Instruction
-
THE LIGHTING FITTING SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN
Drill a hole into the ceiling with the above dimensions. Attention, respect the installation spaces as illustrated. -
1-10V diagram
DIMMABLE DRIVER WIRING (OPTIONAL)
DALI diagram
Re-connect the quick connection cable to the secondary output (SEC) of the dimmable driver. Pay attention to the polarities “+” and “-“. Connect the dimming devices wirings to the dimmable driver input in accordance with the connection diagrams above. For in-depth information, always refer to the detailed data sheets of the driver or tot he specific indication placed on board of it.
-
Connect the terminal box.
-
Insert the spotlight into the hole by lifting the side springs.
Insert the spotlight into the hole by lifting the side springs.
THE SAFETY AND RELIABILITY ARE GUARANTEED ONLY WHEN INSTALLATION INSTRUCTIONS
ARE PROPERLY FOLLOWED. PLEASE KEEP THIS INSTRUCTION SHEET FOR FUTURE REFERENCE
This product is provided with a light source with efficiency energy class
of:
| Light Source Model| Energy Efficiency Class| Light Source
(mA)| Light Source (V)
---|---|---|---|---
8021696248189 8021696248165 8021696267920
8021696267937| NOVA 12W 3000K
NOVA 12W 3000K
NOVA 12W 4000K
NOVA 12W 4000K| G
G
F
F| 300 mA
300 mA
300 mA
300 mA| 36 V DC
36 V DC
36 V DC
36 V DC
LEGENDA ICONE
-
Replaceable light source by an end-user
-
Replaceable LED light source by an end-user.
-
Replaceable light source by authorized personnel only.
-
Non-replaceable light source. Upon end of life of the light source, the whole product will be replaced.
-
Replaceable control gear by an end-user.
-
Replaceable light source by authorized personnel only.
-
Upon end of life of the control gear, the whole product will be replaced.
SAFETY INSTRUCTIONS
-
This fitting is produced and tested in accordance with the strictest European safety standards (ΕΝ 60.598-1).
-
This fitting cannot be disposed of as household waste. For disposal information ask the local authorities about how to collect it.
-
As indicated by specific regulations, the lighting fitting should be installed by a qualified electrician.
-
If the external wire is damaged it has to be replaced exclusively by the manufacturer, distributor or by a qualified electrician.
-
Always isolate power before commencing installation, maintenance or repair.
-
The luminary contains certain parts which can be very hot.
-
Each material requires specific mounting accessories. Use screws and wall plugs suitable for the material to which they are fastened. Those included may be unsuitable.
-
Always tighten the screws firmly to avoid contact problems.
-
This fitting should only be installed indoors.
-
Luminaries not suitable for recessed on normally flammable surfaces.
-
Luminaire not suitable for direct mounting on normal flammable surfaces.
-
This fitting is only suitable for fixing to the ceiling.
-
This fitting is only suitable for fixing to the wall.
-
The weight of the lamp has to be supported by the chain. Adjust the length of the electric wire so that it is longer than the chain.
-
Only use lamps which do not exceed the maximum specified wattage.
-
Always observe the minimum distance between the lamp and the surface being lit, as shown in the icon. The lamp can cause a fire if the minimum distance is not observed.
-
Auto-protected bulb. Only use bulbs marked with this symbol. Halogen bulbs get very hot. Wait until they cool down before replacing.
-
Cracked or broken safety glass has to be replaced immediately. Use only manufcturer approved parts complying with regulations.
-
Light source with not-substitute light emitting diode (LED). Do not disassemble the product since the diodes can damage the eyes. Do not immerse in water. Wipe with a damp cloth. Do not use solvents or strong detergents.
-
This fitting is equipped with a fuse. If the lamp is out of order, replace the internal fuse.
-
Class | Electrical safety guaranteed by the main insulation and an additional protective conduc- tor (earthing) connected with the metal frame of the lamp. Earthing is obligatory.
-
Class II Electrical safety guaranteed by the main insulation and a double or reinforced insulation.
Earthing not necessary. -
Class III Electrical safety guaranteed by very low power supply (less than 50 Volt). Earthing excluded.
-
Not protected.
-
Protected against solid objects greater than 50 mm.
-
Protected against solid objects greater than 12 mm.
-
Protected against solid objects greater than 2,5 mm.
-
Protected against solid objects greater than 1mm.
-
Dust protected.
-
Totally protected against dust infiltration.
-
Not protected.
-
Protected against vertically falling water drops.
-
Protected against water drops falling with a maximum angle of 15° to the vertical axis.
-
Protected against rain.
-
Protected against splashing water.
-
Protected against water jets.
-
Protected against strong water jets.
-
Protected against temporary immersion.
-
Protected against prolonged immersion.
-
Luminaire not suitable for covering with thermally insulating material.
-
Caution, risk of electric shock.
-
Do not stare at the operating light source.