handicare 5010 Easy Sliding Board User Manual

July 23, 2024
handicare

handicare-logo handicare 5010 Easy Sliding Board

handicare-5010-Easy-Sliding-Board-product

Specifications

  • Model: EasyGlide
  • Brand: SystemRoMedicTM
  • Safe Working Load (SWL): 150 – 250 kg / 330 – 550 lbs
  • Manual Number: 734 Ver. 11 150303

Product Information

The EasyGlide by SystemRoMedicTM is designed to assist with transferring individuals between surfaces, such as from bed to bed, with a safe working load of 150 – 250 kg (330 – 550 lbs). It is made of Polyethylene material and complies with Medical Device Class I standards.

Product Usage Instructions

Check Safety

  • Regularly inspect the condition and function of the EasyGlide.
  • Discard if there are signs of wear or fading. – Test the strength and durability by bending the board carefully.

Always Read the User Manual

  • Keep the user manual accessible.
  • Ensure you have the latest version.
  • Manuals are available for download at www.handicare.com.

Transfer from Bed to Bed

  • Place EasyGlide under the hips and shoulders of the user.
  • Use a draw sheet to facilitate the transfer.
  • Ensure weight is centered on EasyGlide.
  • Use a transfer slide between surfaces for smoother transfer.
  • Clean the surface with warm water or soap solution. Disinfect with ethanol or isopropanol if needed.

EasyGlide, extra long is a sliding board that is used for supine transfers of users from one bed or stretcher to another. EasyGlide, extra long is used when the gap is max. 15 cm/5,9’’. For safety reasons, EasyGlide extra long should have a firm underlying surface on both sides when transferring.
The rounded corners and the smooth, low-friction top surface provide for easy sliding transfers and make the sliding board very easy to position and remove. The double anti-slip tape on the underside prevents the board from sliding against the underlying surface during transfer.

Check Safety

Visual inspection
Check the condition and function of the assistive device regularly. Check to ensure that material is not worn or faded. If there are signs of wear, the product must be discarded.

Stability test
Carefully bend the assistive device to check strength and durability. The board should be both elastic and rigid. Discard the EasyGlide when its strength and durability are diminished.

Always read the user manual

Always read the user manuals for all assistive devices used during a transfer.
Keep the user manual where it is accessible to users of the product.
Always make sure that you have the right version of the user manual.
The most recent editions of user manuals are available for downloading from our website, www.handicare.com.

Important information

For the sake of safety, both underlying surfaces should be firm when transferring between bed and gurney. Do not leave the user unattended during a transfer situation.

handicare-5010-Easy-Sliding-Board-fig-2

Transfer from bed to bed

  • EasyGlide is placed under the hips and shoulders.
  • The user is turned on one side. A draw sheet can be used to facilitate the transfer. Guide the EasyGlide in under the user, between the bed sheet and the draw sheet. Press EasyGlide down into the mattress somewhat and push in.
  • Ensure that the weight of the hips and shoulders is centred on EasyGlide.
  • Transfer on transfer slide. Place the transfer slide between the two underlying surfaces. By using a draw sheet, the caregiver’s reach is extended, allowing a better working stance.
  • Make sure the transfer slide is between the two underlying surfaces and that the gap between the beds does not exceed 15 cm/5,9”. Lean the user towards the transfer slide and pull the draw sheet to transfer the user.
  • To remove, lean the user to one side and pull EasyGlide out.

handicare-5010-Easy-Sliding-Board-fig-3

Material
Polyethen

Care of the product
The surface of the product can be cleaned with warm water or a soap solution. If disinfection is needed, 70 % ethanol, 45 % isopropanol, or similar should be used.

Medical Device Class I

The product complies with the requirements of the Medical Devices Directive 93/42/EEC.
Contact your local distributor if you have any questions about the product and its use. See www.handicare.com for a complete list of distributors.

Expected lifetime
Up to 10 years of normal use

Contact Us

Handicare AB
Maskinvägen 17
SE-972 54 Luleå , SWEDEN
Tel: +46 (0)8-557 62 200
Fax:+46 (0)8-557 62 299
E-mail: info@handicare.se
www.handicare.com

FAQ

Q: How do I clean the EasyGlide?

A: The surface can be cleaned with warm water or a soap solution. For disinfection, use 70% ethanol, 45% isopropanol, or similar.

Q: What is the expected lifetime of the EasyGlide?

A: The expected lifetime is up to 10 years of normal use.

Q: What should I do if I have questions about the product?

A: Contact your local distributor or visit www.handicare.com for a list of distributors.