Safety Precautions

  1. Read all safety precautions and installation instructions carefully before installing or servicing this fixture. Failure to comply with these instructions could result in potentially fatal electric shock and/or property damage.

  2. It is recommended that a qualified electrician perform all wiring. This fixture must be wired in accordance with all national and local electrical codes.

  3. Do not handle any energized fixture or attempt to energize any fixture with wet hands or while standing on a wet or damp surface or in water.

  4. This fixture is designed for use in a 120VAC, 60Hz fused circuit. This fixture is compatible with TRIAC
    (forward-phase or leading-edge) and ELV (reverse-phase or trailing-edge) dimmers.

  5. Make sure that the power source conforms to the requirements of the fixture. (See labels on the fixture housing).

  6. To reduce the risk of electrical shock, and to assure proper operation, this fixture must be adequately grounded. To accomplish proper grounding, there must be a separate ground wire (green) contact between this fixture and the ground connection of your main power supply panel.

  7. This fixture is intended to be used for general indoor lighting in dry or damp locations.

  8. Disclaimer
    Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and Canadian ICES-005 (B) /NMB-005 (B). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  9. Reorient or relocate the receiver antenna.

  10. Increase the separation between the equipment and receiver.

  11. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

  12. Consult with the dealer or an experienced radio/TV technician for help.
    Any modifications to this fixture may void the warranty and interfere with the safe operation of the luminaire. Operation is subject to the following two conditions:

  13. this device may not cause interference,

  14. this device must accept any interference, including interference that may cause undesired operation of the device.

  15. This fixture is suitable for ceiling and wall mounting.

NEEDED TOOLS

  1. Tools and material needed: screwdriver, pliers, wire nuts, electrical tape.
  2. To help prevent the possibility of electrical shock, the use of rubber sole shoes is recommended.
  3. Exercise care when handling the fixture to avoid cuts or abrasions.
  4. f a ladder is needed, make sure to use a sturdy wooden one.

Assembly Instructions

  • Step 1 – Preparing for installation

    • Disconnect electrical power before installing or servicing any part of this fixture.
    • Remove fixture from carton; remove components from hardware kit.
    • C. Place the diffuser off to the side.
      Wiring – All wiring must take place inside junction box (not included)
      Caution:
      Make sure power is off at fuse or circuit breaker box. Check power wires for damage or scrapes. If the power supply wires are within three inches of the LED driver, use a wire suitable for at least 90°C (194°F). Note: Most dwellings built before 1985 have supply wire rated to 60°C. Consult a qualified electrician to ensure correct branch circuit conductor before installing.
  • Step 2 – Wiring Fixture

    • Make all wire connections to appropriate wire. Secure with wire nuts (provided).
    •  Connect the green wire or bare wire from the fixture to the supply power source ground wire.
    • For none-dimming fixture. Connect the white wire from the fixture to the white (N) wire from supply power source. Connect the black fixture wire to the black (L) wire from supply power source.
    • For TRIAC dimming. Connect the white wire from the fixture to the white (N) wire from dimming source per dimmer wiring instructions. Connect the black wire from the fixture to the black (L) wire from dimmer supply power source per dimmer wiring instructions.
    • Do not mix wires. Pull on each wire lead to make sure connections are secure. Make certain no bare wires are exposed outside of wire connectors. Tuck all connections neatly into junction box.
  • Step 3 – Install pan

    • A. Install pan (1) to the ceiling by align keyholes slots to the junction box (not included) then using two screws to secure it.
  • Step 4 – Color Changing Temperature Adjustment, CCT (if desired)

    • Adjust CCT switches on each board accordingly to the desired color temperature as seen below. All boards must be set the same way.
      Note:
      Fixture is preset to 3000K from factory. Power to fixture must always be turned OFF prior to adjusting CCT switches.
      COLOR TEMPERATURE ADJUSTMENT SETTING****GlobaLux LIGHTING DCL2 LED
Closet Disk Lighting-fig4
  • Step 5 – Install diffuser

    • Install diffuser (2) to the pan by aligning top side flushed to ceiling pan (1) then put the diffuser back. And turn it clockwise to tight.
  • Step 6 – Power to the fixture can now be restored