Aeiusny Uninterrupted Power Supply User Manual
- June 7, 2024
- Aeiusny
Table of Contents
Uninterrupted Power Supply
Model: UPS-500AD
User Manual
Please read the manual carefully before you use it
Introduction
UPS-500AD is the lightest, thinnest, and highest-capacity battery generator manufactured by advanced lithium battery technology. We provide three output modes, AC wall plug, a USB-A adapter, and a direct DC12V adapter can be used. It is not only an online ups but also a backup power that can charge portable electronic products. It is applied to various fields such as exploration, scientific and technological research, media photography, outdoors etc.
WARNING
- This product has a built-in lithium battery, which keeps it away from fire. Please consult your local regulations as to the proper disposal of hazardous waste.
- Make sure the product is protected from moisture and keep it away from water or humid conditions.
- Do not drop, puncture, or damage this product as it may cause the battery to become unstable.
- Stop using the product once it smokes or gets on fire during working. And put off the fire with extinguisher immediately to an explosion.
- Use the product in a good ventilation area so that ups won’t shut off because of overheating.
- Please switch on the product firstly, and choose DC or AC output, make sure the output indicator light is on, then start to use the product to supply power.
- Before initial use, fully discharge the battery and fully recharge the battery.
- Charge-ups every 3-6 months to extend the battery life if you will not use it for a long time.
Instruction
Notice: When a wall socket is available, the UPS can be charged even while on standby mode. The battery is fully charged when it indicates 12.4V voltage or above, then it can be used for backup power supply of outdoor activities. Make sure to the AC switch is off, and turn it on only when you need to use it. Otherwise, it will drain the battery.
AC power supply
As shown in the figure, plug the AC input power cord into the socket, then connect the end device into the socket of UPS-500AD, turn on the AC output switch, UPS is ready. Only when blackout, the UPS-500AD will automatically switch over to power your equipment by using the built-in lithium battery power. Do not connect any device than 500 watts. The UPS will shut down and stop working to protect the batteries. Reduce load and restart. The fuse may get snapped when overloaded. Rarely when it occurs, turn off the product, replace an 8A fuse and restart. There are two versions of the AC input 100 – 120V / 60HZ please purchase according to local voltage and frequency standards.
Indicator
- DC Output indicates DC port and USB port work status(normal: Green, unusual: Red)
- Power/Fault: Indicates AC power supply status(normal: Green, unusual: Red) Battery indicator display low: Red light flash and buzzer ring overload: Red light flashes, buzzer ring, No power output
- AC Charge: Indicates AC input charging status(During Charging: Red, Fully charged: Green)
- Solar Charge: Indicate solar input charging and car input charging status(During Charging: Red, Fully charged: Green)
- Battery indicator: The display panel will show the battery capacity. When the percentage shown is low, please charge the unit accordingly.
The product will automatically switch over to power your computer with an
inside lithium battery when power off. So the computer will be online
uninterruptedly with UPS-SOOAD.
Notices: Don’t connect the UPS-500AD to equipment with a load that is
over 500W or overload will occur. When there is an overload, it will shut
down. You need to reduce your total equipment load and try again.
In rare cases, when the UPS encounters an external short circuit or unusual
power usage, the external fuse will be burned, when this happens, you can just
replace the fuse. The fuse is 8A.
DC power supply
For optimal use with CPAP Worry about no power to power your CPAP while camping? Don’t worry, our portable power station can solve your problem. Aeiusny power station has two ways to power your CPAP machine: 110V AC Plug or 12V DC Plug. We strongly recommend CPAP users to turn off or remove the HEATER/ HUMIDIFIER while powering a CPAP machine so that the power station can power a long time. To buy the DC converter, please consult with your CPAP supplier or simply reach us for a guide.
Notice:
When not using the DC power, keep the DC switch off to avoid the power
consumption of the inside battery. When using DC output, turn on the DC switch
first, the LED indicator will turn on, then the product is ready for DC 5V and
12V output. When not using the DC power, keep the DC switch off to avoid the
power consumption of the inside battery. LED screen displays battery power.
When the battery voltage falls below 9V, the battery is nearly gone. You can
turn off the switch, fully charge the product and restart.
Turn on DC ON/OFF switch, the LED light will be turned on, then the product is ready for DC 5V and 12V output and the 12V DC port is ready to be used. When the battery voltage falls below 9V, the battery is nearly gone, you ou can turn off the switch, fully charge the product and restart.
Notices:
Please confirm whether your DC12V appliance support charging with 5. 5mm DC
header interface (the diameter of the DC port of the product is: 5. 5mm)
otherwise it is unable to connect with the DC output, you can consult the
electrical manufacturer, buy the corresponding adapter and connect with it.
The 12V DC output the maximum total current 10A, each DC output maximum
current 5A.
Solar charging
This interface is a solar charging port. The solar panel should be 18V 2.1A maximum 120W. When connected to a solar panel, make sure the positive and negative are correct. The product will not be charged under an incorrect connection. The solar charging indicator light appears red and turns green when fully charged. The product can be used for online uninterruptible power systems, but also as a backup battery power supply.
Notices: When connecting to the solar panel, please make sure that the polarity must be correct, if not, the solar charging will not work and the LED light will appear RED, Solar charging indicate status(charging: Red, charging completed: Green)
Charging through 12V car charger
Connect the car charging cable to the SOLAR CHARGE input port and plug the car cigarette lighter into your car socket to charging the UPS. the LED light will appear green when charging is completed.
Notices: When using the car charger, it may happen that the LED immediately shows the green, which is the UPS battery instantaneous voltage exceeds 12 4V results, you need to disconnect, reconnect.
Product Parameters Table
Product Model | UPS-SO0AD |
---|---|
Output Power | Rated 500W, Peak 1000W |
Input Voltage | AC 100-220V 50/60Hz |
Output Voltage | AC 100-120V 50/60Hz |
Battery Capacity | lithium battery 12V/24AH(288Wh) |
USB Output | 29V/2.1A, 21‘5V/1A, fit for any mobile, iPad, laptop, or other 5V |
electronic devices
DC Output| 412V(9-12.6V) ports, maximum 8A output current
LED Light| 1W Ultra Bright LED Flashlight
Solar Charging| 18V/2. 1A Max,40-120W(maximum input power)
Output Wave| Sine Wave
Blackout Response Time| <5MS
Overload| AC output indicator light will turn red and the product will
automatically shut off if overloaded. When it occurs, reduce the load and
restart the product.
Short Circuit| The product will automatically shut off if short circuit. When
it occurs, plug off the load and restart the product.
Function| lithium batteries can be used for high-power charging and
discharging, and this product is built-in with advanced overcharge, over-
discharge, short-circuit protection control unit. Meanwhile, lithium battery
is green energy and will not bring pollution to our environment.
Weight/Size| 7.051b/11.45.1*4.3 inch
Accessories list
Inner Box Size : 35*24•17cm Weight : 8.81b
Serial | Name | Quantity |
---|---|---|
1 | UPS-500AD Generator | 1 |
2 | AC Charging Cable | 1 |
3 | DC Cable(5.5*2.1 mm) | 1 |
4 | Car Charging Cable(0.6mm) | 1 |
5 | User Manual and Warranty Card | 1 |
Backup Time
Equipment | Backup Time |
---|---|
5V Smartphone | iPhone 40+ Recharges |
12V/3W LED Light | 96 Hours |
Drone | 6+ Recharges |
13″ Laptop | 8 Hours |
SOW Fan | 6 Hours |
32″ LCD TV | 5 Hours |
CPAP | 2 Nights+ |
Switch over automatically when blackout. Always online!
Warnings
The UPS can support Devices below 500W, so the following devices are not supported.
Customer questions & answers
Q. What appliance this item can supply power?
A. Please ensure that your AC device’s total power does not exceed SCOW,
otherwise, the UPS will shut down and stop working to protect the batteries.
Cl: Calculate the Working Time for Your Device:
A: Charging time=288Wh/Your device power, For example, Your device Power is 60
watts. Then the working time= 288wh/60w=4.8 hrs.(lt will be consumed by
itself, please turn off the switch when you are not using it.)
Please note: actual power consumption varies from different usages, consult
Aeiusny for a better purchase decision.
Q: Suggested Related Solar Panel:
A: We suggest you can choose a 60-120W solar panel whose Optimum Operating
Voltage (Vmp) is 18V, because of its higher power, charging faster, charging
speed is also relating to sun intensity.
Q. How to check if the generator is fully charging?
A. When the LED “%” up to 100%, you also need to check if the LED “AC CHARGE”
or “Solar Charge” turned to green, then it indicates fully charged.
Q. Why the Led AC CHARGE” will be flashed when using AC outlet?
A. When turning on the button AC output ON/OFF” to use AC outlet, the LED
“POWER/FAULT” turn to green, and the Led AC CHARGE” will flash on and off the
green, this is normal because our generator has a UPS function, this indicator
light flashes to remind that this item hasn’t started UPS function when you
Plug the AC INPUT to the Wall Charger, the AC charge led will be not flashed.
https://www.facebook.com/Aeiusny
WWW.AEIUSNY.COM
E-mail: customer-service@aeiusny.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>