EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Instruction Manual

June 7, 2024
Emerson

EMERSON logo

Copeland ™ Outdoor
Refrigeration Unit, X-Line Series
Fixed speed and digital capacity units for medium and low-temperature applications

EMERSON Copeland Outdoor Refrigeration Unit X-Line
Series Small-Format Stores • Convenience Stores • Foodservice Establishments
R-22, 134a, 404A/507A, 407C/A, 448A/449A • ¾ – 6 HP


Innovative design based on three factors demanded by industry users.

1. Energy Efficiency
Copeland Outdoor Refrigeration Units signifi cantly reduce energy consumption by utilizing scroll and digital scroll compressor technology, variable speed fan motors, large capacity condenser coils and advanced control algorithms. Compared to hermetic reciprocating units, end-users will save up to 50% in energy costs.

EMERSON Copeland Outdoor Refrigeration Unit X-Line
SeriesInnovative

2.Reliability
Combining the proven reliability of Copeland scroll compressors with advanced onboard diagnostics, equipment reliability is greatly enhanced. Fault code alerts and fault code retrieval capabilities provide information to help improve speed and accuracy of system diagnostics. Integrated electronics provide protection against overcurrent, over-heating, incorrect phase rotation, compressor cycling, high-pressure resets, low-pressure cut-outs, and liquid flood-back conditions that cause unexpected performance losses or worse, unplanned equipment failure. As part of the Emerson family f products, Copeland Outdoor  Refrigeration Units provide unsurpassed access to system status, diagnostics, and operational control.

3.Flexibility
The lightweight and slim-line profile ease the installation process. The ultra-quiet variable-speed fan motor significantly reduces exterior sound levels, allowing use in noise-restricted residential zones. With high and low ambient operation capability, coated coils for coastal applications, multi- refrigerant capabilities, and optional all mounting capability, the units deliver unmatched mounting and environmental location flexibility. Copeland outdoor Refrigeration Units are perfectly suited for walk-in and display case applications. All units integrate any benefits of scroll compressor technology, fan speed control, and advanced onboard diagnostics, delivering higher energy efficiency and lower sound levels while ensuring reliable performance and operation in foodservice applications.

EMERSON Copeland Outdoor Refrigeration Unit X-Line
SeriesFlexibility

Two sound values shown represent the X-Line unit’s lowest and highest operating dBA measurements, or typical industry outdoor unit published data, for both  MT and LT products. Sound pressure values are 10 feet from the unit at 25°F evap for MT and -10°F evap for LT at 90°F ambient. A sound reduction of up to 3 dBA ill occur in ambient temperatures below 70°F This data is typical of ‘free field’ conditions for horizontal air-cooled condensing units and may vary depending on the condensing unit installation. There are many factors that affect the sound reading of a condensing unit such as unit mounting, reflecting walls, background noise and operating condition.

Standard Features

  •  Electronic control module consolidating all unit operations, defrost, diagnostics, compressor protection, and  communications
  • External service valves and hinged service panel for easy setup and service
  • Standard moisture indicator and liquid filter drier
  • Quiet variable speed condenser fan
  •  Heated and insulated receiver with pressure relief valve
  • Powder-coated galv-annealed chassis and coated condenser fins for corrosion protection
  • Standard accumulator and oil separator on low temp models.
    Optional accumulator on only fixed speed medium temp models.

EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Standard
Features

Accessories

Part Number Description Purpose
074-7286-00 Wall bracket Allows mounting unit to walls
074-7289-00 Adjustable stand Raises unit 12 inches from ground level
943-0224-00 PC interface kit Allows direct connection of unit to PC
943-0058-00 Remote display Control/view unit status up to 30 feet from unit

Nomenclature

X Family = X-Line
F F = Multi-refrigerant
A A = Air-Cooled
M L = Low Temp

M = Medium Temp

P = Multiple Applications

–|
0| 75 to 6.0 = HP
2
0
Z| Z = Scroll

D = Digital Scroll

–|
T| CFV = 208/230V-1ph60Hz

TFC = 208/230V-3ph60Hz

F
C
–|
0| 0 = UL Listed Product
8| 81 = Standard
1

To place an order select Base Model > Electrical > Bill of Material

Feature
Energy improvement
Sound improvement
Diagnostic protection capabilities Slim profi le, lighter weight, and optional wall mount capability
Multi-refrigerant*
Emerson family of electronics

  • Visit Climate. Emerson.com/OPI for specifi c refrigerant approvals for each model.

Owner/Enterprise Benefit

  • Lower operating costs
  • Creating a more comfortable environment for guests
  • Benefi cial for regions with noise ordinances
  • Reduce nuisance calls
  • Extends life of your equipment
  • Faster, more accurate service, and reduced call-backs
  • Maintains your equipment to original standards, maintaining energy effi ciency and temperature control
  • Have confi dence in what your contractor is fi xing
  • Lower installation costs
  • Improved appearance of your enterprise site
  • Avoids more costly solutions for potential location issues
  •  R-22, R-134a, R-404A, R-407C/A, R-448/449A
  •  Scalable electronics can operate as a stand-alone unit or connect as part of a full intelligent store.

Copeland Digital Outdoor Refrigeration Unit, X-Line Series The compact solution for continuous capacity modulation

The Copeland Digital Outdoor Refrigeration Unit sets a new standard for energy effi ciency, reliability, and installation fl exibility. With 20-100% modulation now  available and expanded refrigerant approvals, its  industry leading on- board diagnostics and system protection can help optimize operational effi ciency and  deliver peace of mind to any end user. Digital X-Line units are available for applications commonly found in  today’s food service and food retail establishments.

The perfect solution for refrigeration applications with wide load variation:

  •  Walk-In Coolers
  • Food Preparation Rooms
  •  Display Cases
  • Industrial Process Chillers

Digital compression technology means fewer condensing units are needed to install and maintain for numerous refrigeration loads, which results in fewer line runs, lower refrigerant charges, and faster installation.

EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Copeland
Digital

A Superior Solution for Food Safety
Digital modulation enables tighter control of case temperatures. This provides supermarkets and foodservice establishments with the security of knowing that their food is safe from harmful bacteria growth and other harmful micro- organisms.

A Superior Solution for Energy Savings
Traditional modulation technologies consume close to full load energy no matter what the required capacity. Copeland digital scroll compressor technology reduces power consumption linearly as it modulates capacity resulting in optimum system performance and control, as shown in Chart A.

Chart A
Temperature control comparison digital vs. standard technology.EMERSON
Copeland Outdoor Refrigeration Unit X-Line Chart A

What’s Inside

EMERSON Copeland Outdoor Refrigeration Unit X-Line What’s
Inside

Dimensional Drawings

EMERSON Copeland Outdoor Refrigeration Unit X-Line Dimensional
DrawingsEMERSON Copeland
Outdoor Refrigeration Unit X-Line Bottom View

Application Engineering Bulletins

available at Climate.Emerson.com/OPI 
4-1273 Factors to Consider in Converting Compressor
Rated Capacity to Actual Capacity
4-1327 Economized Vapor Injection (EVI) Compressors
11-1147 Suction Accumulators
11-1297 Liquid Line Filter Driers
17-1260 Compressor Overheating
17-1268 Compressor Ratio as it Affects Compressor Reliability
22-1182 Liquid Refrigerant Control in Refrigeration  and Air Conditioning Systems
5-1412 Copeland Scroll Outdoor Refrigeration Unit – X-Line User Manual (This bulletin is provided with
each unit and is a source for additional product details.

For more information visit Climate.Emerson.com/CopelandOutdoorUnit

Diagnostic Features

On-board diagnostics provide connectivity to facility management control systems (including Emerson’s Site  Supervisor suite of control products) to alert owner/operators of faults and key performance indicators (KPIs).

  • Over-current protection
  • Incorrect phase detection
  • High-pressure lockout
  •  Flood-back prediction
  •  Demand Cooling™
  •  Flooded start protection (“bump-start” logic)
  • Discharge temperature protection
  • Anti-short cycle time delay
  • Digital fault code display/remote alarming
  • Over/under voltage protection

EMERSON Copeland Outdoor Refrigeration Unit X-Line Series Diagnostic
Features

Specifications

Unit Model| Compressor Electrical| Chassis Size| L| W| H| Refrigerant Connections| Receiver Capacity (Lbs @ 90% Volume)|

MCA

| Max Over- current Protection*
---|---|---|---|---|---|---|---|---|---
Liquid| Suction| R-134a| R-22| R-404A| R-407A| R-407C| R-448A| R-449A
XFAL-008Z-CFV| ZF03KAE-PFV|

1 FAN

| 16.7| 40.5| 33.1|

1/2 S

|

7/8 S

|

N/A

|

N/A

|

9.1

|

10

|

10

|

9.7

|

9.7

| 9.1| 15
XFAL-008Z-TFC| ZF03KAE-TF5| 16.7| 40.5| 33.1| 6.2| 15
XFAL-009Z-CFV| ZF04KAE-PFV| 16.7| 40.5| 33.1| 10.3| 15
XFAL-009Z-TFC| ZF04KAE-TF5| 16.7| 40.5| 33.1| 9.3| 15
XFAL-010Z-CFV| ZF05KAE-PFV| 16.7| 40.5| 33.1| 11.9| 15
XFAL-010Z-TFC| ZF05KAE-TF5| 16.7| 40.5| 33.1| 10.4| 15
XFAL-012Z-CFV| ZF07KAE-PFV| 16.7| 40.5| 33.1| 18.4| 30
XFAL-012Z-TFC| ZF07KAE-TF5| 16.7| 40.5| 33.1| 11.8| 15
XFAL-020Z-CFV| ZXI06KCE-PFV| 16.7| 40.5| 33.1| 21.55| 35
XFAL-020Z-TFC| ZXI06KCE-TF5| 16.7| 40.5| 33.1| 16.18| 25
XFAL-030Z-TFC| ZXI09KCE-TF5| 16.7| 40.5| 33.1| 17.18| 25
XFAL-035Z-CFV| ZXI11KCE-PFV| 16.7| 40.5| 33.1| 34.05| 50
XFAL-040Z-CFV| ZXI14KCE-PFV|

2 FAN

| 16.7| 40.5| 48.9|

13.4

|

14.8

|

14.7

|

14.2

|

14.3

| 40.1| 60
XFAL-040Z-TFC| ZXI14KCE-TF5| 16.7| 40.5| 48.9| 27.1| 45
XFAL-050Z-TFC| ZXI15KCE-TF5| 16.7| 40.5| 48.9| 28.85| 45
XFAL-051Z-CFV| ZXI16KCE-PFV| 16.7| 40.5| 48.9| 44.73| 70
XFAL-060Z-TFC| ZXI18KCE-TF5| 16.7| 40.5| 48.9| 33.98| 50
XFAM-008Z-CFV| ZB06KAE-PFV|

1 FAN

| 16.7| 40.5| 33.1|

10.7

|

10.5

|

9.1

|

10

|

10

|

9.7

|

9.7

| 9.3| 15
XFAM-008Z-TFC| ZB06KAE-TF5| 16.7| 40.5| 33.1| 8.05| 15
XFAM-010Z-CFV| ZB07KAE-PFV| 16.7| 40.5| 33.1| 9.3| 15
XFAM-010Z-TFC| ZB07KAE-TF5| 16.7| 40.5| 33.1| 8.1| 15
XFAM-012Z-CFV| ZB08KAE-PFV| 16.7| 40.5| 33.1| 11.1| 15
XFAM-012Z-TFC| ZB08KAE-TF5| 16.7| 40.5| 33.1| 8.1| 15
XFAM-015Z-CFV| ZS09KAE-PFV| 16.7| 40.5| 33.1| 13.55| 20
XFAM-015Z-TFC| ZS09KAE-TF5| 16.7| 40.5| 33.1| 11.05| 15
XFAM-017Z-CFV| ZS11KAE-PFV| 16.7| 40.5| 33.1| 16.8| 25
XFAM-017Z-TFC| ZS11KAE-TF5| 16.7| 40.5| 33.1| 14.05| 20
XFAM-020Z-CFV| ZS13KAE-PFV| 16.7| 40.5| 33.1| 16.1| 25
XFAM-020Z-TFC| ZS13KAE-TF5| 16.7| 40.5| 33.1| 13.2| 20
XFAM-022Z-CFV| ZS15KAE-PFV| 16.7| 40.5| 33.1| 20.68| 35
XFAM-022Z-TFC| ZS15KAE-TF5| 16.7| 40.5| 33.1| 14.3| 20
XFAM-025Z-CFV| ZS19KAE-PFV| 16.7| 40.5| 33.1| 23.6| 40
XFAM-025Z-TFC| ZS19KAE-TF5| 16.7| 40.5| 33.1| 18.2| 30
XFAM-030Z-CFV| ZS21KAE-PFV| 16.7| 40.5| 33.1| 30.05| 50
XFAM-030Z-TFC| ZS21KAE-TF5| 16.7| 40.5| 33.1| 20.05| 30
XFAM-030D-CFV| ZBD21KCE-PFV| 16.7| 40.5| 33.1| 24.7| 40
XFAM-030D-TFC| ZBD21KCE-TF5| 16.7| 40.5| 33.1| 16.8| 25
XFAM-033Z-CFV| ZS26KAE-PFV| 16.7| 40.5| 33.1| 30.6| 50
XFAM-033Z-TFC| ZS26KAE-TF5| 16.7| 40.5| 33.1| 20.4| 30
XFAM-037Z-CFV| ZS29KAE-PFV| 16.7| 40.5| 33.1| 33.7| 50
XFAM-037Z-TFC| ZS29KAE-TF5| 16.7| 40.5| 33.1| 26.7| 45
XFAM-040D-TFC| ZBD30KCE-TF5|

2 FAN

| 16.7| 40.5| 33.1| 21.7| 35
XFAM-045Z-CFV| ZS33KAE-PFV| 16.7| 40.5| 48.9|

15.7

|

15.5

|

13.4

|

14.8

|

14.7

|

14.2

|

14.3

| 37.35| 60
XFAM-045Z-TFC| ZS33KAE-TF5| 16.7| 40.5| 48.9| 29.98| 50
XFAM-050Z-CFV| ZS38K4E-PFV| 16.7| 40.5| 48.9| 41.85| 70
XFAM-050Z-TFC| ZS38K4E-TF5| 16.7| 40.5| 48.9| 28.85| 45
XFAM-050D-CFV| ZBD38KCE-PFV| 16.7| 40.5| 48.9| 45.0| 70
XFAM-050D-TFC| ZBD38KCE-TF5| 16.7| 40.5| 48.9| 31.7| 50
XFAM-060Z-TFC| ZS45K4E-TF5| 16.7| 40.5| 48.9| 31.98| 50
XFAM-060D-TFC| ZBD45KCE-TF5| 16.7| 40.5| 48.9| 30.2| 50
XFAP-015Z-CFV| ZS09KAE-PFV|

1 FAN

| 16.7| 40.5| 33.1|

10.7

|

10.5

|

9.1

|

10

|

10

|

9.7

|

9.7

| 13.55| 20
XFAP-015Z-TFC| ZS09KAE-TF5| 16.7| 40.5| 33.1| 11.05| 15
XFAP-017Z-CFV| ZS11KAE-PFV| 16.7| 40.5| 33.1| 16.8| 25
XFAP-017Z-TFC| ZS11KAE-TF5| 16.7| 40.5| 33.1| 14.05| 20
XFAP-020Z-CFV| ZS13KAE-PFV| 16.7| 40.5| 33.1| 16.1| 25
XFAP-020Z-TFC| ZS13KAE-TF5| 16.7| 40.5| 33.1| 13.2| 20
XFAP-022Z-CFV| ZS15KAE-PFV| 16.7| 40.5| 33.1| 20.68| 35
XFAP-022Z-TFC| ZS15KAE-TF5| 16.7| 40.5| 33.1| 14.3| 20
XFAP-025Z-CFV| ZS19KAE-PFV| 16.7| 40.5| 33.1| 23.6| 40
XFAP-025Z-TFC| ZS19KAE-TF5| 16.7| 40.5| 33.1| 18.2| 30
XFAP-030Z-CFV| ZS21KAE-PFV| 16.7| 40.5| 33.1| 30.05| 50
XFAP-030Z-TFC| ZS21KAE-TF5| 16.7| 40.5| 33.1| 20.05| 30
XFAP-033Z-CFV| ZS26KAE-PFV| 16.7| 40.5| 33.1| 30.6| 50
XFAP-033Z-TFC| ZS26KAE-TF5| 16.7| 40.5| 33.1| 20.4| 30
XFAP-037Z-CFV| ZS29KAE-PFV| 16.7| 40.5| 33.1| 33.7| 50
XFAP-037Z-TFC| ZS29KAE-TF5| 16.7| 40.5| 33.1| 26.7| 45
XFAP-045Z-CFV| ZS33KAE-PFV|

2 FAN

| 16.7| 40.5| 48.9|

15.7

|

15.5

|

13.4

|

14.8

|

14.7

|

14.2

|

14.3

| 37.35| 60
XFAP-045Z-TFC| ZS33KAE-TF5| 16.7| 40.5| 48.9| 29.98| 50
XFAP-050Z-CFV| ZS38K4E-PFV| 16.7| 40.5| 48.9| 41.85| 70
XFAP-050Z-TFC| ZS38K4E-TF5| 16.7| 40.5| 48.9| 28.85| 45
XFAP-060Z-TFC| ZS45K4E-TF5| 16.7| 40.5| 48.9| 31.98| 50

Max Over-current rating applies to the condensing unit only. Additional evaporator fan or defrost heater loads must be considered. See evaporator manufacturer literature for additional load requirements.
† Defrost relay for single phase heaters only. For three-phase heaters, additional contactors are required.]

Capacity and Effi ciency

Medium Temp Capacity @ 95°F Ambient/25°F Evap, 65° RG; 5° subcooling

Model Number*|

Comp.

| R-134a| R-22| R-404A| R-407A| R-407C| R-448A              R-449A
Cap.| AWEF| Cap.| AWEF| Cap.| AWEF| Cap.| AWEF| Cap.| AWEF| Cap.| AWEF| Cap.| AWEF
XFAM-008Z-CFV| ZB06KAE| 4,830| –| –| –| 8,030| 7.6| 7,220| 7.6| 6,770| –| 7,390| 7.6| 7,400| 7.6
XFAM-008Z-TFC| ZB06KAE| 4,830| –| –| –| 8,030| 7.6| 7,220| 7.6| 6,770| –| 7,390| 7.6| 7,400| 7.6
XFAM-010Z-CFV| ZB07KAE| 5,870| –| –| –| 9,690| 7.6| 8,780| 7.6| 8,080| –| 8,780| 7.6| 8,790| 7.6
XFAM-010Z-TFC| ZB07KAE| 5,870| –| –| –| 9,690| 7.6| 8,780| 7.6| 8,080| –| 8,780| 7.6| 8,790| 7.6
XFAM-012Z-CFV| ZB08KAE| 6,880| –| –| –| 11,000| 7.6| 10,200| 7.6| 9,370| –| 10,300| 7.6| 10,300| 7.6
XFAM-012Z-TFC| ZB08KAE| 6,880| –| –| –| 11,000| 7.6| 10,200| 7.6| 9,370| –| 10,300| 7.6| 10,300| 7.6
XFAM-015Z-CFV| ZS09KAE| 7,810| –| 12,400| –| 12,400| 7.6| 11,400| 7.6| 10,900| –| 10,700| 7.6| 10,700| 7.6
XFAM-015Z-TFC| ZS09KAE| 7,810| –| 12,400| –| 12,400| 7.6| 11,400| 7.6| 10,900| –| 10,700| 7.6| 10,700| 7.6
XFAM-017Z-CFV| ZS11KAE| 9,270| –| 14,100| –| 14,400| 7.6| 13,500| 7.6| 12,900| –| 12,800| 7.6| 12,800| 7.6
XFAM-017Z-TFC| ZS11KAE| 9,270| –| 14,100| –| 14,400| 7.6| 13,500| 7.6| 12,900| –| 12,800| 7.6| 12,800| 7.6
XFAM-020Z-CFV| ZS13KAE| 10,500| –| 16,000| –| 17,000| 7.6| 15,300| 7.6| 14,600| –| 14,500| 7.6| 14,500| 7.6
XFAM-020Z-TFC| ZS13KAE| 10,500| –| 16,000| –| 17,300| 7.6| 15,300| 7.6| 14,600| –| 14,600| 7.6| 14,600| 7.6
XFAM-022Z-CFV| ZS15KAE| 12,600| –| 18,700| –| 20,300| 7.6| 18,300| 7.6| 17,500| –| 17,300| 7.6| 17,300| 7.6
XFAM-022Z-TFC| ZS15KAE| 12,600| –| 18,700| –| 20,300| 7.6| 18,300| 7.6| 17,500| –| 17,400| 7.6| 17,300| 7.6
XFAM-025Z-CFV| ZS19KAE| 14,100| –| 21,000| –| 21,700| 7.6| 20,400| 7.6| 19,600| –| 19,200| 7.6| 19,200| 7.6
XFAM-025Z-TFC| ZS19KAE| 14,300| –| 21,000| –| 21,600| 7.6| 20,400| 7.6| 19,600| –| 19,200| 7.6| 19,200| 7.6
XFAM-030Z-CFV| ZS21KAE| 18,700| –| 27,600| –| 28,200| 7.6| 26,300| 7.6| 25,800| –| 26,500| 7.6| 26,500| 7.6
XFAM-030Z-TFC| ZS21KAE| 18,700| –| 27,600| –| 28,200| 7.6| 26,300| 7.6| 25,800| –| 26,500| 7.6| 26,500| 7.6
XFAM-033Z-CFV| ZS26KAE| 20,600| –| 30,300| –| 31,700| 7.6| 29,300| 7.6| 28,400| –| 28,100| 7.6| 28,100| 7.6
XFAM-033Z-TFC| ZS26KAE| 20,600| –| 30,300| –| 30,700| 7.6| 29,100| 7.6| 28,400| –| 28,700| 7.6| 28,700| 7.6
XFAM-037Z-CFV| ZS29KAE| 22,800| –| 33,500| –| 35,300| 7.6| 31,800| 7.6| 31,400| –| 32,500| 7.6| 32,500| 7.6
XFAM-037Z-TFC| ZS29KAE| 22,800| –| 33,500| –| 34,200| 7.6| 31,800| 7.6| 31,400| –| 33,300| 7.6| 33,300| 7.6
XFAM-045Z-CFV| ZS33KAE| 25,600| –| 37,900| –| 39,100| 7.6| 36,800| 7.6| 35,400| –| 36,800| 7.6| 36,800| 7.6
XFAM-045Z-TFC| ZS33KAE| 25,600| –| 37,900| –| 39,100| 7.6| 36,800| 7.6| 35,400| –| 36,800| 7.6| 36,800| 7.6
XFAM-050Z-CFV| ZS38K4E| 30,300| –| 43,000| –| 46,700| 7.6| 43,600| 7.6| 42,900| –| 44,500| 7.6| 44,500| 7.6
XFAM-050Z-TFC| ZS38K4E| 29,400| –| 43,000| –| 46,700| 7.6| 43,600| 7.6| 42,900| –| 44,500| 7.6| 44,500| 7.6
XFAM-060Z-TFC| ZS45K4E| 35,000| –| 51,500| –| 53,000| 7.6| 51,500| 7.6| 51,000| –| 52,500| 7.6| 52,500| 7.6
Digital
XFAM-030D-CFV| ZBD21KCE| –| –| –| –| 27,000| 7.6| 24,000| 7.6| 23,200| –| 24,600| 7.6| 24,600| 7.6
XFAM-030D-TFC| ZBD21KCE| –| –| –| –| 27,000| 7.6| 24,000| 7.6| 23,200| –| 24,600| 7.6| 24,600| 7.6
XFAM-040D-TFC| ZBD30KCE| –| –| –| –| 36,900| 7.6| 35,400| 7.6| 32,200| –| 34,000| 7.6| 34,000| 7.6
XFAM-050D-CFV| ZBD38KCE| –| –| –| –| 45,300| 7.6| 44,400| 7.6| 40,100| –| 42,500| 7.6| 42,500| 7.6
XFAM-050D-TFC| ZBD38KCE| –| –| –| –| 45,300| 7.6| 44,400| 7.6| 40,100| –| 42,500| 7.6| 42,500| 7.6
XFAM-060D-TFC| ZBD45KCE| –| –| –| –| 52,000| 7.6| 49,100| 7.6| 46,700| –| 49,400| 7.6| 49,400| 7.6

*Data for XFAM models also applies to equivalent XFAP models.
This refrigeration system is designed and certifi ed for use in walk-in cooler applications. See Emerson.com/OPI for complete specifi cations.

Low Temp Capacity @ 95°F Ambient/-10°F Evap

Model Number*|

Compressor

| R-404A| R-407A| R-407C| R-448A / 449A| 507A
Cap.| AWEF| Cap.| AWEF| Cap.| AWEF| Cap.| AWEF| Cap.| AWEF
XFAL-008Z-CFV| ZF03KAE| 4230| 2.92| 3590| 2.89| 3360| –| 3740| 2.9| 4230| –
XFAL-008Z-TFC| ZF03KAE| 4230| 2.92| 3580| 2.89| 3360| –| 3740| 2.9| 4230| –
XFAL-009Z-CFV| ZF04KAE| 5770| 2.98| 4890| 2.94| 4540| –| 5080| 2.95| 5770| –
XFAL-009Z-TFC| ZF04KAE| 5770| 2.98| 4890| 2.94| 4540| –| 5080| 2.95| 5770| –
XFAL-010Z-CFV| ZF05KAE| 6960| 3.04| 5780| 2.98| 5390| –| 6020| 2.99| 6960| –
XFAL-010Z-TFC| ZF05KAE| 6960| 3.04| 5780| 2.98| 5390| –| 6020| 2.99| 6960| –
XFAL-012Z-CFV| ZF07KAE| 10700| 3.15| 9020| 3.13| 8210| –| 9070| 3.14| 10700| –
XFAL-012Z-TFC| ZF07KAE| 10700| 3.15| 9020| 3.13| 8210| –| 9070| 3.14| 10700| –
XFAL-020Z-CFV| ZXI06KCE| 12910| 3.15| 9230| 3.15| 9110| –| 11290| 3.15| 12910| –
XFAL-020Z-TFC| ZXI06KCE| 12910| 3.15| 9230| 3.15| 9110| –| 11290| 3.15| 12910| –
XFAL-030Z-TFC| ZXI09KCE| 16800| 3.15| 13450| 3.15| 11050| –| 13930| 3.15| 16800| –
XFAL-035Z-CFV| ZXI11KCE| 18900| 3.15| 15120| 3.15| 14560| –| 17200| 3.15| 18900| –
XFAL-035Z-TFC| ZXI11KCE| 18900| 3.15| 15120| 3.15| 14560| –| 17200| 3.15| 18900| –
XFAL-040Z-CFV| ZXI14KCE| 24210| 3.15| 21080| 3.15| 19760| –| 22870| 3.15| 24210| –
XFAL-040Z-TFC| ZXI14KCE| 24210| 3.15| 21080| 3.15| 19760| –| 22870| 3.15| 24210| –
XFAL-050Z-TFC| ZXI15KCE| 26620| 3.15| 22170| 3.15| 20530| –| 25660| 3.15| 26620| –
XFAL-051Z-CFV| ZXI16KCE| 26620| 3.15| 22170| 3.15| 20530| –| 25660| 3.15| 26620| –
XFAL-060Z-TFC| ZXI18KCE| 33720| 3.15| 29270| 3.15| 25380| –| 27680| 3.15| 33720| –

*Data for units containing ZF compressors are rated at 40-degree return gas; ZI compressors are rated at 65-degree return gas
This refrigeration system is designed and certified for use in walk-in freezer applications. See Emerson.com/OPI for complete specifications.

Condensing unit performance, electrical, and mechanical information can be accessed online at Climate.Emerson.com/OPI via Online Product Information (OPI).

About Emerson

Emerson (NYSE: EMR), headquartered in St. Louis, Missouri (USA), is a global technology and engineering company providing innovative solutions for customers in industrial, commercial, and residential markets. Our Emerson Automation Solutions business helps process, hybrid, and discrete manufacturers maximize production, protect personnel and the environment while optimizing their energy and operating costs. Our Emerson Commercial and Residential Solutions business helps ensure human comfort and health, protect food quality and safety, advance energy efficiency, and create sustainable infrastructure. For more information visit Emerson.com.Climate.

Emerson.com/CopelandOutdoorUnit
2009IP-50 R10 (7/20) Emerson and Copeland are trademarks of Emerson Electric Co. or one of its affiliated companies. ©2020 Emerson Climate Technoligies, Inc. All rights reserved.

EMERSON.CONSIDER IT SOLVED.

Documents / Resources

| EMERSON Copeland Outdoor Refrigeration Unit X-Line Series [pdf] Instruction Manual
Copeland Outdoor Refrigeration Unit X-Line Series
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Emerson User Manuals

Related Manuals