Product Information

The Shelly Pro Dimmer 1PM is a smart dimmer designed for DIN-rail mounting. It comes with factory-installed firmware that can be updated for enhanced security and performance.

Specifications

  • Product Name: Shelly Pro Dimmer 1PM
  • Type: DIN-rail mountable, one-channel smart dimmer
  • Rated Current: Max. 10A
  • Wire Compatibility: Stranded and solid; bootlace ferrules

Installation Instructions

  1. To control the dimmer, connect the switches to terminals SW1 and SW2 and the live cable as shown in Fig. 1 a).
  2. If you want to dim with a single switch, connect the switch to terminal SW1 and the live cable as shown in Fig. 1 b).
  3. For simple on/off functionality, connect the switch to terminals SW1 and the live cable as shown in Fig. 1 c).

Product Usage Information

Follow these steps to use the Shelly Pro Dimmer 1PM:

  1. Ensure the device is properly installed according to the installation instructions.
  2. Connect the appropriate switches and cables based on your desired functionality (dimming or on/off).
  3. Access the device settings through the embedded web interface or the Shelly Smart Control mobile application for customization.
  4. Monitor the device’s performance and make any necessary adjustments for optimal usage.

FAQ

  • Q: How do I update the firmware of the Shelly Pro Dimmer 1PM?
    A: Firmware updates can be accessed through the embedded web interface or the Shelly Smart Control mobile application. It is the user’s responsibility to install updates promptly.

  • Q: What should I do if I encounter installation or operation issues?
    A: Check the knowledge base page at https://shelly.link/pro_dimmer_1PM for troubleshooting guidance. You can also refer to the user manual for assistance.

Safety information

For safe and proper use, read this guide, and any other documents accompanying this product. Keep them for future reference. Failure to follow the installation procedures can lead to malfunction, danger to health and life, violation of law, and/ or refusal of legal and commercial guarantees (if any). Shelly Europe Ltd. is not responsible for any loss or damage in case of incorrect installation or improper operation of this device due to failure to follow the user and safety instructions in this guide.

  • This sign indicates safety information
  • This sign indicates important note.
  • WARNING! Risk of electric shock. Installation of the Device to the power grid must be performed carefully by a qualified electrician.
  • WARNING! Before making any changes to the connections, ensure there is no voltage present at the Device terminals.
  • CAUTION! Plug in or unplug the LAN cable only when the Device is powered off. The parts of the LAN cable that may be touched when plugging in or unplugging it, must not be metallic.
  • CAUTION! Connect the Device only in the way shown in these instructions. Any other method could cause damage and/or injury.
  • CAUTION! Connect the Device only to a power grid and appliances that comply with all applicable regulations. A short circuit in the power grid or any appliance connected to the Device can cause fire, property damage, and electric shock.
  • CAUTION! The Device and the appliances connected to it, must be secured by a cable protection switch in accordance with EN60898-1 (tripping characteristic B or C, max. 10A rated current, min. 6 kA interrupting rating, energy limiting class 3).
  • CAUTION! Before installing the Device, turn the circuit breakers off. Use a suitable test device to make sure there is no voltage on the wires you want to connect. When you are sure that there is no voltage, proceed to the installation.
  • CAUTION! Do not use the Device if it shows any sign of damage or defect.
  • CAUTION! The Device may be connected to and control only electric circuits and appliances that comply with the applicable standards and safety norms.
  • CAUTION! Plug in or unplug the LAN cable only when the Device is powered off. The parts of the LAN cable that may be touched when plugging in or unplugging it, must not be metallic.
  • CAUTION! The Device is intended only for indoor use.
  • CAUTION! Keep the Device away from dirt and moisture.

Product description

Shelly Pro Dimmer 1PM (the Device) is a DIN-rail mountable, one-channel smart dimmer. The Device can be accessed, controlled, and monitored remotely from any place where the User has internet connectivity, as long as the device is connected to a Wi-Fi router and the Internet.

The Device has an embedded web interface used to monitor, control, and adjust the Device. The web interface is accessible at http://192.168.33.1 when connected directly to the Device access point or at its IP address when you and the Device are connected to the same network.

The Device can access and interact with other smart devices or automation systems if they are in the same network infrastructure. Shelly Europe Ltd. provides APIs for the devices, their integration, and cloud control. For more information, visit https://shelly-api-docs.shelly.cloud.

The Device comes with factory-installed firmware. To keep it updated and secure, Shelly Europe Ltd. provides the latest firmware updates free of charge. Access the updates through either the embedded web interface or the Shelly Smart Control mobile application. Installation of firmware updates is the user’s responsibility. Shelly Europe Ltd. shall not be liable for any lack of conformity of the Device caused by the failure of the user to install the available updates in a timely manner.

Installation instructions

  • To connect the Device, we recommend using solid single-core wires or stranded wires with ferrules. The wires should have insulation with increased heat resistance, not less than PVC T105°C (221°F).
  • When connecting wires to the Device terminals, consider the specified conductor cross-section and stripped length. Do not connect multiple wires into a single terminal.
  • For security reasons, after you successfully connect the Device to the local Wi-Fi network, we recommend that you disable or password-protect the Device AP (Access Point).
  • To perform a factory reset of the Device, press and hold the Control button for 10 seconds.
  • To enable the access point and the Bluetooth connection of the Device, press and hold the Control button for 5 seconds.
  • Connect he load to the O terminal of the Device and the Neutral wire as shown in the wiring diagram.
  • Connect the Live wire to the L terminal.
  • If you want to control the dimming with two buttons, connect buttons to the SW1 and SW2 terminals, and to the Live wire as shown in Fig. 1 a).
  • If you want to control the dimming with a single button, connect the button to the SW1 terminal and to the Live wire as shown in Fig. 1 b).
  • If you want to just turn the lights on or off, connect the switch to the SW1 terminals and the Live wire as shown in Fig. 1 c).

Wiring diagram

Ver1-Shelly-Pro-Dimmer-1

Legend

  • Device terminals
    • SW1, SW2: Switch input terminals controlling O
    • O: Load circuit output terminal
    • L: Live (110-240 V) terminals
    • N: Neutral terminal
    • LAN: Local Area Network RJ 45 connector
  • Wires
    • L: Live (110-240 V) wire
    • N: Neutral wire

Specifications

  • Size (HxWxD): 94x19x69 mm / 3.70×0.75×2.71 in

  • Weight: 75 g / 2.7 oz

  • Screw terminals max torque: 0.4 Nm / 3.5 lbin

  • Conductor cross-section:

    • 0.5 to 2.5 mm² / 20 to 14 AWG (green connectors)
    • 0.5 to 1.5 mm² / 20 to 16 AWG (blue connector) (solid, stranded, and bootlace ferrules)
  • Conductor stripped length:

    • 6 to 7 mm / 0.24 to 0.28 in (green connectors)
      5 to 6 mm / 0.20 to 0.24 in (blue connector)
  • Mounting: DIN-rail

  • Shell material: Plastic

  • Shell color: Lime

  • Ambient working temperature: -20°C to 40°C / -5°F to 105°F

  • Humidity: 30% to 70% RH

  • Max. altitude: 2000 m / 6562 ft

  • Power supply: 110 – 240 VAC ~ 50/60 Hz

  • Power consumption: < 2 W

  • External protection: Max. 10 A, tripping characteristic B or C, 6 kA interrupting rating, energy limiting class 3

  • Max. output power: 200 W

  • Dimming type: Trailing edge

  • Voltmeter (AC): Yes

  • Ammeter (AC): Yes

  • Power and energy meters: Yes

  • Internal-temperature sensor: Yes

  • Supported loads:

    • Incandescent
    • Dimmable LED
    • Dimmable electronic transformers
    • Iron-core transformers with low-voltage incandescent lamps
  • Wi-Fi

    • Protocol: 802.11 b/g/n
    • RF band: 2400-2483 MHz
    • Max. RF power: < 20 dBm
    • Range: Up to 30 m / 100 ft indoors and up to 50 m / 160 ft outdoors (depending on local conditions)
  • Bluetooth

    • Protocol: 4.2
    • RF band: 2400-2483.5 MHz
    • Max. RF power: < 4 dBm
    • Range: Up to 30 m / 100 ft outdoors, up to 10 m / 33 ft indoors (depending on local conditions)
  • CPU: ESP32-D0WDQ6

  • Flash: 8MB

  • Schedules: 20

  • Webhooks (URL actions): 20 with 5 URLs per hook

  • Scripting: Yes

  • MQTT: Yes

Shelly Cloud inclusion

  • The Device can be monitored, controlled, and set up through our Shelly Cloud home automation service. You can use the service through either our Android, iOS, or Harmony OS mobile application or through any internet browser at https://control.shelly.cloud/.
  • If you choose to use the Device with the application and Shelly Cloud service, you can find instructions on how to connect the Device to the Cloud and control it from the Shelly app in the application guide: https://shelly.link/app-guide.
  • The Shelly mobile application and Shelly Cloud service are not conditions for the Device to function properly. This Device can be used standalone or with various other home automation platforms.

Troubleshooting

In case you encounter problems with the installation or operation of the Device, check its knowledge base page: https://shelly.link/pro_dimmer_1PM

Declaration of Conformity
Hereby, Shelly Europe Ltd. declares that the radio equipment type Shelly Pro Dimmer 1PM is in compliance with Directive 2014/53/EU, 2014/35/EU, 2014/30/EU, 2011/65/EU. The full text of the EU declaration of conformity is available at the following internet address:
https://shelly.link/pro_dimmer_1PM_DoC
Manufacturer: Shelly Europe Ltd.
Address: 103 Cherni vrah Blvd., 1407 Sofia, Bulgaria
Tel.: +359 2 988 7435
E-mail: support@shelly.cloud
Official website: https://www.shelly.com
Changes in contact information are published by the Manufacturer on the official website.

All rights to the trademark Shelly® and other intellectual rights associated with this Device belong to Shelly Europe Ltd.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Shelly User Manuals

Related Manuals