REJUVA FRESH 9500W EMShape Neo Plus Body Sculpt Machine User Manual

June 1, 2024
REJUVA FRESH

REJUVA-FRESH-logo

REJUVA FRESH 9500W EMShape Neo Plus Body Sculpt Machine

REJUVA-FRESH-9500W-EMShape-Neo-Plus-Body-Sculpt-Machine-
product

Product Information

Specifications

  • Maximum Power Output: 9500 W
  • Input Voltage: 100 V/110 V/220 V (Voltage selected according to your region)
  • Technology: HIEMT and synchronized RF
  • Frequency of vibration: E
  • Frequency of RF: REJ
  • Max RF temperature: VA
  • Machine Size: 60 x 46 x 100 cm
  • Machine Weight: 79 kg

Product Usage Instructions

  1. Mode Selection & Operation
    Ensure you understand the different modes available:

    • a. Mode Selection
    • b. AUTO Mode
    • c. MANUAL Mode
    • d. Pelvic Floor Cushion
  2. Treatment Levels in AUTO Mode
    Understand the various treatment levels available in AUTO Mode for optimal results.

  3. Troubleshooting Solutions
    Refer to the manual for troubleshooting common issues that may arise during operation.

  4. Maintenance
    Follow the maintenance guidelines provided to ensure the longevity and efficiency of the machine.

FAQ

  • Q: How do I adjust the RF temperature for a comfortable treatment?
    A: Start with a low setting for RF and increase gradually to ensure comfort and effectiveness.

  • Q: What should I do if I encounter issues during the operation?
    A: Refer to the troubleshooting section in the manual or contact us at rejuvafresh.com for assistance.

PREFACE

  • Thank you for choosing REJUVA FRESH EMShape Neo Plus Body Sculpt Machine 9500W.
  • EMShape Neo Plus is engineered to perform body sculpting more effectively than any alternative equipment available in the global beauty marketplace.
  • The machine’s sleek design and high-end specifications guarantee maximum efficiency and fast, impressive benefits. Let your spa’s clientele indulge in a spa treatment that offers premium results.
  • Harness the power of the latest HIEMT technology and synchronized RF to deliver efficient and effective muscle-building and fat-reduction results. The procedure is 100%non-invasive, safe, and painless, with no downtime.
  • Please read this User Manual carefully to use the machine properly and to protect the machine from unnecessary damage.
  • Should you encounter any issues during the operation of the machine or any related questions, you can contact us at our website: rejuvafresh.com or email us at [email protected].
  • Thank you again, and please enjoy your REJUVA FRESH body sculpting equipment!

PRODUCT INFORMATION & SPECIFICATION

Product Information
This machine uses the latest HIEMT technology + synchronized RF to deliver efficient & effective muscle building + fat reduction. This process triggers the production of new collagen chains, thereby increasing muscle support and volume.

HIEMT (high-intensity electromagnetic technology) uses strong focused electromagnetic waves to stimulate and train the targeted muscle tissue. During a 30-minute treatment session, focused magnetic waves penetrate up to 8cm of muscle tissue, forcing the muscles to contract involuntarily many thousands of times. Such supra-maximal contractions are not achievable by normal exercise. The body naturally responds to this supra-maximal exercise by rebuilding muscle tissue, making the body more toned and stronger. As with normal exercise, there is a large amount of natural fat decomposition, resulting in body slimming.

Product Specification

Maximum Power Output 9500 W
Input Voltage 100 V / 110 V/ 220 V

Voltage selected according to your region

Technology| HIEMT + RF
Frequency of vibration| 1-300Hz
Frequency of RF| 40Mhz
Max RF temperature| 44 °C
Machine Size| 60X46X100 cm
Machine Weight| 79 kg

Warning!
RF can become hot. To make the treatment most comfortable and effective, we strongly suggest that you please start with a low setting for RF and increase it gradually.

List of Accessories

REJUVA-FRESH-9500W-EMShape-Neo-Plus-Body-Sculpt-Machine-
fig-1

PRODUCT APPEARANCE

  1. Front view
  2. Back view
  3. Side view
  4. Accessories

SAFETY WARNINGS

Please follow these precautions before/during/after use

  • Use at least one hour after meals. DO NOT use when feeling full after eating.
  • Before using the instrument, remove any metal jewelry you are wearing. DO NOT touch metal objects during the treatment.
  • Before starting the operation, touch the probe vertically to the skin, then turn on the switch of the main unit and adjust the intensity of the operation mode
  • Start with the lowest level, and then increase the intensity sequentially according to the user’s skin tolerance;
  • DO NOT eat during machine operation Try to eat some protein after one hour of session
  • DO NOT use if there are open wounds or any skin infections such as eczema or dermatology issues
  • DO NOT use if there are heart conditions (such arrhythmias) especially those with pacemakers
  • DO NOT use if diagnosed with cancer
  • DO NOT use if diagnosed with an infectious disease
  • DO NOT use if pregnant, menstruating, conceiving, or breastfeeding
  • DO NOT use if you have undergone major surgery, are Diabetic, and with cerebrovascular disease ( stroke patients ) must avoid
  • DO NOT use if have metal on any part of the body

TREATMENT POSITION

The position of the handles during treatment must be the same as below image for every area of the body:

REJUVA-FRESH-9500W-EMShape-Neo-Plus-Body-Sculpt-Machine-
fig-18

NOTES:

  1. Be careful to avoid positions of ribs and bones
  2. When operating the abdomen, select one or two handles according to the size of the customer’s abdomen.
  3. It is recommended to treat one part for 30 minutes.
  4. Before the operation, the metal objects worn on the body must be removed, and metal objects on the clothes must also be avoided.
  5. Before operation, fasten the bandage, insert the handle into the bandage fix it, and pay attention to the close position of the working head.
  6. Adjust the energy intensity before starting the operation. The treatment starts from low intensity and gradually improves, and slowly improves according to the comfort of customers.
  7. Note: if the customer doesn’t feel anything during the operation, the energy intensity can be appropriately strengthened, and the degree of strengthening can be asked whether the customer accepts it.

MODE SELECTION & OPERATION

Mode Selection

Function and Mode Selection

  1. On the interface, select the type of treatment to be used on the function selection interface.
  2. There are two General Mode Categories: AUTO and MANUAL mode. Select which one to use. (Figure 1)
  3. On setting the information interface, select the appropriate settings according to gender, age range, and fat thickness. (Figure 2)REJUVA-FRESH-9500W-EMShape-Neo-Plus-Body-Sculpt-Machine-fig-19
AUTO Mode

REJUVA-FRESH-9500W-EMShape-Neo-Plus-Body-Sculpt-Machine-
fig-20

AUTO MODE

  1. When using AUTO mode, there is a choice of TREATMENT LEVELS. Select a TREATMENT LEVEL according to the patient’s condition. When in doubt start with M1 to be conservative.
  2. The handle strengths A and B can be adjusted ranging from 8% (weak) to 100% (strong). Set the handle strength before the start of treatment. The treatment starts from low intensity and should be gradually increased according to the patient’s tolerance.
    • A B: Handle intensity of A and B, click【-】and【+】to adjust intensity.
    • C D: Handle intensity of C and D, click【-】and【+】to adjust intensity.
    • AB-RF: RF intensity of AB handle click – and + to adjust intensity.
    • CD-RF: RF intensity of CD handle, click【【-】】and【【+】】to adjust intensity.
  3. Set the working time. The default working time of one treatment is 30 minutes. This can be adjusted from 5 minutes to 60 minutes.
  4. Click the Start button to start the treatment. Click the Pause button if you need to pause the treatment.

NOTE: Adjust the settings when the device is in Pause mode.

Manual Mode

REJUVA-FRESH-9500W-EMShape-Neo-Plus-Body-Sculpt-Machine-
fig-21

MANUAL MODE

  1. On the interface, select Manual mode.
  2. On setting the information interface (Figure 2), select the appropriate settings according to gender, age range, and fat thickness.
  3. Adjust the frequency. Please see the next page for resetting setting.
  4. Set the frequency, adjustment settings are below:
    • F1: Frequency 1, the intensity range is 3HZ (weak) to 200Hz (strong)
    • F2: Frequency 2, the intensity range is 3HZ (weak) to 200Hz (strong)
    • F3: Frequency 3, the intensity range is 3HZ (weak) to 200Hz (strong)
    • NOTE: It’s recommended that F1 be set to 50HZ, F2 to 5HZ, and F3 to 150HZ, to achieve a balance of fat reduction and muscle building.REJUVA-FRESH-9500W-EMShape-Neo-Plus-Body-Sculpt-Machine-fig-22
  5. Before the start of treatment, set the frequency parameters according to the required frequency.
    • F1 frequency works for 5 minutes,
    • F2 frequency works for 1 minute,
    • F3 frequency works for 5 minutes, and * F1, F2, and F3 frequencies are cycled in sequence.
  6. The handle strengths A and B can be adjusted ranging from 8% (weak) to 100% (strong). Set the handle strength before the start of treatment. The treatment starts from low intensity and should be gradually increased according to the patient’s tolerance.
    • A B: Handle intensity of A and B,click【-】and【+】to adjust intensity.
    • C D: Handle intensity of C and D,click【-】and【+】to adjust intensity.
    • AB-RF: RF intensity of AB handle,click【-】and【+】to adjust intensity.
    • CD-RF: RF intensity of CD handle,click【-】and【+】to adjust intensity.
  7. Set the working time. The default working time of one treatment is 30 minutes. This can be adjusted from 5 minutes to 60 minutes.
  8. Click the Start button to start the treatment. Click the Pause button if you need to pause the treatment.

NOTE: Adjust the settings when the device is in Pause mode.

Pelvic Floor Cushion
  1. Align the handle with the socket on the back of the instrument and insert it; Insert the power cord into the rear socket of the device, turn ON the power switch, and the device will start immediately.
  2. Place a cushion on the chair, sit in the center, and relax.

NOTE:

  • Use MANUAL mode when using the Pelvic Floor Cushion
  • The recommended setting for F1: 110 Hz, F2: 5 Hz, and F3: 140 Hz

TREATMENT LEVELS IN AUTO MODE

MODE| STAGE 1| STAGE 2| STAGE 3| STAGE 4| STAGE 5| STAGE 6
---|---|---|---|---|---|---

M1

| 3 Hz/ 1 minute| 140 Hz/5 minutes| 4 Hz/ 1 minute| 200 Hz/5 minutes| 4 Hz/ 1 minute| 160 Hz/5 minutes

M2

| 5 Hz/ 1 minute| 200 Hz/5 minutes| 5 Hz/ 1 minute| 80 Hz/ 5 minutes| 5 Hz/ 1 minute| 140 Hz/5 minutes

M3

| 5 Hz/ 1 minute| 200 Hz/5 minutes| 5 Hz/ 1 minute| 160 Hz/5 minutes| 5 Hz/ 1 minute| 140 Hz/5 minutes

M4

| 4 Hz/ 1 minute| 160 Hz/5 minutes| 4 Hz/ 1 minute| 200 Hz/5 minutes| 4 Hz/ 1 minute| 160 Hz/5 minutes

M5

| 5 Hz/ 1 minute| 200 Hz/5 minutes| 5 Hz/ 1 minute| 160 Hz/5 minutes| 5 Hz/ 1 minute| 200 Hz/5 minutes
M1| Basic training for beginners ( suitable for people who hardly exercise, effective basic training for weak muscle groups )
---|---
M2| Adaptation training ( suitable for primary exercisers who have not exercised for a long time, and also suitable for obese people with fewer muscles )
M3| Preliminary training ( suitable for primary exercisers with insufficient muscle or slightly higher body fat, also suitable for slightly obese people)
M4| Advanced training ( suitable for intensive endurance training, suitable for all fitness groups and regular exercisers, and also suitable for obese people. As the training frequency further increases, the load is gradually increased to increase the strength and dimensionality of muscle contraction. For shaping.)
M5| Professional training ( suitable for intensive training, suitable for regular exercisers and athlete groups, and also suitable for obese people. Due to an increase in training frequency and high intensity of action, the fat-burning ability of muscles is improved, and fat is consumed at a high frequency.

TROUBLESHOOTING SOLUTIONS

Machine Error

| Cause|

Troubleshoot

---|---|---
Machine not working| 1.  Power plug not inserted

2.  Switch not ON

3.  Power fuse failure

| 1.  Check the power

2.  Check the switch

3.  Replace the fuse

Handle not working| Check if the connection is loose| Disconnect and reconnect the handle

MAINTENANCE

Regular Use

  • To make sure that the machine will last longer, after each 30 minutes of using the machine, allow the machine to rest/cool down for 5 minutes before starting the treatment again
  • Check the power socket, and confirm that there is a reliable connection to the ground
  • Check if the power cord is damaged before use, do not use it if damaged

Cleaning

  • Perform regular cleaning to ensure sanitation and proper function
  • The outside body of the machine can be cleaned using a damp cloth or alcohol wipes
  • Clean only when the machine is unplugged, and disconnected from the power source.

REJUVA FRESH, LLC

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

REJUVA FRESH User Manuals

Related Manuals