Please read the instructions carefully before commencing assembly
Live: Normally Brown / Red
Neutral: Normally Blue / Black
If the external cord of this luminaire is damaged, it must be replaced by the manufacturer or a qualified person.

| Not Suitable For Covering With Thermal Insulation.
---|---
| For Ceiling Use Only

CEILING TYPES

Ceiling lining secured directly to timber joists| Fire resistance periods to EN 1365-2: 2014 (mins)
---|---
Minimum 1 x 15 mm thick Type A or Type F gypsum wallboard to EN 520| 30 minutes
Minimum 2 x 12.5 mm thick Type F gypsum FireLine to EN 520| 60 minutes
Minimum 3 x 12.5 mm thick Type F gypsum FireLine to EN 520| 90 minutes

These products are suitable to install in fire protected timber floor and ceiling systems which have previously been successfully tested for at least 30 minutes, 60 minutes or 90 minutes to EN 1365-2 : 2014

JOIST TYPES

Solid softwood or hard wood timber joists manufactured from strength grade C16 or greater, installed at centres not exceeding 600 mm