getic UBB UniFi Building Bridge User Guide

July 27, 2024
Getic

getic UBB UniFi Building Bridge

Specifications

  • Package Contents:
    • UBB (Qty. 2)
    • Ball Joint Mount (Qty. 2)
    • Lock Ring (Qty. 2)
    • Metal Strap (Qty. 2)
    • Gigabit PoE (48V, 0.32A) with Mounting Bracket (Qty. 2)
    • Power Cord (Qty. 2)
  • System Requirements:
    • UniFi Cloud Key (1.0.5 or newer) or UniFi Dream Machine (1.0.1 or newer)
    • Linux, Mac OS X, or Microsoft Windows 7/8/10
    • Java Runtime Environment 1.6 (1.8 or newer recommended)
    • UniFi Controller software v5.12.x (or newer), available at: ui.com/download/unifi
    • UniFi Network App (iOS or AndroidTM) or Web Browser (Google Chrome preferred)

Product Usage Instructions

  • Pole-mounting: You will need an 8 mm socket wrench or screwdriver for this type of mounting.
  • Wall-mounting: Requires a wall fastener (not included).
  • The device requires a clear line of sight to the sky for proper GPS operation.
  • Use shielded Category 5 (or above) cabling with a drain wire for all wired Ethernet connections and ground it through the AC ground of the PoE.
  • System LED: Indicates different states such as initializing, factory defaults, busy, and successful integration.
  • Flashing Reset Button: Used to locate a device and reset it to factory defaults.
  • Ethernet Port: Local UBB radio connects to LAN and DHCP server, while Remote UBB radio connects to LAN and receives IP address via wireless link.

Note: Center screw included. Two optional screws (not included) provide additional stability.

FAQ

  • Q: How do I reset both UBB radios to re-establish the link if a link is lost due to configuration changes?
  • A: Press and hold the Reset button for about 10 seconds until the LED starts flashing and then becomes solidly lit. After a few seconds, the LED will turn off, and the device will automatically reboot.

Package Contents

System Requirements

  • One of the following:
  • UniFi Cloud Key (1.0.5 or newer) or UniFi Dream Machine (1.0.1 or newer)
  • Linux, Mac OS X, or Microsoft Windows 7/8/10
  • Java Runtime Environment 1.6 (1.8 or newer recommended)
  • UniFi Controller software v5.12.x (or newer), available at:
  • ui.com/download/unifi
  • UniFi Network App (iOS or Android™) or Web Browser (Google Chrome preferred)

Installation Requirements

  • Pole-mounting: 8 mm socket wrench or screwdriver
  • Wall-mounting: wall fastener (not included)
  • The device needs to have clear line of sight to the sky for proper GPS operation.
  • Shielded Category 5 (or above) cabling with drain wire should be used for all wired Ethernet connections and should be grounded through the AC ground of the PoE.
  • We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial-grade, shielded Ethernet cable from Surge protection should be used for all outdoor installations.
  • We recommend that you use two Ethernet Surge Protectors, model ETH-SP-G2, one near the device and the other at the entry point to the building. The ETH-SP-G2 will absorb power surges and safely discharge them into the ground.

Hardware Overview

   System LED

Flashing White

|

Initializing.

White

|

Factory defaults, waiting for integration.

Alternating White/Blue

|

The device is busy; do not touch or unplug it. This usually indicates that a process such as a firmware upgrade is taking place.

Blue

|

Successfully integrated into a network and working properly.

Flashing

|

This is used to locate a device.

When you click Locate in the UniFi Network Controller software, the LED will flash blue. The software will also display the location of the device on the map.

   Reset Button

Resets to factory defaults. The device should be running after the bootup is complete. Press and hold the Reset button for about 10 seconds until the LED starts flashing and then becomes solidly lit. After a few seconds, the LED will turn off, and the device will automatically reboot.

Note: The UBB radios are pre-paired. If a link is lost due to configuration changes, you can reset both UBB radios to re-establish the link.

   Ethernet Port

Local UBB radio (source LAN) This Gigabit Ethernet port is used to connect the power and should be connected to the LAN and DHCP server.

Remote UBB radio (bridged LAN) This Gigabit Ethernet port is used to connect the power and should be connected to the LAN. It will receive its IP address from the

For each UBB radio, go to the appropriate mounting instructions: Pole Mounting or “Wall Mounting”.

Pole-Mounting

Wall Mounting

  • The device must be mounted directly to a wood stud or other structurally stable surface to avoid damage to the mounting hole when you adjust the aim.

Optional Accessory

  • To enhance stability, you can use the NanoBeam® Wall Mount Kit, model NBE-WMK (sold separately).

Note: Center screw included. Two optional screws (not included) provide additional stability.

Installation Instructions

Aiming
Visually aim the UBB radios at each other:

Connecting Power

  • For each UBB radio:

WARNING: The switch port must comply with the power specifications listed in the Specifications section of this Quick Start Guide.

Optional

Adopting the UBB
The UBB radios are pre-paired. For each UBB radio, you have the following options:

  • “Using the UniFi Network App”
  • “Using the UniFi Network Software

Note: If a link is lost due to configuration changes, you can reset both UBB radios to re-establish the link.

Using the UniFi Network App

  • The System LED will turn blue to confirm that it has been successfully adopted.

Using the UniFi Network Software

  1. From the UniFi Network Controller dashboard, click Devices in the left menu bar.
  2. On the Devices screen, locate the UBB in the list of devices under the Model column. To adopt the UBB, click Adopt.
  3. The System LED will turn blue to confirm that it has been successfully adopted.

Specifications

UBB

Dimensions| 140 x 140 x 90 mm (5.51 x 5.51 x 3.54″)
Weight| 376 g (13.3 oz)
Antenna Gain

2.4 GHz (BLE) 5 GHz

60 GHz

| 2 dBi

10 dBi

17.2 dBi

GPS| Yes
Networking Interface| 10/100/1000 Ethernet Ports Bluetooth for Management
Enclosure| UV-Resistant Polycarbonate
Power Method| 802.3af Supported Passive Power over Ethernet (48V)
Power Supply| UniFi PoE Switch 48V, 0.32A Gigabit PoE Adapter (Included)
Max. Power Consumption| 11W
Wind Loading| 56 N @ 200 km/h (12.6 lbf @ 125 mph)
Wind Survivability| 200 km/h (125 mph)
Mounting| Pole-Mount (Kit Included) Wall-Mount (Not Included)
ESD/EMP Protection| ± 24kV Contact/Air
Operating Temperature| -40 to 60° C (-40 to 140° F)
Operating Humidity| 5 to 95% Noncondensing
Operating Frequency (MHz)

Worldwide| 5150 – 5875

57,000 – 66,000

US/CA| U-NII-1:| 5150 – 5250
U-NII-2A| 5250 – 5350
U-NII-2C| 5470 – 5725
U-NII-3:| 5725 – 5850
57,000 – 67,000

Safety Notices

  1. Read, follow, and keep these instructions.
  2. Heed all warnings.
  3. Only use attachments/accessories specified by the manufacturer.

WARNING: Do not use this product in a location that can be submerged by water.
WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.

Electrical Safety Information

  1. Compliance is required to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed.
  2. There are no operator-serviceable parts inside this equipment. Service should be provided only by a qualified service technician.
  3. This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.
    • Do not substitute the power cord with one that is not the approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
    • The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.
    • Contact a qualified electrician or the manufacturer if there are questions about the installation before connecting the equipment.
    • Protective earthing is provided by a Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.

Limited Warranty

  • ui.com/support/warranty
  • The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where applicable, specify arbitration instead of jury trials or class actions.

FCC STATEMENT

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, according to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used under the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This radio transmitter has been approved by the FCC.

ISED Canada
CAN ICES-3(A)/NMB-3(A)
This device complies with ISED Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:

  1. This device may not cause interference, and
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

This radio transmitter has been approved by ISED Canada.
The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems.

IMPORTANT NOTE
Radiation Exposure Statement
This equipment complies with radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Australia and New Zealand
Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment, this equipment may cause radio interference.

CE Marking
CE marking on this product represents the product complies with all directives that apply to it.

The following apply to products that operate in the 5 GHz frequency range:

  • Note: This device is restricted to indoor use only when operating in the 5150 – 5350 MHz frequency range within all member states.
  • Note: All countries listed may operate at 30 dBm. BFWA member states may operate at 36 dBm.
  • Note: Operation in the 5.8 GHz frequency band is prohibited in BFWA member states.
  • Other countries listed may use the 5.8 GHz frequency band.
  • Note: Fixed service or any restrictions for authorization of use shall follow local country regulations.

WEEE Compliance Statement

Online Resources

Documents / Resources

| getic UBB UniFi Building Bridge [pdf] User Guide
UBB UniFi Building Bridge, UBB, UniFi Building Bridge, Building Bridge, Bridge
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals