HBEZON Aris3230-BK Double Door Built in Iron Cabinet Instruction Manual
- June 28, 2024
- HBEZON
Table of Contents
HBEZON Aris3230-BK Double Door Built in Iron Cabinet
Specifications
- Dimensions: 32 in. (W) x 30 in. (H) x 4.8 in. (D)
- Power Requirement: 120 VAC 20 Amp GFI protected Circuit
- Voltage: AC110-12V, 50/60Hz
Product Usage Instructions
Installation Instructions
Before starting the installation process, ensure that all safety
precautions are followed.
- Unpack the LED cabinet on a protected surface to prevent damage.
- Avoid drilling into any existing wiring or pipe work that may be concealed behind the wall.
- It is recommended that a certified electrician performs the installation and connects the mirror to a GFI protectedcircuit.
Maintenance
To maintain the LED medicine mirror:
- Wipe clean with a soft damp cloth.
- Apply glass cleaner to a cloth and avoid direct application to the mirror surface.
- Avoid abrasive cleaners as they may damage the finish or exposed LED strip.
Surface Mount Instructions
- Measure and mark the back mounting holes on the wall.
- Drill holes and insert the plastic expansion bolts.
- Ensure the horizontal line connecting the marked locations is level.
- Connect the hardwire to the power line with the power off (Voltage: AC110-12V, 50/60Hz).
- Attach the cabinet to the wall using mounting screws from the hardware pack.
FAQ
-
Q: Can I use the mirror outdoors?
A: No, the mirror should not be used outdoors as per safety instructions. -
Q: What should I do if I encounter difficulties during installation?
A: If you face any challenges during installation, it is recommended to consult a qualified electrician for assistance.
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical furnishing, basic precautions should always be followed ,including the following:
WARNING
To reduce the risk of burns,fire,electric shock or injury to persons.
Use this furnishing only for its intended use as described in these
instructions. Do not use attachments not recommended by the manufacturer.
Never drop or insert any object into any opening.Do not use outdoors.
WARNING:
Risk of electric shock.Connect this furnishing to a properly grounded circuit
only. See grounding instructions.
ELECTRIC CONNECTIONS
ALL WIRING SHOULD BE DONE BY A QUALIFIED LICENCED ELECTRICIAN.
WARNING
Shut off power before wiring.
Requires 120 VAC 20 Amp GFI protected Circuit.
GROUNDING INSTRUCTIONS
CAUTION:
This product must be connected to a grounded metal permanent wiring system or
an equipment-grounding conductor must be run with the circuit conductors and
connected to the equipment grounding terminal or lead on the product.
WARNING:
An Electrical option mirror must be wired to a 20 Amp GFI(Ground Fault
Interrupter) protected circuit when used in bathrooms and all other locations
required by the National Electric Code.
HOW TO CONNECTIONS
HARDWARE AND TOOLS ( Tools not included)
INSTALLATION INSTRUCTIONS
Please read carefully and save these instructions
Don’t discard any of the packaging until you are sure that you have all of the
parts and the fitings Make sure power to the junction box is off before
commencing installation.
IMPORTANT
- Unpack LED cabinet. DO NOT lay cabinet on tiled or concrete surface prior to installation Cabinet must be on protected surface to prevent chipping of the corners
- Care must be taken before drilling pilot holes to avoid any existing wiring or pipe work that may be concealed.
- A certified electrician must perform all work.The mirror must be connected to a GFI
MAINTENANCE
Wipe clean with a soft damp cloth. Apply glass cleaner to cloth and do not
apply directly to mirror Never use abrasive cleaners as these could damage the
finish or exposed LEDstrip 2
INSTALLATION
Please refer to below surface mount or recess mount method.
SURFACE MOUNT INSTRUCTION
Step 1
Unpack the LED medicine mirror and prepare tools needed. Step 2
Measure and mark the back mounting holes on the wall. Step 3
Drill holes,and put in the plastic expansion bolt. Step 4
Connect hardwire to power line.
Make sure the power off(Voltage:AC110-12V,50/60Hz) Step 5 Attach the cabinet to the wall with mountin screws from
the hardware pack.
Hinge adjustment
RECESS MOUNT INSTRUCTIONS
NOTE: Rough opening is not an exact measurement. The extra space allows
cabinet to be inserted into the opening. Add shims to level and tighten space
if necessary. Additional framing might be required.
Rough Wall Opening
Overall Size| Rough Wall Opening
---|---
32 in.(W) x 30 in.(H) x 4.8 in.(D)| 31-1/16 in.(W) x 24-7/32 in.(H) x 3-1/2
in.(D)
36 in.(W) x 32 in.(H) x 4.8 in.(D)| 35-1/16 in.(W) x 26-7/32 in.(H) x 3-1/2
in.(D)
Step 1
NOTE: Before cutting the rough opening,check for pipes, electrical
cables, or heatingducts. If it is required to remove part of stud, make sure
that the wall is not a load bearing wall. Prepare the opening in the wall for
the cabinet body. Make sure that there is support on both sides of the opening
to attach the cabinet body, as shown.
NOTE: The cabinet height should be a minimum 2 in. above faucet.
Step 2
Connect hardwire to power line.
Make sure the power off(Voltage:AC110-12V,50/60Hz) Step 3
Position the cabinet body in the rough wall opening. Make sure that the
cabinet body flange covers the wall opening uniformly. Secure both sides of
the cabinet body to the wall supports using mounting screws . NOTE: The
cabinet body must be level for the door to work properly.
INTRODUCTION OF TOUCH FUNCTION
After power on, the button shows white and it is in waiting stagte, click to
turn on the light function and the button turn on yellow.
Click again to turn off the light function and the button to turn to white.
Long click the button to make the light gradually dims Click the button again and the light gradually brightens
After power on, the button shows white and it is in waiting state, click to
turn on the defogging function and the button turn on yellow.
Click again to turn off the defogging function and the button to turn to
white.
After power on, the button shows white and it is in waiting state, click to
turn on the light function and the white turn on yellow.
Long press to switch the color temperature of light by 3k-yellow, 4k-natural
or 6k-cold white
A – Width
B – Height
C – Depth
Unit: Inch
SKU# A B C
- Aris3230-BK 32 30 4.8
- Aris3230-GD 32 30 4.8
- Aris3632-BK 36 32 4.8
- Aris3632-GD 36 32 4.8
Note: All dimensions & specifications are approximate and subject to change without notice.
Customer Service:
For any questions or queries regarding our products, please contact our
support team:
Email:cs@hbezon.com
Website :www.hbezon.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>