AWILCO AW30010001 3000W Inverter Remote Control User Manual

August 5, 2024
AWILCO

AWILCO AW30010001 3000W Inverter Remote Control

AWILCO-AW30010001-3000W-Inverter-Remote-Control-
PRODUCT

Product Usage Instructions

  • Connect one end of the included RJ-type cable into the Remote Port on the side of your Inverter.
  • Connect the other end into the cable interface of the Remote.
  • The ON/OFF switch is used to turn on or turn off the inverter.
  • If the inverter is already turned on, Remote will be turned on automatically after connection.
  • If the inverter is originally closed, then after connection, long press the ON/OFF button to turn on the inverter and all the indicators light up for 3 seconds.
  • Press the ON/OFF button shortly and the remote enters sleep mode. In sleep mode, only the POWER LED lights up, and other LEDs go out.
  • Press the ECO button shortly to enter ECO mode and the ECO indicator lights up. The inverter will adjust its output based on the power consumption of connected appliances.
  • The ON LED indicates that the inverter has been turned on. The BATTERY LEDs show the approximate battery voltage.
  • The LOAD LEDs show the approximate power of connected appliances.
  • When the connected battery is charged by a solar panel, the SOLAR LED lights up and the BATTERY LEDs show the charging status.
  • When appliances are powered by mains supply, UPS LED lights up indicating the voltage status of the battery.

FAQ

  • Q: How do I know if my inverter is in ECO mode?
  • A: The ECO indicator will light up when the inverter is in ECO mode.
  • Q: What does it mean when the LOAD LEDs show the power of appliances?
  • A: The LOAD LEDs indicate the approximate power consumption of the electrical appliances connected to the inverter.

Please be sure to read and save the entire manual before using the product.
Misuse may result in damage to the unit and/or cause harm or serious injury.
PLEASE KEEP THE MANUAL FOR FUTURE REFERENCE

WARNING

Read all instructions before operating. Failure to follow all instructions may result in electric shock, fire, and/or serious injury.

  • AVOID DANGEROUS ENVIRONMENTS. Don’t use it in damp locations.
  • KEEP CHILDREN AWAY. Keep away from children. This is not a toy!
  • STORE INDOORS. When not in use, your remote should be stored indoors in dry, and high or locked-up places – out of reach of children.
  • DON’T ABUSE CORD. Never carry your remote by cord or yank the cord to disconnect it from the receptacle. Keep cord from heat, oil, and sharp edges.
  • DISCONNECT. Disconnect from the power supply when not in use.
  • PROPER COOLING is essential when operating. Do not place it near a vehicle’s heat vent or in direct sunlight.
  • USE OF ACCESSORIES AND ATTACHMENTS. The use of any accessory or attachment is not recommended by the Manufacturer.
  • STAY ALERT. Use common sense. Do not operate when you are tired.
  • CHECK FOR DAMAGED PARTS. Any part that is damaged should be properly repaired or replaced by an authorized service center.
  • DO NOT OPERATE near flammable liquids or in gaseous or explosive atmospheres. Motors in tools or appliances used with the inverter may spark, and the sparks might ignite fumes.

FUNCTION DESCRIPTION DRAWING

  1. ON/OFF Switch/ Sleep Switch
  2. Battery voltage status indicator
  3. LOAD status indicator/ Fault indicator
  4. ON/OFF switch of “ECO” mode
  5. Fault indicator
  6. ON/OFF status indicator of inverter
  7. “ECO” status indicator
  8. Solar input indicator
  9. UPS mode Indicator

AWILCO-AW30010001-3000W-Inverter-Remote-Control-FIG-1

INSTALLATION

Mount the Remote
There are two ways to mount the Remote.

If there is 86 type bottom box in the vehicle

  • Use a crowbar or screwdriver to separate the front plate of the Remote from its main body.
  • Align the mounting holes on the middle of the main body with the holes on the 86-type bottom box. Fix the main body with included screws.
  • Reattach the front plate to the main body.

If there is no 86-type bottom box in the vehicle

  • Use a crowbar or screwdriver to separate the front plate of the Remote from its main body.
  • Use the main body as a template to mark four screw holes with a pencil.
  • Pre-drill four screw holes on the mounting surface with a drill.
  • Align the mounting holes on the corners of the main body with the pre-drilled screw holes. Fix the main body with included screws.
  • Reattach the front plate to the main body.

AWILCO-AW30010001-3000W-Inverter-Remote-Control-FIG-2

Connection
Connect one end of the included RJ-type cable to the Remote Port on the side of your Inverter. Connect the other end to the cable interface of the Remote.

AWILCO-AW30010001-3000W-Inverter-Remote-Control-FIG-3

OPERATION

ON/OFF switch is used to turn on or turn off the inverter.
If the inverter is already turned on, the Remote will be turned on automatically after connection; If the inverter is originally closed, then after connection, long press the ON/OFF button to turn on the inverter and all the indicators light up for 3 seconds.

| After 3 seconds, the “ON” LED and “BATTERY” LEDs still light up. The “ON” LED indicates that the inverter has been turned on. The “BATTERY” LEDs show the approximate battery voltage of your connected battery.
---|---
| Press the ON/OFF button shortly and the remote enters sleep mode.

Sleep mode: Only the “POWER” LED lights up, and other LEDs go out.

| When electrical appliances are connected to the inverter, the “LOAD” LEDs show the approximate power of your appliances and the “BATTERY” LEDs show the approximate power of the connected battery.
| Press the “ECO” button shortly to enter ECO mode and the “ECO” indicator lights up.

When the inverter is in ECO mode and the power of connected appliances is under 50W, the inverter will stop output and wait for the next period of the pulse; and when the power of connected appliances becomes over 50W, the inverter will start to output automatically.

| When the connected battery is charged by a solar panel, the “SOLAR” LED lights up and the “BATTERY” LEDs show the charging status of the battery.
| When the connected electrical appliances are powered by the main supply, the “UPS” LED lights up and the “BATTERY” LED indicates the voltage status of the connected battery.

REFERENCE

Indicated input voltage range of “Battery” LEDs

  1. Input voltage range: 10.50~11.20V, the LEDs indicate 20%.
  2. Input voltage range: 11.20~11.85V, the LEDs indicate 40%.
  3. Input voltage range: 11.85~12.30V, the LEDs indicate 60%.
  4. Input voltage range: 12.30~12.80V, the LEDs indicate 80%.
  5. Input voltage range: above 12.30V, the LEDs indicate 100%.

Indicated electrical appliances power of “LOAD” LEDs

  1. Power of all the connected electrical appliances: <400W, the indicators don’t light up.
  2. Power of all the connected electrical appliances: 400~800W, the LEDs indicate 20%.
  3. Power of all the connected electrical appliances: 800~1200W, the LEDs indicate 40%.
  4. Power of all the connected electrical appliances: 1200~1600W, the LEDs indicate 60%.
  5. Power of all the connected electrical appliances: 1600~2000W, the LEDs indicate 80%.
  6. Power of all the connected electrical appliances: >2000W, the LEDs indicate 100%.

TROUBLESHOOTING

AWILCO-AW30010001-3000W-Inverter-Remote-Control-FIG-10

AWILCO-AW30010001-3000W-Inverter-Remote-Control-FIG-11 AWILCO-AW30010001-3000W-Inverter-Remote-Control-
FIG-12

SPECIFICATION

Model 30.01.0001
DC Input Voltage Range 7-18V
Working current 10mA
Shutdown current 8mA
Sleeping current 9mA
Supplied cable RJ12 interface for 1000W inverter, 5m,

RJ45 interface for 2000W inverter, 5m

Working Temperature Range| -20~50°C
Dimensions| 86 x 86 x 22.5mm
Weights| 70g
IP Rating| IP22

SERVICE CONTACT INFORMATION

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals