WARNING
Remove all power supplies before doing the exchange. Act always with caution during the exchange!

  •  Needle nose pliers
  •  Screw driver phillips
  •  Screw driver flat
  •  Allen key 5
  •  Socket wrench 5
Material
  •  1x relay board RP3E6A (ID:13009)

  •  1x adapter cable (ID:16504)

  •  2x steel screw M3x16 (ID:952)

  •  3x plastic distance 8 mm (ID:9896)

  •  1x plastic screw M3x15 (ID:9895)

  • 1x plastic nut M3 (ID:7084)

  •  2x lock plates M3 red (ID:13674)

Installation

Unscrew the 4 hexagon socket screws from the cover and remove it carefully. Mind the connection cable between display and logic board. Unscrew the 4 cross recessed screws from the existing logic board and afterwards tilt it carefully to you. Remove carefully the connected cables: ribbon cable, 6-8-10-poles plugs. Afterwards you can remove the logic board from the control unit and disconnect the 2nd ribbon cable on the back. Remove the two, marked with the red arrows, steel distances in the housing. Put the plastic distances 8 mm between logic and relay board, insert the M3x16 steel screws through the estimated holes next to multi pin connector in logic board, plastic distances and relay board and secure the screws with the red lock plates. For the 3rd hole use the plastic screw M3x15 and secure it with plastic nut. Connect the relay board with the multi-pin connector from the logic board.
NOTE
4 pins must stay free see Figure 9. Orientation brings the mounting holes of both boards – they must be in line. Connect the adapter cable with the 10 and 6-pole connector, after connect blue connectors with related one on the relay board. Connect both ribbon cable and 8-pole connector with the logic board, after install the logic + relay board back to the control (two small screws for original installation will remain). Take care of possible damage of cables or other parts. Connect cable between display cover and logic board. Perform a Firmware update before installing display cover on the unit. This update is important for the following programming steps (use FW version display 1507, logic 219 or higher). For a detailed description on how to preform a firmware update, please refer to separate manual. During display cover installation, pay attention to the O-ring which must sit correct between cover and housing and fix it with the 4 hexagon socket screws.

EMERSON RP3E Bettis RTS Relay Board Electric Actuator
10

Programming

For programming, request download of SMARTTOOL2 through your Sales Representative. After the successful installation and registration, connect with the actuator. Use the Wizard and choose function “Install Extension Kit” and press “Apply”. At the line “RP3E6A: 6x Relay Outputs, 3x Inputs” press “Apply” and confirm the installation by pressing “Ja”. After installation press the “Refresh Button”. In parameter group “9. Bin. Input” and “10. Relay” you can define the functionality of the different relays.