ELED LPV-150RF-12 RF Constant Voltage LED Driver Owner’s Manual

August 2, 2024
ELED

ELED LPV-150RF-12 RF Constant Voltage LED Driver

Product Information

Product Specifications:

  • Model: LPV-150RF-12, LPV-150RF-24
  • Type: RF Constant Voltage LED Driver
  • Dimming Interface: RF wireless, AC Push-dim
  • Input Voltage: Universal AC 110-277VAC
  • Output: 1 channel constant voltage, Max. 150W
  • Active PFC Function: 0.95 Typ
  • Protection: IP20
  • Compliance: IEC/EN standards, EN55015, EN61000-3-2 Class C, etc.

Product Usage Instructions

  • Wiring Diagram:
    Refer to the provided wiring diagram for proper installation.

  • Dimming Methods:

    • Short Press: Turn on or off the light.
    • Long Press (1-6s): Step-less dimming; every other long press changes the light level direction.
    • Dimming Memory: Light returns to the previous dimming level after power failure.
  • Synchronization:
    To synchronize multiple LED drivers connected to the same push switch, do a long press for more than 15s. Ensure not to exceed 25 LED drivers per push switch and keep wire length under 20 meters.

  • Light On/Off Fade Time:
    To set the light on/off time, follow the provided instructions for the long press and short press of the match key.

  • Match Remote Control:
    Choose between two match ways: Use Match Key or Use Power Restart. Follow the steps provided to match or delete remote controls accordingly.

Frequently Asked Questions

Q: How many remote controls can one RF LED driver accept?

A: One RF LED driver can accept up to 10 remote controls.

Q: What is the maximum total output power of the LED driver?

A: The LED driver has a maximum total output power of 150W.

Q: How to reset the light on/off time to factory default?

A: Long press the match key for 10s to restore factory default parameters.

Features

  • Dimming interface: RF Wireless, AC Push-dim
  • Match with RF 2.4G single color remote control, one RF LED driver accepts up to 10 remote controls
  • Universal AC input/110-277VAC
  • 1 channel constant voltage output, Max. total output power 150W
  • Built-in active PFC function: 0.95 Typ, THD<10%
  • Light on/off fade time 3s selectable
  • No load/Standby power<0.5W
  • Load / Over-heat / Short circuit protection
  • Suitable for indoor LED lighting application
  • 5 Year, 50,000hr warranty

Applications

  • Suitable for LED-related fixtures or appliances that use LED light bars and LED tape (like LED Decoration or Advertisement devices).
  • Office/Commercial/Domestic Lighting, Hotels, Retail and Display.
  • Use for retrofit upgrades & new luminaire designs.

Mechanical Structures and Installations

Technical Parameters

Model LPV-150RF-12 LPV-150RF-24

Output

| Output Voltage| 12VDC| 24VDC
Output Current| Max. 12.5A| Max. 6.25A
Output Power| Max. 150W ( Input: 200-277VAC) ; Max. 120W( Input: 110-200VAC)
Startup time| 1000mS/100VAC, 500mS/230VAC
Dimming Range| 0~100%
Ripple & Noise| 150mV| 240mV

Input

| Input Voltage Range| 110~277VAC (Please refer to “Static characteristic” section)
Frequency Range| 50/60Hz
Efficiency| 92%/230VAC
Alternating Current| 1.5A/110VAC, 0.75A/230VAC, 0.7A/277VAC
Power Factor| >0.95
THD| <10%/110VAC/230VAC, <15%/277VAC@ Full load
Inrush Current| Cold start 30A at 230VAC
Anti Surge| L-N:1KV
Leakage Current| <5mA
No Load/Standby Power| <1W

Protection

| Over Load| Output hiccups occur when the load is 110% to 140%, and recovery occurs automatically when the fault condition is removed.

Over Temperature| Current decrease when PCB temp>110, recovers automatically after fault condition is removed
Short Circuit| Shut down the output voltage, which recovers automatically after the fault condition is removed

Environment

| Woking Temperature| -20℃~50℃
T-case Max| 90℃
Working Humidity| 20~90%RH, non-condensing
Storage Temperature/Humidity| -40℃~80℃, 10%~95%RH
Temperature Coefficient| ±0.03%/℃ (0-50%)
Vibration Resistance| 10-500Hz, 2G, 6min/cycle, X, Y, Z axes/2min
IP Rating| IP20

Safety&EMC

| Security Specifications| IEC/EN61347-1, IEC/EN61347-2-13, GB19510.14
Withstand Voltage| I/P-O/P: 3750VAC
Insulation Resistance| I/P-O/P: 100MΩ/500VDC/25℃/70%RH
EMC Emission| EN55015, EN61000-3-2 Class C, IEC61000-3-3
EMC Immunity| EN61000-4-2.3.4.5.6.8.11, EN61547
Certifications| CE
Net weight| 420g ± 5%
Gross weight| 450g ± 5%

Wiring Diagram

  1. RF Connection
  2. AC Push-Dim connection

The provided AC Push-Dim interface allows for a simple dimming method using commercially available non-latching (momentary) wall switches.

  • Short press: Turn on or off the light.
  • Long press (1-6s): Press and hold to step-less dimming, with every other long press, the light level goes to the opposite direction.
  • Dimming memory: Light returns to the previous dimming level when switched off and on again, even at power failure.
  • Synchronization:
    • If more than one LED driver is connected to the same push switch, do a long press for more than 15s, then the system is synchronized and all lights in the group dim up to 100%.
    • This means there is no need for any additional synchrony wire in larger installations.
    • We recommend the number of LED drivers connected to a push switch does not exceed 25 pieces,
    • The maximum length of the wires from the push to the LED driver should be no more than 20 meters.

Light on/off fade time

  • Long press match key 5s, then short press match key 3 times, the light on/off time will be set to 3s, and the indicator light blink 3 times.
  • Long press match key 10s, restore factory default parameter, the light on/off time also restore to 0.5s.

Match Remote Control

Match Remote Control (two match ways)
The end user can choose the suitable match/delete ways. Two options are offered for selection:

Use Match key

  • Match:
    • Short press the match key, and immediately press the on/off key (single zone remote) or zone key (multiple zone remote) on the remote.
    • The LED indicator fast flashes a few times means the match is successful.
  • Delete:
    • Press and hold the match key for 5s to delete all matches,
    • The LED indicator fast flashes a few times means the match was deleted.

Use Power Restart

  • Match:
    • Switch off the power 5s, then switch on the power 2s, repeat.
    • Immediately short press the on/off key (single zone remote) or zone key (multiple zone remote) 3 times on the remote.
    • The light blinks 3 times means the match is successful.
  • Delete:
    • Switch off the power 5s, then switch on the power 2s, and repeat.
    • Immediately short press on/off key (single zone remote) or zone key (multiple zone remote) 5 times on the remote.
    • The light blinks 5 times means all matched remotes were deleted.

When using multiple RF drivers, two application methods:

  • Auto-transmitting:
    One driver can transmit the signals from the remote to another driver within 30m, as long as there is a driver within 30m, the remote control distance can be extended.

  • Auto-synchronization:

    • Multiple drivers within a 30m distance can work synchronously when they are controlled by the same remote.
    • Driver placement may offer up to 30m communication distance. Metals and other metal materials will reduce the range.
    • Strong signal sources such as WiFi routers and microwave ovens will affect the range.
    • We recommend for indoor applications that driver placements should be no further apart than 15 m.

Output Load VS Temperature

Static characteristic

Installation precautions

  1. This product must be installed and adjusted by a qualified professional.
  2. This product is non-waterproof. When installed outdoors, please ensure it is mounted in a waterproof enclosure.
  3. The ambient temperature in which the product is installed must not exceed the value of Ta at any time.
  4. LED drivers should keep a certain distance from the heating stuff(such as the luminaries radiator). The installation interval between the product and the product is recommended to be 20cm, so as not to affect the service life due to poor heat dissipation.
  5. The installation height shall be ≥ 1m from the floor to avoid shortening the remote control distance due to too weak a reception signal.
  6. The products are not allowed to be close to or covered by metal objects, with an interval of ≥ 20cm to avoid signal attenuation and shorten the remote control distance.
  7. Avoid installation at the corner of the wall or the corner of the beam, with an interval of ≥ 20cm to avoid signal interference.

Dimming Curve

Failure analysis and troubleshooting

Fault

| Cause|

Solution

---|---|---
The light can not be turned on| 1.  No power

2.  Wrong wiring

| 1.  Check the power supply

2.  Connection test

The brightness of the light is inconsistent| 1.  Output cable is too long

2. The wire diameter is too small

| 1.  Reduce wire length or loop power supply

2.  Replace Replace to thicker wires

Hiccup flashing light| Overload| Check the power of the LED light