LevelOne Industrial mini Media Converter Installation Guide
- June 7, 2024
- LevelOne
Table of Contents
IEC-4001/4002/4301
Industrial mini Media Converter 10/100Base-TX to 100Base-FX
Quick Installation Guide
Overview
LevelOne IEC-4001/4002/4301 is an industrial Fast Ethernet media converter with a rugged aluminium case that providing superb heat dissipation. This converter is designed to be mounted on an industrial standard DIN-rail, plus the clearly visible status LEDs provide simple monitoring of port link activity. It also features Link Fault Pass-Through in order to alert remote location when link status changes.
High Reliability
All components are built to withstand harsh environment applications without compromise where humidity, temperature variation and even shock vibration are concerns, including Electric & Utility, Critical Infrastructure, Transportation and Surveillance Security. This device operates under -40 to 75 Celsius (-40 to 167 Fahrenheit) temperature.
Ultra-Compact
The ultra-compact converter has the smallest form-factor of any such device in
the world, but still offers industrial levels of toughness. Housed in a rugged
IP31 aluminium case with inbuilt surge and ESD protection,
the device measures just 59mm by 49mm, with a height of 36mm.
Features
- 10/100BaseT to 100Base-FX
- Rugged aluminium case design in an ultra-compact form factor
- 18V-36VAC & 12V-60VDC with polarity protection
- Link Fault Pass-through (LFP) function
- Supports switch and pure converter mode
- Surge & ESD protection
- Maximum noise & interference immunity
- -40°C to 75°C (-40°F to 167°F) operating temperature range
- DIN-Rail or panel mount installation
Package Contents
- Industrial mini Media Converter
- Quick Installation Guide
- DIN-rail & Panel mount kits
Model No. Description
Industrial
| IEC-4001| 10/100 Industrial Media Converter, SC MM 2KM -40 to 75C
---|---|---
C-4002| 10/100 Industrial Media Converter, ST MM 2KM -40 to 75C
IEC-4301| 10/100 Industrial Media Converter, SC SM 30KM -40 to 75C
LED Status
LED | Status | Description |
---|
PWR
| Steady| Power On
Off| Power Off
LK/Act| Steady| Fibre link established
Flashing| Transmitting or Receiving data
| 10/100Base-TX|
Green| Steady| Network connection established
Flashing| Transmitting or Receiving data
Amber| Stead| 100M speed is established
Off| 10M speed is established
Power Input
Terminal Block
| V+| 18 – 36VAC or 12 – 60VDC
---|---|---
V–| Neutral Ground
| Earth Ground
Note:
This unit provides a 3 pin terminal block. And it can be operated using
either VAC or VDC power source. The DC power range is from 12VDC to 60VDC,
and the VAC power range is from 18VAC to 36VAC. Always Make sure your input
voltage is within this supported voltage range.
WARNING – any exceeded input voltage will not make this unit function and
may damage this unit. To make power connection – Follow the printed polarity
for V+, V- and Ground. Connect the positive wire to V+, connect negative wire
to V-, and also connect neutral wire to ground.
DIP Switch
| DIP2| DIP1
---|---|---
ON| LFP enabled| Converter Mode
OFF| LFP disabled(default)| Switch Mode(default)
Note :
This unit is equipped with dip switches, located on the front panel marked as
SW1. Adjusting the dip switches will change the default function of this unit.
This unit has set to manufacturer default as: switch mode and LFP function
off.
The table is shown as you may change the dip switch setting to your desired
environment.
DIN Rail Mount
- Assembly : Place the switch on the DIN rail from above using the slot. Push the front of the switch toward the mounting surface until it audibly snaps into place
- Start-up : Connect the supply voltage to start up the switch via the terminal block (or DC JACK)
- Dismantling : Pull out the lower edge and then remove the switch from the DIN rail.
10/100Base-TX Connector
Pin | Standard Port | Uplink Port |
---|---|---|
1 | Output Transmit Data + | Input Receive Data + |
2 | Output Transmit Data – | Input Receive Data – |
3 | Input Receive Data + | Output Transmit Data + |
4 | NC | NC |
5 | NC | NC |
6 | Input Receive Data – | Output Transmit Data – |
7 | NC | NC |
8 | NC | NC |
IEC-4001/4002/4301