AeoTec Radiator Thermostat User Manual

June 7, 2024
Aeotec

AeoTec logo Radiator Thermostat
SKU: AEOEZWA021

AeoTec Radiator Thermostat

Product-Labels

Quickstart

This is a secure HVAC-Thermostat for Europe. To run this device please insert fresh *2 AA LR6** batteries. Please make sure the internal battery is fully charged. – Start the Inclusion mode of your primary Z-Wave Controller. – Press the Boost-Button. – Aeotec Radiator Thermostat will show the assigned NodeID.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor, and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave TM?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave-Logo-png Z-Wave ensures reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter. This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range. If a device supports secure communication, it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise, it will automatically turn into a lower level of security to maintain backward compatibility. For more information about Z-Wave technology, devices, white papers, etc. please refer to www.z-wave.info.

Product Description

Aeotec Radiator Thermostat is a Z-Wave radio standard compatible energy-saving radiator thermostat for Europe.

Prepare for Installation / Reset

Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network, it must be in the factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default
This device also allows being reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.

  1. Remove batteries.
  2. Press and hold the boost button.
  3. While still holding the boost button insert batteries.
  4. The LCD shows RES. Release boost button.
  5. To perform the factory reset press the boost button.

Safety Warning for Batteries
The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of different charging levels or different brands.

Installation

Mounting the Aeotec Radiator Thermostat
After adding the Aeotec Radiator Thermostat to a network it is ready to be installed on the radiator. The LCD shows INS. Do not press the boost button yet.
Installation at the radiator without Adapter
aeotec radiator thermostat - Installation at the radiator without
Adapter

Installation at the radiator without Adapter
aeotec radiator thermostat - Installation at the radiator without
Adapter

Mechanical Installation

Press the boost button to start the mechanical installation.

aeotec radiator thermostat - Mechanical Installation
Unmounting the Aeotec Radiator Thermostats
aeotec radiator thermostat - Unmounting the Aeotec Radiator
Thermostats

Inclusion/Exclusion

On factory default, the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion
1. Insert the batteries
2. Press the Boost-Button once.

Exclusion
1. Press and hold the boost button of the Radiator Thermostat for at least 5 seconds.

Product Usage

Buttons:aeotec radiator thermostat - Buttons
aeotec radiator thermostat - Product Usage
Boost-Taste Leds
aeotec radiator thermostat - Boost-Taste Leds-2LCD
aeotec radiator thermostat - LCD

Wrench: Lights up if mechanical tasks are ongoing
Antenna:
Displays the Radiator Thermostat network state. Segment visible: rf-link established Segment turnoff: rf-link lost
 ID: Lights up if the Display shows the Z-Wave NodelD
 Battery Lights up if less than 15% of the battery is remaining
 Lock: Light up if child protection is set
Degree Celsius: Displayed if the LCD shows a setpoint temperature

Inserting batteries
Remove the battery cover by simply pulling it off. Now insert the batteries. Pay attention to the correct polarity! Ata later battery change, the configuration of your Aeotec Radiator Thermostat is maintained.

aeotec radiator thermostat Inserting batteries

Setpoint adjustment
The setpoint is adjusted via the plus and minus buttons.
Altering the setpoint locally will set the theAeotec Radiator Thermostat in heating mode.
The energy-saving setpoint can only be adjusted via Z-Wave.
The configurable setpoint range is 8°C to 28°C.
If the setpoint is increased/decreased above/below the set point limits the Aeotec Radiator Thermostat will change into boost / off mode.

Child protection
Press and hold the plus and minus buttons simultaneously for 3 seconds to enable/disable the child protection. If the Aeotec Radiator Thermostat is set into the highest protection level it is no longer possible to operate the device locally.
Altering the operating states
Off-Mode
Press minus button until OFF is displayed.
Boost-Mode
Push the boost button. Alternatively, press the plus button until ON is displayed.
Heating-Mode
If the operating state is not heating mode, pressing the plus or minus button will bring the device in heating mode.
Window open detection
If the room temperature drops the window open detection will trigger. Aeotec Radiator Thermostat will change temporarily in off mode for 15 minutes. Window open detection will end automatically after 15 minutes and the previously active operating mode will be restored. Window open detection can also be canceled by a button press. The window open detection is disabled during the manufacturer-specific mode. The sensitivity of the windows open detection can be configured

DisplayNodeID
Press and hold the boost button for 3 seconds to display the NodeID.

Quick troubleshooting

Here are a few hints for network installation if things don’t work as expected.

  1. Make sure a device is in a factory reset state before including it. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise, you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Don’t poll FLIRS devices.
  6. Make sure to have enough mains powered devices to benefit from the meshing

Association – one device controls another device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, …). In case the event happens all devices stored in the respective association group will receive the same wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however, certain configurations can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 … 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200it may be needed to set a value of 200 minus 256 = minus 56. In the case of a two- byte value, the same logic applies: Values greater than 32768 may be needed to be given as negative values too.

Parameter 1: LCD invert
Inverts the LCD orientation Size: 1 Byte, Default Value: 0

Setting Description
0 Normal orientation
1 LCD content inverted

Parameter 2: LCD Timeout
Configures the timeout of the LCD. Size: 1 Byte, Default Value: 0

Setting Description
0 LCD always on
5 – 30 LCD timeout in seconds

Parameter 3: Backlight
Enables or disables the LCD-Backlight.
Size: 1 Byte, Default Value: 1

Setting Description
0 Backlight disabled
1 Backlight enabled

Parameter 4: Battery report
Enables or disables unsolicited battery reporting once a day.
Size: 1 Byte, Default Value: 1

Setting Description
0 Battery reporting disabled
1 Battery reporting enabled

Parameter 5: Measured temperature report
Reports the measured room temperature on change.
Size: 1 Byte, Default Value: 5

Setting Description
0 Reporting disabled
1 – 50 Reporting Delta in 1/10 Celcius

Parameter 6: Valve percentage report
Reports the valve percentage on change.
Size: 1 Byte, Default Value: 0

Setting Description
0 Reporting disabled
1 – 100 Reporting Delta in percent

Parameter 7: Window open detection
Configures the sensitivity of the window open detection. Sensitivity level: 1 low 2 medium 3 high
Size: 1 Byte, Default Value: 2

Setting Description
0 Detection disabled
1 – 3 Sensitivity level

Parameter 8: Measured temperature offset
Configures an offset for the measured temperature. Set the offset to -128 (0x80) if the measured temperature is provided externally.
Size: 1 Byte, Default Value: 0

Setting Description
0 – 50 Offset in 1/10 Celcius (0°C – 5°C)
128 Temperature is supplied externaly
206-255 Offset in 1/10 Celcius (-5°C – 0,1°C)

Technical Data

Dimensions 55 x 67 x 67 mm
Weight 127.64 gr
Hardware Platform ZM5202
EAN 4.2513E+12
IP Class IP 20
Voltage 3V
Battery Type 2 * AA LR6
Device Type Thermostat – HVAC
Network Operation Listening Sleeping Slave
Z-Wave Version 6.71.01
Certification ID ZC10-19086734
Z-Wave Product Id 0x0371.0x0002.0x0015
Firmware Updatable Updatable by Consumer by RF
Sensors Air Temperature
Supported Notification Types Power Management System
Thermostat HVAC Systems Supported Heat Only
Thermostat Modes Energy Save Heat
Frequency Europe – 868,4 Mhz
Maximum transmission power 5 mW

Supported Command Classes

  • Association Grp Info
  • Association V2
  • Basic
  • Battery
  • Configuration
  • Device Reset Locally
  • Firmware Update Md V3
  • Manufacturer Specific
  • Notification V8
  • Powerlevel
  • Protection
  • Security
  • Security 2
  • Sensor Multilevel V5
  • Supervision
  • Switch Multilevel
  • Thermostat Mode V3
  • Thermostat Setpoint V3
  • Transport Service V2
  • Version V2
  • Zwaveplus Info V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways, Remote Controls, or battery-operated wall controllers.
  • Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators, and even remote controls.
  • Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.
  • Inclusion — is the process of adding new Z-Wave devices into a network.
  • Exclusion — is the process of removing Z-Wave devices from the network.
  • Association — is a control relationship between a controlling device and a controlled device.
  • Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.
  • Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.