MINIMA SLIMLINE AX5834 Round Fixed Fire-Rated IP65 Downlight in Matt Instruction Manual

June 6, 2024
MINIMA SLIMLINE

MINIMA SLIMLINE AX5834 Round Fixed Fire-Rated IP65 Downlight in Matt

MINIMA SLIMLINE FIRE-RATED

PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE COMMENCING ASSEMBLY

If the external cord of this luminaire is damaged, it must be replaced by the manufacturer or a qualified person.

NOT SUITABLE FOR COVERING WITH THERtv1AL INSULATION.

FOR CEILING USE ONLY

Glare guard

CEILING TYPES

Ceiling lining secured directly to timber joists|

Fire resistance periods to EN 1365-2: 2014 (mins)

---|---
Minimum 1 x 15 mm thick Type A or Type F gypsum wall board to EN 520|

30 minute

Minimum 2 x 12.5 mm thick Type F gypsum Fireline to EN 520|

60 minutes

Minimum 3 x 12.5 mm thick Type F gypsum Fireline to EN 520|

90 minutes

These products are suitable to insta ll in fire protected timber floor and ceiling systems wh ich have previously been successfu lly tested for at least 30 minutes, 60 minutes or 90 minutes to EN 1365-2 : 2014 /

JOIST TYPES

Solid softwood or hard wood timber joists manufactured from strength grade C16 or greater, insta ll ed at centres not exceeding 600 mm