VIESSMANN VITOTRON 100, VLN2 Wall Mounted Electric Boiler Installation Guide
- June 9, 2024
- VIESSMANN
Table of Contents
WALL-MOUNTED ELECTRIC BOILER
Heating without fossil fuels, for residential applications
VITOTRON 100, VLN2
Installation Guide
VITOTRON 100, VLN2 Wall Mounted Electric Boiler
Plug-and-play electric heating
The Vitotron 100 makes its mark through simple installation, safe operation
and convenient control.
The Vitotron 100 is the easiest way to add hydronic space heating to new and
existing systems, with a space saving design and integrated components for a
fast and simple installation.
Vitotron 100, VLN2 electric boiler is an environmentally responsible and efficient heating source.
Aesthetically pleasing and easy to install
The compact profile and integrated control unit of the Vitotron 100, VLN2
electric boiler make it a welcome addition to any space. With efficient
operation and advanced controls, the Vitotron 100 offers superior design,
perfect for low temperature heating in space restrictive areas like closets
and small mechanical rooms.
Without venting and gas connections, the small plug-andplay device can be
installed practically anywhere. Installing the Vitotron 100, VLN2 electric
boiler does not require a gas connection, chimney or boiler room – all that is
needed is a power source.
The weather-compensated control unit utilizes an outdoor temperature sensor,
and heating curves ensure effective control by automatically adjusting the
water temperature according to the outside temperature. The heating curves and
operating efficiencies up to 99.4% ensure energy savings far above typical
electric space heating.
The Vitotron 100 comes with a 1.32 Gal (5 L.) diaphragm expansion vessel. The
VLN2 can be used with an outdoor temperature reset sensor with a thermostat
start/stop control and fixed set-point. Both the internal circulator and an
external circulating pump can be powered directly from the boiler.
Low maintenance and perfect for small vacation homes and additions
When an electric boiler is used to generate heat, the risk of system freezing
due to long absences is eliminated. The Vitotron 100 automatically switches on
when the temperature falls below an individually set minimum temperature,
allowing it to keep the room in a comfortable temperature range. Automatic
outdoor temperature sensor and warm weather shutdown can be used to keep
remote locations warm without using excess energy.
Heat storage
The use of an electric boiler in conjunction with a hot water buffer cylinder
ensures convenient and inexpensive heating with relatively low system costs.
The VLN2 can be used as a backup to a heat pump or used to maintain a storage
tank to take advantage of off-peak utility rates. The boiler features an
external shutdown input which can be used in conjunction with hybrid systems
and utility Home Energy Management Systems. VITOTRON 100
13.6 – 49.1 MBH 4.0 – 14.4 kW
The Vitotron 100 is perfect for well insulated homes and can also be installed
in dual fuel application such as cold climates where gas backup is necessary.
The VLN2 is also a perfect partner for photovoltaic systems and as a backup to
solar thermal systems. This allows the boiler to be operated even more
costeffectively, as priority is given to using the available, self-generated
energy from the roof. The combination of heat storage and free energy from a
photovoltaic system enables very low running costs.
PRODUCT FEATURES
+ Electric boiler with 4 to 14.4 kW rated output
+ Boiler for central heating only
+ All models use a thermostat for start/stop; outdoor reset can be used in
addition
+ Actual efficiency of 99.4 %
BENEFITS AT A GLANCE
+ Using the control unit, the water temperature in the heating zone can be
set to between 85°F and 140°F (29.4°C and 60°C)
+ Automatic modulation of the heating output according to the heat demand
+ Fits in small spaces and can be utilized as a backup or as a primary low
temp heat source
+ The weather-compensated control unit ensures energy efficient boiler
operation through automatic adjustments to reflect changes in the outside
temperature
VITOTRON 100, VLN2
- Modulating instantaneous submersible heating elements
- Safety temperature limiter
- Thermostat controlled and weathercompensated control unit
- High efficiency pump
- Pressure sensor
- Safety valve
Technical Information
VITOTRON 100, VLN2
Viessmann Manufacturing
Company (US) Inc.
Warwick, RI
800-288-0667
viessmann-us.com
VLN2-04 | VLNZ-06 | VLNZ-08 | VLN2-12 | VLN2-14.4 | ||
---|---|---|---|---|---|---|
kW | 4 | 6 | 8 | 12 | 14. | |
Boiler Rated Power | Btu/h | 13,652 | 20,478 | 27,304 | 40,956 | 49,147 |
Voltage | V | 240 | 240 | 240 | 240 | 240 |
Rated Current | A | 17. | 25.0 | 33. | 50.0 | 60.0 |
Breaker Quantity Amps | A | 1 e 30 amp | 1 @ 40 amp | 1 @ 50 amp | 1 0 60/70 amp | 1 |
@ 80 amp
Heating Elements| Ow| | 3| 3| 3| 3
Element Resistance / each| Q| 43.| 29.| 22.| 14.| 12.0
Weight| Lbs. kg| 68.5
3′| 68.5
31| 68.5
31| 68.5
31| 68.5
31
Overall dimensions
Depth| Inches mm| 91/4
251| 91/4
251| 91/4
251| :7/8
251| 91/4
251
Width| Inches mm| 17
432| 17
432| 17
432| 17
432| 17
432
Height| Inches mm| 28
711| 28
711| 28
711| 28
711| 28
711
Minimum Flow Rates| gpm| 1.| 1.| 1.| 1.| 1.
Technical information subject to change without notice.
Printed in USA 11/22
Documents / Resources
|
VIESSMANN VITOTRON 100, VLN2 Wall Mounted Electric
Boiler
[pdf] Installation Guide
VITOTRON 100 VLN2 Wall Mounted Electric Boiler, VITOTRON 100, VLN2 Wall
Mounted Electric Boiler, Mounted Electric Boiler, Electric Boiler
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>