REJUVA FRESH EMSLIM Body Sculpting Machine User Manual

July 25, 2024
REJUVA FRESH

REJUVA FRESH EMSLIM Body Sculpting Machine

Product Usage Instructions

  • Before use:

    • Use at least one hour after meals.
    • DO NOT use when feeling full after eating.
    • Before starting the treatment, remove any metal jewelry you are wearing.
    • DO NOT operate on the head, neck/carotid artery, or near the thoracic gallery.
    • The area to be treated and the handles must be dry.

PREFACE

  • Thank you for choosing the REJUVA FRESH EMSLIM Body Sculpting Machine.
  • Small in size, yet powerful in effect, Rejuva Fresh Home Use EMSlim Neo destroys fat cells while at the same time building muscle fibers, allowing you to enjoy a well-defined abdominal area, and overall improved body contour. All this, without any additional diet or exercise! Moreover, it’s perfectly portable, so you can enjoy the treatment anywhere.
  • The use of this machine is a safe, minimally invasive procedure, and easy to operate.
  • There are no bleeding, no pain, and no side effects.
  • Please read this User Manual carefully to use the machine properly and to protect the machine from unnecessary damage.
  • Should you encounter any issues during the operation of the machine or any related questions, you can contact us at our website: rejuvafresh.com or email us at hello@rejuvafresh.com.

PRODUCT INFORMATION & SPECIFICATION

Product Information

  • The machine simultaneously emits synchronized high-intensity electromagnetic energy and radio frequency (RF).
  • The RF heat prepares muscles for exposure to stress, similar to what a warm-up activity does before any physical workout.
  • Within minutes, fat cells are collapsed & damaged and are slowly removed from the body.
  • The energy passes through the skin and fat tissues and stimulates the various layers of muscle, causing them to contract.
  • The range of frequencies used is such that the muscles are not allowed to relax in between contractions and are forced to remain contracted for several seconds.
  • Thus the muscles are strengthened and trained without any stress on the joints.

Product Specification

Power 1500 W
Voltage 100 V/ 110 V/ 220 V Voltage selected according to your region
Screen Size 7 in
Package Dimension 45 x 35 x 30 cm

List of Accessories

NOTE: for those who opt for “No RF”, the RF controller will not be present and the energy used for the procedure will be exclusively magnetic wave energy.

PRODUCT APPEARANCE

Front/Side view

WARNINGS

Before use

  • Use at least one hour after meals. DO NOT use when feeling full after eating
  • Before starting the treatment, remove any metal jewelry you are wearing.
  • DO NOT operate on the head, neck/carotid artery, or near the thoracic gallery.
  • The area to be treated and the handles must be dry before starting the treatment.
  • DO NOT eat during treatment. Try to eat or drink at least 1 hour after the treatment.
  • DO NOT put/use any electronic products or metal objects on the machine during treatment.
  • DO NOT drink water during treatment.
  • DO NOT USE if with heart disease, hypertension, thyroid, malignant tumor, renal failure, epilepsy, and muscle strain
  • DO NOT use if with metal or electronic implants (metal contraceptive ring, cardiac pacemaker, cardiac defibrillator, nerve stimulator, drug pump, and stent)
  • DO NOT use if pregnant, menstruating, conceiving, or breastfeeding
  • DO NOT use if had undergone major surgery, are Diabetic, and with cerebrovascular disease ( stroke patients )

OPERATING POSITION

The position of the handle must be the same as the image below:

MODE SELECTION & OPERATION

  1. Function and Mode Selection
  2. After turning on the machine, the mode selection interface will appear
  3. There are two modes: AUTO and MANUAL mode. Select which mode to use.
  4. After choosing the mode, select the appropriate settings according to gender, age range, and target treatment area.
  5. Click the icon shown below to start working.

AUTO Mode

  1. Select the type of treatment. This is located at the bottom of the interface:
    • 【M1】:Basic training for beginners
    • 【M2】:Adaptation training.
    • 【M3】:Preliminary training
    • 【M4】:Advanced training
    • 【M5】:Professional training
    • NOTE: Each mode contains 6 different frequencies that automatically switch. The first minute of each mode is warm-up.
  2. The recommended intensity starts from 8% (weak) to 100% (strong).
    • 【Intensity】: Strength intensity,click【-】and【+】to adjust.
    • NOTE: Set the intensity before the start of treatment.
    • We recommend choosing the intensity lower which should be gradually increased according to the patient’s ability to withstand it.
  3. Set the working time. The default working time of one treatment is 30 minutes. This can be adjusted from 1 minute to 30 minutes.
  4. Click“ ” start. If need to pause, please click“ ”. Click“ ” return to the previous interface.
  5. Note: Click【-】and【+】to adjust parameters when the device is in a paused state.

MANUAL Mode

MANUAL Mode

  1. Manually adjust the frequency on the interface same as in the image above.
    • 【F1】:Frequency 1, the intensity range is 3HZ (weak) to 300Hz(strong);
    • 【F2】:Frequency 2, the intensity range is 3HZ (weak) to 300Hz(strong);
    • 【F3】: Frequency 3, the intensity range is 3HZ (weak) to 300Hz(strong).
    • NOTE: Before the start of treatment, set the frequency parameters according to the required frequency. F1 frequency works for 5 minutes, F2 frequency works for 1 minute, F3 frequency works for 5 minutes, and F1, F2, and F3 frequencies are cycled in sequence.
  2. The recommended intensity is from 8% (weak) to 100% (strong).
    • 【Intensity】:Strength intensity,click【-】and【+】to adjust.
    • NOTE: Set the intensity before the start of treatment. We recommend choosing the intensity lower which should be gradually increased according to the patient’s ability to withstand it.
  3. Set the working time. The default working time of one treatment is 30 minutes. This can be adjusted from 1 minute to 30 minutes.
  4. Click“ ”start. If need to pause, please click“ ”. Click“ ”return to the previous interface.
  5. Note: Click【-】and【+】to adjust parameters when the device is in a paused state.

FAQs

Who is suitable to use this machine?

The use of this machine can provide beneficial muscle tightening for most people especially for: Women who need to gain muscle and change their shape. Men need to gain muscle and change their bodies. People who need to lose weight-suitable for both men and women, more suitable for busy office workers. Those people who need to lose weight quickly are brides, models, actors, etc. Postpartum mother(experiencing separation of rectus abdominis. Improve the shape of the abdominal muscles and shape a flat abdomen

Is there a difference in the effect of abdominal treatment when one or two treatment heads are used? How should we choose?

It is recommended that all patients use the two treatment heads at the same time. Both treatment heads must be in full contact with the skin, and not hover sideways or extend beyond the treatment area. This will ensure that all abdominal muscles are treated and activated. Both therapies are equally effective.

Will it melt fat while lifting the hips?

Many studies have confirmed that the metabolic activity of buttock fat is lower than that of abdominal fat. Because of this, it will not dissolve fat when treating buttocks

Is this treatment safe? Will it affect the internal organs?

The only tissue that responds to energy is motor neurons, so it does not affect other tissues including organs.

Can it be combined with other body care treatments?

It can be combined with some non-traumatic fat removing care, such as various fat-reducing equipment, to eliminate more fat. In addition, it can be combined with some postpartum repair care to improve the health and physical problems of postpartum women.

MAINTENANCE

  1. Ensure that the power supply is stable. If the local power supply voltage is unstable, it is recommended that the user add a regulated power supply with matching power.
  2. The power cord of the socket is required to be more than 2. 1.5 square meters.
  3. When using this device, please keep away from the wall and keep a space of 30cm around the device for heat dissipation
  4. After each treatment, clean with a mild disinfectant.
  5. Please do not use alcohol or corrosive solvents to clean the host and handle to avoid damage.
  6. During treatment, avoid the damage caused by pressing the handle line and bending the handle line.
  7. DO NOT place the instrument in an environment with high temperature, humidity, dust, and direct sunlight. The instrument should be placed in a dry, cool, and ventilated room with a temperature of 5 to 40°C and a humidity of no more than 80%.

CONTACT

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>