WATERCO 70 XL Multicyclone Prefiltro Centrífugo Owner’s Manual
- July 15, 2024
- WATERCO
Table of Contents
WATERCO 70 XL Multicyclone Prefiltro Centrífugo Owner's Manual
SAFETY INFORMATION
- MultiCyclone 70XL is designed to work with water at temperatures greater than 0º C and less than 45ºC. The filter should never be operated outside of these temperatures or damage may occur.
- The installation should be carried out in accordance to the safety and the specific instructions for each facility.
- Any modification of the filter requires the prior consent from Waterco. Original replacement parts and accessories authorized by the manufacturer ensure a high level of safety. Waterco assumes no liability for the damage and injuries caused by unauthorised replacement parts and accessories.
- The user should make sure that the installation is carried out by qualified authorised persons and that these persons have first carefully read the following instructions.
- The operating safety of the filter is only guaranteed if the installation and operation instructions are correctly followed.
- In the event of defective operation or fault, contact Waterco or its nearest authorised service agent.
- To reduce the risk of injury, do not permit children to use this product unless they are closely upervised at all times.
- Incorrectly installed equipment may fail, causing severe injury or property damage.
INTRODUCTION
MultiCyclone 70XL is capable of saving water and reducing filter maintenance.
The MultiCyclone 70XL works on the basis of centrifugal water filtration.
There are no moving parts to wear and tear, and no filter media to clean or
replace.
TOP SHELL WATER OUTLET 4″ PORT
Incoming water is guided by a diverter plate so that it enters multiple hydro cyclones tangentially generating a strong centrifugal effect. This spins the sediment out to the hydro cyclone’s wall and then spirals it down to the sediment chamber, while the cleansed water spirals upwards.
The accumulation of sediment can be visibly monitored through the Multi Cyclone 70XL’s clear sight glass. The Multi Cyclone 70XL is cleaned by simply opening the purge valve. Multi Cyclone 70XL is ideal as a pre-filter to extend the life of your existing filter.
- Save Water
- Reduce backwash frequency.
Please Note: The Multi Cyclone 70XL is designed to filter sediment that is heavier than water; floating debris cannot be filtered out by centrifugal filtration.
INSTALLATION
Be sure to comply with the local plumbing codes. The filter may be plumbed into a drinking water system and would, therefore be subject to whichever local regulations that may apply. Be sure that all provisions for wastewater disposal meet local, state or national codes. Do not discharge water where it will cause flooding or damage. If the incoming water pressure is higher than the maximum operating pressure of 250kPa /2.5Bar /36 psi, a Pressure Regulating Valve (PRV) must be installed upstream of the filter inlet. The PRV should be set to 90% of the maximum operating pressure of the tank. If the incoming water flow is less than the filter’s minimum flow requirements, the filter’s filtration efficiency will be affected, please consult Waterco.
Multi Cyclone 70XL Recommended Operational Flow Rates
Minimum flow rate: 36m3/hr (158.5 GPM) Maximum flow rate: 96 m3/hr (422.7 GPM)
PLUMBING CONNECTION
-
Connect the outlet from your pump to the inlet of the Multi Cyclone 70XL.
Glue the plumbing to the Barrel unions and Allow 24 hours for glue (solvent) to set. Ensure solvents are not excessively applied to fittings as this could run into o’rings and create sealing problems. Screw the barrel union on to the inlet of your MultiCyclone 70XL and hand tighten. -
Connect from the outlet of the Multi Cyclone 70XL to the inlet of your filter.
Glue the plumbing to the Barrel unions and Allow 24 hours for glue (solvent) to set. Ensure solvents are not excessively applied to fittings as this could run into o’rings and create sealing problems. Screw the barrel union on to the outlet of your Multi Cyclone 70XL and hand tighten. -
Connect to Waste Line.
Glue the plumbing from the Sediment Purge Valve to your waste line. -
Turn on pump.
Be sure to check that there are no leaks from the connectors. If required, tighten by hand.
FILTER MAINTENANCE
Filter maintenance determined by the following conditions:
- The flow rate through the Multi Cyclone 70XL is insufficient to meet the demand.
- The sediment chamber is half filled with sediment.
The accumulation of sediment can be visibly monitored through the Multi Cyclone 70XL’s clear sight glass. The Multi Cyclone 70XL is cleaned by simply opening the purge valve
FLUSHING OUT THE SEDIMENT CHAMBER
Whilst the water pump is running simply open the sediment purge valve until the sediment has been flushed out. This is visible through the clear sight glass. Once the sediment has been flushed out, close the sediment purge valve.
WARRANTY
Multi Cyclone 70XL is covered by a 2 warranty.
For more information please refer to the Waterco “Warranty Terms & Conditions”
booklet. With our on going commitment to quality products and service Waterco
Limited reserves the right to alter the product in any manner and at any time
without prior warning. This information is to the best of our knowledge,
accurate at the time of printing. Any recommendations or suggestions are made
without warranty and without prejudice, since the use of our product is beyond
our control.
TECHNICAL SPECIFICATION
Pressure Rating: 250 kPa / 2.5 bar /36 psi
Minimum Flow Rate: 36m3/hr (158.5 GPM)
Maximum Flow Rate: 108 m3/hr (475.6 GPM)
DIMENSIONS
EXPLODED DIAGRAM
OFFICES – AUSTRALIA
NSW – SYDNEY (HEAD OFFICE) Tel: +61 2 9898 8600
QLD – BRISBANE Tel: +61 7 3299 9900
VIC/TAS – MELBOURNE Tel: +61 3 9764 1211
WA – PERTH Tel: +61 8 9273 1900
SA/NT – ADELAIDE Tel: +61 8 8244 6000
ACT DISTRIBUTION Tel: +61 2 6280 6476
OFFICES – OVERSEAS
WATERCO (EUROPE) LIMITED Sittingbourne, Kent, UK Tel: +44 (0) 1795 521 733
WATERCO FRANCE Saint Priest, France Tel: +33 4 72 79 33 30
WATERCO (USA) INC Augusta, Georgia, USA Tel: +1 706 793 7291
WATERCO CANADA Longueuil, Quebec, Canada Tel: +1 450 748 1421
WATERCO (NZ) LIMITED Auckland, New Zealand Tel: +64 9 525 7570
WATERCO © LIMITED Guangzhou, China Tel: +86 20 3222 2180
WATERCO (FAR EAST) SDN BHD Selangor, Malaysia Tel: +60 3 6145 6000
PT WATERCO INDONESIA Jakarta, Indonesia Tel: +62 21 4585 1481
WATERCO SINGAPORE INTL PTE LTD Nehsons Building, Singapore Tel: +65 6344 2378