natural high Ice Bath Water Chiller User Manual

August 7, 2024
natural high

natural high Ice Bath Water Chiller

IMPORTANT SAFEGUARDS

Basic safety precautions should always be observed when using an ice bath, including the following:

  1. Test the TEST button on the leakage switch before using the ice bath to ensure that the leakage protection is effective.
  2. Children should be supervised to ensure that they do not play with the chiller.
  3. Do not tilt the chiller more than 45 degrees, as this may cause the compressor to malfunction.
  4. Do not cover air inlet holes of the chiller when in use as this may cause compressor failure.
  5. Keep the fan at least 70 cm away from the wall to prevent hot air from being drawn back into the chiller, DO NOT put the chiller in a small enclosed space.
  6. Do not unplug the chiller when the ozone signal is still flashing on the screen.
  7. When the chiller is in heating mode, its normal to have condensation water leaking from the chiller.
  8. Put the chiller indoors or under a shelter if placed outside and protect from freezing during winter weather.
  9. When the ambient temp is below 32 degrees Fahrenheit, please drain the water inside the chiller to prevent freezing and further damage to the chiller.
  10. Turn off the chiller when it reaches the set temp and unplug the power supply before taking a bath.

APPLIANCE DESCRIPTION

  1. Carry Handles
  2. Led display screen
  3. Water hoses
  4. Water outlet
  5. Water inlet
  6. 6. Water filter 1
  7. Water filter 2
  8. Leakage switch
  9. Cooling fan
  10. Wheels

CONTROL PANEL DESCRIPTION

Button description:

  1. UP button

  2. DOWN button

  3. SET button

  4. 0N/OFF button

CONTROL PANEL BUTTON MANUAL:

  1. Temperature Set:
    Click the “SET” button until flashing, Click or press the “up” or “down” button to set target temp.

  2. WIFI set
    Switch on Bluetooth on your phone, connect to a 2.4GHz W!Fl network (not SGHz),Press and hold the”SET’ button on the chiller for 6 second until you hear a beep, the WIFI icon on the chiller should start flashing. Open the TUY A app on your device to connect with the chiller.

  3. Child lock:
    Press and hold the “UP” button and “DOWN” button together for 5 seconds to lock or unlock the control panel.

  4. Mode changes:
    Press and hold the “UP” button for 15 second to switch “cold only” or “dual t emp” modes if the chiller is designed to have both modes.

  5. “C” and “F” changes:
    Press and hold the ‘DOWN button for 10 second to exchange the temperature units between “C” and “F”,

WORKING AND STORAGE TEMP

Cooling mode working ambient temperature:
-5 ° C – 40 ° C (-41 “F – 104 ‘F) PS: if the ambient temp is A over 40 ° C, the chiller will still work, but with lower cooling efficiency.

Heating mode working ambient Temperature:
A -10 C C – 40 ° C ( -50 ‘F – 104 “F )

A Storage Temperature: 1 ° C – 50 C (33.8 “F – 122 “F )

A Storage Relative Humidity: 20%-85%

A IMPORTANT REMINDER:

When the chiller is not in use,
please remind customer to disconnect the inlet and outlet hoses and keep the chiller running without water till FL is shown on screen. This is to prevent:

  1. Scale deposit will settle inside the water pump and vacuum pump and cause clog.
  2. Water inside the chiller can freeze in winter time and cause damage to the chiller.

INCLUDED ACCESSORIES

  • Water hose

  • FiLter ELement*1

  • Wrench*1

  • Use Manual*1

  • Warning Label*1

  • Hair Catcher Filter*1

  • Rubber Sealing Rings

HOW TO INSTALL

  1. Take off the two plugs.

  2. Install the hair catching filter to the water inlet.

  3. Place the rubber sealing ring into the pipe joint.

  4. Connect the water pipe to the water inlet.

  5. Connect the other water pipe to the water outlet.

  6. Unpack the filter element.

  7. install the filter element into the filter bottle.

Step 1 : First connect the chiller INLET to the tub OUTLET, making sure the connection contains sealing gasket. (Torque 4KG)

Step 2: Connect the chiller OUTLET to the tub INLET, making sure the connection contains sealing gasket . (Torque 4KG)

Step 3: Add water to fill line on inside of tub and wait for water to cool to desired temp.

Step 4: Turn off the chiller and enjoy a safe bath.

APP CONNECTION

App setup

Ensure that your smartphone is connected only to a 2.4 GHz WiFi network and that Bluetooth is turned on. Make sure that your smartphone and the chiller are in the same area with WiFi coverage. The chiller is not programmed to work withs GHz WiFi networks.

  • Download the”TUYA SMART” app by searching for the app in the App Store or Google Play Store
  • Install the app on your smartphone and create an account (both are required).
  • If prompted, open the app in your browser to download it.
  1. Switch on Bluetooth on your iOS device.

  2. Connect to a 2.4GHz WiFi network(not 5 GHz)

  3. Press and hold the SET button on the chiller for 6 second until you hear a beep.

  4. The WiFI icon on the chiller should start flashing

Reference the following photos for iOS setup

  1. 0pen the TUYA app on your iOS device

  2. When the device pop-up appears,click the “Add”button.

  3. Click the “+”button.

  4. Enter your WiFi ID and password(  note: only use a 2 4GHz network) and click” Next”.

  5. Wait for the setup to complete.

  6. Click the “Done” button.

  7. Once the setup is complete, you should be able to control the chiller remotely using your smartphone from any location.

FAULT CODE AND SOLUTION

Error Code: FL,indicating the number 2 or 3 on the lower right corner of the screen.

Reason One:
Leakage of the chiller pipeline.
Solution :
Please check to make sure the unit was set up with the sealing rings on the connector(s) ofthe hose and if the water level is higher than water inlet.

Reason Two:
Self-priming pump failure.
Solution :
Please check to see if the self-priming pump is working. If There is no sound coming from pump, or the pump is not producing bubbles outflow of the water outlet, replace the self-priming pump.

Reason Three:
Water pump failure
Solution: Completely reset the Chiller unit.

ERRORCODE CAUSE SOLUTIONS
CH1 NTC1 failure Replace the NTC1 temp sensor, re-start the chiller
CH2 NTC2 failure Replace NTCNTC2 temp sensor
CH3 NTC3 failure Replace NTC3 temp sensor
CH4 NTC4 failure Replace NTC4 temp sensor

The position of the above sensor pairs on the motherboard is shown in the following figure:

WATER TEMPERATURE TROUBLESHOOTING

Cooling And Heating Malfunction

Reason One:
If neither the compressor or the fan works, please replace the main-board.

Reason Two:
If the compressor and fan are working, the fan exhaust temperature is higher than the ambient temperature (more than 5 degrees higher than the ambient temperature when cooling down, below the ambient temperature of more than 4 degrees when heating up ) , the machine runs normally
If the fan exhaust temperature is the same or slightly higher than the ambient temperature it indicates that the refrigerant of the machine is leaking.

Reason Three:
If the cooling efficiency is slower than before,please clean the dust on the condenser.

Reason Four:
If the compressor works but the fan does not work, the fan or main-board is faulty. (Contact Support)

Reason Five:
If the fan works but the compressor does not work, the compressor or the main- board may be faulty. (Contact Support)