (as amended) devices that are no longer usable must be collected separately and disposed of in an environmentally friendly manner.

Overview of the MID measuring devices used

Use the following table to manage the MID devices used.

Declaration of conformity

The device has a factory calibration which replaces the initial calibration by a calibration authority. This is certified by a MID Declaration of Conformity according to EU Directive 2014/32/EU. The validity of this declaration expires 8 years after placing on the market. Afterward, the user of the measuring device is obliged to have the device recalibrated. The year of initial calibration is indicated on the device after the CE mark. Example:

  • M24: The device was manufactured and first calibrated in 2024. If the device is also placed on the market in 2024, the calibration validity ends at the end of 2032. If the device is not placed on the market until 2025, the calibration validity ends at the end of 2033.
  • 0598: Number of the accredited calibration laboratory. Here: SGS

The following page shows the original declaration of conformity certifying compliance with the relevant regulation.

Declaration of conformity
Per the European Measuring Instruments Directive 2014/32/EU, Annex II, Part 4

Herewith, we declare that the measuring device designated below complies with all provisions of the EU Measuring Instruments Directive as amended in 2014/32/EU.

Measuring device type Energy consumption measuring device
Machine no. / designation BX50 MID, BX50 MID F, BX50 MID C
Year of manufacture as of 05/2024
Notified body Notified body No. 0598: SGS Fimko Ltd.,

Takomotie 8, FI-00380 Helsinki, Finland

has examined by 2014/32/EU, Module B, and issued the following certificate: 0598/SGS0449 of 23/04/2020.

Relevant EU directives| Directive 2014/32/EU relating to the making available on the market of measuring instruments as amended on 26 February 2014
Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment as amended on 23 November 2012
Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU
Directive 2014/30/EU on electromagnetic compatibility as amended on 26 February 2014
Directive 2012/19/EU on waste electrical and electronic equipment
Applied harmonized| EN 50470-1:2006
Standards| EN 50470-3:2006
 | EN 61326-1:2013
 | EN 61000-3-2:2014
 | EN 61000-3-3:2013
Other standards and| EN 55011:2016+A1:2017
technical specifications applied| EN 61000-4-2:2009
 | EN 61000-4-3:2006+A1:2008+A2:2010
 | EN 61000-4-4:2012
 | EN 61000-4-5:2014+A1:2017
 | EN 61000-4-6:2014/AC:2015-06
 | EN 61000-4-11:2004+A1:2017
 | IEC 62321-2:2013
 | IEC 62321-3-1:2013
 | IEC 62321-4:2013
 | IEC 62321-5:2013
 | IEC 62321-6:2015
 | IEC 62321-7-1:2015
 | IEC 62321-7-2:2017
 | IEC 62321-8:2017
 | Regulation (EG) No. 1907/2006 (REACH)
Manufacturer and name of the authorized representative of the technical documentation| Trotec GmbH Grebbener Strasse 7 DE52525 Heinsberg

Place and date of issue:
Heinsberg, 2 April 2024

Joachim Ludwig, Managing Director

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals