ABEM i5 40m TX Loops With 3x3m RX Coil Instructions

July 4, 2024
ABEM

ABEM i5 40m TX Loops With 3x3m RX Coil

ABEM-i5 40m-TX-Loops-With-3x3m-RX-Coil

PRE-SURVEY PROCEDURE

Prepare the batteries

  • Charge batteries using the supplied GroundTEM battery charger;
  • Guidance notes in the lid provide information on checking battery status;
  • No external adapter is required for the battery charger, just a standard “clover leaf” power lead;
  • When charged, install the batteries into the GroundTEM unit;
  • No external batteries are required with the GroundTEM system.

ABEM-i5 40m-TX-Loops-With-3x3m-RX-Coil-5

LAYOUT PROCEDURE

Lay out the transmitter loop

  • The loop has a lead-in/lead-out added to each end, so start at the instrument and pull wire off the reel until the first double-marker is found: this will be the bottom-left corner of the loop;
  • The TX loop can be laid out in a clockwise or anti-clockwise direction, so walk in a straight line until the first single marker is found: this is the next corner of the loop;
  • Now turn 90 degrees and walk again, to lay down the next side of the square a compass, optical square or tapes can be used to help make the loop square – it does not need to be a perfect square to still perform acceptably;
  • Use the other black markers on the loop as a guide for the remaining corner positions;
  • Another double marker should coincide with returning to the bottom-left corner of the transmitter loop;
  • The remaining wire on the drum is the lead-out back to the instrument.

Lay out the receiver coil

  • The receiver coil is relatively simple to locate cent rally;
  • On the lead-in cable, the first double marker should be held at the bottom-left corner of the TX loop;
  • Now walk towards the top-right corner of the TX loop and the end of the lead-in cable will coincide with the bottom left corner of the receiver coil;
  • Use the yellow markers on the receiver coil cable as guides for the corners and layout in a square roughly parallel with the TX loop;
  • Before making any connections, ensure connectors are clean and dry;
  • Plug the two ends of the RX coil cable into the two connectors on the drum (lead-in for use on 40x40m TX loops)/ pre-amp box (20x20m TX).

Connect the TX loop & RX coil to the GroundTEM

  • Before making any connections, ensure connectors are clean and dry;
  • The TX loop connects to the right hand side of the instrument;
  • The RX coil plugs into the left hand side of the instrument.

Power-up the instrument

  • Press the silver power button on the instrument;
  • The three green lights will indicate that batteries are functioning, and a GPS signal is being received (flashing light).

ABEM-i5 40m-TX-Loops-With-3x3m-RX-Coil-3

STARTING A MEASUREMENT

ABEM-i5 40m-TX-Loops-With-3x3m-RX-Coil-4

A. Connect to the GroundTEM instrument

  • On your chosen device, look for the GroundTEM Wi-Fi network and connect;
  • The SSID for the Wi-Fi network is GroundTEM#### where the digits are taken from the serial number;
  • The Wi-Fi password is GroundTEM (case sensitive);
  • Start the GroundTEM App (Android compatible, available from the Guideline Geo website);
  • Follow on-screen prompts if the device and instrument fail to connect.

B. Check configuration

  • The settings page also allows the choice of “list” or tab view in the data collection screens;
  • “List” has all views and functions on a single scrollable screen – if this is disabled, the app will display across three tabs as shown in right-most screenshots, above.

C. Choose a suitable measurement script
Scripts are named according to transmitter loop size – select the correct one for the current layout.

D. Enter a project name, line/station numbers, and select the measurement duration

  • The top box on the main data collection screen allows for data file management it is possible to survey individual stations, along survey lines, within projects;
  • The measurement duration should be selected: 5 or 10 minutes are normally sufficient but if data are coming in cleanly and consistently, it is possible to stop the measurement early without losing data.

E. Monitor the live results

  • It is possible to check that the instrument temperature and output current on both the high and low moment cycles is correct, using the monitoring bars;
  • Decay curves should also be inspected, to ensure that they are smooth and stable between repetitions.

FILE MANAGEMENT

Install ABEM GroundTEM Connect

  • Download the GroundTEM Connect software from the Guideline Geo webpages (use QR code on first page};
  • After installing, right click on the GroundTEM Connect icon and tick Run as Administrator.

Downloading data

  • Connect the PC to the GroundTEM Wi-Fi network (ID: GroundTEM#### Password: GroundTEM);
  • Click on Connect to Instrument (if it fails, firstly check the Wi-Fi connection, then make sure that the GroundTEM
  • Connect settings are correct( ), try the Default settings button, if necessary);
  • The left panel shows projects on the instrument, whilst the right panel shows the default download location;
  • If the right panel is blank, refresh the view ( );
  • Select the required proJects in the left window and click on the Copy button, between the two windows;
  • To change the download location, either add a new directory ( ) or work up through existing directories (.Jback );
  • If the USF file (an industry standard format, compatible with all 1D inversion software) is corrupt or missing, use the STB -> USF button to generate a new one from the selected project folder.

Read User Manual Online (PDF format)