VOGELZANG VG1120 Wood Heater Instruction Manual

June 24, 2024
VOGELZANG

VOGELZANG VG1120 Wood Heater

VOGELZANG-VG1120-Wood-Heater-product

Product Specifications

  • Report Number: F19-473
  • Tested Per EPA Methods ASTM E2515, ASTM E3053-ATM, and CSA B415
  • Certified to UL 1482-2022 and CAN/ULC S627:2023
  • Mobile home/transportable buildings approved in USA & Canada
  • Compliance: U.S. Environmental Protection Agency Certified for 2020 particulate emissions standards
  • California Proposition 65 Warning: Contains chemicals known to the State of California to cause harm

Product Usage Instructions

Safety Notice

  • Ensure proper installation to prevent house fires. Follow all installation instructions and contact local officials for guidance.
  • Never leave the product unattended while in operation.

Caution

Read the entire manual before installation or use to avoid property damage or injury. Improper installation will void the warranty.

Installation Checklist

  • Combustible: Yes
  • Colors: Varies
  • Flue Pipe Diameter: Standard size
  • Flue Pipe Type: As specified
  • Minimum Chimney Height: Check local regulations
  • Maximum Log Length: As specified
  • Electrical: Required
  • Dimensions:
    • Overall: Depth x Width x Height
    • Combustion Chamber: Width x Depth
    • Firebox Volume: Cubic Feet
    • Door Opening: Width x Height
    • Pyroceramic Glass Door: (Viewing) Width x Height

Commissioning Checklist

This checklist must be completed by a qualified installer. Failure to follow the manufacturer’s instructions will void the warranty.

Frequently Asked Questions

Q: How should I register my product?

A: You can register your product using the QR code with your smartphone, online at www.usstove.com/support/product- registration, or by downloading the US Stove Company app for iOS and Android.

Q: Where can I find customer service contact information?

A: For customer service, call 1-800-750-2723 Ext 5050, text 423-301-5624, or email customerservice@usstove.com.

Q: Who should install my Wood Stove?

A: Your Wood Stove should be installed by a qualified NFI installer. Find one at www.nficertified.org/public/find-an-nfi- pro/.

  • Report Number: F19-473
  • Tested Per EPA Methods ASTM E2515, ASTM E3053-ATM and CSA B415
  • Certified to UL 1482-2022 and CAN/ULC S627:2023 Mobile home/transportable buildings approved USA & Canada
  • All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.

Save These Instructions In A Safe Place For Future Reference

  • SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For your safety, follow the installation instructions. Never use make-shift compromises during the installation of this heater.
  • Contact local building or fire officials about permits, restrictions, and installation requirements in your area. NEVER OPERATE THIS PRODUCT WHILE UNATTENDED.
  • CAUTION! Please read this entire manual before you install or use your new room heater. Failure to follow instructions may result in property damage, bodily injury, or even death. Improper Installation Will Void Your Warranty!
  • U.S. Environmental Protection Agency Certified to comply with 2020 particulate emissions standards.
  • CALIFORNIA PROPOSITION 65 WARNING: This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects, and/or other reproductive harm.
  • For more information, go to www.P65warnings.ca.gov
  • THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.

INSTALLATION CHECKLIST

  • This manual describes the installation and operation of the Vogelzang, VG1120 wood heater. This heater meets the 2020 U.S. Environmental Protection Agency’s cordwood emission limits for wood heaters sold after May 15, 2020.
  • Under specific test conditions, this heater has been shown to deliver heat at rates ranging from 13,846 to 39,683 Btu/hr with 2.4 g/hr and 66% efficiency.
  • Note: The BTU ratings mentioned above are based on the EPA test protocol under specific test conditions. Our advertised BTUs are based on the first hour of operation at a high burn rate burning dry cordwood.
Combustible: Wood
Colors: Metallic Black
Flue Pipe Diameter: 6” (153 mm)
Flue Pipe Type: Black or Blued Steel 2100°F (650°C)
Minimum Chimney Height: 12’ (3.7 m)
Maximum Log Length: 18” (458 mm)
Electrical: 120VAC, 0.55A, 60Hz

Dimensions
 | MODEL| DEPTH| WIDTH| HEIGHT
Overall: Depth x Width x Height:| VG1120 (Leg)| 21.1” (536 mm)| 22.5” (572 mm)| 30.8” (783 mm)
VG1120 (Pedestal)| 21.2” (539 mm)| 22.5” (572 mm)| 31.7” (806 mm)
Combustion Chamber: Width x Depth:| 18.29” x 11” (465 mm X 280 mm)
Firebox Volume: Cubic Feet:| 1.31 cubic feet
Door Opening: Width x Height:| 15.98” x 8.54” (406 mm X 217 mm)
Pyroceramic Glass Door: (Viewing) Width x Height:| 14.37” x 7.76” (365 mm X 198 mm)

CAUTIONS:

  • HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS.
  • DO NOT USE CHEMICALS OR FLUIDS TO IGNITE THE FIRE.
  • DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED.
  • DO NOT BURN GARBAGE, OR FLAMMABLE FLUID SUCH AS GASOLINE, NAPHTHA, OR MOTOR OIL.
  • DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
  • ALWAYS CLOSE THE DOOR AFTER THE IGNITION.
  • Note: Register your product by using your smart phone with the QR code. Save your receipts with your records for any warranty claims.
  • You can also register your product online at www.usstove.com/support/product-registration / OR by downloading the US Stove Company app available for iOS and Android.
  • Your Wood Stove should be installed by a qualified installer only. An NFI-qualified Installer can be found at www.nficertified.org/public/find-an-nfi-pro/

CUSTOMER SERVICE

COMMISSIONING CHECKLIST

  • This Checklist is to be completed in full by the qualified person who installs this unit. Keep this page for future reference.
  • Failure to install and commission according to the manufacturer’s instructions and complete this checklist will invalidate the warranty.

Please Print

Customer Name: Telephone Number:

Address:
Model:
Serial Number:|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | |  |  |  |  |
Installation Company Name:| Phone Number:
Installation Technician’s Name:| License Number:

DESCRIPTION OF WORK

  • Location of installed appliance: _____
  • Chimney System: New Chimney System Yes No If yes, Brand ____
  • If no, Date of inspection of the existing chimney system: __

COMMISSIONING

  • Confirm Hearth Pad Installation as per Installation Instructions ………………………………………………………………………………
  • Confirm proper placement of internal parts …………………………………………………………………………………………………………….
  • Check soundness of door gasket and door seals.. ………………………………………………………………………………………………….
  • Confirm clearances to combustibles as per installation instructions in this manual ………………………………………………….
  • Check the operations of the air controls… ………………………………………………………………………………………………………………
  • Confirm all flue pipe and chimney system are secure and sealed. ……………………………………………………………………………
  • Confirm the stove properly drafts when fired. ………………………………………………………………………………………………………….
  • Check to ensure a CO alarm is installed as per local building codes and is functional ……………………………………………….
  • Explain the safe operation, proper fuel usage, cleaning, and routine maintenance requirements. ……………………………….
  • Declaration of Completion: As the qualified person responsible for the work described above, I confirm that the appliance as associated work has been installed as per the manufacturer’s instructions and following any applicable building and installation codes.
  • Signed: ____
  • Print Name: ____
  • Date: ____
  • Home Owner: RETAIN THIS INFORMATION FOR FUTURE REFERENCE

ASSEMBLY INSTRUCTIONS

FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050

TOOLS AND MATERIALS

  • You will need a drill with a 1/8” bit to install sheet metal screws into the connector pipe. A 5/16” socket/wrench or screwdriver to install the room air deflector, and blower assembly described. A 1/2” socket/wrench to install the flue collar.
  • A non-combustible floor protector as specified in this manual. All chimney and chimney connector components are required for your particular chimney installation.
  • For mobile home/transportable buildings see the “For Use In Mobile Home/Transportable Buildings” section of this manual.

BLOWER ASSEMBLY

  • The blower assembly must be disconnected from the source of the electrical supply before attempting the installation.
  • The blower assembly is intended for use only with a stove that is marked to indicate such use. Do not route the supply cord near or across hot surfaces! Fix the assembly to the back of the stove with the four screws provided.

ASH PAN ASSEMBLY

  • Remove the ash pan from the firebox. Under the firebox, there are two brackets; Slide the ash pan into these brackets.VOGELZANG-VG1120-Wood-Heater-fig-3

FLUE COLLAR ASSEMBLY

  • Mount the flue collar to the top of the unit as shown using the (3) 5/16-18 x 1-1/2 bolts, (3) washers, and (3) weld tabs provided in the parts box.

FIREBRICK CONFIGURATION

  • Replace the Firebrick as shown in the illustration.

AIR DEFLECTOR ASSEMBLY

  • Use the provided screws to attach the air deflector to the rear of the unit.

INSTALLATION

SAFETY NOTICE

  • IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS.
  • CONSULT YOUR MUNICIPAL BUILDING DEPARTMENT OR FIRE OFFICIALS ABOUT PERMITS, RESTRICTIONS, AND INSTALLATION REQUIREMENTS IN YOUR AREA.
  • USE SMOKE DETECTORS IN THE ROOM WHERE YOUR STOVE IS INSTALLED.
  • KEEP FURNITURE AND DRAPES WELL AWAY FROM THE STOVE.
  • NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR SIMILAR LIQUIDS TO START OR “FRESHEN UP” A FIRE IN THIS HEATER.
  • KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IT IS IN USE.
  • IN THE EVENT OF A CHIMNEY FIRE, PUSH THE AIR CONTROL FULL CLOSED TO DEPRIVE THE FIRE OF OXYGEN. CALL THE FIRE DEPARTMENT.
  • DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
  • A SOURCE OF FRESH AIR IN THE ROOM OR SPACE HEATED SHALL BE PROVIDED WHEN REQUIRED.
  • THIS ROOM HEATER SHALL NOT BE INSTALLED IN A FACTORY-BUILT FIREPLACE.
  • We recommend that our woodburning hearth products be installed and serviced by professionals who are certified in the U.S by the National Fireplace Institute® (NFI) as NFI Woodburning Specialists or who are certified in Canada by Wood Energy Technical Training (WETT).
  • Your heater should be installed by a qualified NFI (US) or WETT (Canada) technician.

To find the nearest qualified installer, go to:

POSITIONING THE STOVE

  • It is very important to position the wood stove as close as possible to the chimney, and in an area that will favor the most efficient heat distribution possible throughout the house.
  • The stove must therefore be installed in the room where the most time is spent and in the most spacious room possible. Recall that wood stoves produce radiating heat, the heat we feel when we are close to a wood stove.
  • A wood stove also functions by convection, that is through the displacement of hot air accelerated upwards and its replacement with cooler air. If necessary, the hot air distribution from the stove may be facilitated by the installation of a blower.
  • The wood stove must not be hooked up to a hot air distribution system since an excessive accumulation of heat may occur.
  • A wood stove must never be installed in a hallway or near a staircase, since it may block the way in case of fire or fail to respect required clearances.

FOR CUSTOMER SERVICE CALL:800-750-2723 EXT 5050 FLOOR PROTECTOR

  • This heater must have a non-combustible floor protector (ember protection) installed beneath it if the floor is of combustible material. If a floor pad is used, it should be UL-listed or equal.
  • The floor pad or non-combustible surface should be large enough to extend under the stove and beyond each side as indicated.
  • If there is a horizontal run of the flue pipe, there needs to be floor protection under it that extends two inches beyond either side of the pipe.
Front *16” (407 mm)
Sides 8” (204 mm)
Rear 2” (51 mm)

*Canadian Installations require 18” (457 mm)

CLEARANCES TO COMBUSTIBLES

  • It is of utmost importance that the clearances to combustible materials be strictly adhered to during the installation of the stove.
  • Do not place any combustible material within 4’ (1.2m) of the front of the unit.
  • The clearance between the flue pipe and a wall is valid only for vertical walls and for vertical flue pipes.
  • The chimney connector must not pass through an attic or roof space, closet, or similar concealed space, a floor, or a ceiling.
  • For Canadian installations, where passage through a wall, or partition of combustible construction is desired, the installation must conform to CAN/ULC-S629.
  • A flue pipe crossing a combustible wall must have a minimum clearance of 18” (457.2 mm).
  • To reduce flue clearances from combustible materials, contact your local safety department.
  • Floor-to-ceiling height must be at least 7’ (2.13m).
Key in mm
A 17 432
B 21 534
C 20 508
D 29 737
E 14 356
F 22 559
G 7 ft 2.13m

OUTSIDE COMBUSTION AIR

  • Your wood stove is approved to be installed with an outside air intake (4FAK) which is necessary for a mobile home/transportable building. This type of installation is also required in air-tight houses and houses with negative pressure problems.
  • You can purchase this option through your heater dealer. Make sure to specify the part number mentioned in this booklet. Installation instructions are supplied with the air intake kit.

Outside combustion air may be required if:

  1. Your stove does not draw steadily, smoke roll-out occurs, wood burns poorly, or back-drafts occur whether or not there is combustion present.
  2. Existing fuel-fired equipment in the house, such as fireplaces or other heating appliances, smells, does not operate properly, suffers smoke roll-out when opened, or back-drafts occur whether or not there is combustion present.
  3. Opening a window slightly on a calm (windless) day alleviates any of the above symptoms.
  4. The house is equipped with a well-sealed vapor barrier and tight-fitting windows and/or has any powered devices that exhaust house air.
  5. There is excessive condensation on windows in the winter.
  6. A ventilation system is installed in the house.
    • Slide the hose clamp over the aluminum flex pipe. Then slide the flex pipe over the air intake tube of the stove. Next, tighten the hose clamp over the end of the aluminum flex hose.

FOR USE IN MOBILE HOME/TRANSPORTABLE BUILDINGS

  • WARNING! DO NOT INSTALL IN THE SLEEPING ROOM.
  • CAUTION! THE STRUCTURAL INTEGRITY OF THE MOBILE HOME/TRANSPORTABLE BUILDING FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED.
  • USE A FACTORY-BUILT CHIMNEY THAT COMPLIES WITH UL 103 STANDARDS; THEREFORE IT MUST BE A TYPE HT (2100°F).
  • USE A SPARK ARRESTER.
  • THE STOVE MUST BE ATTACHED TO THE STRUCTURE OF THE MOBILE HOME/TRANSPORTABLE BUILDING.

SECURING APPLIANCE’S ON A PEDESTAL TO THE FLOOR

  • Use the designated holes to secure the unit to the floor.

SECURING APPLIANCE’S WITH LEGS TO THE FLOOR

  1. The bracket engages around the square extrusion of the leveling bolt inserted into the leg.
  2. Once the appliance is leveled, position the bracket and attach it to the floor using the appropriate hardware needed for your specific flooring.
  3. Install one bracket per leg or consult your local authority having jurisdiction to determine how many points of attachment are required.
  • In addition to the previously detailed installation requirements, mobile home/transportable building installations must meet the following requirements.
  • The space heater is to be connected to a factory-built chimney conforming to CAN/ULC-S629, Standard for 650°C Factory-Built Chimneys.
  • The heater must be permanently attached to the floor. There are two holes in the pedestal base, use 3/8” bolts through the floor.
  • The heater must be electrically grounded to the steel chassis of the mobile home/transportable building with 8 GA copper wire using a serrated or star washer to penetrate paint or protective coating to ensure grounding.
  • When moving your mobile home/transportable building, all exterior venting must be removed while the mobile home/transportable building is being relocated. After relocation, all venting must be reinstalled and securely fastened.
  • Outside Air is mandatory for mobile home/transportable building installation. See your dealer for purchasing.
  • Check with your local building officials as other codes may apply.
  • Only use the specified components listed in this manual for this unit. The use of components that are not meant for this unit can cause unsafe conditions.

CHIMNEY CONNECTOR (STOVE PIPE)

  • The chimney connector and chimney must have the same diameter as the stove outlet (6”). If this is not the case, we recommend you contact your dealer to ensure there will be no problem with the draft.
  • The stovepipe must be made of aluminized or cold roll steel and have a minimum thickness of 0.021” or 0.53 mm. It is strictly forbidden to use galvanized steel.
  • The smoke pipe should be assembled to promote the male section (crimped end) of the pipe to be faced down.
  • Attach each section to another with three metal screws spaced an equal distance apart. The pipe must be short and straight. All sections installed horizontally must slope at least 1/4 inch per foot, with the upper end of the section toward the chimney.
  • Any installation with a horizontal run of chimney pipe must conform to NFPA 211. To ensure a good draft, the total length of the coupling pipe should never exceed 8’ to 10’ (2.4m to 3.04m).
  • Except for cases of vertical installation, in a cathedral-roof style where the smoke exhaust system can be much longer and connected without problem to the chimney at the ceiling of the room.
  • There should never be more than two 90-degree elbows in the smoke exhaust system.
  • The installation of a “barometric draft stabilizer” (fireplace register) on a smoke exhaust system is prohibited. Furthermore, the installation of a draft damper is not recommended.
  • With a controlled combustion wood stove, the draft is regulated upon intake of the combustion air in the stove and not at the exhaust.

IMPORTANCE OF PROPER DRAFT

  • A draft is a force that moves air from the appliance up through the chimney. The amount of draft in your chimney depends on the length of the chimney, local geography, nearby obstructions, and other factors.
  • Too much draft may cause excessive temperatures in the appliance. An inadequate draft may cause back-puffing into the room and “plugging” of the chimney.
  • An inadequate draft will cause the appliance to leak smoke into the room through the appliance and chimney connector joints. An uncontrollable burn or excessive temperature indicates an excessive draft.

CHIMNEY

  • Your wood stove may be hooked up with a 6” factory-built or masonry chimney. If you are using a factory-built chimney, it must comply with UL 103 or CAN/ULC-S629 standards; therefore it must be a Type HT (2100°F). It must be installed according to the manufacturer’s specifications. Take into account the chimney’s location to ensure it is not too close to neighbors or in a valley which may cause unhealthy or nuisance conditions.
  • If you are using a masonry chimney, it must be built in compliance with the specifications of the National Building Code. It must be lined with firebricks, metal, or clay tiles sealed together with fire cement. Round flues are the most efficient.
  • The interior diameter of the chimney flue must be identical to the stove smoke exhaust. A flue that is too small may cause draft problems, while a large flue favors rapid cooling of the gas, hence the build-up of creosote and the risk of chimney fires.
  • Note that it is the chimney and not the stove that creates the draft effect; your stove’s performance is directly dependent on an adequate draft from your chimney. Do not connect this unit to a chimney flue serving another appliance.

The following recommendations may be useful for the installation of your chimney:

  1. It must rise above the roof at least 3’ (0.9m) from the uppermost point of contact.
  2. The chimney must exceed any part of the building or other obstruction within a 10’ (3.04m) distance by a height of 2’ (0.6m).
  3. The installation of an interior chimney is always preferable to an exterior chimney. Indeed, the interior chimney will, by definition, be hotter than an exterior chimney, being heated up by the ambient air in the house. Therefore the gas that circulates will cool more slowly, thus reducing the build-up of creosote and the risk of chimney fires.
  4. The draft caused by the tendency for hot air to rise will be increased with an interior chimney.
  5. Using a fire screen at the extremity of the chimney requires regular inspection to ensure that it is not obstructed thus blocking the draft, and it should be cleaned when used regularly.

FACTORY-BUILT CHIMNEY

When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be followed. You must also purchase (from the same manufacturer) and install the ceiling support package or wall pass-through and “T” section package, firestops (where needed), insulation shield, roof flashing, chimney cap, etc. Maintain proper clearance of the structure as recommended by the manufacturer. The chimney must be the required height above the roof or other obstructions for safety and proper draft operation .VOGELZANG-VG1120-Wood-Heater-fig-14

MASONRY CHIMNEY

  • Ensure that a masonry chimney meets the minimum standards of the National Fire Protection Association (NFPA) by having it inspected by a professional. Make sure there are no cracks, loose mortar, or other signs of deterioration and blockage.
  • Be sure to have the chimney cleaned before the stove is installed and operated. When connecting the stove through a combustible wall to a masonry chimney, special methods are needed.VOGELZANG-VG1120-Wood-Heater-fig-15

COMBUSTIBLE WALL CHIMNEY CONNECTOR PASS-THROUGHS

  • METHOD A – 12” (304.8 mm) Clearance to Combustible Wall Member: Using a minimum thickness of 3.5” (89 mm) brick and a 5/8” (15.9 mm) minimum wall thickness clay liner, construct a wall pass-through.
  • The clay liner must conform to ASTM C315 (Standard Specification for Clay Fire Linings) or its equivalent. Keep a minimum of 12” (304.8 mm) of brick masonry between the clay liner and wall combustibles.
  • The clay liner shall run from the brick masonry outer surface to the inner surface of the chimney flue liner but not past the inner surface. Firmly grout or cement the clay liner in place to the chimney flue liner.
  • METHOD B – 9” (228.6 mm) Clearance to Combustible Wall Member: Using a 6” (152.4 mm) inside diameter, listed, factory-built Solid-Pak chimney section with insulation of 1” (25.4 mm) or more, build a wall pass-through with a minimum 9” (228.6 mm) air space between the outer wall of the chimney length and wall combustibles. Use sheet metal supports fastened securely to wall surfaces on all sides, to maintain the 9” (228.6 mm) air space.
  • When fastening supports to chimney length, do not penetrate the chimney liner (the inside wall of the Solid-Pak chimney).
  • The inner end of the Solid-Pak chimney section shall be flush with the inside of the masonry chimney flue, and sealed with a non-water soluble refractory cement.
  • Use this cement to also seal the brick masonry penetration.
  • METHOD C – 6” (152.4 mm) Clearance to Combustible Wall Member: Starting with a minimum 24 gage (.024” [.61 mm]) 6” (152.4 mm) metal chimney connector, and a minimum 24 gage ventilated wall thimble which has two air channels of 1” (25.4 mm) each, construct a wall pass-through. There shall be a minimum 6” (152.4 mm) separation area containing fiberglass insulation, from the outer surface of the wall thimble to wall combustibles.
  • Support the wall thimble, and cover its opening with a 24-gage minimum sheet metal support. Maintain the 6” (152.4 mm) space. There should also be a support sized to fit and hold the metal chimney connector.
  • See that the supports are fastened securely to wall surfaces on all sides. Make sure the fasteners used to secure the metal chimney connector do not penetrate the chimney flue liner.
  • METHOD D – 2” (50.8 mm) Clearance to Combustible Wall Member: Start with a solid-pak listed factory-built chimney section at least 12” (304 mm) long, with insulation of 1” (25.4 mm) or more, and an inside diameter of 8” (2 inches [51 mm] larger than the 6” [152.4 mm] chimney connector). Use this as a pass-through for a minimum 24-gauge single wall steel chimney connector. Keep solid-pak section concentric with and spaced 1” (25.4 mm) off the chimney connector by way of sheet metal support plates at both ends of the chimney section. Cover opening with and support chimney section on both sides with 24 gauge minimum sheet metal supports.
  • See that the supports are fastened securely to wall surfaces on all sides. Make sure the fasteners used to secure the chimney flue line do not penetrate the inner liner.

NOTES:

  • Connectors to a masonry chimney, excepting method B, shall extend in one continuous section through the wall pass-through system and the chimney wall, to but not past the inner flue liner face.
  • A chimney connector shall not pass through an attic or roof space, closet or similar concealed space, or a floor, or ceiling.

OPERATION INSTRUCTIONS

NEVER OPERATE THIS PRODUCT WHILE UNATTENDED

  • CAUTIONS: HOUSE FIRE HAZARDS
  • DO NOT STORE WOOD ON THE FLOOR PROTECTOR, UNDERNEATH STOVEPIPE(S), OR ANYWHERE WITHIN CLEARANCES TO COMBUSTIBLE SURFACES SPECIFIED FOR THIS APPLIANCE.
  • NEVER OPERATE WITH SECONDARY TUBES, FIBERBOARD, OR INSULATION REMOVED.

OPERATING SAFETY PRECAUTIONS

  • NEVER OVERFIRE THIS APPLIANCE BY BUILDING EXCESSIVELY HOT FIRES AS A HOUSE/BUILDING FIRE MAY RESULT. YOU ARE OVERFIRING THE APPLIANCE IF IT BEGINS TO GLOW OR TURN RED.
  • NEVER BUILD EXCESSIVELY LARGE FIRES IN THIS TYPE OF APPLIANCE AS DAMAGE TO THE FIREBOX OR SMOKE LEAKAGE MAY RESULT.
  • DO NOT BUILD FIRE TOO CLOSE TO THE GLASS.
  • HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING, AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. DO NOT TOUCH THE APPLIANCE UNTIL IT HAS COOLED.
  • PROVIDE ADEQUATE AIR FOR COMBUSTION TO THE ROOM WHERE THE APPLIANCE IS INSTALLED.
  • INSPECT CHIMNEY LINER EVERY 60 DAYS. REPLACE LINER IMMEDIATELY IF IT IS RUSTING OR LEAKING SMOKE INTO THE ROOM.
  • ATTEMPTS TO ACHIEVE HEAT OUTPUT RATES THAT EXCEED HEATER DESIGN SPECIFICATIONS CAN RESULT IN PERMANENT DAMAGE TO THE HEATER.
  • WARNING: EXPLOSION HAZARD
  • NEVER USE CHEMICALS, GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR SIMILAR FLAMMABLE LIQUIDS TO START OR “FRESHEN UP” A FIRE IN THE APPLIANCE.
  • KEEP ALL FLAMMABLE LIQUIDS, ESPECIALLY GASOLINE, OUT OF THE VICINITY OF THE APPLIANCE – WHETHER IN USE OR STORAGE.

WOOD STOVE UTILIZATION

  • Your heating appliance was designed to seasoned burn natural wood only; no other materials should be burned.
  • Any type of well-seasoned natural wood may be used in your stove, but specific varieties have better energy yields than others. Higher efficiencies and lower emissions generally result when burning air-dried seasoned hardwoods, as compared to softwoods or too green or freshly cut hardwoods. The following resources can assist in learning the burn characteristics of various species of wood: http://firewoodresource.com/firewood-btu-ratings/; or
  • https://forestry.usu.edu/forest-products/wood-heating. The operation of this wood heater in a manner inconsistent with the owner’s manual will void your warranty and is also against federal regulations.
  • Waste and other flammable materials should not be burned in your stove.

DO NOT BURN:

  1. Garbage;
  2. Lawn clippings or yard waste;
  3. Materials containing rubber, including tires;
  4. Materials containing plastic;
  5. Waste petroleum products, paints or paint thinners, or asphalt products;
  6. Materials containing asbestos;
  7. Construction or demolition debris;
  8. Railroad ties or pressure-treated wood;
  9. Manure or animal remains;
  10. Saltwater driftwood or other previously saltwater-saturated materials;
  11. Unseasoned wood;
  12. Paper products, cardboard, plywood, or particleboard. The prohibition against burning these materials does not prohibit the use of fire starters made from paper, cardboard, sawdust, wax, and similar substances to start a fire in an affected wood heater.
  • Burning these materials may result in the release of toxic fumes or render the heater ineffective and cause smoke. Deadwood lying on the forest floor should be considered wet and requires full seasoning time.
  • Standing deadwood can usually be considered to be about 2/3 seasoned. Smaller pieces of wood will dry faster. All logs exceeding 6” in diameter should be split.
  • The wood should not be stored directly on the ground. Air should circulate through the logs.
  • A 24” to 48” air space should be left between each row of logs, which should be placed in the sunniest location possible. The upper layer of wood should be protected from the elements but not the sides.
  • A good indicator of if the wood is ready to burn is to check the piece’s ends.
  • If cracks are radiating in all directions from the center then the wood should be dry enough to burn. If your wood sizzles in the fire, even though the surface is dry, it may not be fully cured and should be seasoned longer.
  • You must use DRY WOOD only in your wood stove. The wood should have dried for 9 to 15 months, such that the humidity content (in weight) is reduced below 20% of the weight of the log. It is very important to keep in mind that even if the wood has been cut for one, two, or even more years, it is not necessarily dry if it has been stored in poor conditions. Under extreme conditions, it may rot instead of drying.
  • This point cannot be overstressed; the vast majority of the problems related to the operation of a wood stove are caused by the fact that the wood used was too damp or had dried in poor conditions.
  • These problems can be:
  • ignition problems
  • creosote build-up causing chimney fires
  • low energy yield
  • blackened windows
  • incomplete log combustion
  • Do not burn manufactured logs made of wax-impregnated sawdust or logs with any chemical additives.

TESTING YOUR WOOD

  • When the stove is thoroughly warmed, place one piece of split wood (about five inches in diameter) parallel to the door on the bed of red embers.
  • Keep the air control fully open and close the door. If the wood ignites within 90 seconds from the time it was placed in the stove, your wood is correctly dried. If ignition takes longer, your wood is damp.
  • If your wood hisses and water or vapor escapes at the ends of the piece, your wood is soaked or freshly cut (green). Do not use this wood in your stove.
  • Large amounts of creosote could be deposited in your chimney, creating potential conditions for a chimney fire.

TAMPER WARNING

  • This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual.

EFFICIENCIES

  • Efficiencies can be based on either the lower heating value (LHV) or the higher heating value (HHV) of the fuel. The lower heating value is when water leaves the combustion process as a vapor, in the case of woodstoves the moisture in the wood being burned leaves the stove as a vapor. The higher heating value is when water leaves the combustion process completely condensed. In the case of woodstoves, this would assume the exhaust gases are at room temperature when leaving the system, and therefore calculations using this heating value consider the heat going up the chimney as lost energy. Therefore, the efficiency calculated using the lower heating value of wood will be higher than the efficiency calculated using the higher heating value. The best way to achieve optimum efficiencies is to learn the burn characteristics of your appliance and burn well-seasoned wood. Higher burn rates are not always the best heating burn rates; after a good fire is established a lower burn rate may be a better option for efficient heating. A lower burn rate slows the flow of usable heat out of the home through the chimney, and it also consumes less wood.

  • NOTICE – INITIAL BURNS TO CURE PAINT BECAUSE OF THE HIGH OPERATING TEMPERATURES, THIS APPLIANCE IS COATED WITH A SPECIAL TEMP PAINT WHICH REQUIRES A SERIES OF LOW TO MEDIUM BURNS TO FULLY CURE FOR DURABILITY AND A LIFETIME OF SERVICE.

  • Proper curing of the high-temp paint requires a series of three initial burns. The appliance should be allowed to cool off between each burn. The first two burns should be small fires and low temperatures (250°F) for 20 minutes each. The third fire should be at a temperature of approximately 500°F for 20 minutes. Provide adequate cross-ventilation to clear any smoke or odor caused by initial firings.
    Notice: Use solid wood fuel only! Do not burn garbage or flammable fluids. Do not use coal. This appliance is not designed to accommodate the airflow (draft) required to properly burn coal or coal products.

  • Do not elevate the fire using grates or irons. Build the fire directly on the firebrick.

FUELING INSTRUCTIONS

  • CAUTION: THE DOOR IS HOT DURING OPERATION. AVOID CONTACT WITH HEATED SURFACES DURING OPERATION.
  • This wood stove has been certified by the US EPA to meet strict 2020 guidelines. To ensure this unit produces the optimal minimum emissions only well-seasoned cordwood must be burned.
  • Burning unseasoned wet wood only hurts the efficiency of your stove and leads to accelerated creosote buildup in your chimney. Be considerate of the environment and only burn dry wood.
  • CAUTION: DO NOT LEAVE THE APPLIANCE UNATTENDED THE WITH DOOR OPEN.
  • For a cold start-up, place 4 to 5 pieces of newspaper into the firebox. On top of the newspaper, lay 2.5 lbs of kindling in random placement to ensure airflow through the kindling.
  • On top of the kindling, place approximately 3.5 to 4 lbs of small pieces of cordwood.
  • NOTE: Use smaller pieces of wood during start-up and a high burn rate to increase the stove temperature.
  • Pull the air control out fully (in the “HI” position). Light the newspaper and leave the door slightly open for about a minute.
  • NOTE: You may have to leave it open a bit longer, depending on your chimney height and outdoor conditions. After one minute (or once the fire is well started) close the door and allow the kindling to ignite.
  • Once the kindling has burned down to a starter coal bed, load the unit with approximately 14 lbs of fuel for the first high-burn load.
  • After the first high burn load and the stove is well warmed up, adjust the unit as needed for a medium or low burn setting.
  • For a medium burn, once the high-burn fuel load is burned down to an established coal bed, load the unit with 16 lbs of cordwood and close the door immediately. Leave the air control fully open (in the “HI” position) for 5 minutes.
  • After 5 minutes, the air control can be put in the medium setting to about 50% of the slide rod, between low and high settings.
  • For a low-fire burn setting, follow the same procedure as a medium burn for loading and initial ignition. After 5 minutes of burning, slowly move the air slide to the medium setting (50% closed).
  • After 3-4 minutes, set the air inlet to the minimum (lowest setting). The air slide rod should be pushed in.
  • Note: The closing down procedure should take about 10 minutes.
  • Closing down the air too quickly will cause the stove to smoke.

WARNINGS:

  • NEVER OVERFIRE YOUR STOVE. IF ANY PART OF THE STOVE STARTS TO GLOW RED, OVERFIRING IS HAPPENING. READJUST THE AIR INTAKE CONTROL AT A LOWER SETTING.
  • THE INSTALLATION OF A LOG CRADLE OR GRATES IS NOT RECOMMENDED IN YOUR WOOD STOVE. BUILD FIRE DIRECTLY ON FIREBRICK.
  • NEVER PUT WOOD ABOVE THE FIREBRICK LINING OF THE FIREBOX.
  • ATTEMPTS TO ACHIEVE HEAT OUTPUT RATES THAT EXCEED HEATER DESIGN SPECIFICATIONS CAN RESULT IN PERMANENT DAMAGE TO THE HEATER.

VISIBLE SMOKE

  • The amount of visible smoke being produced can be an effective method of determining how efficiently the combustion process is taking place in the given settings.
  • Visible smoke consists of unburned fuel and moisture leaving your stove. Learn to adjust the air settings of your specific unit to produce the smallest amount of visible smoke.
  • Wood that has not been seasoned properly and has a high wood moisture content will produce excess visible smoke and burn poorly.

AIR TUBES

  • The air tubes assembled in this unit are designed to provide an accurate mix of secondary air to ensure the highest efficiency.
  • Any damage or deterioration of these tubes may reduce the efficiency of combustion.
  • The air tubes are held in position by screws or snap pins. Locate these to either side of the tube and remove them to allow the tube to be removed and replaced.

BLOWER OPERATION

  • The variable-speed blower circulates air warmed by the firebox into the living area to distribute the heat more evenly. The blower control knob is located on the side of the blower housing.
  • Turn the knob clockwise to turn the blower on. The speed is controlled by turning the knob clockwise for slower speeds and counter-clockwise for faster speeds. To turn the blower off, turn the speed control knob fully counter-clockwise.
  • It is recommended to turn the blower off when the unit is not in operation. The blower should be removed at the beginning of every “burn” season and air-blown clean, removing any dust or build-up.

CHIMNEY MAINTENANCE

NEVER OPERATE THIS PRODUCT WHILE UNATTENDED

  • CAUTION: DO NOT OVERFIRE APPLIANCE. YOU ARE OVERFIRING IF ANY PART OF THE APPLIANCE GLOWS RED.
  • CLOSE THE DOOR AND SHUT THE DAMPER IMMEDIATELY TO REDUCE THE AIR SUPPLY AND SLOW DOWN THE FIRE.
  • CAUTION: SLOW-BURNING FIRES FOR EXTENDED USE OR BURNING GREEN WOOD MAY CAUSE EXCESSIVE CREOSOTE BUILD-UP.
  • IGNITION OF CREOSOTE OR OVERFIRING COULD CAUSE A CHIMNEY FIRE. CHIMNEY FIRES BURN EXTREMELY HOT AND MAY IGNITE SURROUNDING COMBUSTIBLE MATERIALS.
  • IN CASE OF A CHIMNEY FIRE, CALL THE FIRE DEPARTMENT IMMEDIATELY!

CREOSOTE FORMATION AND NEED FOR REMOVAL

  • When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire.
  • As a result, creosote residue accumulates on the flue lining. When ignited this creosote makes an extremely high-temper fire.
  • The chimney connector and chimney should be inspected at least once every two months during the heating season to determine if a creosote build-up has occurred.
  • If creosote has accumulated (3 mm or more), it should be removed to reduce the risk of a chimney fire. We strongly recommend that you install a magnetic thermometer on your smoke exhaust pipe, approximately 18” above the stove.
  • This thermometer will indicate the temperature of your gas exhaust fumes within the smoke exhaust system. The ideal temperature for these gases is somewhere between 275°F and 500°F. Below these temperatures, the build-up of creosote is promoted.
  • Above 500°F, heat is wasted since a too large quantity is lost into the atmosphere.

TO PREVENT CREOSOTE BUILD-UP

  • Always burn dry wood. This allows clean burns and higher chimney temperatures, therefore less creosote deposit.
  • Leave the air control fully open for about 5 min. every time you reload the stove to bring it back to proper operating temperatures.
  • The secondary combustion can only take place if the firebox is hot enough.
  • Always check for a creosote deposit once every two months and have your chimney cleaned at least once a year.
  • If a chimney or creosote fire occurs, close all dampers immediately. Wait for the fire to go out and the heater to cool, then inspect the chimney for damage.
  • If no damage results, perform a chimney cleaning to ensure no more creosote deposits is remaining in the chimney.
  • CAUTION: A CHIMNEY FIRE MAY CAUSE IGNITION OF WALL STUDS OR RAFTERS WHICH WERE ASSUMED TO BE A SAFE DISTANCE AWAY FROM THE CHIMNEY.
  • IF A CHIMNEY FIRE OCCURS, HAVE YOUR CHIMNEY INSPECTED BY A QUALIFIED EXPERT BEFORE USING AGAIN.

ASH REMOVAL & DISPOSAL

  • Whenever ashes get 3 to 4 inches deep in your firebox or ash pan, and when the fire has burned down and cooled, remove excess ashes. Leave an ash bed approximately 1 inch deep on the firebox bottom to help maintain a hot charcoal bed.
  • Ashes should be placed in a metal container with a tight-fitting lid. The closed container of ashes should be placed on a non-combustible floor or the ground, away from all combustible materials, pending final disposal.
  • The ashes should be retained in the closed container until all cinders have thoroughly cooled.
  • ASHES COULD CONTAIN HOT EMBERS EVEN AFTER TWO DAYS WITHOUT OPERATING THE STOVE.
  • THE ASH PAN CAN BECOME VERY HOT. WEAR GLOVES TO PREVENT INJURY.
  • NEVER BURN THE STOVE WITH THE ASH TRAP OPEN. THIS WOULD RESULT IN OVERFIRING THE STOVE. DAMAGE TO THE STOVE AND EVEN HOUSE FIRE MAY RESULT.

SMOKE & CO MONITORS

  • Burning wood naturally produces smoke and carbon monoxide(CO) emissions. CO is a poisonous gas when exposed to elevated concentrations for extended periods. While the modern combustion systems in heaters drastically reduce the amount of CO emitted out the chimney, exposure to the gases in closed or confined areas can be dangerous. Make sure your stove gaskets and chimney joints are in good working order and sealing properly to ensure unintended exposure. It is recommended that you use both smoke and CO monitors in areas having the potential to generate CO.

GLASS CARE

  • Inspect and clean the glass regularly to detect any cracks. If you spot one, turn the stove off immediately. Do not abuse the glass door by striking or slamming shut. Do not use the stove if the glass is broken.
  • If the glass on your stove breaks, replace it only with the glass supplied by your heater dealer. Never substitute other materials for the glass.
  • To replace the glass, remove the screws retaining the glass moldings inside the door. Remove the moldings and replace the damaged piece with a new one. Perform the procedure backward after replacing it. When replacing the glass, you should change the glass gasket to make sure you keep it sealed.
  • Never wash the glass with a product that may scratch. Use a specialized product, available in the stores where wood stoves are sold. The glass should be washed only when cold.

GASKET CARE

  • NEVER OPERATE THE STOVE WITHOUT THE GASKET OR WITH A DAMAGED OR BROKEN GASKET. OPERATING WITHOUT A GASKET OR DAMAGED GASKET WILL RESULT IN DAMAGE TO YOUR STOVE AND CAN RESULT IN A HOUSE FIRE.
  • This unit’s door uses a 1” diameter rope gasket. It is recommended that you change the door gasket (which makes your stove door airtight) once a year, to ensure good control over the combustion, maximum efficiency, and security.
  • To change the door gasket, simply remove the damaged one. Carefully clean the available gasket groove, apply a high-temperature silicone sold for this purpose, and install the new gasket. You may light up your stove again approximately 24 hours after having completed this operation.
  • THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION.
  • IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH OPERATING INSTRUCTIONS IN THIS MANUAL.

WIRING DIAGRAM

OPTIONAL CB36 BLOWER WIRING DIAGRAM

  • DANGER: SHOCK HAZARD DISCONNECT POWER SOURCE BEFORE INSTALLATION AND WHENEVER SERVICING BLOWER ASSEMBLY.
  • CAUTION: MOVING PARTS CAN CAUSE INJURY. DO NOT OPERATE WITH COVER REMOVED.VOGELZANG-VG1120-Wood-Heater-fig-23
  • NOTICE: ANY REPLACEMENT WIRING MUST HAVE EQUIVALENT INSULATION AND TEMPERATURE RATING (105° C).
  • NOTICE: DO NOT ALLOW THE POWER CORD TO TOUCH HOT SURFACES! KEEP THE POWER CORD AT LEAST 12”/30.5 CM FROM THE STOVE OR PIPE SURFACES.

HOW TO ORDER REPAIR PARTS

FOR PARTS ASSISTANCE, CALL 800-750-2723 EXT 5051 OR EMAIL: PARTS@USSTOVE.COM, OR ORDER AT WWW.MYREPLACEMENTPARTS.COM
The information in this owner’s manual is specific to your unit. When ordering replacement parts the information in this manual will help to ensure the correct items are ordered. Before contacting customer service write down the model number and the serial number of this unit. That information can be found on the certification label attached to the back of the unit. Other information that may be needed would be the part number and part description of the item(s) in question. Part numbers and descriptions can be found in the “Repair Parts” section of this manual. Once this information has been gathered you can contact customer service by phone 1-800-750-2723 Ext 5051 or Email parts@usstove.com.

Model Information

Model Number|
Serial Number|

INSTRUCTIONS SPECIFIC FOR CANADIAN INSTALLATIONS

  • Do not obstruct the space under the heater and do not obstruct the combustion air openings.
  • Refer to the chimney manufacturer’s instructions for disassembling the chimney for transportation of a transportable building.
  • This heater meets the requirements of CAN/ULC-S627 is suitable for installation on a combustible floor and does not require radiant floor protection.
  • The parts or materials to be employed for ember protectors and the minimum areas to be covered and their relation to the space heater, as well as the notice: “In Canada, to comply with CAN/ULC-S629, Installation Code for Solid-Fuel-Burning Appliances and Equipment, any combustible covering beneath the appliance and/or within the area extending horizontally at least 450 mm (18 in) beyond the appliance on any side equipped with a door, and at least 200 mm (8 in) beyond the appliance on other sides, be protected by a continuous, durable, non-combustible pad that will provide ember protection. The 450 mm (18 in) ember protection required on any side with a door shall extend for the full width of the appliance plus the 200 mm (8 in) required on each side of the appliance without a door. Where an appliance is installed less than 200 mm (8 in) from a wall, the ember pad need only extend to the base of the wall. An ember pad shall not be placed on top of a carpet unless the pad is structurally supported to prevent displacement and distortion.
  • Note: Do not install the chimney directly at the outlet of the appliance. A chimney connector (flue pipe) is required.
  • If this appliance is installed in a transportable building, removal of the chimney is required for transportation of the building.
  • DO NOT INSTALL IN AN ALCOVE
  • DO NOT INSTALL IN ANY FIREPLACE

REPAIR PARTS

Key Part # Description Qty
1 29139 Air Deflector 1
2 891824 Heatshield Weldment 1
3 40292A 6” Flue Collar 1
4 88042 1/4” Rope Gasket 1
5 610934 Pedestal Weldment (VG1120-BP) 1
6 610918 Access Panel (VG1120-BP) 1
7 29055 Ashpan 1
8 610944 Ashpan Housing Weldment 1
9 610883 Leg Weldment (VG1120-BL) 4
10 610928 Damper Weldment (VG1120-BL) 1
11 86709 Damper Rod 1
12 893162 Wooden Knob 1

VOGELZANG-VG1120-Wood-Heater-fig-24

To order parts: Call 1-800-750-2723 Ext 5051 or Email to: parts@usstove.com

Key Part # Description Qty
1 25089 Blower Housing Back 1
2 80442 80 CFM Blower 1
3 80090 Rheostat W/Knob 1
4 25090 Blower Housing Front 1
5 80109 Strain Relief 1
6 80232 Supply Cord 1
  • To order parts: Call 1-800-750-2723 Ext 5051 or Email to: parts@usstove.com
  • TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURER PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE APPLIANCE MANUFACTURER.
  • USE OF THIRD-PARTY COMPONENTS WILL VOID THE WARRANTY.
Key Part # Description Qty
1 29039 Brick Retainer 1
2 29040 Brick Retainer 1
3 88315 Kao Wool Blanket 1
4 88147 Board, Ceramic Fiber 1
5 86904 Secondary Tube 1
6 891414 Half Firebrick 4
7 89066 Firebrick (4-1/2 X 9) 4
8 891095 Firebrick (6 X 8-1/4) 3
9 23783 Firebrick (1-1/4 X 2-9/16 X 9) 4
10 86903 Secondary Tube 1
11 86905 Secondary Tube 1
Key Part # Description Qty
1 893241-VG Complete Door Handle 1
2 40881 Medium Sq Cast Door 1
3 88324 1” Round Rope Gasket-Blk 1
4 893154 Glass 1
5 29211 Left Side Glass Clamp 1
6 29210 Glass Clamp, Bottom 2
7 29231 Right Side Glass Clamp 1
8 29230 Gasket Clamp 1
9 892294 Hinge Pin 2

SERVICE RECORD

It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed.

SERVICE PROVIDER

Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s instructions. Always use the manufacturer’s specified spare part when replacement is necessary.VOGELZANG-VG1120-Wood-Heater-fig-27

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals