CRAFTSMAN CMXGIAC3300 Gas Inverter Generator Instruction Manual

August 7, 2024
Craftsman

CRAFTSMAN CMXGIAC3300 Gas Inverter Generator

Product Information

Specifications

Introduction and Safety
Thank you for choosing a CRAFTSMAN Inverter Generator. This product is designed to deliver high performance and efficient operation for various applications.

Safety Rules

  • Read and understand the manual completely before using the product.
  • Always provide the manual to any user of the generator.
  • Follow all safety instructions provided by the manufacturer.

Safety Symbols and Meanings

  • DANGER: Indicates a hazardous situation that may result in death or serious injury.
  • WARNING: Indicates a hazardous situation that could result in death or serious injury if not avoided.
  • CAUTION: Indicates a hazardous situation that could result in minor or moderate injury.
  • NOTE: Additional important information related to procedures.

Product Usage Instructions

Maintenance
Proper maintenance is essential for the efficient and safe operation of the inverter generator. Follow the maintenance schedule outlined in the manual.

Maintenance Schedule
Regular maintenance should include checking oil levels, spark plugs, air filters, and other components as per the schedule provided.

Preventive Maintenance
Perform preventive maintenance tasks to ensure optimal performance and longevity of the generator.

Engine Maintenance
Regularly inspect and service the engine components to keep the generator running smoothly.

Storage
When storing the generator, follow proper storage guidelines provided in the manual to prevent damage and ensure easy startup when needed.

Troubleshooting
If you encounter any issues with the generator, refer to the troubleshooting section in the manual for guidance on identifying and resolving common problems.

FAQ (Frequently Asked Questions)

  • Q: What should I do if the generator fails to start?

    • A: Check the fuel level, spark plug, and air filter. Ensure all connections are secure and follow the starting procedure outlined in the manual.
  • Q: How often should I change the oil in the generator?

    • A: Refer to the maintenance schedule provided in the manual. Typically, oil changes are recommended after a certain number of hours of operation.

Instruction Manual

Inverter Generator

CMXGIAC3300

IF YOU HAVE QUESTIONS OR COMMENTS, CONTACT US.

WARNING:   CANCER AND REPRODUCTIVE HARM www.P65Warnings.ca.gov . (000393a)

INTRODUCTION AND SAFETY

Introduction
Thank you for purchasing a CRAFTSMAN product. This unit has been designed to provide high-performance, efficient operation, and years of use when maintained correctly.

WARNING: Consult Manual. Read and understand manual completely before using product. Failure to completely understand manual and product could result in death or serious injury. (000100a)

If any section of the manual is not understood, contact your nearest Service Center, or contact CRAFTSMAN at 1-888-331-4569, or WWW.CRAFTSMAN.COM with an y questions or concerns.

The owner is responsible for proper maintenance and safe use of the equipment. Before operating, servicing, or storing this generator

  • Study all warnings in this manual and on the product carefully.
  • Become familiar with this manual and the unit before use.
  • See Assembly section of the manual for instructions on final assembly procedures. Follow the instructions completely.

Save these instructions for future reference. ALWAYS supply this manual to any individual that will use this product.

The information in this manual is accurate based on products produced at the time of publication. The manufacturer reserves the right to make technical updates, corrections, and product revisions at any time without notice.

Safety Rules

  • The manufacturer cannot anticipate every possible circumstance that might involve a hazard. The warnings in this manual, and on tags and decals affixed to the uni t are, therefore, not all inclusive. If using a procedure, work method, or operating technique that the manufacturer does not specifically recommend, verify that it is safe fo r others and does not render the equipment unsafe.
  • Throughout this publication, and on tags and decals affixed to the generator, DANGER, WARNING, CAUTION, and NOTE blocks are used to alert personnel to special instructions about a particular operation that may be hazardous if performed incorrectly or carelessly. Observe them carefully.
  • These safety warnings cannot eliminate the hazards that they indicate. Common sense and strict compliance with the special instructions while performing the action or service are essential to preventing accidents.

Safety Symbols and Meanings

DANGER: Indicates a hazardous situation which, i f not avoided, will result in death or serious injury.
WARNING: Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION: Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTE: Notes contain additional information important to a procedure and will be found within the regular text of this manual.

Carbon Monoxide Hazards and Meanings

DANGER

Using a generator indoors CAN KILL YOU IN MINUTES.

Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.


NEVER use inside a home or garage, EVEN IF doors and windows are open.

| ****

Only use OUTSIDE and far away from windows, doors, and vents.

  • DANGER: Asphyxiation. Running engines produce carbon monoxide, a colorless, odorless, poisonous gas. Carbon monoxide, if not avoided, will result in death or serious injury. (000103)
  • DANGER: Asphyxiation. The exhaust system must be properly maintained. Do not alter or modify the exhaust system as to render it unsafe or make it noncompliant with local codes and/or standards. Failure to do so will result in death or serious injury. (000179b)
  • WARNING: Asphyxiation. Always use a batter y operated carbon monoxide alarm indoors and installed according to the manufacturer’s instructions. Failure to do so could result in death or serious injury. (000178a)

If you start to feel sick, dizzy, or weak after the generator has been running, move to fresh air IMMEDIATELY. See a doctor, as you could have carbon monoxide poisoning.

Electrical Hazards

  • DANGER: Electrocution. Contact with bare wires, terminals, and connections while generator is running will result in death or serious injury. (000144)
  • DANGER: Electrocution. Water contact with a power source, if not avoided, will result in death or serious injury. (000104)
  • DANGER: Electrocution. In the event of electrical accident, immediately shut power OFF. Use non-conductive implements to free victim from liv e conductor. Apply first aid and get medical help. Failure to do so will result in death or serious injury. (000145)
  • DANGER: Electrocution. Turn utility and emergency power supplies to OFF before connecting power source and load lines. Failure to do so will result in death or serious injury. (000116)
  • WARNING: Equipment and property damage. Do not alter construction of, installation, or bloc k ventilation for generator. Failure to do so could result in unsafe operation or damage to the generator. (000146)
  • The National Electric Code (NEC) requires the frame and external electrically conductive parts of the generator be correctly connected to an approved earth ground. Local electrical codes may also require correct grounding of the generator. Consult with a local electrician for grounding requirements in the area.
  • Use a ground fault circuit interrupter in any damp or highly conductive area (such as metal decking or steel work).
  • Once generator has been started outside, connect electrical loads to extension cord(s) inside.

Exhaust and Location Hazards

  • DANGER: Asphyxiation. Running engines produce carbon monoxide, a colorless, odorless, poisonous gas. Carbon monoxide, if not avoided, will result in death or serious injury. (000103)
  • DANGER: Asphyxiation. The exhaust system mus t be properly maintained. Do not alter or modify th e exhaust system as to render it unsafe or make i t noncompliant with local codes and/or standards. Failure to do so will result in death or seriou s injury. (000179b)
  • WARNING: Equipment and property damage. Do not alter construction of, installation, or bloc k ventilation for generator. Failure to do so could result in unsafe operation or damage to the generator. (000146)
  • WARNING: Asphyxiation. Always use a batter y operated carbon monoxide alarm indoors an d installed according to the manufacturer’s instructions. Failure to do so could result in deat h or serious injury. (000178a)
  • If you start to feel sick, dizzy, or weak after the generator has been running, move to fresh air IMMEDIATELY. See a doctor, as you could have carbon monoxide poisoning.
  • NEVER run a generator indoors or in a partly enclose d area such as garages.
  • ONLY use outdoors and far away from windows, doors, vents, crawl spaces and in an area where adequate ventilation is available and will not accumulate deadly exhaust gas.
  • Using a fan or opening a door will not provide sufficient ventilation.
  • Point muffler exhaust away from people and occupied buildings.

Fire Hazards

  • DANGER: Explosion and Fire. Fuel and vapors are extremely flammable and explosive. Add fuel in a well ventilated area. Keep fire and spark away. Failure to do so will result in death or serious injury. (000105)
  • DANGER: Explosion and Fire. Do not fill fuel tank past full line. Allow for fuel expansion. Overfilling may cause fuel to spill onto engine causing fire o r explosion, which will result in death or serious injury. (000214)
  • WARNING: Personal injury. Do not insert an y object through the air cooling slots. Generator can start at any time and could result in death, serious injury, and unit damage. (000142a)
  • WARNING: Fire risk. Fuel and vapors are extremely flammable. Do not operate indoors. Doing so could result in death, serious injury, or property or equipment damage. (000281)
  • WARNING: Explosion and fire risk. Do not smoke near unit. Keep fire and spark away. Failure to d o so could result in death, serious injury, or property or equipment damage. (000282)
  • WARNING: Explosion and Fire. Do not smoke while refueling unit. Failure to do so could result in death, serious injury, or property or equipment damage. (000284a)
  • Allow at least 5 ft (1.5 m) of clearance on all sides of the generator when operating to prevent overheating and fire.
  • Do not operate the generator if connected electrical devices overheat, if electrical output is lost, if engine or generator sparks, or if flames or smoke are observe d while unit is running.
  • Keep a fire extinguisher near the generator at all times.

Service/General Hazards

  • WARNING: Equipment and property damage. D o not operate unit on uneven surfaces, or areas of excessive moisture, dirt, dust or corrosive vapors. Doing so could result in death, serious injury, property and equipment damage. (000250)
  • WARNING: Moving parts. Keep clothing, hair, an d appendages away from moving parts. Failure t o do so could result in death or serious injury. (000111)
  • WARNING: Hot surfaces. When operating machine, do not touch hot surfaces. Keep machine away from combustibles during use. Hot surfaces could result in severe burns or fire. (000108)
  • WARNING: Personal injury. Do not insert an y object through the air cooling slots. Generator can start at any time and could result in death, serious injury, and unit damage. (000142a)
  • WARNING: Injury and equipment damage. Do not use generator as a step. Doing so could result in falling, damaged parts, unsafe equipment operation and could result in death or serious injury. (000216)
  • WARNING: Equipment damage. Do not attempt t o start or operate a unit in need of repair or scheduled maintenance. Doing so could result in death, serious injury, or equipment failure or damage. (000291)
  • WARNING: Equipment and property damage. Do not alter construction of, or installation of primary fuel tank. Doing so could result in death or serious injury, unsafe operation or generator damage. (000208)
  • WARNING: Risk of injury. Do not operate or service this machine if not fully alert. Fatigue can impair the ability to service this equipment and could result in death or serious injury. (000215)
  • For safety reasons, it is recommended that the maintenance of this equipment be performed by a Service Cen-ter. Inspect the generator regularly, and contact the nearest Service Center for parts needing repair or replacement.

Standards Index

  1. National Fire Protection Association (NFPA) 70: The NATIONAL ELECTRIC CODE (NEC) available from www.nfpa.org
  2. National Fire Protection Association (NFPA) 5000: BUILDING CONSTRUCTION AND SAFETY CODE available from www.nfpa.org
  3. International Building Code available from www.iccsafe.org
  4. Agricultural Wiring Handbook available from www.rerc.org , Rural Electricity Resource Council P.O. Box 309 Wilmington, OH 45177-0309
  5. ASAE EP-364.2 Installation and Maintenance of Farm Standby Electric Power available from www.asabe.org , American Society of Agricultural & Biological Engineers 2950 Niles Road, St. Joseph, MI 49085
  6. CSA C22.2 100-14 Electric motors and generators for installation and use, in accordance with the Rules of the Canadian Electrical Code
  7. ANSI/PGMA G300 Safety and Performance of Portable Generators. Portable Generator Manufacturer’s Association, www.pgmaonline.com

Accessories
WARNING: Personal injury. Use of accessories no t offered by CRAFTSMAN could be hazardous an d result in death, serious injury, and unit damage. (000589)

Recommended accessories for use with this machine are available at extra cost from a local dealer or service center. For assistance, call 1-888-331-4569.

Register Online

  • WARRANTY SERVICE : Registering the product will help obtain warranty service if there is a problem with the product.
  • CONFIRMATION OF OWNERSHIP : In case of an insurance loss, such as fire, flood or theft, the registration of owner-ship will serve as proof of purchase.
  • FOR YOUR SAFETY : Registering the product will allow us to contact you in the unlikely event a safety notification is required under the Federal Consumer Safety Act.

GENERAL INFORMATION AND SETUP

Generator Components

  1. Low Oil LED (Yellow)
  2. Overload LED (Red)
  3. AC Power LED (Green)
  4. Parallel Ports
  5. 1A/2.1A, 5 VDC USB Outlets
  6. Circuit Breakers
  7. Grounding Location
  8. 120V, 20A Duplex Outlets
  9. 120V, 30A Outlet (NEMA L5-30R)
  10. Carrying Handle
  11. Fuel Cap
  12. Control Panel
  13. Start Dial (OFF/RUN/CHOKE)
  14. Recoil Starter
  15. Muffler
  16. Oil Fill/Drain
  17. Air Cleaner
  18. Carburetor
  19. Spark Plug
  20. Spark Arrestor
  21. CO Detection (if equipped)

Know Your Generator

WARNING: Consult Manual. Read and understand manual completely before using product. Failure to completely understand manual and product could result in death or serious injury. (000100a)

Replacement instruction manuals are available at WWW.CRAFTSMAN.COM .
FREE WARNING LABEL REPLACEMENT: If an y warning labels become illegible or are missing, call 1-888-331-4569 for a free replacement.

Emissions
The United States Environmental Protection Agency (US EPA) (and California Air Resources Board (CARB), for engines/equipment certified to California standards) requires that this engine/equipment complies with exhaust and evaporative emissions standards. Locate the emissions compliance decal on the engine to determine applicable standards. For emissions warranty information, please reference the included emissions warranty. I t is important to follow the maintenance specifications in the manual to ensure that the engine complies with the applicable emissions standards for the duration of the product’s life.

Generator Specifications CMXGIAC3300
Rated power 2500 W**
Surge power 3300 W
Rated AC voltage 120V
Rated AC load at 120V 20.83 Amps**
Rated frequency 60 Hz
Dimensions L x W x H (in / cm) 23.03 x 14.06 x 18.39 / 58.5 x 35.7 x 46.7
Weight (dry) 61.2 lb (27.8 kg)

** Operating Temperature Range: 8 °F (-13 °C) to 104 °F (40 °C). When operated above 77 °F (25 °C) there may be a decrease in power.

** Maximum wattage and current are subject to, and limited by, such factors as fuel Btu content, ambient temperature, altitude, engine condition, etc. Maximum power decreases about 3.5% for each 1,000 ft (304.8 m) above sea level; and will also decrease about 1% for each 10 °F (6 °C) above 60 °F (16 °C) ambient temperature.

Engine Specifications| CMXGIAC3300
Engine type| Single Cylinder, 4-stroke
Displacement| 149 cc
Spark plug part number| 0K95530157
Spark plug type| E6TC / E6RTC / BP6HS or equivalent
Spark plug gap (in / mm)| 0.024-0.028 / 0.6-0.7
Fuel capacity / type| 1.06 U.S. gallons (4.0 L) / Unleaded
Oil type| See Add Engine Oil section
Oil capacity| 0.6 qt (0.6 L)
Run time at 25% load| 7 Hours
Run Time at 50% load| 4.5 Hours

Outlets

120 VAC, Duplex Outlet
The 120 volt outlet is overload protected by the 20 amp push button circuit protector (Fig. C).

120 VAC, 30 Amp Outlet

Use a NEMA L5-30R plug with this outlet. Connect a suit-able 3-wire cord set to the plug and to desired load. Th e cord set should be rated for 125 volts AC at 30 amps (o r greater) (Fig. D).

Use this outlet to operate 120 volts AC, 60 Hz, single-phase loads requiring up to 3300 Watts, 27.5 amps start-ing power and 2500 Watts of continuous power at 20.83 amps. The outlet is protected by a 20 amp push-to-reset circuit breaker.

Start Dial (OFF/RUN/CHOKE)
This controls the ON/OFF functions, choke, and fuel valve operation (Fig. E).

  • The OFF position 1 stops the engine and shuts off fuel flow.
  • The RUN position 2 is for normal operation and t o gradually reduce the use of the choke.
  • The CHOKE position 3 switches the fuel valve on t o start the engine.

NOTE: CHOKE is not required to start a warm engine.

USB Outlets
The 1A/2.1A, 5 VDC USB outlets allow charging of compatible electronic devices.

Generator Status Lights
See Fig. F.

  • Overload LED (red): Indicates system overload 2 . During motor starting, it is normal for the overload LE D to illuminate for a few seconds. If LED stays illuminated and the ready LED turns off, the engine will continue to run without output power. Remove all applied loads and determine if attached devices exceed recommended output power. Inspect for faulty or shorted connections. To restore electrical output, rotate Start Dial OFF to reset. Start engine. If condition was corrected, the red LED will not illuminate and electrical output will be restored. Loads can be applied once the green LED illuminates. If the red LED returns, contact a Service Dealer.
  • Low Oil Level LED (yellow): Illuminates when oil level is below safe operating level. Engine shuts down 1 .
  • Power LED (green) : Indicates output from generator 3 (unless there is a low oil or overload condition).

Circuit Breakers
The AC receptacles are protected by an AC circuit breaker. If the generator is overloaded or an external short circuit occurs, the circuit breaker will trip. If this occurs, disconnect all electrical loads to determine the cause of the problem before using the generator again. Reduce the load if the circuit breaker is tripped.

NOTE: Continuous tripping of the circuit breaker may cause damage to generator or equipment.

Push the button of the breaker to reset circuit breaker.

CO Detection
Carbon Monoxide (CO) Detection and Shutoff System (if equipped)

DANGER: Asphyxiation. Running engines produce carbon monoxide, a colorless, odorless, poisonous gas. Carbon monoxide, if not avoided, will result in death or serious injury. (000103)
WARNING: Asphyxiation. Always use a batter y operated carbon monoxide alarm indoors an d installed according to the manufacturer’s instructions. Failure to do so could result in death or serious injury. (000178a)

  • The CO Detection module monitors for the accumulation of poisonous CO gas found in engine exhaust when the generator is running. CO Detection automatically shuts off the engine if it detects increasing levels of C O gas. CO Detection only monitors when the engine is running. Generators are intended to be used outdoors, far from occupied buildings, with the exhaust pointe d away from personnel and buildings. However, if misuse d and operated in a location which results in the accumulation of CO—like indoors or in a partially enclosed area—CO Detection shuts off the engine, notifies the user of what has happened, and directs the user to read the instruction action label for steps to take (Fig. H). CO Detection is not a substitute for an indoor carbon mon-oxide alarm.
  • As the user approaches the generator to investigate a shutoff, a blinking RED light in the CO Detection badge on the side of the generator notifies the user the genera-tor was shutoff due to an accumulating CO hazard. Th e RED light will blink for at least five minutes after a C O shutoff. Move the generator to an open, outdoor area and point the exhaust away from people and occupied buildings. Once relocated to a safe area, the generator can be restarted and the correct electrical connections made to supply electrical power. The RED light will stop blinking automatically upon engine start. Introduce fresh air and ventilate the location where the generator had shut down.
  • If a CO Detection system fault has occurred and no longer provides protection, the portable generator shuts off automatically, and the YELLOW light in the CO Detection badge will blink for at least five minutes to notify the user of the fault. The CO Detection module can only be diagnosed and repaired by a trained technician at the dealer. The generator can be started, but may continue to shutoff.
  • CO Detection will detect the accumulation of CO from other fuel burning sources such as engine powered tool s or propane heaters used in the area of operation. For example, if another generator is used and the exhaust is pointed at a CO Detection equipped generator, C O Detection may initiate a shutoff due to rising CO levels. This is not an error as hazardous CO has been detected. The user must take action to move and redirect these devices to better dissipate CO far away from personnel and occupied buildings.
  • See Fig. G. IF red LED A is flashing, a CO Shutoff ha s occurred.
  • IF yellow LED B is flashing, a CO System Fault ha s occurred.

Remove Contents from Carton

  1. Open carton completely by cutting each corner from top to bottom.
  2. Remove and verify carton contents prior to assembly. Carton contents should contain the following:

Accessories

Item Qty.
Inverter generator 1
Instruction manual 1
Engine oil 1
Oil funnel 1
Tool kit 1
Product registration card 3
Service warranty 1
Emissions warranty 1
  1. Call Customer Service at 1-888-331-4569 with the unit model and serial number for any missing car-ton contents.
  2. Record model, serial number, and date of purchase on front cover of this manual.

Add Engine Oil
CAUTION: Engine damage. Verify proper type and quantity of engine oil prior to starting the engine. Failure to do so could result in engine damage. (000135)

NOTE: The generator is shipped without oil in the engine. Add oil slowly and verify oil level often during filling process to prevent overfilling.
See Fig. I and Fig. J.

  1. Place generator on a level surface.

  2. Remove screws and side cover.

  3. Verify oil fill area is clean.

  4. Remove oil fill cap/oil dipstick and wipe oil dipstick clean.

  5. Insert funnel into oil fill opening. Add recommended engine oil as necessary. Climate deter-mines required engine oil viscosity. See chart below to select correct viscosity.
    NOTE: Use petroleum based oil (supplied) for engine break-in before using synthetic oil.

  6. Remove funnel and insert oil dipstick into oil filler neck. Do not screw in.

  7. Remove oil dipstick and verify oil level is within safe operating range.
    NOTE: Verify oil level often during filling process to prevent overfilling.

  8. Install oil fill cap/oil dipstick and hand-tighten.

  9. Install side cover and screws.

Fuel

DANGER: Explosion and Fire. Fuel and vapors are extremely flammable and explosive. Add fuel in a well ventilated area. Keep fire and spark away. Failure to do so will result in death or serious injury. (000105)

DANGER: Explosion and Fire. Do not fill fuel tan k past full line. Allow for fuel expansion. Overfilling may cause fuel to spill onto engine causing fire or explosion, which will result in death or serious injury. (000214)

Fuel requirements are as follows

  • Clean, fresh, unleaded gasoline.
  • Minimum rating of 87 octane/87 AKI (91 RON).
  • Up to 10% ethanol (gasohol) is acceptable (where available; non-ethanol fuel is recommended).
  • DO NOT use E85.
  • DO NOT use a gas oil mix.
  • DO NOT modify engine to run on alternate fuels. Stabilize fuel prior to storage.
  1. Verify unit is OFF and cooled entirely prior to fueling.
  2. Place unit on level ground in a well ventilated area.
  3. Clean area around fuel cap.
  4. Turn fuel cap slowly to remove.
  5. Slowly add recommended fuel. Do not overfill.
  6. Install fuel cap.

NOTE: Allow spilled fuel to evaporate before starting unit.

IMPORTANT NOTE: It is important to prevent gum depos-its from forming in fuel system parts such as the carburetor, fuel hose or tank during storage. Alcohol-blended fuels (called gasohol, ethanol, or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic gas can damage the fuel system of an engine while in storage. To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer. See the Storage section. Never use engine or carburetor cleaner products in the fuel tank as permanent damage may occur.

OPERATION

Operation and Use Questions
Call Customer Service at 1-888-331-4569 with questions or concerns about equipment operation and maintenance.

Before Starting Engine

  1. Verify engine oil level is correct.
  2. Verify fuel level is correct.
  3. Verify unit is secure on level ground, with correct clearance, and is in a well ventilated area.

Prepare Generator for Use

  • DANGER: Asphyxiation. Running engines produce carbon monoxide, a colorless, odorless, poisonous gas. Carbon monoxide, if not avoided, will result in death or serious injury. (000103)
  • DANGER: Asphyxiation. The exhaust system must be properly maintained. Do not alter or modify the exhaust system as to render it unsafe or make i t noncompliant with local codes and/or standards. Failure to do so will result in death or serious injury. (000179b)
  • WARNING: Risk of fire. Do not use generator with-out spark arrestor installed. Failure to do so could result in death or serious injury. (000118a)
  • WARNING: Asphyxiation. Always use a batter y operated carbon monoxide alarm indoors an d installed according to the manufacturer’s instructions. Failure to do so could result in death or serious injury. (000178a)
  • WARNING: Risk of Fire. Hot surfaces could ignite combustibles, resulting in fire. Fire could result i n death or serious injury. (000110)
  • WARNING: Hot surfaces. When operating machine, do not touch hot surfaces. Keep machine away from combustibles during use. Hot surfaces could result in severe burns or fire. (000108)
  • CAUTION: Equipment and property damage. Dis-connect electrical loads prior to starting or stop-ping unit. Failure to do so could result i n equipment and property damage. (000136)

Grounding Generator When In Use
See Fig. K. The generator is equipped with an equipment ground connecting the generator frame and the ground terminals on the AC output outlets (see NEC 250.34) A . This allows the generator to be used as a portable generator without grounding the frame of the generator as specified in NEC 250.34.

Neutral Floating

The generator (stator winding) is isolated from the fram e and from the AC outlet ground pin. Electrical device s requiring a grounded outlet pin connection will not function if the outlet ground pin is not functional.

Know Generator Limits
Overloading a generator can result in damage to the generator and connected electrical devices. Observe the following to prevent overload

  • Add the total wattage of all electrical devices to be connected at one time. This total should NOT be greater than the generator’s wattage capacity.
  • The rated wattage of lights can be taken from light bulbs. The rated wattage of tools, appliances, and motors can be found on a data label or decal affixed to the device.
  • If the appliance, tool, or motor does not give wattage, multiply volts times ampere rating to determine watts (volts x amps = Watts).
  • Some electric motors, such as induction types, require approximately three times more Watts of power for starting than for running. This surge of power lasts on ly a few seconds when starting such motors. Allow for higher starting wattage when selecting electrical devices to connect to the generator:
  1. Calculate wattage needed to start the largest motor.
  2. Add the running Watts of all other connected loads to that figure.

The Wattage Reference Guide is provided to assist in determining how many items the generator can operate at one time.

NOTE: All figures are approximate. See data label on appliance for wattage requirements.

Wattage Reference Guide

Device Running Watts
*Air Conditioner (12,000 BTU) 1700
*Air Conditioner (24,000 BTU) 3800
*Air Conditioner (40,000 BTU) 6000
Battery Charger (20 Amp) 500
Belt Sander (3″) 1000
Chain Saw 1200
Circular Saw (7-1/4″) 1250 to 1400
*Clothes Dryer (Electric) 5750
*Clothes Dryer (Gas) 700
*Clothes Washer 1150
Coffee Maker 1750
*Compressor (1 HP) 2000
*Compressor (3/4 HP) 1800
*Compressor (1/2 HP) 1400
Curling Iron 700
*Dehumidifier 650
Disc Sander (9″) 1200
Edge Trimmer 500
Electric Blanket 400
Electric Nail Gun 1200
Electric Range (per element) 1500
Electric Skillet 1250
*Freezer 700
*Furnace Fan (3/5 HP) 875
*Garage Door Opener 500 to 750
Hair Dryer 1200
Hand Drill 250 to 1100
Hedge Trimmer 450
Impact Wrench 500
Iron 1200
*Jet Pump 800
Lawn Mower 1200
Light Bulb 100
Microwave Oven 700 to 1000
*Milk Cooler 1100
Oil Burner on Furnace 300
Oil Fired Space Heater (140,000 BTU) 400
Oil Fired Space Heater (85,000 BTU) 225
Oil Fired Space Heater (30,000 BTU) 150
*Paint Sprayer, Airless (1/3 HP) 600
Paint Sprayer, Airless (hand-held) 150
Radio 50 to 200
*Refrigerator 700
--- ---
Slow Cooker 200
*Submersible Pump (1-1/2 HP) 2800
*Submersible Pump (1 HP) 2000
*Submersible Pump (1/2 HP) 1500
*Sump Pump 800 to 1050
*Table Saw (10″) 1750 to 2000
Television 200 to 500
Toaster 1000 to 1650
Weed Trimmer 500
  • Allow three times the listed Watts for starting these devices.

Transporting/Tipping of the Unit
Do not store or transport the unit at an angle greater than 15 degrees.

Starting Pull Start Engines

WARNING: Recoil hazard. Recoil could retract unexpectedly. Kickback could result in death or serious injury. (000183)
CAUTION: Equipment and property damage. Disconnect electrical loads prior to starting or stop-ping unit. Failure to do so could result in equipment and property damage. (000136)

See Fig. L and Fig. M.

  1. Rotate Start Dial to CHOKE 1 .
  2. Firmly grasp recoil handle and pull slowly until increased resistance is felt. Pull rapidly up and away.
  3. When engine starts, rotate Start Dial to RUN 2 . Choke operation is reduced as Start Dial is rotate d towards RUN.

NOTE: If engine fires, but does not continue to run, rotate the Start Dial to OFF and repeat starting instructions.

IMPORTANT NOTE : Do not overload generator or individual panel outlets. If an overload occurs, the overload LED A will illuminate and AC output ceases. To correct , see Generator Status Lights. Read Know Generator Lim-its carefully.

Generator Shut Down
CAUTION: Equipment and property damage. Dis-connect electrical loads prior to starting or stopping unit. Failure to do so could result in equipment and property damage. (000136)

  1. Shut off all loads and unplug electrical loads fr om generator panel outlets.
  2. Let engine run at no-load for several minutes to stabilize internal temperatures of engine and genera-tor.
  3. Rotate Start Dial to OFF 3 . See Fig. L.

Starting Hot Engines

CAUTION: Equipment and property damage. Dis-connect electrical loads prior to starting or stop-ping unit. Failure to do so could result in equipment and property damage. (000136)

  1. Rotate Start Dial from OFF to RUN. This will open the fuel valve and permit starting. See Fig. L.
  2. Firmly grasp recoil handle and pull slowly until increased resistance is felt. Pull rapidly up and away.

Low Oil Level Shutdown System
The engine is equipped with a low oil level sensor that shuts down the engine automatically when the oil level drops below a specified level to prevent engine damage
B . The engine will not run until the oil has been filled to the correct level. See Fig. M.

IMPORTANT NOTE : Verify correct engine oil and fuel levels before use.

Parallel Operation
For output power up to 5000 running Watts, two inverters can operate in parallel using Parallel Kit (optional). See the Parallel Kit Operator’s Manual or contact Customer Service at 1-888-331-4569.

NOTE: All connections to the parallel kit should be mad e while both inverters are turned off and all loads disconnected.

  1. Make appropriate parallel connections to the outlets on each inverter as outlined in the owner’ s manual supplied with the kit.
    NOTE: Do not disconnect any parallel kit connections once the units are running.

  2. Start both units per starting instructions. Once the green output indicator illuminates, devices can be connected and turned on using the parallel kit out-let.

  3. Follow Generator Shut Down instructions.
    NOTE: Only use approved parallel kit.

MAINTENANCE AND TROUBLESHOOTING

Maintenance
Regular maintenance will improve performance and extend engine/equipment life. Contact Customer Ser-vice at 1-888-331-4569, or WWW.CRAFTSMAN.COM to find a dealer for maintenance work to be performed. Regular maintenance, replacement or repair of the emissions control devices and systems may be performed by any repair shop or person of the owner’s choosing. How-ever, to obtain emissions control warranty service free of charge, the work must be performed by a CRAFTSMAN service dealer. See the emissions warranty.

NOTE : Call 1-888-331-4569 with questions about component replacement.

Maintenance Schedule
Follow maintenance schedule intervals, whichever occurs first according to use.

NOTE: Adverse conditions will require more frequent service.

NOTE: All required service and adjustments should be completed as detailed in the following chart.

Before Each Use

Check engine oil level
Every 100 Hours or Every Six Months
Clean/replace air filter*
Change oil ¥
Clean/replace spark arrestor
Every 300 Hours or Every Year

Inspect/replace spark plug
Replace fuel filter +
Valve clearance adjustment
Clean/replace crankcase breather hose
Inspect fittings/fasteners +
¥ Change oil after first month or 20 hours of operation.

  • + To be performed by a Service Dealer.
    • Change oil every month when operating under heavy load or in high temperatures.
  • ** Clean more often under dirty or dusty operating conditions. Replace air filter parts if they cannot be adequately cleaned.
  • *** Check valve clearance and adjust if necessary after first 50 hours of operation and every 300 hours thereafter.

Preventive Maintenance
WARNING: Personal injury. Do not insert an y object through the air cooling slots. Generator can start at any time and could result in death, serious injury, and unit damage. (000142a)

Dirt or debris can cause incorrect operation and equipment damage. Clean generator daily or before each use. Keep area around and behind muffler free from combustible debris. Inspect all cooling air openings on generator.

  • Use a damp cloth to wipe exterior surfaces clean.
  • Use a soft bristle brush to loosen caked on dirt, oil, etc.
  • Use a vacuum to pick up loose dirt and debris.
  • Low pressure air (not to exceed 25 psi) may be used to blow away dirt. Inspect cooling air slots and openings on generator. These openings must be kept clean and unobstructed.

NOTE: DO NOT use a garden hose to clean generator. Water can enter engine fuel system and cause problems. If wate r enters generator through cooling air slots, some water will be retained in voids and crevices of rotor and stator wind-ing insulation. Water and dirt buildup on generator internal windings will decrease insulation resistance of windings.

Engine Maintenance

WARNING: Personal injury. Do not insert an y object through the air cooling slots. Generator can start at any time and could result in death, serious injury, and unit damage. (000142a)
WARNING: Accidental start-up. Disconnect spark plug wires when working on unit. Failure to do so could result in death or serious injury. (000141)

Engine Oil Recommendations
To maintain the product warranty, the engine oil should be serviced in accordance with the recommendations of this manual. For your convenience, service items designed and intended for use on this product are avail-able from the manufacturer including engine oil, spark plug(s), a shop towel, and a funnel. These items can be obtained by contacting Customer Service at 1-888-331-4569.

Inspect Engine Oil Level
WARNING: Risk of burns. Allow engine to cool before draining oil or coolant. Failure to do s o could result in death or serious injury. (000139)

Inspect engine oil level prior to each use, or every eight hours of operation.

  1. Place generator on a level surface.

  2. Remove screws and side cover.

  3. Clean area around oil fill.

  4. Remove oil fill cap/oil dipstick and wipe oil dipstick clean (Fig. N).

  5. Insert oil dipstick into oil filler neck. Do not screw it in (Fig. O).

  6. Remove oil dipstick and verify oil level is within safe operating range.

  7. Add recommended engine oil as necessary.
    NOTE: Verify oil level often during filling process to prevent overfilling.

  8. Install oil fill cap/oil dipstick and hand-tighten.
    NOTE: Some units have more than one oil fill location. It i s only necessary to use one oil fill point.

  9. Install side panel and screws.

Change Engine Oil
WARNING: Accidental start-up. Disconnect spar k plug wires when working on unit. Failure to do so could result in death or serious injury. (000141)

When using generator under extreme, dirty, or dust y conditions, or in extremely hot weather, change oil more frequently.

NOTE: Don’t pollute. Conserve resources. Return used oil t o collection centers.

Change oil while engine is still warm from running, as follows

  1. Place generator on a level surface.

  2. Remove screws, side cover, and spark plug cover.

  3. Disconnect the spark plug wire from the spark plug and place spark plug wire where it cannot contact spark plug.

  4. Clean area around oil fill and oil drain plug.

  5. Remove oil fill cap/oil dipstick and wipe oil dipstick clean.

  6. Tip unit and drain oil completely into a suitable container.

  7. Install oil drain plug and tighten securely.

  8. Insert funnel into oil fill opening (Fig. P). Add recommended engine oil as necessary.

  9. Remove funnel and insert oil dipstick into oil filler neck. Do not screw in. (Fig. O)

  10. Remove oil dipstick and verify oil level is within safe operating range.
    NOTE: Verify oil level often during filling process to prevent overfilling.

  11. Install oil fill cap/oil dipstick and hand-tighten.

  12. Wipe up any spilled oil.

  13. Connect spark plug wire.

  14. Install side panel, screws, and spark plug cover.

  15. Dispose of used engine oil in accordance with all applicable regulations.

Air Filter
Engine will not run correctly and may be damaged if run with a dirty air filter. Service air filter more frequently in dirty or dusty conditions.

To service air filter (Fig. Q)

  1. Remove bolt A and remove air filter cover.
  2. Wash filter B in soapy water. Squeeze dry in clean cloth (DO NOT TWIST).
  3. Clean air filter cover before installation.
  4. Install side cover and screws.

NOTE: To order a new air filter, contact the nearest Service Center.

Service Spark Plug
To service spark plug

  1. Remove spark plug cover and disconnect spark plug wire. Place spark plug wire where it cannot contact spark plug.
  2. Clean area around spark plug.
  3. Remove and inspect spark plug.
  4. Inspect electrode gap with feeler gauge and set spark plug gap to 0.6–0.7 mm (0.024–0.028 in) (Fig. R) NOTE: Replace spark plug if electrodes are pitted, burned, or porcelain is cracked. Use ONLY recommended replacement plug. See Product Specifications.
  5. Install spark plug finger tight, and tighten an additional 3/8 to one-half turn using spark plug wrench.
  6. Connect spark plug wire and install spark plug cover.

Inspect Muffler and Spark Arrester
NOTE: It is a violation of California Public Resource Code, Section 4442, to use or operate the engine on any forest-covered, brush-covered, or grass- covered land unless the exhaust system is equipped with a spark arrester, a s defined in Section 4442, maintained in effective working order. Other states or federal jurisdictions may have similar laws.

original equipment manufacturer, retailer, or dealer to obtain a spark arrester designed for exhaust system installed on this engine.

NOTE: Use ONLY original equipment replacement parts.
Inspect muffler for cracks, corrosion, or other damage. Remove spark arrester, if equipped, and inspect for dam-age or carbon blockage. Replace parts as required.

Inspect Spark Arrester Screen

WARNING: Hot surfaces. When operating machine, do not touch hot surfaces. Keep machine away from combustibles during use. Hot surfaces could result in severe burns or fire. (000108)

Clean Spark Arrestor Screen

The engine exhaust muffler has a spark arrestor screen. Inspect and clean the screen every 100 hours of operation or every six months, whichever comes first.

To service spark arrestor (Fig. S)

  1. Remove the clamp to remove retainer.
  2. Slide spark arrestor screens out from the muffler outlet tube.
  3. Inspect spark arrestor screens and replace if torn, perforated, or otherwise damaged. Do NOT use a faulty spark arrestor screen. If spark arrestor screen is not damaged, clean with a commercial solvent.
  4. Replace spark arrestor screens and retainer, and secure with clamp.

Valve Clearance
IMPORTANT NOTE: If uncomfortable about doing this procedure, or the correct tools are not available, take generator to the nearest service center to have valve clearance adjusted.
Inspect valve clearance after the first 50 hours of operation. Adjust as necessary.

  • Intake — 0.10 ± 0.02 mm (cold) (0.004 ± 0.001 in)
  • Exhaust — 0.10 ± 0.02 mm (cold) (0.004 ± 0.001 in)

Storage

General

DANGER : Explosion and Fire. Fuel and vapors ar e extremely flammable and explosive. Store fuel in a well ventilated area. Keep fire and spark away. Failure to do so will result in death or serious injury. (000143)

WARNING: Risk of Fire. Verify machine has correctly cooled before installing cover and storing machine. Hot surfaces could result in fire. (000109)

It is recommended to start and run the generator for 30 minutes every 30 days. If this is not possible, see the following list to prepare unit for storage.

  • DO NOT place a storage cover on a hot generator. Allow unit to cool to room temperature before storage.
  • DO NOT store fuel from one season to another unless correctly treated.
  • Replace fuel container if rust is present. Rust in fuel will cause fuel system problems.
  • Cover unit with a suitable protective, moisture resistant cover.
  • Store unit in a clean, dry area.
  • Always store generator and fuel away from heat and ignition sources.

Prepare Fuel System/Engine for Storage
WARNING: Vision Loss. Eye protection is require d to avoid spray from spark plug hole when cranking engine. Failure to do so could result in vision loss. (000181)

Fuel stored over 30 days can go bad and damage fuel system components. Keep fuel fresh, use fuel stabilizer.

fuel stabilizer is added to fuel system, prepare and run engine for long term storage. Run engine for 10–15 minutes to circulate stabilizer throughout fuel system. Adequately prepared fuel can be stored up to 24 months.

NOTE: If fuel has not been treated with fuel stabilizer, i t must be drained into an approved container. Run engine until it stops from lack of fuel. Use of fuel stabilizer in fuel storage container is recommended to keep fuel fresh.

  1. Change engine oil.
  2. Remove spark plug.
  3. Pour 1 tablespoon (5–10cc) of clean engine oil or spray a suitable fogging agent into cylinder.
  4. Pull starter recoil several times to distribute oil in cylinder.
  5. Install spark plug.
  6. Pull recoil slowly until resistance is felt. This will close valves so moisture cannot enter engine cylinder. Gently release recoil.

Change Oil
Change engine oil before storage. See Change Engine Oil.

Troubleshooting

PROBLEM CAUSE CORRECTION
Engine won’t start.
  1. Start Dial turned off.
  2. Out of fuel.
  3. Faulty spark plug.
  4. Plugged fuel filter.
  5. Faulty or stuck Start Dial assembly.
  6. Incorrect engine oil level.
  7. Faulty ignition coil.
  8. Carb is flooded.
  9. Throttle plate closed.

|

  1. Turn on Start Dial.
  2. Fill fuel tank.
  3. Replace spark plug.
  4. Replace fuel and fuel filter.
  5. Contact Customer Service at 1-888- 331-4569.
  6. Check/fill engine oil.
  7. Contact Customer Service at 1-888- 331-4569.
  8. Drain carb.
  9. Open throttle plate (push toward back of unit).

| |
Engine shuts down during operation.|

  1. Out of fuel.
  2. Incorrect engine oil level.
  3. Contaminated fuel.
  4. Faulty low oil level switch.
  5. CO Detection shutoff due to accumulating carbon monoxide if a RED light blinks on side panel badge.
  6. CO Detection shutoff due to system fault if YELLOW light blinks on side panel badge.

|

  1. Fill fuel tank.
  2. Check engine oil level.
  3. Contact Customer Service at 1-888- 331-4569.
  4. Contact Customer Service at 1-888- 331-4569.
  5. Follow all safety instructions and relocate generator to an open area out- side, far away from windows, doors, or vents.
  6. Start unit to confirm YELLOW light blinks when/if generator shuts off. If CO Detection continues to fault and shutoff, contact Customer Service.

| |
Engine starts and shuts down immediately.|

  1. CO Detection shutoff due to accumulating carbon monoxide if a RED light blinks on side panel badge.
  2. CO Detection shutoff due to system fault if YELLOW light blinks on side panel badge.
  3. Contaminated fuel.
  4. Faulty low oil level switch.

|

  1. Follow all safety instructions and relocate generator to an open area out- side, far away from windows, doors, or vents.
  2. Start unit to confirm YELLOW light blinks when/if generator shuts off. If CO Detection continues to fault and shutoff, contact Customer Service.
  3. Contact Customer Service at 1-888- 331-4569.
  4. Contact Customer Service at 1-888- 331-4569.

| |
Engine will not start; or starts and runs rough.*|

  1. Choke is stuck or left on.
  2. Dirty or clogged air filter.
  3. Faulty or dirty spark plug.
  4. Dirty fuel filter.
  5. Dirty or gummed up carburettor.
  6. Unit not warmed up.
  7. Spark arrestor clogged.

|

  1. Turn Start Dial to RUN.
  2. Clean or replace air filter.
  3. Replace spark plug.
  4. Replace fuel and fuel filter.
  5. Clean carburetor.
  6. Gradually adjust Start Dial until engine runs smoothly in RUN position.
  7. Clean spark arrestor.

| |
PROBLEM| CAUSE| CORRECTION
---|---|---
No AC output.|

  1. Generator is overloaded.
  2. Inverter module is overheated.
  3. Short circuit in electrical device.
  4. Faulty inverter assembly.

|

  1. Disconnect all loads. Shut down generator to reset module. Reduce loads, restart generator.
  2. Verify service door is ON. Let cool 15 minutes by running engine without AC output. Press and hold Reset but- ton on control panel, restart generator.
  3. Verify condition of extension cords and items being powered. Press and hold Reset button on control panel.
  4. Contact Customer Service at 1-888- 331-4569.

| |
Fuel leaks from drain hoses.| 1. Carburetor drain in bowl is not closed.| 1. Turn valve clockwise to close.

  • Engine speed increases and decreases — This is normal as generator starts up and loads vary.

    • Product Manufactured by: Generac Power Systems,
    • Inc. S45 W29290 Hwy. 59 Waukesha, WI 53189

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Craftsman User Manuals

Related Manuals