Minima Slimline astro Round Fire Rated Dimmable Bathroom Downlight Instruction Manual
- July 19, 2024
- MINIMA SLIMLINE
Table of Contents
Minima Slimline astro Round Fire Rated Dimmable Bathroom Downlight
Instruction Manual
Please read the instructions carefully before commencing assembly
Live : Normally Brown / Red Neutral: Normally Blue / Black
If the external cord of this luminary is damaged, it must be replaced by the manufacturer or a qualified person.
Not Suitable For Covering With Thermal Insulation.
For Ceiling Use Only
Glare guard
CEILING TYPES
Ceiling lining secured directly to timber joists | Fire resistance periods to |
---|---|
Minimum 1 x 15 mm thick Type A or Type F gypsum wallboard to EN 520 | 30 |
minutes
Minimum 2 x 12.5 mm thick Type F gypsum Fire Line to EN 520| 60 minutes
Minimum 3 x 12.5 mm thick Type F gypsum Fire Line to EN 520| 90 minutes
These products are suitable to install in fire protected timber floor and ceiling systems which have previously been successfully tested for at least 30 minutes, 60 minutes or 90 minutes to EN 1365-2:2014/
JOIST TYPES
Solid softwood or hard wood timber joists manufactured from strength grade Cl
or greater, installed at centres not exceeding 600 mm/
-
Turn Off Power
-
down light per 0.72m²: 1 metre minimum spacing
Round Fixed, Round Adjustable & 25
Square Fixed & Square Adjustable