BEVERAGE-AIR GF34HCB 34 Inches Top Loading Glass and Plate Chiller in Stainless Steel Installation Guide
- June 3, 2024
- Beverage-Air
Table of Contents
GF34HCB 34 Inches Top Loading Glass and Plate Chiller in Stainless
Steel
Installation Guide
User Manual for GF Glass Freezers
WELCOME
Thank you for purchasing a Beverage-Air cabinet. This series has passed our
strict quality control inspection and meets the high standards set by
Beverage-Air! You have made a quality investment that with proper maintenance
will give you many years of reliable service!
Please read the following installation and maintenance instructions before
installing or using your unit. If you have any questions, Please call our
Technical Service Department at
800-684-1195. 8:00 AM to 5:00 PM EST
Important Information
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR USING, IF RECOMMENDED PROCEDURES ARE NOT FOLLOWED, WARRANTY CLAIMS MAY BE DENIED.
- Your warranty registration information is located with this manual. Please complete the card and submit it to Beverage-Air within TEN days of installation. Failure to properly register equipment may limit or void the warranty.
- Beverage-Air reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
SAFETY
This appliance has been designed with your safety in mind. It has many
features to keep you from being harmed. However, safe operation and
maintenance are your responsibilities. This appliance is not intended for use
by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
CAUTION
Use: When using this unit, please:
- Move it carefully. If on casters be sure the casters do NOT run over the power cord.
- Lock the casters when in use.
- Seek help. This machine is heavy! Be sure to move with enough help to avoid tipping or dropping the cabinet.
- Prevent children from playing in or on the cabinet. Persons unable to use this product must be prevented access.
- Follow all instructions. There are many safety labels and directions on the unit. Heed them.
- Watch your fingers. There may be pinch points near the door hinges.
CAUTION
Maintenance
Do NOT:
- Clean a frozen evaporator with a sharp object
- Clean a dirty condenser with a sharp object.
- Store gasoline, kerosene or any other flammable material near the cabinet.
Do ALWAYS
- Use a Beverage-Air recommended technician certified to repair R290 equipment.
- Use ONLY Beverage-Air factory service parts. Use of non OEM parts can be dangerous because of the design changes needed to safely use R290.
Important Information to Add
Record the model number, serial number and the date of installation here for
future reference. The model and serial numbers are on the unit’s serial number
dataplate, which is located on the left inside wall.
Model Number|
---|---
Serial Number|
Date of Installation|
Purchased From|
CAUTION
WARNING
Observe the Caution and Warning notices. They are indicators of important
safety information. Keep this manual for future reference.
IMPORTANT INFORMATION
This unit is intended to be used in a commercial application. That includes
bars and restaurants.
If installed in a residence some commercial service companies may not be able
to service it on site.
The manufacturer has designed and produced this machine with the finest in
materials. The manufacturer assumes no liability for units that have been
altered in any way. Alterations or part substitutions will void the warranty.
Limitations
The machine is designed for use indoors in a controlled environment. It must
be kept dry, not overheated or subjected to excessive cold. May only be
connected to a dedicated electrical circuit. Extension cords are not
permitted.
| Minimum| Maximum
---|---|---
Voltage| 104| 127
Room Air Temp| 60º F| 100º F
Air Flow Agency Approvals
These marks appear on the dataplate or serial tag, located in the inside of
the left wall. The dataplate also contains the model and serial numbers as
well as electrical requirements.
PRODUCT INFORMATION
Model| Cabinet Dimensions wxdxh (Inches)| lasi or GrSolsd Door|
Ful Loadl Amps| Power Cord Plug (NEMA)| Refrigerant Type / Charge
g /Charge oz
---|---|---|---|---|---
GF24HC| 241/8 x 261/8 x 33 5/8| Solid| 4.| 5-15P| R-290 / 60 / 212
GF34HC| 34 x 261/8 x 33 5/8| Solid| 4.
GF48HC| 48 x 261/8 x 33 5/8| Solid| 4.
- As shipped, all models are set to 0ºF, and maintain temperatures of 0ºF and below.
- All models are 115 volts, 60 Hz AC.
- ALWAYS REFERENCE YOUR EQUIPMENT DATA PLATE AMPS, REFRIGERANT AND REFRIGERANT CHARGE FOR THE MOST UP TO DATE AND ACCURATE VALUES.
- There are no access valves on the refrigeration system.
CLEARANCE AND PLACEMENT
Placement
Consider the following when selecting a location for your Refrigerator:
Clearance:
- Must not be covered – Top
- 0″ – Left
- 0″ – Right
- 2″ – Rear
- 0″ – Below
Floor Load: The floor on which the Refrigerator is located must be even
and level, free from vibrations, and strong enough to support the combined
weights of the unit and maximum product load.
Ventilation: Grille area at front must be free and clear of any object or
wall.
Power Outlet: The installation of this appliance requires a dedicated
power outlet located within the length of the unit’s power cord and be
accessible for the purpose to disconnect power.
UNPACKING AND SET UP
Carefully inspect the shipping carton for damage. This is the only time that
shipping damage may be claimed. If damage is suspected, open the carton
immediately and, if there is damage, retain the carton and contact the shipper
to make a claim. Do NOT contact the manufacturer.
Uncrating
Tools Needed: ¾” box wrench, adjustable wrench, level, flat head screw driver,
and box cutter.
- First, remove the cardboard top capping, all clear tape, and all staples including those at the bottom of the cardboard carton and skid.
- Next, start from the top of the carton. Using the box cutter, carefully make one continuous cut to the bottom of the skid. Remove cardboard carton and discard.
- Then, move unit as close to final position as possible before removing the skid.
- Remove the brackets securing the unit to the skid.
Note: The skid must be removed before the casters or legs can be
attached.
Do NOT tip unit on its front or sides. If tipped onto the back, unit must not
be started for 3 hours.
Skid Removal and Caster Attachment
Tip the unit forward and remove the skid.
WARNING
Risk of personal injury. Unit must be securely supported while attaching
casters or legs.
- Remove the shipping bolts using the ¾” box wrench while cabinet is held in one direction. Repeat the process while the cabinet is held in the opposite direction.
- None of the threads on the leg or caster stem should be visible once screwed in.
- Tilt the cabinet in one direction approximately 8” and block it securely with pieces of 2×4 lumber or other suitable material.
- Thread the stem casters or legs into the ½ -13 holes in the bottom of the cabinet. Tighten by hand as much as possible. Some models may already have levelers installed. If so, then the levelers will need to first be removed and discarded.
- Once the caster or leg cannot be turned any further, use a 3/4 inch wrench to tighten the nut in between the mounting plate and the wheel of the caster until snug.
- Repeat this procedure with unit secured in the opposite direction so as to access the remaining legs/ casters/levelers
- If plate casters or legs are installed instead of stem casters or legs, then repeat step 3 above and secure the plate with either #14 AB screws, or ¼-20 screws, depending upon which are required.
- If levelers are employed, then repeat step 3 above and thread the leveler in place. Then repeat step 6.
Leveling:
Cabinets must be leveled when installed. Level should be measured on the
headrail.
Failure to level your cabinet may result in door not sealing, closing
correctly, or condensed water draining not draining properly.
For cabinets with legs, rotate the foot of the leg with an adjustable wrench
to achieve desired height for leveling.
For cabinets with casters, leveling can be achieved by placing large washers
in between the ½’ stud and the holes located on the bottom of the case.
CAUTION
Do NOT loosen casters to level the cabinet. Casters MUST be tightly secured
to cabinet for full strength.
Install or attach any accessories that will be used Remove any plastic
covering the stainless steel.
ELECTRICAL
This is a cord-connected unit, and must be connected to its own dedicated
power supply. Check the dataplate on the achine to confirm the voltage and per
the dataplate use the correct fuses or HACR circuit breakers.
Note: Do not connect to GFI / GFCI outlets. Connection to that type of
outlet can result in product loss due to unsafe cabinet temperature when GFI
device trips from moisture.
Power Cord
This 115 volt model is equipped with a cord and 5-15P plug.
If the power cord becomes damaged, it must be replaced with the identical
cord.
Follow All National and Local Codes
This unit must be grounded. Do not use extension cords and do not disable or
by-pass ground prong on electrical plug.
Initial Start Up
Plug the power cord into the proper power supply.
The cabinet will soon begin to blow warm air out of the bottom area, and the
inside wall of the cabinet will begin to become cold.
The cabinet temperature has been set at the factory and should not need
adjustment, however if it was changed, the standard setting is 0º F.
Cautions
CAUTION
Care must be taken whenever moving or servicing the unit. The refrigerant is
contained in a sealed system, but if released it may be flammable.
USING THE UNIT
Operation is simple, just keep it connected to the correct power supply and
the refrigerator will maintain the internal temperature it has been set to.
Keep the doors closed as much as possible to avoid unnecessary run time.
The controller displays the current internal temperature.
Adjusting the set temperature lower will NOT cause the system to lower the
temperature faster. When on, the refrigeration system is always operating at
maximum.
For best results, make certain the unit remains powered and has achieved the
desired set point before loading it with product. Pull down time will vary
depending upon
the type of unit and ambient conditions
The temperature was set at the factory at 0 º F, but you can adjust it to your
own selected temperature. 30 seconds after adjustment, the display
automatically reverts to showing the current temperature.
The compressor and condenser fan motor will only be on when the controller
senses an increase in internal cabinet temperature passed the set point
The freezer will automatically defrost as needed, there is no set time for
defrost. Push and immediately release the “melting” or defrost button for a
manual defrost.
Note: Holding the defrost button in too long will shut the controller
off.
The internal fan will be on when the compressor is on. In
most cases the only thing displayed will be the cabinet temperature. When
something other than normal operation has occurred, a message will be shown.
Message Displayed | Why | What to do |
---|---|---|
Cabinet temperature too warm | Confirm doors or drawers are closed. | |
Door is open | Close door, if message does not change, call for service. | |
Compressor run time too long | Check doors closed. If yes, call for service. | |
Sensor unplugged or has failed | Call for service. |
SEQUENCE OF OPERATIONS FREEZER
The refrigerator operates based on the air temperature measured by the probe
located at the return air.
| ON| OFF
---|---|---
COMPONENT| OPERATION| CONTROLLER ACTION| OPERATION|
CONTROLLER ACTION
COMPRESSOR| Compressor turns on when the air temperature at the probe is above
the sum of the set point +2.5| The Compressor Contact is energized| Compressor
turns off when the air temperature at probe is equal to or less than the set
point -2.5| The Compressor Contact is de-energized
(ERC 112 – Terminal #1)| (ERC 112 – Terminal #1)
CONDENSER FAN| The Condenser Fan turns on when the Compressor is running| The
Condenser Fan is wired directly to the Compressor, not through the controller|
The Condenser Fan turns off when the Compressor is not running| The Condenser
Fan is wired directly to the Compressor, not through the controller
EVAPORATOR FAN| The Evaporator
Fan turns on when the Compressor is running| The Evaporator Fan is wired to
the Fan Contact.| The Evaporator Fan turns off when the Compressor is not
running,| The Evaporator Fan is wired to the Fan Contact.
(ERC 112 – Terminal #5)| (ERC 112 – Terminal #5)
DEFROST HEATER| The Defrost Heater will activate on cumulative Compressor
runtime of 6 hours, and when temperature drops too low| The Defrost Heater
Contact is energized| When either the defrost is not scheduled or the
temperature at defrost probe has reached the defrost termination temperature.|
The Defrost Heater Contact is de-energized
(ERC 112 – Terminal #6)| (ERC 112 – Terminal #6)
Condition| Compressor| Condenser Fan| Evaporator Fan|
Defrost Heater| Defrost Drain
---|---|---|---|---|---
Cabinet Temp > Set point + 2.5| ON| ON| ON| OFF| ON
Cabinet Temperature <= Set point – 2.5| OFF| OFF| OFF| OFF| ON
Defrost| OFF| OFF| Off| ON| ON
Electronic Controller Control Panel Display
| Defrost LED
---|---
On fixed:| Defrost active
Off:| Defrost is off
|
| Fan LED
On fixed:| Fan active
Off:| Fan Off
|
| Alarm LED
---|---
On fixed:| ALARM Present
Flashing:| ALARM Silenced
Off:| No Alarm
| Compressor LED
On fixed:| Compressor active
Flashing:| Delay, protection or activation blocked
Off:| No Alarm
NOTE: When switched on, the instrument panel performs a lamp test for a
few seconds.
Keyboard Functions
UP
Quick press and release
• Increases Set Poin
Long press and relea
• Increases brightnesssetlease|
DOWN
Quick press and release
• Decreases Set Pointd releas
Long press and release
• Decreases display brightness|
DEFROST (ESC)
Quick press and release
• Activates manual defro
Long press and release
• Controller enter stand-by mode|
SET (ENTER )
Quick press and release
• No Function
Long press and release
• Toggles displaypress and release
---|---|---|---
Note: When the controller is in a Standby Mode, a blue dot will be displayed as shown here. To switch out of Standby Mode, push and hold the Defrost button until the display reads ON.
CONTROL PANEL CONNECTIONS
Changing the Set point
The alarm condition is always signaled by the alarm icon
Press any button to silence the alarm, the relative icon will continue
flashing.
Alarm Code| Trigger| Automatic Clearance| Outputs|
Comments
---|---|---|---|---
“Hi”| Air temperature is higher than “ALA->Hat• for “ALA->Htd”| User
configured| Blink “Hi” with the highest temperature; If configured: cut in
alarm relay, beep the buzzer| High temperature alarm
“Lo”| Air temperature is lower than “LAt” for “Ltd”| User configured| Blink
“Lo” with the lowest temperature. If configured: cut in alarm relay, beep the
buzzer| Low temperature alarm
“Con”| Condenser temperature is too high or too low| User configured| Blink
“Con”. If configured: cut in alarm relay, beep the buzzer| Condenser alarm
“dor”| Door open for more than| Always| Blink “dor”. If configured: cut in
alarm relay, beep the buzzer| Door open alarm
“uHi”| Line voltage is higher than “Cop- >uHi”| Always| Blink “uHi”. If
configured: cut in alarm relay, beep the buzzer| High voltage alarm
“uLi”| Line voltage is higher than “Cop- >uLi”| Always| Blink “uLo”. If
configured: cut in alarm relay, beep the buzzer.| Low voltage alarm
“LEA”| Compressor continuous running for more than “ALA->LEA”| Always| Blink
“LEA”. If configured: cut in alarm relay, beep the buzzer| Leakage alarm
“E01”| “Si” error| Always| Blink “E0I”. If configured: cut in alarm relay,
beep the buzzer| “Si” sensor failure (short or open)
“E02”| “S1” error| Always| Blink “E02”. If configured: cut in alarm relay,
beep the”S2″ buzzer| sensor failure (short or open)
“E03”| “Si” error| Always| Blink “E03 “. If configured: cut in alarm relay,
beep the buzzer| “S3” sensor failure (short or open)
“E04”| “S1” error| Always| Blink “E04 “. If configured: cut in alarm relay,
beep the buzzer| “S4” sensor failure (short or open)
How to Acknowledge Alarms:
NOTE: If alarm exclusion times are in progress (ALA folder of the
parameter table), the alarm is not signaled.
CLEANING AND MAINTENANCE
Cleaning Schedule:| | |
---|---|---|---
Cabinet| Condenser coil| Gaskets| Routine maintenance
Daily wipe down| Quarterly cleaning| Daily inspection| Annually
Weekly interior| |
Daily Exterior Cleaning
It is much easier to clean on a regular basis than to have to remove stains
once they have built up.
- Wash with a clean sponge and a mild detergent that does not contain chlorine.
- Rinse with clean water.
- Dry with a soft cloth.
- Polish with a soft cloth, wiping with the grain.
- Wipe weekly with stainless steel cleaner.
Weekly Interior Cleaning
- Remove all food, food related items. Store the food at a safe temperature.
- Disconnect power to the unit (unplug it or switch the breaker off).
- Rinse with clean water and allow to air dry.
- Restore power.
- Return food to the unit when it has reached a safe temperature.
- Remove all loose food particles from the inside walls, floor, door liner and ceiling.
- Scrub all interior surfaces and door gaskets with a warm (100ºF to 110ºF) detergent solution and a soft scrub brush.
CONDENSER CLEANING
Keeping the condenser coil clean is critical to efficient operation.
- Unplug unit from power supply.
CAUTION Rotating fan blade can cause personal injury.
Unplug unit from power supply before beginning to clean condenser
- Remove the Phillips head screws on the left and right of the front panel
- Pull the panel away from the unit.
- Brush off the surface of the condenser fins. Do NOT bend the fins.
- Vacuum the surface of the condenser fins.
- To reinstall the front panel line up the screw holes and reinstall the Philips head screws.
Note: If the coil is greasy, the coil will need to be cleaned with coil
cleaner and that should be left to an experienced technician.
Note: Air filters are not recommended as they restrict the flow of
cooling air. Note: Red circles in image
denote screw heads.
METHODS FOR CLEANING STAINLESS STEEL
Cleaning Needed | Cleaning Agent | Method of Application | Affect on Finish |
---|---|---|---|
Smears and fingerprints | Areal 20, Lac-O-Nu, Lumin Wash O’Cedar Cream Polish, | ||
Stainless Shine. | Rub with cloth as directed on the package. | ||
Satisfactory for use on all finishes. | Provides barrier film to minimize |
prints.
Stubborn Spots and Stains, Baked-On Splatter, and Other Light Discolorations|
Allchem Concentrated Cleaner.| Apply with damp sponge or cloth
Rub with damp cloth.| Use in direction of polish lines on No. 4 (polished)
finish. May scratch No.
2 (mill) and Nos. 7 and 8 (polished) finishes.
Samae, Twinkle or Cameo Copper Cleaner| Rub with damp cloth.
Grade FFF Italian pumice, whiting, or talc.| Rub with dry cloth.
Liquid NuSteel
Paste NuSteel or DuBois Temp. Copper’s Stainless Steel Cleaner Revere
Stainless Cleaner Household cleansers, such as Old Dutch, Lighthouse,
Sunbrite, Wyandotte, Bab-0, Gold Dust, Sapolio, Bon Ami, Ajax, or Comet Grade
F Italian Pumice, Steel Bright, Lumin Cleaner, Zud, Restore, Ma-Clean, or
Highlite. Penny-Brite or Copper-Brite.| Use small amount of cleaner. Rub with
dry cloth using a small amount of cleaner. Apply with damp sponge or cloth.
Rub with a damp cloth. May contain chlorine bleaches. Rinse thoroughly after
use.
Rub with a damp cloth.
Rub with a dry cloth using a small amount of cleaner.
Heat tint or discoloration| Penny-Brite or Copper-Brite. Past NuSteel, DuBois
Temp,
or Tarnite. Revere Stainless Steel Cleaner. Allen Polish, Steel Bright,
Tenacious Deposits,
Rusty Discolorations, Industrial Atmospheric Stains Wyandotte, Bab-0 or Zud.|
Rub with a dry cloth
Rub with a dry cloth or stain-less steel wool.
Apply with damp sponge or cloth.
Rub with a damp cloth.
Burnt-On Foods and Grease Fatty Acids, Milkstone (where swabbing or rubbing is
not practical)| Easy-Off, De-Grease-It, 4 to 6% hot solution of such agents as
trisodium phosphate or sodium tripolyphosphate or 5 to 15% caustic soda
solution| Apply generous coating. Allow to stand for 10-15 minutes. Rinse.
Repeated application may be necessary.| Excellent removal, satisfactory for
use on all finishes.
Tenacious Deposits, Rusty Discolorations, Industrial
Atmospheric Stains| Oakite No. 33, Dilac Texo 12, Texo NY, Flash-Klenz, Caddy
Cleaner, Turco Scale 4368 or Permag 57.| Swab and soak with clean cloth. Let
stand 15 minutes or more according to directions on package, then rinse and
dry.| Satisfactory for use on all finishes
Hard Water Spots and Scale| Vinegar.
5% oxalic acid, 5% sulfamic acid, 5 to 10% phosphoric acid, or Dilac, Oakite
No. 33, Texo 12, Texo N.Y.| Swab or wipe with cloth. Rinse with water and dry.
Swab or soak with cloth. Let stand 10-15 minutes. Always follow with
neutralizer rinse, and dry.| Satisfactory for all finishes. Satisfactory for
all finishes. Effective on tenacious deposits or where scale has built up.
Trouble Diagnosis for the User
Malfunction| Possible Cause| Likely Solution
No cooling – unit is silent| Unit not plugged in.
Fuse or circuit breaker tripped. Power cord plug loose in outlet.| Connect to
proper voltage circuit Replace fuse or reset breaker.
Check outlet for loose connection, replace as needed
Unit cools but seems to be on all the time| Dirty condenser| Clean condenser
Space temperature too high| Dirty condenser
Evaporator iced over Unit in high temperature environment| Clean condenser
Defrost unit Reduce temperature of room
Space temperature too low| Temperature control| Adjust or replace control
Trouble Diagnosis for the Technician
No cooling – compressor does not hum| Temp control stuck in open position|
Replace temp control.
No cooling – compressor hums but does not start| Low voltage to unit.
Compressor starting system failure| Check voltage, correct as needed. Check
start relay and start capacitor. See next step.
No cooling – compressor starts but shuts off| Compressor start relay failure
Compressor start capacitor failure| Replace relay. Replace capacitor.
No cooling – compressor cycles on and off| Overheating weak overload| Clean
condenser, check fan motor and blade. Check refrigerant charge. Replace
overload.
Unit cools but turns on and off frequently| No product in cabinet. Temperature
control defective Refrigeration issue| Fill cabinet Replace control Have
system checked
Makes excessive noise| Tubing rattle Loose parts
Bent or broken fan blade Noisy fan motor| Check tubing for routing Check for
loose components Replace fan blade
Replace fan motor
FOR THE SERVICE TECH – R290
Refrigeration service should only be attempted by a trained trade
professional certified to work on R290 systems.
Here are some critical service items.
This list does not qualify anyone to service the unit. It is a reminder and
checklist for the service tech. Keep these in mind for R290 service:
- Wire nuts are NOT to be used when changing an electrical part.
- The switches in this product are sealed, only exact replacements may be used.
- The process tubes are to be used for service access.
- Cut out (with tubing cutter) refrigeration components that are to be replaced. Do NOT un-braze.
- Because R290 can be vented into the air during service, the venting MUST be in an area free from flame or spark. It must also be in a well ventilated area, with a nearby open window or door.
- A sign noting service of a system containing propane must be attached to the unit during refrigeration service.
- A combustible gas leak detector must be used to inform anyone in the area when propane is present in the air.
Other Information:
Evacuation: It is critical that a refrigeration system be leak free and
internally dry. A thorough evacuation with a good vacuum pump with a micron
gauge attached is the only way to ensure that the system is dry and ready for
a charge of refrigerant.
Charging: The system is critically charged and the proper type and amount MUST
be weighed in.
Overcharge symptoms: Unit will cool properly but the suction line temperature
will be unusually cold.
Compressor run time will be longer than normal.
Undercharge symptoms: Long run time, poor cooling and a hot compressor dome
are the main symptoms of an undercharge.
FOR THE SERVICE TECH – WIRING DIAGRAM
LIMITED WARRANTY
WARRANTY (Warranty valid in USA and Canada)
THREE (3) YEAR PARTS AND LABOR WARRANTY:
Beverage-Air Corporation warrants to the original purchaser of Beverage-Air
branded equipment, including all parts thereof, that such equipment is free
from defects in material and workmanship, under normal use, proper
maintenance, and service as indicated by Beverage-Air installation and
operation instructions, for a period of three (3) years from the date of
installation, or thirty-nine (39) Months from the date of shipment from the
manufacturer, whichever is earlier.
ADDITIONAL FOUR (4) YEAR COMPRESSOR PART
WARRANTY*: In addition to the warranty set forth above, Beverage-Air warrants
the hermetically/semi-hermetically sealed compressor (part only) for an
additional FOUR (4) years beyond the first three (3) years warranty period;
not to exceed eighty-seven (87) months from the date of shipment from
Beverage-Air, provided upon receipt of the compressor, manufacturer
examination shows the sealed compressor to be defective. This extended
warranty does not cover freight for the replacement compressor or freight for
the return of the failed compressor.
- Units shipped after 03/01/2020. Previous warranty applies to units shipped prior.
EXCEPTIONS:
CT96 Models carry a one (1) year parts and labor warranty, limited to fifteen (15) months from date of shipment from Beverage-Air. These are excluded from additional compressor warranty.
SR/SF (Slate) models carry a two (2) year parts and labor warranty, limited to twenty-seven (27) months from date of shipment from the Beverage-Air.
Blast Chillers carry a three (3) year parts and labor warranty; additional two (2) years compressor part only.
Units installed in Residential applications will be not covered under this warranty. Units are intended for Commercial use only.
BEVERAGE-AIR
Also, this extended compressor-part only warranty does NOT apply to any
electrical controls, condenser, evaporator, fan motors, overload switch,
starting relay, capacitors, temperature control, filter/drier, accumulator,
refrigeration tubing, wiring harness, labor charges, or supplies which are
covered by the warranty above.
Normal wear type parts, such as light bulbs/lamps and gaskets are not covered
by this warranty. For the purpose of this warranty, the original purchaser
shall be deemed to mean the individual or company for who the product was
originally installed.
Our obligation under this warranty shall be limited to repairing or replacing,
including labor, any part of such product, which proves thus defective.
Beverage-Air reserves the right to examine any product claimed to be
defective.
The labor warranty shall be for self-contained units only and for standard
straight time, which is defined as normal service rate time, for service
performed during normal working hours. Any service requested outside of a
servicer’s normal working hours will be covered under this warranty at the
normal rate and any additional overtime rate will be at the responsibility of
the equipment purchaser.
Any part or accessory determined to be defective in the product should be
returned to the company within thirty (30) days under the terms of this
warranty and must be accompanied by a record of the cabinet model, serial
number, and identified with a return material authorization number (RMA#)
issued by the manufacturer.
Special installation/applications, including remote locations, are limited in
coverage by this warranty. Any installation that requires extra work, and/or
travel, to gain access to the unit for service is the sole responsibility of
the equipment purchaser.
Improper operation resulting from factors, including but not limited to,
improper or negligent cleaning and maintenance,low voltage conditions,
inadequate wiring, outdoor use (unless otherwise specified) and accidental
damage are no manufacturing defects and are strictly the responsibility of the
purchaser.
With the exception of Blast Chillers product is designed for maintaining
temperature and not bringing food to a desired temperature therefore cannot be
held responsible for this function under warranty.
Units must be in a conditioned environment or warranty will be void.
Condensing coils must be cleaned at regular intervals.
Failure to do so can cause compressor malfunction and will void warranty.
Although cleaning requirements vary in accordance with operation of various
products, BeverageAir recommends a minimum monthly cleaning.
NO CLAIMS CAN BE MADE AGAINST THIS WARRANTY FOR SPOILAGE OF FOOD. PRODUCTS,
LOSS OF SALES OR CONSEQUENTIAL DAMAGES.
THE FOREGOING WARRANTIES ARE EXPRESSLY GIVEN IN LIEU OF ALL OTHER WARRANTIES,
EXPRESS, IMPLIED, OR STATUTORY, INCLUDING THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HERBY
DISCLAIMED, ALL OTHER OBLIGATIONS OR LIABILITIES ON OUR PART, AND WE NEITHER
ASSUME, NOR AUTHORIZE ANY OTHER PERSON TO ASSUME FOR US, ANY OBLIGATION OR
LIABILITY IN CONNECTION WITH THE SALE OF SAID REFRIGERATION UNITS OR ANY PARTS
THERE OF.
This warranty shall not be assignable and shall be honored only in so far as
the original purchaser. This warranty does not apply outside the limits of the
United States of America and Canada, nor does it apply to any part that has
been subject to misuse, neglect alteration, accident, or to any damage caused
by transportation, flood, fire, acts of terrorism, or acts of God.
LIMITATION OF LIABILITY:
Beverage-Air Corporation or their affiliates shall not be liable for any
indirect, incidental, special or consequential damages, or losses of a
commercial nature arising out of malfunction equipment or its parts components
thereof, as a result of defects in material or workmanship.
THE ORIGINAL OWNER’S SOLE AND EXCLUSIVE REMEDY AND BEVERAGE-AIR’S SOLE AND
EXCLUSIVE LIABILITY SHALL BE LIMITED TO THE REPAIR OR REPLACEMENT OF PARTS OR
COMPONENTS CONTAINED IN THE EQUIPMENT IDENTIFIED ABOVE WHICH UNDER NORMAL USE
AND SERVICE MALFUNCTION AS A RESULT OF DEFECTS IN MATERIAL OR WORKMANSHIP,
SUBJECT TO THE APPLICABLE PROVISIONS AND LIMITATIONS STATED ABOVE.
Warranty Registration
Register your product online at beverage-air.com/parts-service or fill out and mail the form below.
Cabinet Model Number: _____ Date Of Installation: ____
Cabinet Serial Number: ____
Location Of Product
Business Name: __
Business Street: _____
Business City: __ State: _ Postal Code:_____
Mail to: Beverage-Air, 3779 Champion Blvd, Winston-Salem, NC 27105
Rev. 06/22
Documents / Resources
|
BEVERAGE-AIR GF34HCB 34 Inches Top Loading Glass and Plate Chiller in
Stainless
Steel
[pdf] Installation Guide
GF34HCB 34 Inches Top Loading Glass and Plate Chiller in Stainless Steel,
GF34HCB, 34 Inches Top Loading Glass and Plate Chiller in Stainless Steel, Top
Loading Glass and Plate Chiller in Stainless Steel, Plate Chiller in Stainless
Steel, Chiller in Stainless Steel, Stainless Steel
---|---