Product Information

Specifications

  • Manufacturer: Mark Tanner MBA
  • Model Number: 0662555_R07

Product Usage Instructions

General Guidelines
Consultation with or consent of the manufacturer is necessary for different types of use. Tanner MBA devices used for transporting flammable or explosive gases, vapors, mists, or dusts must be specifically designed. Standard Tanner MBA devices may not be used in hazardous areas without appropriate adjustments to the
technical specifications.
Note: Only qualified personnel should perform maintenance on the electrical components. Any changes or additions to the device will invalidate the declaration of conformity from the manufacturer.

Transport Packaging
The transport packaging is minimized for safe transportation of quality parts without damage. The material is fully recyclable.
Disposal costs are the responsibility of the recipient. The packaging can be returned, with transportation costs borne by the recipient. Ensure the packaging is not contaminated and separate it into appropriate groups for disposal.

FAQ (Frequently Asked Questions)

  1. Q: Can standard Tanner MBA devices be used in hazardous areas?
    A: No, standard Tanner MBA devices may not be used in hazardous areas without appropriate adjustments to the technical specifications.

  2. Q: Who should perform maintenance on the electrical components?
    A: Only qualified personnel should perform maintenance on the electrical components to ensure safety and compliance with regulations.

Warning
Incorrect installation, adjustment, alteration, repair or maintenance work may lead to material damage or injury. All work must be carried out by certified, qualified professionals. If the appliance is not positioned in accordance with the instructions, the warranty shall be rendered void. This appliance is not intended for use by children or persons with a physical, sensory or mental handicap, or who lack the required experience or expertise, unless they are supervised or have been instructed in the use of the appliance by somebody who is responsible for their safety.Children must be supervised to ensure that they do not play with the appliance. The information in this document is subject to change without notice. The most recent version of this manual is always available at www.markclimate.com/downloads.

General instructions
Read these instructions carefully prior to installation and use. Save this manual for reference purposes.
The product may only be used as described in the technical manual. The warranty applies only if the product is used in the intended manner and in accordance with the instructions.
The manufacturer continuously strives to improve products and reserves the right to make changes to specifications without prior notice. The technical details are assumed to be correct but do not form a basis for a contract or guarantee. All orders are accepted under the standard conditions of our general sales and delivery conditions (available on request).

Intended use

Tanner MBA is a waterfed hanging air heater for ventilation and air- conditioning in:

  • Office spaces
  • Meeting and exhibition areas
  • Recreational areas
  • Industrial and manufacturing buildings
  • Greenhouses
  • Shops, supermarkets, shopping areas with a ceiling height of about 2,5 to 5 meter.

Transport of air that is:

  • Dust free
  • Without harmful substances
  • Non-agressive
  • Non-corrosive
  • Not flammable

Consultation with or consent of the manufacturer is necessary for differents type of use.
Tanner MBA devices that are used for transporting flammable or explosive gasses, vapors, mists or dusts must be specifically designed. Standard Tanner MBA devices may not be used in hazardous areas without appropriate adjustments to the technical specifications.

Note:
The Tanner MBA device may only be maintained when:

  • The isolation switch is connected (isolation switch optional);
  • There is no power connection;
  • Electrically operated and/or rotating parts are protected against restarting (isolation switch);
  • The rotating part has stopped;
  • The components have been cooled down to room temperature.

Note:
Only qualified personnel should perform maintenance on the electrical components. Consider the local regulations! Changes or additions to the device invalidate the declaration of conformity from the manufacturer.

Transport packaging
The transport packaging has been quantitatively reduced to the absolute minimum to transport the quality parts without damage. The material is fully recyclable. The disposal costs are for the recipient of the goods. It is also possible to return the packaging material. The costs for transport of these are for the recipient of the goods. Please note that the packaging may not be contaminated and must be seperated into groups.

Subject to change
The manufacturer is committed to constantly improving its products and reserves the right to make changes in the specifications without prior notice. The technical details are considered correct but do not form the basis for a contract or warranty. All orders are accepted according to the standard terms of our general sales and delivery conditions (available upon request). The information in this document is subject to change without notice. The most recent version of this manual is always available at www.markclimate.com/downloads.

T A B C D E F G H K

MBA
750| 750| 650| 239| 293| 585| 135| 24| 3/4” M| 170
MBA
900| 900| 770| 239| 356| 585| 135| 24| 1” M| 210
T| (kg)
---|---
752| 32,5
753| 33,5
902| 36
903| 37

Installation

Ceiling mounting
Fastening the MBA device to the ceiling must be done with officially approved fasteners. In the dimensioning of the fastening the following unit weights should be taken into account.

Installation procedure:

  1. Mark the distance to the ceiling and drill.
  2. For connection assemble possible required bends.
  3. Mount the MBA device with fasteners (for concrete including consoles)

T   Type
Weight in kg

Louvre adjustment
When adjusting the louvres of the MBA devices the following must be observed:

  • The devices should be mounted at a height of 2.5m to fall outside the danger zone (contact protection).
  • Setting of the louvres must be done when the unit is turned off.
  • All louvres of the MBA devices can be seperately set.

Connecting cables

Do not turn the connector
(This will destroy the heat exchanger. No warranty.)
Attach the heating supply lines to the supply & return of the heat exchanger with a suitable tool. Make use of a gate valve for the heat exchanger so you can easily reach this during later maintenance work.
Remove the protective caps from the connecting lines.
Note: The connection of any bends should be done before the mounting of the device.

  • Connect the discharge and feed as on the photo/drawing.
  • A Return
  • B Flow

When connecting the heater onto the mains use an additional pipe wrench to avoid twisting the pipe.

  • Max. operating pressure 10 Bar
  • Max. water temp. 120 ºC

Air valve and drain valve
When using an air valve, you must make sure that it is mounted at the highest point. Attach the drain valve to the lowest point in the supply line, so a complete emptying is possible.
Blow the drain valve with compressed air to empty it completely.
Note! After loosening the screw (completely), apply sealant to the threads and tighten the screw again.

Connection (correct)
For correct connection, flow line B must be connected to the hot medium and return line A to the cold medium.

  • A Return
  • B Flow

Connection (incorrect)
Connections in upward or downward direction are not possible because of risk of air locks

Electrical diagram

Electrical work may only be done by a qualified installer.

  • An isolator switch must be installed on every device in order to shut off the engine.
  • Only turn on the engines when the outlet and protective louvres have been opened.
  • Connection of engines, switches and other electrical accessories should be done in accordance with the relevant standards (VDE 0100, EMC-act, rules of RU).
  • Ambient temperature up to 40 ºC.
  • Tanner MBA 751/752
  • Multiple Tanner MBA 751/752 with 1 Potentiometer or 0-10Vdc signal
  • Tanner MBA 951/952
  • Multiple Tanner MBA 951/952 with 1 Potentiometer or 0-10Vdc signal

Maintenance

Warranty
Our warranty does not cover damage caused by improper use or maintenance. Moreover, experience shows that with increasing age of the products, lack of maintenance leads to greater damage.
Inspections of the safety equipment should only be performed by trained and qualified personnel! Please contact the service department of your supplier.
Maintenance intervals of the unit The application period for the following items cannot be prescribed. The regular maintenance and cleaning of the device depends only on the degree of soiling. This depends on the degree of dust in the external or ambient air.

Engine
The engine is maintenance-free. Occasionally it should be dried and made dust free.

Heat exchanger
Clean the heat exchanger by blowing compressed air onto it. Take care of oil- containing dust with an oil-soluble detergent. Use a steam cleaner to remove sticky surface.
Note! Use low pressure as well as an intermediate distance to the heat exchanger of at least 300mm.

MARK BV
BENEDEN VERLAAT 87-89 VEENDAM (NEDERLAND) POSTBUS 13, 9640 AA VEENDAM TELEFOON +31(0)598 656600 FAX +31 (0)598 624584
[email protected]
www.mark.nl

MARK EIRE BV
COOLEA, MACROOM
CO. CORK
P12 W660 (IRELAND)
PHONE +353 (0)26 45334
FAX +353 (0)26 45383
[email protected]
www.markeire.com

MARK BELGIUM b.v.b.a.
ENERGIELAAN 12
2950 KAPELLEN
(BELGIË/BELGIQUE) TELEFOON +32 (0)3 6669254
[email protected]
www.markbelgium.be

MARK DEUTSCHLAND GmbH
MAX-PLANCK-STRASSE 16
46446 EMMERICH AM RHEIN
(DEUTSCHLAND)
TELEFON +49 (0)2822 97728-0
TELEFAX +49 (0)2822 97728-10
[email protected]
www.mark.de

MARK POLSKA Sp. z o.o
UL. JASNOGÓRSKA 27
42-202 CZĘSTOCHOWA (POLSKA)
PHONE +48 34 3683443
FAX +48 34 3683553
[email protected]
www.markpolska.pl

S.C. MARK ROMANIA S.R.L.
STR. KOS KAROLY NR. 1 A 540297 TARGU MURES
(ROMANIA)
TEL/FAX +40 (0)265-266.332
[email protected]
www.markromania.ro

Get In Touch
Call: 0845 6880112
Email: [email protected]

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

puravent User Manuals

Related Manuals