ECOFLOW ZMH200-H-US Wave 1200W Portable Air Conditioner User Manual
- June 4, 2024
- ECOFLOW
Table of Contents
ZMH200-H-US Wave 1200W Portable Air Conditioner
User Manual
DISCLAIMER
Read all safety tips, warning messages, terms of use, and disclaimers carefully. Refer to the terms of use and disclaimer at https://ecoflow.com/pages/terms-of-use and stickers on the product before use. Users take full responsibility for all usage and operations. Familiarize yourself with the related regulations in your area. You are solely responsible for being aware of all relevant regulations and using EcoFlow products in a way that is compliant.
Specifications
General Information
Model number | EFH200 |
---|---|
Net weight | 17.5kg |
Dimensions | 20.39 x 12.2 x 16.38 in |
Wi-Fi | Supported |
Bluetooth | Supported |
Input Specifications
AC input voltage/frequency | 100-240V ~ 50/60Hz |
---|---|
AC input power | Max 700W |
Add-On Battery power | Max 600W |
Solar charging input | 11-35V Max 12A Max 200W |
Car charging input | 12 V/24V Max 8A Max 200W |
Cooling Specifications
Ambient temperature | 5°C ~ 50°C (41°F ~ 122°F) |
---|---|
Cooling temperature settings | 16°C ~ 30°C (60.8°F ~ 86°F) |
Cooling capacity | 1200W |
Circulation air volume | 290m³/h |
Refrigerant/amount | R134a/0.4kg |
Cooling input power (AC/DC) | 460W/410W |
Max cooling power | 600W |
Noise | <55dB |
No-Drain Function | Supported |
Shut Down When Full Function | Supported |
Other Specifications
EcoFlow Wave Add-On Battery | Supported |
---|---|
EcoFlow DELTA Max | Supported |
EcoFlow DELTA Max Extra Battery | Supported |
EcoFlow DELTA Pro | Supported |
EcoFlow DELTA Pro Extra Battery | Supported |
This device contains a radio transmission module with type approval code CMIIT ID:2021DP3313.
Safety Guidelines
- It is strictly prohibited to place this product near heat sources, such as fire or heating furnaces.
- It is prohibited to use this product in strong static or strong magnetic field environments.
- It is prohibited to disassemble this product in any way or puncture this product with sharp objects.
- It is prohibited to use wires or other metal objects to cause this product to short circuit.
- Do not use unofficial components or accessories. If replacements are necessary, please visit EcoFlow’s official sales channel for the relevant purchase information.
- It is strictly prohibited to stack other heavy objects on this product.
- Avoid impacts, falling, dropping, or strong vibrations. In the case of severe external impact, please turn off the power immediately and stop using the product. Keep the product properly secured during transport to avoid vibration and impact.
- Handle this product with care to prevent it from being damaged due to overturning. If the product is overturned and badly damaged, switch it off immediately.
- It is strictly prohibited to block or obstruct the inlet or outlets of this product.
- It is strictly prohibited to overturn this product, as there is a risk of damaging the compressor.
- Keep this product out of the reach of children and pets. Please supervise children during use and ensure they do not play with the equipment.
- Store the product in a dry and ventilated place.
- If the interface of this product becomes dirty, wipe it with a dry cloth.
- Do not expose this product to rain or sunlight.
- Handle this product with care. If it is accidentally overturned, it must be left for six hours.
- It is prohibited to forcibly block the fan during use.
- Do not drop foreign objects into the fan inlets and outlets as these could damage the fans.
- Keep the inlets and outlets of the appliance at least 0.5 m away from any walls and other obstructions that interfere with the air inlet and outlet.
- If the power cable is damaged, it must be replaced by the manufacturer, their service agent, or similarly qualified personnel in order to avoid hazards.
- Do not immerse this product in water or allow it to get wet. Do not use this product in the rain, damp conditions, or wet environments.
- Operating the equipment in a residential environment may cause radio interference.
- Do not allow persons with reduced physical, sensory or mental abilities or lack of experience and knowledge (including children) to use the appliance unless they are supervised or instructed
Getting Started
Description of Appearance
Icons on the LCD Screen
Using the Product
Short press the main power button to power the device Press and hold the main power button to switch off the device
Short press the main power button to power the device. After the device has
started, the LCD screen will be illuminated and the main power indicator light
will pulse.
The product will enter Sleep Mode if left idle for 5 minutes without any
activity, and the LCD screen will automatically switch off. If the product is
then operated, the LCD screen will automatically illuminate. To turn the LCD
screen on or off, short press the main power button.
Press and hold the main power button to switch off the machine.
When the Add-On Battery is the only power supply, pressing and holding the
main power button will also switch off the Add-On Battery.
Setting the Timer
Short press the timer button. The timer icon and time will flash to indicate
that you have entered the timer adjustment interface. Turn the dial to adjust
the time — turn clockwise to increase the time or counter-clockwise to
decrease the time.
When connected to an AC power supply, the machine automatically shuts down at
the set time;
When connected to the Add-On Battery alone, the machine automatically shuts
down when the screen battery has enough charge to be used for longer than the
set time. If the screen battery cannot be used for the entire set time, the
air conditioning has a built-in intelligent power distribution algorithm that
reduces the cooling effect by a certain amount to achieve a longer run time.
Setting the Temperature
Short press the temperature button. The temperature icon and the temperature will flash to indicate that you have entered the temperature adjustment interface. Turn the dial clockwise to decrease the temperature and counter- clockwise to increase the temperature.
Setting the Temperature Unit
Press and hold the temperature button for three seconds to toggle the
temperature between Fahrenheit and Celsius.
Intelligent power distribution function: Extends the run time of the machine
when connected only to the Add-On Battery/EcoFlow Power Station and when the
remaining charge is limited.
Setting the Operating Mode
Short press the Mode button to switch to Cooling Mode; short press again to switch to Fan Mode (Fan Mode is only available in Car Charging or Solar Charging Mode)
No-Drain Function
This product has a self-evaporating, drain-free system that sprays
condensation water from the evaporator to the condenser for heat dissipation
and evaporation, eliminating the need for frequent drainage in environments
with low humidity.
Note: Some water droplets may not evaporate and it is normal for the hot-
zone outlet to blow out a few water droplets. The no-drain function drains
most of the condensation, but a small amount of water may still remain in the
base. To avoid retaining water that may breed bacteria, tilt the machine
slightly when not in use to completely drain the remaining water through the
drainage port. Shut Down When Full Function The product is equipped with a
function that shuts it down when it is full of water. When the ambient
humidity is high, the air conditioner condensation cannot be completely
drained by the no-drain system and the internal water level gradually rises.
The machine has an overflow to prevent excessive water storage. After reaching
a predetermined water level, the function is triggered to shut down the
machine and prompt the user to connect the drainage tube to manually drain the
water.
Note: Tilting the product can affect the detection of the water level.
Excessive tilting can cause the water level to be inaccurately detected,
leading to unnecessary shutdown or the product not shutting down when full of
water.
The product should be positioned as horizontally as possible during use.
AC Power Supply
An AC power supply can be connected to power or charge the product.
When the product is connected to AC power, press and hold the main power
button and the machine will enter Standby Mode. If a battery is connected, the
battery pack will be charged at maximum power. When the product is connected
to AC power, short press the main power button, and the device will operate
normally. If a battery is connected, the product will prioritize providing
power to the air conditioner via the built-in intelligent charging algorithm
while simultaneously charging the battery pack at the optimum power.
Solar Charging
The product can be powered by solar energy. If a battery is connected when the
product is in Standby Mode, the battery can be charged at a maximum rate of
200W.
The operating state is limited by the power of the port and can only be
operated in Fan Mode when powered separately. There are no restrictions when
connected to other power sources (battery pack, AC power). If a battery is
connected, it can operate in Fan Mode and charge the battery simultaneously.
Recommendation: Where possible, a battery should be connected when using a car
or solar charging.
Car Charging
The product can be powered via the in-car charging connector, which can supply
a maximum current of 8A (supports 12V/24V) for charging when in standby mode .
The operating state is limited by the power of the port and can only be
operated in Fan Mode when powered separately. There are no restrictions when
connected to other power sources (battery, AC power). If a battery is
connected, it can operate in Fan Mode and charge the battery simultaneously.
Recommendation: Where possible, a battery should be connected when using a car
or solar charging.
Connecting the Add-On Battery
EcoFlow Wave Add-On Battery
Place the main unit on the top of the battery pack and slide it into place. A
clicking sound indicates that the main unit is properly connected to the
battery pack. Then, insert the battery plug into the battery connector of the
air conditioner.
(See battery pack instructions for further details)
Wave supports the following batteries: EcoFlow Wave Add-On Battery, DELTA
Max, DELTA Max Extra Battery, DELTA Pro, and DELTA Pro Extra Battery.
(If using a portable power station such as DELTA Max)
Take the DELTA Max cable and connect it to the air conditioner; the air
conditioner does not come with a separate cable for this.
To connect the DELTA Pro cable to the air conditioner, the adapter must be
connected first; the air conditioner does not come with a separate cable and
adapter for this.
Using the App
EcoFlow APP
Control, monitor and customize your portable power station from afar with the
EcoFlow App.
Download at:
https://download.ecoflow.com/app
Privacy Policy
By using EcoFlow Products, Applications, and Services, you consent to the
EcoFlow Term of Use and Privacy Policy, which you can access via the “About”
section of the “User” page on the EcoFlow App or on the official EcoFlow
website at https://www.ecoflow.com/policy/terms-of-
use and
https://www.ecoflow.com/policy/privacy-policy
Installation
Installing the cold-end fan shroud and duct
Installing ventilation ducts
Installing the hot-end fan shroud and duct
Installing the drainage tube
Use Scenarios
Tent
-
Place in an opening in the tent zipper with the cold end inside the tent and the hot end outside the tent
-
Place outside the tent with the cold air vent directed into the tent
-
Place inside the tent with the hot air vent directed outside the tent
RV
Indoors/kitchen
Frequently Asked Questions
No.| Question
category| Analysis of cause| Troubleshooting
---|---|---|---
1| The air outlet does
not blow air or
blows out little air| (i) The machine is not powered on or it is not switched
on;
(2) The air intake is obstructed or the blades are too dusty;
(3) The fan is not running;| (1) Check the power supply or connection, power
on properly and switch on the machine;
(2) Clean the debris from the air intake and regularly clean the dust from the
blades with a brush;
(3) Check the fan (see no.3);
2| The unit does
not cool or
performance is
poor| 1) It is not in Cooling Mode;
2) The ambient temperature is already at the set temperature;
3) It is outside the usable ambient temperature range or near the upper limit;
4) The machine is mounted incorrectly so that the air inlets and outlets are
blocked;
5) The compressor is not running;
(6) Refrigerant leakage;
(7) Capillary tubes are clogged;| l) Check that the operating mode and
temperature are set correctly;
2)Refer to the operating temperature range in the user manual. It is normal
for the machine to be
under a heavier load when the ambient temperature is high and the cooling
effect to thus be less;
(3-) Refer to the user manual to ensure the air conditioner is installed
correctly;
(4) Check the compressor (see no.4);
5)If the compressor is operating normally, there may be a refrigerant leakage
or the capillary tubes may be clogged. Consult a professional for service;
3| The fan is not
running| (1) There is a fault with the fan; 1 ‘…,
2) The fan wiring is disconnected or the power cable is broken;
(3) The fan is damaged;
4) The main board is damaged;| (1) Check the screen for error codes, rectify
the fault and try again;
2) Check the fan wiring;
3) Replace the fan to confirm whether the fan is damaged;
4) Replace the main board to confirm whether there is a fault;
4| The compressor is not running| (1) There is a fault with the compressor;
(2)The compressor wiring is – disconnected or the power cable is broken;
3) The main board is damaged;
(4)The compressor is damaged;| (1) Check the screen for error codes, rectify
the fault and try again;
2) Check the compressor wiring;
(3) Replace the main board to confirm whether there is a fault;
(4)1f the above items are all normal, the problem is most likely with the
compressor. The compressor winding resistance can also be checked and it can
be checked for abnormal noise, etc. before referring to a professional for
service;
5| Water is leaking from the base| ① The machine is tilted excessively;
② The internal water flow path of the machine is blocked;
③ The internal water pump is not working;
④ The ambient humidity is too high and the drainage pipe is not connected;| ①
The tilt of the machine should be less than 15°;
② Check the interior for any debris blocking the condensation flow path;
③ Check that the water pump is functioning properly (see no.6);
④ When the ambient humidity is high, there is increased condensation and the
drainage pipe must be connected to assist in draining the water;
6| The water pump is faulty| ① The water pump wiring is disconnected or the
power cable is broken;
② The main board is damaged;
③ The water pump is damaged or the water pump impeller is damaged;| ① Check
the water pump wiring;
② Replace the main board to confirm whether there is a fault;
③ Replace the water pump or the water pump impeller;
Considerations for use:
- The operation of the air conditioner depends mainly on the exchange of heat from one end to the other. Therefore, when installing avoid blocking or obstructing the air inlet or outlet as this will reduce the cooling effect.
- It is recommended that the area to be cooled be less than 5m² and without direct sunlight since sunlight can increase the temperature in the space and reduce the cooling effect.
- Air conditioners can be used in different scenarios using air ducts, which should be installed as short as possible and with a good bending curve to avoid causing excessive air resistance and affecting the efficiency of the air conditioner.
- The air conditioner has a built-in water pump to provide the no-drain function. However, if the ambient humidity is high the drainage pipe must be connected to assist in draining the water.
- The air conditioner should be switched off via the power switch, and users should avoid directly pulling the plug out or shutting off the power to switch it off, as this may reduce the service life of the air conditioner.
- The power cable provided by EcoFlow should be used as the AC power cable for the air conditioner. The power plug should be plugged in firmly and not be loose, as this will result in poor contact and damage the air conditioner.
- To avoid frequent stopping and starting of the compressor, the compressor is set to stop for at least two minutes after switching off. It is normal for the compressor to not move for two minutes when switching on and off within a short period of time.
- The air conditioner must be placed as horizontally as possible; it is not recommended to exceed the maximum tilt angle of 15°, otherwise, the reliability of the system operation will be reduced.
- Avoid exposure to rain or sunlight during operation, otherwise, air conditioner components could be damaged.
Troubleshooting
Fault code | Fault name | Solution |
---|---|---|
5 | Wireless module failure | Disconnect the power supply (including the |
battery) and restart the machine
10-12| Electric drive board fault| Disconnect the power supply (including the
battery) and restart the machine. If the problem persists, upgrade the system
via the app and ensure it has the latest firmware version
20-35| Power board fault| Disconnect the power supply (including the battery
pack) and restart the machine. If the problem persists, upgrade the system
via the app and ensure it has the latest firmware version
40-44| Temperature sensor fault| Disconnect the power supply (including the
battery) and restart the machine
60| Water level fault| Open the drainage port to drain the water, then restart
the machine
61| Cold zone fan fault| Disconnect the power supply (including the battery)
and restart the machine
62| Hot zone fan fault| Disconnect the power supply (including the battery)
and restart the machine
63 or 65| Overheat protection| Remove any obstructions at the hot zone inlet
and outlet, leave the machine for five minutes then restart the machine
64| Overcooling protection| Remove any obstructions at the cold zone inlet and
outlet, leave the machine for five minutes then restart the machine
Note: If the user still cannot solve the fault after handling the above solutions, please contact the after-sales personnel for maintenance.
What’s In the Box
Maintenance
- After the machine has been shut down for storage, close the socket cover to prevent the ingress of dust.
- After the machine has been shut down for storage, any water droplets must be manually removed from inside the machine to prevent the formation of bacteria during long-term storage and avoid water spillage when the machine is moved.
- It is recommended that this product be stored at 20°C to 30°C (68°F to 86°F) and kept away from water, heat sources, and other metal objects.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>