DELLTechnologies Unity XT Unified Hybrid Storage Arrays User Guide
- July 17, 2024
- DELLTechnologies
Table of Contents
- DELLTechnologies Unity XT Unified Hybrid Storage Arrays
- Product Information
- Product Usage Instructions
- FAQ
- Revision history
- Product Description
- Resolved issues
- Known issues
- 2 and is routed to the port group #1.
- Limitations
- Environment and system requirements
- Obtain and install product licenses
- Firmware
- Documentation
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DELLTechnologies Unity XT Unified Hybrid Storage Arrays
Product Information
Specifications
- Release Version: 5.4.0.0.5.094
- Release Type: Minor (MI)
- Targeted for: Midsized deployments, remote or branch offices, cost-sensitive mixed workloads
- Available in: All-Flash, hybrid Flash, converged deployment options
- Subscription Levels for Professional Edition: 10 TB, 25 TB, 50 TB, 350 TB
Product Usage Instructions
Unity Family Overview
The Dell Unity Family is designed for midsized deployments, remote or branch offices, and cost-sensitive mixed workloads. It comes in various deployment options and subscription levels.
Unity XT Platform
The Unity XT Series includes 8 hardware models with Hybrid Flash and All Flash configurations. It offers increased I/O performance, and storage efficiency features like Advanced Data Reduction, and supports a 25Gb interface card.
New Features
- 7.68TB SSDs and 15.36TB SSDs allowed in HFA systems
- Hardware-related OK messages are sent home for notifications and alerts
- Metadata space expands automatically and sends alerts regarding limits
- Password complexity requirements have been implemented for security
FAQ
Q: What is the Unity Family?
A: The Dell Unity Family is designed for midsized deployments, remote or branch offices, and cost-sensitive mixed workloads.
Q: What are the subscription levels for the Professional Edition?
A: The subscription levels include 10 TB, 25 TB, 50 TB, and 350 TB.
These release notes contain supplemental information about this Unity release.
- Current Release Version: 5.4.0.0.5.094
- Release Type: Minor (MI)
Revision history
This section provides a description of document changes.
Table 1. Revision history
Document revision | Date | Description |
---|---|---|
A00 A01 A02 A03 | February 2024 February 2024 March 2024 March 2024 |
Release 5.4.0.0.5.094 Adds additional information on new features Adds information on disabling the write cache feature Clarifies Unity APL expiration
Product Description
- Dell Unity is targeted for midsized deployments, remote or branch offices, and cost-sensitive mixed workloads.
- Unity systems are designed for all-Flash, deliver the best value in the market, and are available in purpose-built (all Flash or hybrid Flash), converged deployment options (through VxBlock), and a software-defined virtual edition.
The Dell Unity Family consists of:
- Unity (purpose built): A modern midrange storage solution, engineered from the ground up to meet market demands for Flash, affordability, and incredible simplicity.
- The Unity XT Family consists of 4 Hybrid Flash configurations (380/480/680/880) and 4 All Flash configurations (380F/480F/680F/880F) models.
- VxBlock (converged): Unity storage options are also available in Dell VxBlock System 1000.
- UnityVSA (virtual): The Unity Virtual Storage Appliance (VSA) allows the advanced unified storage and data management features of the Unity family to be easily deployed on VMware ESXi servers, for a ‘software-defined’ approach.
UnityVSA is available in two editions:
- Community Edition is a free downloadable 4 TB solution recommended for non-production use.
- Professional Edition is a licensed subscription-based offering available at capacity levels of 10 TB, 25 TB, 50 TB, and 350 TB.
- The subscription includes access to online support resources, EMC Secure Remote Services (ESRS), and on-call software- and systems-related support.
- All three Unity, UnityVSA, and Unity-based VxBlock deployment options enjoy one architecture, one interface with consistent features and rich data services.
Unity is Redefining Storage Simplicity and Value
- Here are some of the features and supporting statements that allow Unity to redefine midrange storage.
- Simple: Simplified ordering, all-inclusive software, rack-and-stack in less than 2 minutes, customer installable, a new slick HTML5 user interface, proactive assist, and CloudIQ internet-enabled monitoring.
- Modern: Unity is designed to support the latest dense Flash drives such as 3D TLC NAND with a Linux-based architecture, new Intel Haswell, Broadwell, and Skylake multicore processors, up to 440K IOPS, 2U dense configurations, scalable 64bit file system & file system shrink, unified snapshots & replication, Data-at-Rest-Encryption (D@RE), support for public and private cloud access, deep ecosystem integration with VMware (native vVols) and Microsoft, and much more.
- Affordable: Unity delivers the best midrange Flash economics with a great entry price and overall TCO. Unity All Flash configurations start under $15K and Unity Hybrid Flash configurations start under $10K. UnityVSA allows anyone to get started for free and upgrade into the supported virtual edition, a purpose-built hybrid or all-Flash system, or into a converged infrastructure.
- Flexible: You can meet any storage deployment requirement with Unity from virtual to purpose-built to converged infrastructure. All deployment options support the same data unified data services (SAN/NAS and vVols) to support any workload with traditional files (file consolidation, VDI user data, home directories) as well as transactional workloads for both file and block on all Flash and hybrid configurations (Oracle, Exchange, SQL Server, SharePoint, SAP, VMware, and Microsoft Hyper-V).
Unity XT Platform (380/F, 480/F, 680/F, 880/F series)
- The Unity Next Generation Platform refresh, also known as the Unity XT Series, consists of 8 hardware models, including 4 Hybrid Flash and 4 All Flash configurations—the Dell Unity 380, 380F, 480, 480F, 680, 680F, 880, and 880F. The XT series increases the performance of I/O, maximizes storage efficiency features like Advanced Data Reduction with inline deduplication, and supports a 25Gb interface card.
- The Unity 380(F) is based on the existing platform today for the 350F model but with additional memory (64 GB per SP).
- The Unity 480/F, 680/F, and 880/F are built on an Intel Skylake platform. For more information, see the Unity 380/F, 480/F, 680/F, and 880/F Hardware Information Guide.
- The Unity XT series supports Advanced Data Reduction in both dynamic and traditional pools in All Flash (F) models and All Flash pools in Hybrid models.
- Unity software OE version 5. x and later supports the new x80 series models, in addition to all existing x00 and x50 series models.
- Note: The Unity XT 480/F, 680/F, and 880/F are available for both high-line (200v-240v) and low-line (100v-120v) power environments, but you must select the appropriate option when ordering your system.
- Low-line is used in select countries that supply 100-120V, typically through a wall outlet, while high-line is used in environments that supply 200-240V.
- Country-specific cables are available for plugging a Unity system directly into a wall outlet that either supplies 100-120V or 200-240V. If supplying 100-120V to a Unity XT 880/F, a step-up transformer is required.
New features
Functional area | Feature description | Summary of benefits |
---|---|---|
Hardware | 7.68TB SSDs and 15.36TB SSDs are |
allowed in HFA systems
| 7.68TB and 15.36TB 1WPD SSDs can be used in Hybrid Flash Array (HFA) systems
and hybrid pools. Using these SSDs decreases the cost per GB, allows larger
pool capacity, and provides more flash tier space for data.
Notifications and Alerts| Hardware-related OK messages are sent home| Allows
all hardware-related informational OK messages to be sent home. If a hardware
issue initially connects home with an error alert and then the fault clears,
these systems generate a second connection message stating the hardware is OK.
This feature supports the following hardware types:
· Disk Processor Enclosure (DPE) including battery, cooling module (fan), memory, power supply, and drives.
· Storage Processor (SP), including SLICs (I/O modules), Ethernet, FC and SAS ports, and System Status Card (SSC).
· Disk Array Enclosure (DAE), including LCC (Link Control Cards), and
power supplies.
Notifications and Alerts| Metadata space expands automatically and sends
alerts regarding limits| Automatically balances the metadata space and the
storage space with every incoming write. This allows full capacity utilization
and avoids performance issues.
Notifications and alerts| An alert has been provided through Unisphere so that
a user can identify an issue with blocked threads| Allows you to identify an
issue with blocked threads that would impact performance on the array. This
gives you time to identify and correct the issue before the impact of blocked
threads to system operation grows.
Security| A new password complexity requirement has been implemented| Password
length for Unisphere users has been increased to support a 64- 64-character
length alphanumeric in compliance with the latest US federal requirement OMB
M-22-09. The password requirement is:
· 8 to 64 characters in length
· Contains at least one upper-case letter
· Contains at least one lowercase letter
· Contains at least one numeric
Special characters are not required in the password.
Security| Unity APL expiration| Unity APL expires in March 2024.
Functional area| Feature description| Summary of benefits
---|---|---
Security| Disable SMB2 at the NAS server level| This option enables you to
disable SMB2 at the NAS level by using the svc_nas service command. This
protects your system from known vulnerabilities associated with the SMB2
protocol.
Serviceability| Write cache is automatically disabled| Unity systems
automatically disable write cache whenever an SP enters service mode to
prevent potential cache loss.
Serviceability| The RSC (Remote Secure Credentials) option in Unisphere does
not appear when remote connectivity and RSC is already enabled| Users cannot
disable the RSC option in Unisphere once remote connectivity and RSC have been
enabled.
Serviceability| Enable user-selected file transfer using the Managed File
Transfer (MFT) transport channel| A new option is provided to transfer user-
selected files back to Dell using the Managed File Transfer (MFT) transport
channel, which is one of the SupportAssist (on physical Unity) or ESRS (on
UnityVSA) functionalities. Users can directly send the specified file, either
a service Information file or core dump, back to Dell if SupportAssist or
ESRS, whichever is applicable, is enabled. This will improve support
efficiency.
Serviceability| A critical alert is provided that directs users to change the
sender email address from a Unity system to match that of the user’s company
email domain| Helps ensure that users update the sender email address to their
company domain so that the user receives Dell support and Dell receives the
user’s data properly.
Storage – File| Restrict SMB exports| You can configure host access to SMB
shares, setting access to either Read/Write to allow the host to access the
share or No Access to prevent a host from accessing an SMB share.
System Management| Set the NTP stratum higher| The NTP orphan rank can be set
to the highest support stratum, allowing you to set the stratum without
service intervention.
System Management| Quickly restart Doctor and Apache| New service command
options enable you to restart uDoctor and Apache without root access.
Unisphere CLI| Adds and remote hosts| Using the command line interface, you
can add hosts and remove hosts from LUNs, LUN groups, VMFS datastores, vVols,
and file systems.
Unisphere UI| Sort data stores by the SP owner| Enables you to see a list of
SP owners on the DataStores tab. You can also sort data stores and other
VMware resources by clicking the SP Owner column.
Changed features
Functional area | Feature description | Summary of benefits |
---|---|---|
Hardware | New support for drive firmware | Drive firmware version 21 is |
included in the 5.4 software OE bundle and can be installed at the end of the Software Upgrade wizard. For more information on the impacted drives and models for this firmware, see Knowledgebase article 000021322.
Resolved issues
This table lists the issues fixed in this release. For all issues fixed in previous releases, refer to the release notes for that specific Unity OE.
Table 2. Resolved issues in the product version
Issue ID | Functional area | Description |
---|---|---|
UNITYD- 69519/UNITYD-69152 | Common Event Enabler | The Unity system cannot |
connect to a CEPA server using the Microsoft RPC protocol.
UNITYD- 69517/UNITYD-65128| Connectivity – Hosts| A rare internal timing
condition results in an unexpected SP reboot.
UNITYD- 66961/UNITYD-66270| Connectivity – Hosts| In rare cases, a single SP
might reboot when more than 2,000 LUNs or snapshots are attached to or
detached from a large number of ESXi hosts in a short period.
UNITED-61047/60145| Connectivity – Networks| An SP may unexpectedly reboot if
you use the tool “hostconfcli” to display some configurations.
UNITYD- 60971/UNITYD-60790| Connectivity – Networks| If a NAS server is
configured to reflect IP packets and you mount an NFSv3 share using the User
Datagram Protocol (UDP), read requests larger than the MTU get no response.
UNITYD- 68810/UNITYD-64088| Data mobility| If a snapshot is created on the
destination side during a NAS sync replication session, it is periodically
refreshed to get the NAS configuration from the source side. When the snapshot
is refreshed, the system creates a new snapshot and mounts it before removing
the old one. The old snapshot is not deleted when mounting the new snapshot
fails.
UNITYD- 66236/UNITYD-64703| Data mobility| If the management network
communication is unstable, remote replication host “communication lost” alerts
are reported intermittently.
UNITYD- 62740/UNITYD-59364| Data mobility| After an SP reboots unexpectedly,
sync replication sessions might take a few hours to return to a consistent
status.
UNITYD- 62194/UNITYD-61679| Data mobility| UEMCLI shows duplicated replication
sessions when the configuration of the remote replication interface changes.
UNITYD- 61433/UNITYD-60856| Data mobility| When the configured bandwidth
increased, a small delay in replication between the time when a transfer
should have started and when the transfer began was noticed in the Unisphere
Performance Dashboard.
UNITYD- 60997/UNITYD-60573| Data mobility| A replication session remained
syncing when an offline user snapshot was found and did not transfer data for
that offline snapshot.
UNITYD- 60695/UNITYD-58578| Data protection| An SP sometimes reboots when
unmounting a read-only snapshot.
UNITYD- 61572/UNITYD-62741| Import| In rare situations during IMT cutover, the
IMT session can hang
UNITED-61977| Import| Unity’s capacity is calculated in TiB/GiB/MiB/KiB
(Base-2) but displayed as TB/GB/MB/KB (Base-10) in Unisphere.
UNITYD- 61944/UNITYD-61391| Import| A filename containing emoji characters can
result in an IMT import session failing to import data during the incremental
copy.
UNITYD- 61600/UNITYD-60469| Import| If the internal IP address of the SP is
used to create a FileService interface or a NetworkService interface, the SP
may reboot.
UNITED-69652| Other| The severity of the alert for receiving the uDoctor
package is Info when it should Warning.
Issue ID| Functional area| Description
---|---|---
UNITED-67797| Other| Some call home alerts might not be sent if too many call
home alerts are reported at the same time.
UNITYD-61171/UNITYD- 60684| Other| The customized banner does not display at
the UEMCLI login after OE upgrades but does display in Unisphere.
UNITYD- 60993/UNITYD-59265| Other| A storage processor reboot can occur when
there are several failed data uploads.
UNITYD- 70502/UNITYD-69003| Security| A problem with either the network or the
KDC server may cause an SP to reboot if Kerberos is used to change a NAS
server password.
UNITYD- 61483/UNITYD-61061| Security| When STIG and user account settings are
enabled, the NMI button reset of the admin password fails.
UNITYD- 61682/UNITYD-58860| Serviceability| A replication session cannot be
resumed when session issues cause inconsistent size settings in the internal
components of the destination system.
UNITYD- 63537/UNITYD-62954| Software installation and upgrade| After a non-
disruptive upgrade to Unity OE version 5.3, a single SP might reboot due to an
internal data-persistence synchronization issue.
UNITYD- 70988/UNITYD-70580| Storage – Block| The Data Relocated value that is
shown after you run the UEMCLI faster show command is not accurate if there is
data imbalance within a RAID Group.
UNITYD- 70256/UNITYD-68546| Storage – Block| An internal operation is handled
incorrectly, resulting in a single SP reboot.
UNITYD- 63651/UNITYD-62768| Storage – Block| After an SP unexpectedly shuts
down or reboots, it might take a long time (more than 15 minutes) to fail the
VDM over to the peer SP.
UNITYD- 62608/UNITYD-59918| Storage – Block| In rare instances, a storage
processor may reboot unexpectedly when RecoverPoint is in use. In some cases,
RecoverPoint services are not restarted on the SP.
UNITYD- 62310/UNITYD-61537| Storage – Block| When an SP reboots before a RAID
5 RAID Group rebuild finishes and another disk fails during the SP reboot it
results in the RAID Group in failure due to a double fault, the related LUN
results in trace log flooding, which may lead to an SP boot-up failure.
UNITYD- 72454/UNITYD-68037| Storage – File| If you are running Unity OE
versions 5.2.x or 5.3.x and many user quotas are configured, an unexpected SP
reboot might occur after the system has been running for a long time.
UNITYD-71876/UNITYD- 61070| Storage – File| If you migrate data between two
file systems using the host tool, or if the file systems are experiencing high
I/O, the file systems might go offline.
UNITYD- 70592/UNITYD-69893| Storage – File| Incorrect memory handling can
result in an SP reboot when setting up LDAP services.
UNITED-70557| Storage – File| You cannot enable a quota on a filesystem if the
root directory currently has alternate data streams (ADS). If you find files
with filenames that are prefixed with “:” in the root directory by running
command “dir /r”, the root directory has ADS.
UNITYD- 69076/UNITYD-68948| Storage – File| The storage system might reboot
during a filesystem remap operation.
UNITYD- 68729/UNITYD-68330| Storage – File| A virus checker resource leak
causes a file system to go offline.
UNITYD- 66160/UNITYD-63136| Storage – File| Although setting up a multichannel
with a fail-safe networking (FSN) device succeeds, multichannel does not work.
UNITYD- 64832/UNITYD-64457| Storage – File| If CIFS Kerberos is configured, an
SP might reboot unexpectedly when a client sends an invalid request.
Issue ID| Functional area| Description
---|---|---
UNITYD- 63767/UNITYD-61973| Storage – File| When a VDM has both LDAP and
Kerberos configured, an SP reboot might occur if the LDAP reports too many
errors persistently.
UNITYD- 62905/UNITYD-62382| Storage – File| An NFSv4.1 client might hang and
have trouble accessing the NFS server.
UNITYD- 62581/UNITYD-62046| Storage – File| An SP might reboot unexpectedly if
a client sends a large number of SMB2 connecting requests to the Unity system.
The connecting request limit for an SMB session is 64,770.
UNITYD- 62449/UNITYD-61876| Storage – File| When enabling NFS extended UNIX
credential and NFSv4 delegation, you might sometimes encounter a permission
issue while accessing files.
UNITYD- 62321/UNITYD-61127| Storage – File| The SMB client cannot set file
information with its named stream file.
UNITYD- 62168/UNITYD-62017| Storage – File| An SP reboot occurs during an
internal SMB processing operation.
UNITYD- 61949/UNITYD-61521| Storage – File| If you are running OE version 5. x
and use third-party middleware to create a file or directory whose name length
exceeds 256 bytes, the SP might unexpectedly reboot due to lack of memory.
UNITYD- 61748/UNITYD-61592| Storage – File| A file system recovery cannot be
completed sometimes.
UNITYD- 61660/UNITYD-61559| Storage – File| For the command “svc_nas -param -f
nfs -I transChecksum -v”, the output shows “user_action = restart NAS Server”.
However, the SP must be rebooted to make the change work.
UNITYD-61613/UNITYD- 61400| Storage – File| Unity sometimes reboots
unexpectedly when the connection to the LDAP server is not stable.
UNITYD- 61560/UNITYD-61139| Storage – File| The SP might reboot when there are
errors with the LDAP servers configured in the NAS server.
UNITYD- 61503/UNITYD-60936| Storage – File| File systems sometimes go offline
when they are almost full, and users are creating new files.
UNITYD-61482/ UNITYD-61156| Storage – File| You cannot mount an NFS export on
the client.
UNITYD- 65247/UNITYD-64882| Unisphere CLI (UEMCLI)| Some UEMCLI commands fail
if the password contains a colon (:) character.
UNITED-67036| Unisphere UI| After you change a password using the Unisphere
preference menu, you are logged out and must log in again to continue.
UNITYD- 62166/UNITYD-61820| Unisphere UI| Sometimes you cannot add an NTP
server when the server has a limit on the client request rate.
UNITYD- 61984/UNITYD-61671| Unisphere UI| If you sort a few columns, for
example [used (%), Allocation (%)], and then hide those columns and export
them, the export screen does not show an error, but the data is not exported.
UNITED-61978| Unisphere UI| The Online Help shows TB instead of TiB.
UNITYD- 61330/UNITYD-60158| Unisphere UI| Sometimes when creating a
traditional pool fails, the returned error message is misleading.
UNITYD- 59977/UNITYD-59328| Unisphere UI| To make the csv export functionality
more secure, if these strings [,@], [,=], [,+], [,-], [,”@], [,”=], [,”+],
[,”-] (not including []) are found in the csv cell value, ‘ (single
apostrophe) will be prepended to characters @ = + -. They are changed to
[,’@], [,’=], [,’+], [,’-], [,”‘@], [,”‘=], [,”‘+], [,”‘-].
Issue ID| Functional area| Description
---|---|---
UNITYD-61514/UNITYD- 60783| Virtualization| Sometimes the VVOL page (STORAGE
->VMware ->Virtual Volumes) in Unisphere cannot be loaded normally.
UNITYD- 61638/UNITYD-62580| Need functional area| An SP might reboot
when parsing a deleted local user in the mapping service.
Known issues
Table 3. Known issues in the product version
Issue ID | Functional area | Description | Workaround/Solution |
---|---|---|---|
869166 | Common Event Enabler | When a host is configured to use CAVA for the |
CEPA server, there is a host IO error on the SMB protocol with the following message in the logs:
“Too much access from CAVA server xx.xx.xx.xx without the EMC VirusChecking privilege:>>> User credential (xx.xx.xx.xx address of the host).”
| Do not use CAVA/CEPA NAS servers for regular host IO.
UNITYD-50686| Connectivity – Hosts| LED light may not be On when inserting
either a 32G or 16G SFP into a 4-port 32Gb Fibre Channel I/O module slot.|
Remove and reinsert the SFP card.
UNITYD-60790| Connectivity – Networks| After you mount an NFSv3 share using
the User Datagram Protocol (UDP) to the NAS server, which is enabled to
reflect IP packets, large IO read requests (larger than the MTU) get no
response.| There are two workarounds that you can use:
1. Mount an NFSv3 file system (FS) share using TCP.
2. Mount an NFSv3 FS share using UDP, but disable the IP reflect packet feature.
UNITYD-42194| Connectivity – Networks| In rare cases, if a link aggregation or
fail-safe network (FSN) link is composed of two or more ports on a 4-port
1-GbE BaseT I/O module, changing the MTU speed for the link aggregation or FSN
may cause an SP reboot.| First, modify the MTU speeds of the ports on the
4-port 1-GbE BaseT I/O module to the expected values. Then, modify the MTU
speed of the link aggregation or FSN.
932347/ UNITYD-5837| Connectivity – Networks| Immediately upon creation, the
Fail-Safe Network (FSN) appears in a “Link Down” state. An alert similar to
the following is displayed.
“System XXX has experienced one or more problems that have had a minor impact”
With a detailed description of
“The system has experienced one or more minor failures. Check related alerts and fix the underlying problems.”
| If all Ethernet ports participating in this FSN port, either directly or
using Link Aggregation, are connected properly, the FSN port will
automatically recover from the “Link Down” state within 30 seconds or less. It
is also possible that FSN port recovery goes through a “Degraded” state, for
approximately 60 seconds after the FSN creation. This alert can be ignored
unless the FSN port fails to enter the “Link Up” and “Health OK” state
approximately 60 seconds after creation.
UNITYD- 62009/UNITYD- 61636| Data mobility| A local consistency group
replication session LUN member pairing is mismatched when the session is
created from the GUI.| Use the “-elementPairs” option in the Unisphere UEMCLI
to create a local async CG replication session after
Issue ID| Functional area| Description| Workaround/Solution
---|---|---|---
| | | provisioning the destination consistency group.
UNITYD-54629| Data mobility| Only the SMB1 protocol is supported for a Unified
VNX (VNX1 or VNX2) storage system as the source storage system in a VDM file
migration.| If either the SMB2 or SMB3 protocol is used on the VNX source
system, the protocol must be changed to SMB1 before performing the migration.
UNITYD-54862| Data mobility| If you use an atypical advanced replication
configuration, such as using asynchronous replication inbound and synchronous
replication outbound, the synchronous replication destination NAS server
sometimes becomes faulted during a planned failover of asynchronous
replication.| Before performing the planned failover asynchronous replication
session, pause the synchronous replication session first. After the planned
failover asynchronous replication session is completed, resume the synchronous
replication session.
UNITYD-51634| Data mobility| In MetroSync when the MetroSync Manager is
configured, if the MetroSync Manager detects that the source pool is offline,
it initiates an unplanned failover. Even if the unplanned failover succeeds,
the source site may not be cleaned up correctly, and the subsequent failback
may fail.| Delete the synchronous session and recreate it but note that a full
synchronization will occur.
UNITYD-51288| Data mobility| When deleting a synchronous replication of a NAS
server, if the peer SP is rebooting gracefully, the delete operation may
fail.| Retry to delete the synchronous replication operation.
943734/ UNITYD-4469| Data mobility| The “Last sync time” of a replication
session is updated, but the “transfer remaining size” is not zero.| Wait about
2 minutes, then view the replication session details again.
906249/ UNITYD-2788| Data mobility| A request to create a replication session
for VMware NFS datastore which resides in a multiprotocol NAS server will fail
until the first synchronization of the associated NAS server replication
session.| Synchronize the NAS server replication session at least once before
creating a replication session for a VMware NFS datastore residing on the
multiprotocol NAS server.
UNITYD-45110| Data protection| When the system is configured with a large
number of replications (over 1000) and both SPs are rebooted simultaneously,
one storage processor may experience an additional reboot after the system
comes back up.| No manual operation is needed.
The system will automatically recover after the reboot.
UNITYD-36280| Data protection| The snapshot schedule function failed to create
a scheduled snapshot of a synchronous replication-protected file system during
the session failback operation.| None.
UNITYD-31870| Data protection| The snapshot schedule timer reset (restarted
from 0) after the Unity management service was rebooted, or a new resource was
assigned to it. This leads to this schedule being applied to existing
resources.| None.
981344/ UNITYD-6289| Data protection| There are three Arrays: A, B, and C. The
following scenario occurs:
1. Site A set up synchronous replication sessions.
| 1. To prevent this issue, wait two minutes after the failover, then run the preserve operation.
2. If this issue occurs, rerun the preserve operation.
Issue ID | Functional area | Description | Workaround/Solution |
---|---|---|---|
2. Site A-C set up asynchronous replication sessions. |
3. Shut down site A and do a cabinet failover on B.
4. Preserve all asynchronous replication sessions immediately on B.
Some asynchronous replication sessions are not preserved. (No Error message in Site B. The asynchronous replication sessions which are not preserved will be “Lost Communication” in Site C.)
|
949119/ UNITYD-
4769/ UNITYD-
5112
| Data protection| If an NDMP restore restores a file that exceeds a quota
hard limit, the file will be restored as owned by the root user.| The
administrator should manually increase the quota limitation for the user and
correct the file ownership.
821501| Data protection| When a user runs a token-based incremental backup
using Networker, a full backup is performed instead.| Add ATTEMPT_TBB=Y to
Application Information while configuring the NDMP client, or change the value
in the NDMP client properties.
875485| Data protection| The following error could be returned when multiple
snap diff REST API requests were sent in parallel.
“‘{ “error”: { “created”:
“2016-12-05T17:34:36.533Z”,
“errorCode”: 131149826,
“HTTP status code”: 503, “messages”:
[ { “en-US”: “The system is busy. Try again later. If the problem persists, search for the error code on the support website or product forums, or contact your service provider, if available. (Error Code:
0x7d13002)” } ] } }”
| Reduce the number of parallel operations and try again.
917298| Data protection| NAS_A or NAS_B and related user VDMs failed to
recover due to an error occurring in the system VDM NAS_A or NAS_B, as seen in
the Unisphere CLI or UI.
After following the recommended resolution steps in the health details, the NAS servers are recovered and go into a ready state.
However, the replication sessions on these system VDMs and related user VDMs will no longer be visible.
| After recovery, reboot the primary SP. After the SP reboot, system NAS
servers will be recovered successfully, allowing replication sessions to be
recovered.
17379| Hardware| In some Unity XT 480/F, 680/F, and 880/F model DPEs, the Non-
maskable Interrupt (NMI) (hard reset) button is misaligned.| Press the NMI
button at an angle.
UNITYD-31523| Import| When using a “UNIX” access policy, if a domain user
belongs to the “domain admin” or the “administrators” group, files created by
the user will use “administrators” as owner, which is expected behavior for
Windows.
If using an NFS client to list these files, the file owner is the user.|
Change the owner to the correct user.
Issue ID| Functional area| Description| Workaround/Solution
---|---|---|---
| | After migration, the owner of the files from the CIFS client will be the
“administrator”, and the owner of files from the NFS client will be
“2151678452”. This may cause some files created by the CIFS client before the
migration cutover to be inaccessible by the NFS client after the migration
cutover.|
938977/ UNITYD-4327| Import| When creating a remote system for file import,
when the SANCopy connection is created and the remote system is verified
before starting a block import, the SANCopy host is not created, so the user
cannot create a block import session.| Delete and recreate the remote system.
After re-creating the remote system, the SANCopy host can be created
successfully.
969495| Import| If a pool out-of-space event occurs on a destination Unity
array after a file migration session cutover from VNX to Unity, some folders
and files may be lost on the Unity array. Although the migration session can
resume and be completed after expanding the destination pool, no warning or
error message will occur mentioning that data may be missing.| 1.
Always plan to have enough space on the destination pool before starting a
migration. Extra buffer space may be needed if there might be continuous large
I/O during the migration.
2. If a pool out-of-space event does occur after cutover, cancel the migration session, and start again by creating a new session.
UNITYD-65663| Notifications and alerts| If you upgrade from Unity OE version
4.3 or earlier to version 4.4, the reboot alert 301:30000 uses a lower-case
parameter (spa/spb), and the reboot finish alert 301:30001 uses an upper-case
parameter (SPA/SPB). This leads to parameter mismatch, and the 301:30000 alert
is not deactivated automatically.| Ignore the 301:30000 alert.
952772/ UNITYD-5971| Notifications and alerts| A misleading alert
“Unable to detect Ethernet port or link aggregation for the network interface N/A configured on NAS server %1.”
displays during NAS server deletion, even though it completes successfully.
| Ignore the erroneous alert.
999112| Notifications and alerts| The health description for the Ethernet port
is incorrect; it shows that this port was not in use, but in fact, it was used
for some file interfaces.| Bring up the ethernet port and then the health
status and description will be updated.
UNITYD-71322| Other| After a primary storage process re-image operation, the
UDoctor package fails to install at the selected time.| Manually delete all
files under
/opt/UDoctor/udoctor_packa ge/unhandled and restart the management server.
UNITYD-71940/ UNITYD-66425| Security| After enabling KMIP, if you upgrade to a
later release, disable KMIP, and then try to load the certificates, you see a
“failure to upload the client certificate” error.| Run the service command
svc_restart_service restart MGMT.
UNITYD- 71262/UNITYD-
71259
| Serviceability| When using Config Capture, you might see more than one value
for a RESTful class in the restMetrics table of the Config Capture results as
well as duplicated primary key errors for the restMetrics object.| Ignore the
data and errors in the restMetrics table of the Config Capture result and
initiate another Config Capture.
Issue ID| Functional area| Description| Workaround/Solution
---|---|---|---
908930| Storage – Block| Even when snap auto delete is disabled on the storage
pool, the storage pool may still show a degraded state indicating it could not
reach the low water mark.| Use the CLI to increase the pool space’s low water
mark to bring the pool back to a normal state. For example:
email -u xxx -p xxx / stor/config/pool –id pool_97 set – snapPoolFullLWM 40
UNITYD-72579| Storage – File| Typically, when you perform a planned failover
for a VDM synchronous session, the filesystem that belongs to the VDM also
fails over. Sometimes, however, some filesystems cannot failover with the VDM
sync session. In this situation, the filesystem synchronous session and the
VDM synchronous session direction are not the same. After that, if you perform
a planned failover again on the VDM synchronous session, the filesystem whose
direction is not the same as the VDM synchronous session cannot expand in
size.| 1. Use the MluCli command “MluCli.exe ufsspacemgmtcontrol – srvc_cmd
-ufsid
2. Perform another VDM failover to activate the filesystem expansion.
128333021/ UNITYD-52094/ UNITYD-53457| Storage – File| After upgrading to
Unity OE version 5.1.x, the audit log path and size are reset to the
defaults.| Change the “cifs userDefinedLogFiles” parameter to 0 and restart
the VDM. Refer to Knowledge Base article 000193985 for more information.
UNITYD-51284| Storage – File| When creating many asynchronous replication
sessions concurrently by using automatic scripts, the sessions may partially
fail.| Delete any failed replication sessions from the destination system, and
reconfigure them one at a time.
119078191 / UNITYD-48904/ UNITYD-53251| Storage – File| When adding a new
interface to a NAS server, if the preferred interface has an “auto” setting,
the preferred interface is not switched to the newly added one if it has the
same gateway availability and number of routes as the currently active
preferred interface.| Either make a specific interface to be the preferred
interface or make sure the DNS servers added with the new interface are active
before adding it.
20199488/ UNITYD-45132/ UNITYD-53297| Storage – File| During specific
circumstances when a file system becomes full and is made Read-Only, the file
cannot be deleted as expected.
However, the return code from the Unity system does not adhere to the RFC. There is no loss of functionality.
| None.
855767/ UNITYD-1261| Storage – File| When you customize a list of CIFS Shares
Access Control Entries (ACEs) by either making a REST API call, editing the
share permission using the Windows MMC console, or using the SMI-S API,
isACEEnabled might erroneously indicate false.| Ignore the value
isACEEnabled=false in this case. When ACEs are properly set, they are always
enabled, despite this value in the REST API attribute. A REST API request for
a list of ACEs will return the correct list of custom ACEs for the share, and
those ACEs will all apply.
Alternatively, force a reload of the management model for the share by changing the share description, or for the whole system by restarting the management software.
Issue ID | Functional area | Description | Workaround/Solution |
---|---|---|---|
942923/ UNITYD-7663 | Storage – File | If you have set different user quotas on |
a non-multiprotocol SMB file system that you are changing to a multiprotocol
file system, the Remapping File Owner process will not preserve the specific
user quotas you had set previously. If the user quotas are all the same or
(have default values), this issue does not occur.| After remapping users to
their Unix user counterparts, re-issue the specific User Quota settings.
959208/ UNITYD-5257| Storage – File| If an LDAP user is configured before
Directory Services (LDAP) is configured, and a local user account with the
same name exists, the array will report that the LDAP user already exists,
instead of ‘not found in the LDAP database’.| Configure LDAP and reboot the SP
Then, add the LDAP user (role) again. This will be allowed even if a local
user with the same account name exists.
974999| Storage – File| When opening or deleting a locked file from an FLR-
enabled file system on a Windows client, sometimes there are several
additional log events generated in the FLR activity log.| This issue will not
happen on the NFS client, it just generates some additional log events, which
can be seen by the administrator. Ignore these log events.
975192| Storage – File| When automatic file locking is enabled on an FLR-
enabled file system, a file on an SMB share can be locked automatically.
However, the file mode property might not be updated and will not indicate the
file is read-only even though it is protected.| Use the FLR Toolkit to
determine whether the file is automatically locked instead of the SMB client.
UNITYD-60279| SupportAssist| When upgrading from old releases to Unity OE
version 5.3, the automatic conversion from integrated ESRS with proxy to the
latest SupportAssist will fail if the Unity system is in a private LAN. In
this configuration, Unity has no direct network connection to Dell backend
services (esrs3- core.emc.com). There is a post-upgrade alert, 14:38004b
(Migration from Integrated ESRS to SupportAssist failed. Configure
SupportAssist manually.)| No workaround. SupportAssist needs to be configured
manually to restore the connection to Dell backend services.
UNITYD-58751| SupportAssist| If SupportAssist is disabled when there is an
active remote session in progress, the active remote session may remain
active.| Contact your service provider to close the active session.
UNITYD-52201| System management| When trying to create or expand a traditional
pool with the following conditions, the listed drive count available for a
tier might be 0 due to an internal timeout error (>10mins):
1. RAID5 with maximum capacity option.
2. The disk group for this tier has 500+ free drives.
| Use one of the following options to fix the issue:
· Use the CLI to expand the pool.
· Use either Unisphere or the CLI to create a dynamic pool that contains some of the drives in the large disk group, reducing the free drive count in the disk group to less than 500. Then
Issue ID | Functional area | Description | Workaround/Solution |
---|---|---|---|
use Unisphere to expand the original traditional pool. | |||
896002 | System management | If a Unity system uses NTP for synchronization, |
when the time is adjusted to an earlier time from the current time, real-time
system metrics do not appear, and the system generates “Query ID not found
(0x7d1400c)” errors.| In Unisphere, navigate to another page and then return
to the metrics page, or log out of Unisphere and log in again.
973979| System management| When you create a file system named \”\’, the SMB
share page in the GUI does not display the proper description for the shares
associated with the file system named \”\’ and the UEMCLI does not display the
proper values for the shares associated with file system named \”\’.| Do not
name file system \”\”.
998582/ UNITYD-7835| Unisphere UI| When there are many storage resources
configured on the array, (for example, 6000 LUNs and 2000 file systems),
filtering the LUNs using a keyword for the LUN name in the Unisphere UI may
take over five minutes, and then show an error message if there are multiple
matches (1500+ matches).| Reload the Unisphere UI, then choose a more specific
keyword that matches fewer LUNs, or do not use keyword filters on large
configurations.
921511/ UNITYD-3397| Unisphere UI| Unisphere returns the following message:
“Your security session has expired. You will be redirected to the login
page.”| Confirm that the Unisphere login account in use is still active and
has Storage Admin privileges. Be sure to close the active browser session
before logging in with another account.
946287/ UNITYD-4572| Unisphere UI| When logging into Unisphere as one user and
then trying to log in as another user without restarting the browser, some
login information is cached by the browser and this will fail.| Restart the
browser to log in successfully.
968227/ UNITYD-5636| Unisphere UI| In rare circumstances, when a user creates
a snapshot by using the Unisphere UI, an unexpected error may occur. However,
the actual snapshot creation was completed successfully. The newly created
snapshot will display immediately.
The unexpected error occurs because the REST API failed to fetch the snapshot ID.
| Ignore the error if the newly created snapshot appears.
849914| Unisphere UI| The Job Details page in Unisphere does not display the
name of a LUN group after it failed to be deleted.| There is no workaround for
this issue.
907158| Unisphere UI| After upgrading from a system running Unity OE 4.0 or
4.1, the Unisphere UI did not allow the NAS server SP owner to be changed|
Clear browser cookies and refresh Unisphere.
995936 UNITYD-7474| Unisphere UI| Incorrect drive health information may be
displayed in the Unisphere UI if switching an SAS cable from an onboard SAS
port to a backend SLIC port. FBE shows these drives as “OK” while Unisphere
shows these drives as faulted.
For example, if switching the SAS cable from SAS port 0 to backend SLIC port 0, then
| 1. Identify the primary SP in Unisphere under Service à Service tasks.
2. Reboot the primary SP using the “svc_shutdown -r” service command.
Issue ID | Functional area | Description | Workaround/Solution |
---|---|---|---|
DAE 0_0 becomes DAE 2_0, and the related disks change from Disk 0_0_X to | |||
Disk 2_0_X. Unisphere will display these drives as faulted. | |||
895052 | UnityVSA | SSH is disabled after a single Processor UnityVSA upgrade. |
After performing a Unity OE upgrade, re-enable SSH using Unisphere or the Unisphere service command “svc_ssh
-e”.
945773| UnityVSA| The following error displays on the UnityVSA:
**** Error: <CPU of the physical server hosting UnityVSA does not meet the CPU instruction set minimum requirement (SSE4.2 or greater) for upgrading to this release or later.> Action: Migrate the UnityVSA to a server with a CPU that supports SSE4.2 or greater, or deploy a new UnityVSA on a CPU that supports SSE4.2 or greater. Then retry the upgrade.”
| When upgrading the UnityVSA to Unity 4.3 or deploying a new 4.3 UnityVSA on an older server that does not support CPU instruction set SSE4.2, migrate the VSA offline to another VMware ESXi server or cluster.
If the upgrade fails on the ESXi cluster and that cluster contains any servers that do not support CPU instruction set SSE4.2, modify the Enhanced vMotion Capability (EVC) settings within the VMware cluster to disallow vMotion from the newer servers that support SSE4.2 to the older servers.
Remove the older servers from their cluster. Power cycle the UnityVSA and retry the upgrade.
933016| UnityVSA| The system reports an alert that the network heartbeat is questionable on the peer when the local physical network cable is broken.
This occurs when:
1. UnityVSA SPA runs in the physical server #1, and UnityVSA SPB runs in the physical server #2.
2. The physical network cable #1 connects the uplink #1 of server #1 and the physical switch.
3. The physical network cable #2 connects the uplink #2 of server #2 and the physical switch.
4. The physical network cable #3 connects the uplink #1 of server #1 and the physical switch.
5. The physical network cable #4 connects the uplink #2 of server #2 and the physical switch.
6. When one of the physical network cables #1 or #2 is broken or pulled out, the system reports the alert. But if you pull out cable #1, the alert will be reported on SPB. If you pull out cable #2, the alert will be reported on SPA.
7. When one of the physical network cables #3 or #4 is broken or pulled out, the system would report an alert. But if you pull out the cable
| None.
Issue ID| Functional area| Description| Workaround/Solution
---|---|---|---
| | #3, the alert would be reported on SPB. If you pull out cable #4, the
alert will be reported on SPA.
This happens because the UnityVSA vNIC #1 is connected to the port group #1 and NIC #2 to the port group #2. Also, by the VMware teaming function, port group #1 has been bound to uplink #1 and port group #2 to uplink #2. It is expected that after pulling out cable #1 (the physical uplink #1 is down), the traffic going through NIC #1, port group #1, and uplink #1 should be cut off. However, because of a VMware limitation, the teaming only controls the egress, but not the ingress. The traffic sent from NIC #1 is truly cut off, but the traffic from the peer’s port group #1 still comes through the physical uplink
2 and is routed to the port group #1.
|
801368/ 802226| UnityVSA| The storage system restarts unexpectedly with a
monitor timeout or software watchdog timeout. This occurs when the system and
user data share the same data stores (physical disks) and the system is
overloaded with aggressive I/O workloads.
For example, a system can become overloaded when the workload includes heavy sequential write block I/O mixed with random file read and write I/O.
| It is recommended that user storage be on a separate data store from the system data store where UnityVSA is deployed.
If that is not possible, ensure that there are no more than four virtual disks on the system data store. If user data is allocated to the system data store, it can be migrated to a different data store. See the vSphere documentation for details. For UnityVSA deployment considerations, see the UnityVSA Installation Guide.
809371| UnityVSA| When configuring a NAS server for replication from a Unity
system to a UnityVSA system, the user can choose a storage processor on the
destination, although a single-SP UnityVSA has only one storage processor (SP
A). Choosing SP B and continuing to create the session results in an error.|
Choose SP A when replicating to a single-SP UnityVSA.
UNITYD-44726| Virtualization| If a VMware traditional datastore is extended
and does not have any host access, then host access cannot be added later.|
Delete the VMware datastore and recreate it. A datastore that has never had
any host access is supposed to be a clean datastore with no data.
940223 / 945505 / UNITYD-4468| Virtualization| A VM migration (using vMotion)
to or from the NFS3-NFS4 datastore sporadically fails when an SP is rebooted
during migration.| Manually restart the vMotion migration when the SP is back
online.
811020| Virtualization| When there are no datastores enabled for access to a
target ESXi host during replication, the storage system iSCSI targets are not
registered on the target ESXi server. When the Storage Replication Adapter
(SRA) requests that the storage system enable Snaps-Only access to the target
ESXi server, the operation succeeds, but the rescan does not discover the
snapshots.| Manually configure iSCSI target discovery of the storage systems’
iSCSI addresses on the ESXi hosts.
Issue ID| Functional area| Description|
Workaround/Solution
---|---|---|---
987324| Virtualization| With multiple VM clones from the same source VM, part
of the clone could fail.
vCenter Server reports events similar to:
Unable to access file xxx. vmdk since it is locked.
| To work around the issue in ESXi 5.0 or later, increase the number of times to retry opening the disk:
1. Log in to the ESXi host with root credentials.
2. Open the /etc/vmware/config file using a text editor.
3. Add this line to the end of the file: diskLib.openRetries=xx
[Where xx depends on the number of virtual machines being deployed in the vApp. VMware recommends a value between 20 and 50.]
4. Save and close the file.
5. Reboot the host for the changes to take effect.
988933| Virtualization| When using Dell Virtual Storage Integrator (VSI), VMware datastore creation fails on Unity All Flash and UnityVSA systems.| The issue is fixed in VSI 8.1. Refer to the following Knowledgebase articles for details:
· UnityVSA: KB# 163429
· Unity All Flash: KB# 36884
989789| Virtualization| When a VM migration in VMware vSphere is in progress, a planned failover of the underlying synchronous replication file system on Unity at the same time may cause VM migration failure on vSphere.| Do not perform a synchronous replication planned failover on Unity while migrating a VM on VMware vSphere at the same time. If the error occurs, wait until the planned failover completes and retry the VM migration in VMware vSphere.
Limitations
Learn about limitations in Unity.
Table 4. Limitations in the product version
Limitation | First affected release | Limitation lifted |
---|
In a replication cascading topology from an asynchronous replication session
to a synchronous replication session, the synchronous replication destination
data integration is not integrated.| 5.2.0.0.5.173| Still in effect.
Moving drives between Unity x80/F models and non-x80/F models is not
supported. This ensures that the drives are qualified and configured for the
correct platform and will provide optimal performance and longevity.|
5.1.0.0.5.394| Still in effect.
After a failover, the UNIX and Windows names may not display immediately and
could take up to 24 hours to display. You can manually refresh the username
for a UID or wait until the next system refresh to see the correct names.|
5.1.0.0.5.394| Still in effect.
A large thick file system (TB level) takes time to provision, even after the
operation returns a success message in Unisphere. While the provisioning
operation is in progress, many operations, such as asynchronous replication
creation, cannot be run and will fail due to timing out. Operating on a newly
created thick file system after a| All versions| Still in effect.
Limitation| First affected release| Limitation lifted
---|---|---
a certain amount of time is recommended. Run a query to check the status of
the operation.| |
When replicating VMware VMFS datastores, they are treated like Consistency
Groups in that they are subject to the same replication limits as CGs (for
example, the maximum number of replication sessions for CGs is 64, which also
applies to VMFS datastores).| All versions| Still in effect.
Using VSI 7.4 or VSI 8.0 to create a VMFS Datastore on a Unity all Flash array
or UnityVSA will fail. It is recommended to always provision VMFS datastores
and vVols through the Unity Unisphere UI or CLI.| All versions| Still in
effect.
VMware vSphere 6.5 is not supported on the UnityVSA 4.1.x.| 4.1.0.8940590|
4.2.0.9392909
When setting I/O limit policies, observe the following restrictions:
· For a shared KBPS I/O limit policy, set the limit to be at least 2048 KBPS.
· For a non-shared KBPS I/O limit policy, set the limit to be at least 1024 KBPS.
· The IOPS I/O limit policy’s minimum is 100 IOPS.
| 4.0.0.7329527| Still in effect.
The current Unity vVol implementation has not yet been fully certified for use
with VMware Horizon View. Although it may work, it is recommended that you do
not deploy VDI desktops using Unity vVol datastores. Support and issue
resolution will not be available for this integration.| 4.0.0.7329527| Still
in effect.
Environment and system requirements
- In order for your Unity Family system to function properly, ensure that your environment meets these minimal requirements.
34BSupport matrix
- Refer to the Unity Support Matrix on the support website for compatibility and interoperability information.
35BScreen size
- The minimum resolution for using the Unisphere GUI is 1024 x 768 pixels. Smaller screens may be able to display the GUI in full-screen mode.
36BSupportAssist and DHCP
- Do not use dynamic IP addresses (DHCP) for any components of the Secure Connect Gateway servers or managed devices unless they are configured with the FQDN of the Secure Connect Gateway server.
- An IP address is not needed for a SupportAssist configuration with a connection type of direct connection. If you use DHCP to assign IP addresses to any SupportAssist components (Secure Connect Gateway servers or managed devices), must have static IP addresses. Leases for the IP addresses that those devices use cannot be set to expire. It is recommended that you assign static IP addresses to those devices you plan to have managed by SupportAssist. For a SupportAssist configuration with a connection type of connection through a gateway, FQDNs can be configured instead of IP addresses.
- Software media, organization, and files
- Learn about software media, organization, and files required for the Unity Family.
37BRequired update
- It is recommended that you keep your Unity Family system up to date by upgrading to the latest software version at your earliest opportunity.
38BProblems downloading this release
- If you have difficulty downloading this release using Microsoft Internet Explorer version 7, try using a newer version of Microsoft Internet Explorer, Google Chrome, or Mozilla Firefox version 4 or greater.
Obtain and install product licenses
Before you begin:
- Register your product. This provides you instant access to easy-to-use tools to plan, install, maintain, and service your product.
- It also entitles you to software updates, installation tools, and more.
Ensure that you have the following:
- License authorization code (LAC)—The LAC is sent by email from Dell.
- The system serial number (physical systems) or the system UUID (virtual systems).
- Before you can create storage, you must install product and feature licenses on your system.
Initial Configuration
- On the Unisphere Licenses page of the Initial Configuration wizard, select Get License Online.
- Follow the instructions on the licensing website and download the license file locally.
- Note: Do not change the name of the license file.
- Select Install License and use Choose File to browse to the license file you downloaded locally.
- Select Open.
- The Results page will confirm the license was successfully installed.
Obtaining and installing additional licenses after the initial configuration
- In Unisphere, select the Settings icon, and then select Software and Licenses > License Information.
- Select a product license from the list to display a description of that license.
- To obtain a product license, select Get License Online.
- a. Use the link provided in the LAC email or access the product page on the support website, and download the license file locally.
- Note: Do not change the name of the license file.
- b. Transfer the license file to a computer that has access to the storage system, or connect the computer you used to obtain the license file to the same subnet of the storage system.
- To upload a product license, select Install License.
- a. Review the Software License and Maintenance Agreement and select Accept license agreement.
- b. Locate the license file, select it, and select Open to install the license file on the storage system.
- The license file is installed on the storage system.
- For sites with restricted internet access, or for more information on obtaining your license, go to the Unity Info Hub at dell.com/unitydocs.
Unique identifier for UnityVSA
- For UnityVSA, use the License Activation Key instead of the serial number or UUID as the unique identifier for setting up EMC Secure Remote Services (ESRS) and for obtaining customer support (professional editions).
Installing and enabling language packs
To install a language pack.
- Review the considerations included in the Software Media, Organization, and Files section.
- In Unisphere, select the Settings icon, and then select Software and Licenses > Language Packs.
- Select Obtain Language Pack Online and enter your Support credentials when prompted.
- Download the appropriate language pack file to your local system.
- Return to Unisphere and select Install Language Pack to launch the Install Language Pack wizard.
- Select Choose File and then select the language pack you want to upload.
- Select Next to begin the installation of the language pack onto your system.
- Select Finish.
- Once the language package installation is completed, view the results and close.
To enable a language pack on your system:
- In Unisphere, select the My Account icon and select Preferences.
- Select the preferred language from the Language list.
- Select OK.
Firmware
- Drive firmware bundle version 21 is included in this software OE bundle. Once the software OE installation has been completed, a prompt appears if updates are available.
- However, it is recommended to upgrade to the latest drive firmware before a software upgrade to help mitigate any non-disruptive upgrade issues.
- For a list of all drive firmware and their respective drives, refer to Knowledge Base article 000021322 (previously article 000490700).
- Online disk firmware updates (ODFU) occur automatically to update the drive firmware after you update to OE version 5.4. The system runs a preupgrade health check before upgrading the drive firmware.
- In addition, the system automatically dials home if a firmware upgrade failure occurs.
- You can manually enable or disable ODFU using the “svc_change_hw_config” service command or use that command to see the current status of the feature.
The following firmware variants are included with this release:
- If a lower revision is installed, the firmware is automatically upgraded to the revision contained in this version.
- If a higher revision is running, the firmware is not downgraded to the revision contained in this version.
- Note: The common data environment (CDE) for Unity OE 5.4 is 2.38.11, the same as the CDE for Unity OE 5.3.
Enclosure Type | Firmware |
---|---|
3U, 15-drive DAE | 2.38.11 |
2U, 25-drive DAE | 2.38.11 |
3U, 80-drive DAE | 2.38.11 |
DPE expander | 2.38.11 |
Platform Type | BIOS |
--- | --- |
2U, 25-drive DPE | 60.04 |
2U, 12-drive DPE | 60.04 |
2U, 25-drive DPE Unity XT 480/F, 680/F, and 880/F | 66.82 |
Documentation
Unity Family Info Hubs
- Additional relevant documentation can be obtained from the Unity Family Info Hub. Visit the Info Hub for your Unity Family product to access helpful utilities, videos, and other guides and https://www.dell.com/unitydocs.
Where to get help
- The Dell Technologies Support site (https://www.dell.com/support) contains important information about products and services including drivers, installation packages, product documentation, knowledge base articles, and advisories.
- A valid support contract and account might be required to access all the available information about a specific Dell Technologies product or service.
42BAdvisories
- For information on an individual technical or security advisory, go to the Online Support website and search by using the DSA number or “Dell Security Advisories” as the keyword.
- You can also select an option to receive alerts for Dell Technical Advisories (DTAs) and Dell Security Advisories (DSAs) to stay informed of critical issues and prevent potential impacts to your environment.
- Go to your account settings and preferences in Online Support, type the name of an individual product, click to select it from the list, and then click Add Alert. For the individual product or All Dell Products, enable the DTA’s and/or DSA’s toggle.
Notes, cautions, and warnings
- NOTE indicates important information that helps you make better use of your product.
- CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
- WARNING indicates potential for property damage, personal injury, or death.
- © 2016 – 2024 Dell Inc. or its subsidiaries. All rights reserved. Dell Technologies, Dell, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>