PlanetCare 2.0 Circular Washing Machine Microfibre Filter User Manual
- June 27, 2024
- PlanetCare
Table of Contents
PlanetCare 2.0 Circular Washing Machine Microfibre Filter
Product Specifications
- Product Name: PlanetCare 2.0
- Function: Filters microfibers from laundry
- Main Parts: Filter housing and filter cartridge
- Includes: Filter head, filter housing, filter cartridges, drain\ hose, washing machine holder, filter holder, logo, screw, hose adapter, large hose adapter (USA/Canada only)
Product Usage Instructions
Installation
#1 Attaching the Filter Holder on Your Washing Machine
PlanetCare 2.0 can be attached to your washing machine or a nearby vertical surface for stability and accessibility. Follow\ these steps:
- Clean the surface where you will attach the holder with 70%\ alcohol.
- Peel off the protection layer on the double-sided tape of the holder.
- Attach the holder to the cleaned surface and press firmly for 5 seconds.
- For optimal adhesion, leave the holder for 24 hours before attaching the filter.
#2 Attaching the Filter Holder on Your PlanetCare 2.0 Microfiber Filter
Attach the holder to your PlanetCare 2.0 microfiber filter\ following these guidelines:
- Left Side Placement: Fit the holder on the right side using the supplied screw.
- Right Side Placement: Fit the holder on the\ left side using the supplied screw.
- Logo Placement: Attach the logo on the\ opposite side of the holder.
IMPORTANT: Do not tighten the screw without the holder to avoid damage to the filter.
#3 Connect the Hoses
PlanetCare 2.0 has two hoses for installation: IN for water from the washing machine to the filter and OUT for water from the filter to the drain. Ensure secure connections before use.
Frequently Asked Questions
- Q: How often should I replace the filter cartridge?
- A: When the filter cartridge is full, it needs to be replaced with a clean one. Plan to replace it as per your usage frequency and volume of laundry.
- Q: Can I wash the filter cartridge instead of replacing it?
- A: No, the filter cartridge should be replaced with a new one when full. Used cartridges can be sent back to PlanetCare for recycling.
Questions?
Product Information
Welcome to the PlanetCare filtering community! We are happy to have you on board to prevent the release of microfibres into our oceans. PlanetCare 2.0 is a filter that attaches to your washing machine and it filters microfibers from your laundry. The filter consists of two main parts: the filter housing and filter cartridge. When the filter cartridge is full, you will need to replace it with a clean one. When you’re up to your last clean \cartridge, pack the used cartridges in the box they were shipped in and send them back to PlanetCare for cleaning and recycling. The filtering medium of the cartridge with the caught microfibers is stored for recycling, while the rest of the cartridge is reused and shipped back to PlanetCare users. To ensure easy installation and use, please follow the steps described in the following pages.
WHAT’S IN THE BOX?
INSTALLATION
1 ATTACHING THE FILTER HOLDER ON YOUR WASHING MACHINE
PlanetCare 2.0 can be fitted on your washing machine or any other vertical \surface near by, as long as it ensures stability and easy access. To attach the filter holder, use the double-sided tape on the filter holder. Do not worry, it is strong enough to hold it in place firmly. You can also attach the holder with two screws (not included).
HOW TO ATTACH THE HOLDER:
Select a section of the washing machine (or other surface) that is as even as possible. Thoroughly clean the surface where you’ll attach the holder (this is best done with 70% alcohol). Be careful not to touch the sticky tape after you’ve removed the protection layer. Attach the holder to the cleaned surface & press firmly for 5 seconds.
To reach optimal adhesion, the holder should be left for 24 hours before attaching the filter.
2 ATTACHING THE FILTER HOLDER ON YOUR PLANETCARE 2.0 MICROFIBER FILTER
You will need to attach the holder on your PlanetCare 2.0 microfiber filter. The holder does not come pre-installed, because you can install it on either side of your washing machine.
3 CONNECT THE HOSES
PlanetCare 2.0 comes equipped with two hoses that are joined together for easier installation. Water from the washing machine into the filter comes from the hose marked with “IN”, while water from the filter and into the drain is marked with “OUT”.
Before using the filter, make sure that you connected the hoses securely.
-
CONNECT TO THE FILTER
Make sure that you correctly attach the hose to the filter – watch for “IN”\ and “OUT” marks on the connectors and hoses. -
CONNECT TO THE WASHING MACHINE AND DRAIN
Attach the hose connector to the end of the “IN” hose (the shorter one) and connect it to the drain hose from your washing machine. Connect the end of the “OUT” hose to the drain.
4 ATTACH THE FILTER CARTRIDGE
PlanetCare 2.0 filter cartridges are attached to the filter housing with a bayonet attachment that securely holds them in place.
Before using the filter, make sure that the cartridge is attached securely.
CONNECT THE CARTRIDGE TO THE FILTER HOUSING
Affix the cartridge to the top of the housing and twist it to the right until you feel a slight click. That is the indicator that the cartridge is securely attached.
ATTACH FILTER TO THE HOLDER
Slide the filter onto the filter holder securely. Your PlanetCare 2.0 microfiber filter is now correctly installed and ready to use.
FINE-TUNING
WATCH FINE TUNING VIDEO
BYPASS AND CARTRIDGE REPLACEMENT INDICATOR
This filter is equipped with an automatic bypass that activates when the cartridge reaches full capacity. When the handle is in raised position, it serves as a visual indicator that it is time to\ replace the cartridge. The bypass can also be triggered manually when washing clothes made from natural materials.
PERFORMANCE ADJUSTMENT
In some cases your washing machine might indicate an error while pumping water out of the machine and your clothes might not be drained properly. That is an indication that the automatic bypass has not been triggered when the cartridge was full. On the other hand, sometimes it might happen that the automatic bypass is triggered too soon, before the cartridge is truly filled. Do not worry, it’s all a matter of a small adjustment.
PlanetCare 2.0 has a setting ring that adjusts the sensitivity of the automatic bypass.
FACTORY SETTING IS TOO WEAK
If the bypass indicator turns on before your cartridge is fully used, the factory setting is too weak. This results in your cartridge enduring fewer washes than it’s capable of.
HOW TO FIX IT?
Turn the adjustment wheel one line towards the MAX indicator (to the left). Repeat this until you see an increase in filter cartridge durability. If your machine begins to have difficulty in pumping water (error message on washing machine), turn the wheel back one line towards the MIN indicator.
FACTORY SETTING IS TOO STRONG
If the bypass indicator doesn’t activate automatically after the cartridge is \full, the factory setting is too strong. This may lead to wet clothes or difficulty in pumping water (error message on washing machine).
HOW TO FIX IT?
Adjust the wheel one line towards the MIN indicator (to the right), and repeat until the bypass starts activating automatically for smooth operation (properly drained clothes and no error messages on the washing machine).
THANK YOU
By using the PlanetCare 2.0 microfiber filter, you are part of a community of Ocean Heroes – individuals who fight microplastic pollution at the source.
INSPIRE OTHERS!
Because we need more Ocean Heroes like you! Share your plastic-free washing routine and inspire others to join us in the fight against microplastic pollution at the source! Tag us@planetcare.solutions and use the hashtag
planetcarefilters
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>