Bestway FLOWCLEART Filter Pump Owner’s Manual
- June 7, 2024
- Bestway
Table of Contents
#58385E
Intertek
4007787
FLOWCLEAR™ FILTER PUMP
OWNER’S MANUAL
www.bestwaycorp.com
Visit the Bestway YouTube channel
<http://www.bestwaycorp.com>
WARNING
IMPORTANT SAFETY
INSTRUCTIONS
INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions
should
always be followed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS
WARNING – RISK OF ELECTRIC SHOCK – The pump cannot be used while people
are inside the pool.
WARNING – TO REDUCE THE RISK OF INJURY , do not permit children to use
this product unless they are closely supervised at all times.
WARNING – RISK OF ELECTRIC SHOCK. Connect only to a grounding-type
receptacle.This product is provided with a ground-fault circuit interrupter.
If replacement
of the plug is needed, use only identical replacement parts.
WARNING: The unit is provided with a ground-fault circuit interrupter
(GFCI). To test the GFCI, push the test button. The GFCI should interrupt
power. Push the reset
button. Power should be restored. If the GFCI fails to operate in this manner,
the GFCI is defective. If the GFCI interrupts power to the pump without the
test button being pushed, a ground current is flowing, indicating the
possibility of an electric shock. Do not use this pump. Disconnect the pump
and have the problem corrected by a qualified service representative before
using it.
CAUTION – To reduce the risk of electric shock the pool must be installed
no closer than 6 feet (1.8 m) from any electrical outlet. Do not place
portable appliances closer than 5 feet (1.5 m) from the pool.
WARNING: The pump is not intended to be bonded to the equipotential
bonding grid.
DO NOT BURY THE CORD. Locate cord to minimize abuse from lawnmowers,
hedge trimmers, and other equipment.
WARNING – To reduce the risk of electric shock, the supply cord cannot be
replaced. If the cord is damaged the appliance should be scrapped.
WARNING – To reduce the risk of electric shock, do not use an extension
cord to connect the unit to the electric supply; provide a properly located
outlet.
CAUTION – This pump is for use with storable pools only. Do not use with
permanently installed pools. A storable pool is constructed so that it is
capable of being
readily disassembled for storage and reassembled to its original integrity. A
permanently installed pool is constructed in or on the ground or in a building
such that it cannot be readily disassembled for storage.
CAUTION – For continued protection against possible electric shock this
unit is to be mounted to the base in accordance with the installation
instructions.
IMPORTANT – Using the pump with an unmatched electrical supply is
dangerous and will result in catastrophic failure of the pump.
RISK OF ELECTRIC SHOCK – When working with electricity, turn the
electrical power off at the circuit breaker and lock the breaker door. Failure
to do so will result in an increased risk of shock, injury, and possibly
death.
DO NOT REMOVE THE GROUNDING PRONG OR MODIFY THE PLUG IN ANY WAY.
DO NOT USE ADAPTOR PLUGS. Consult a qualified electrician for any
questions related to the validity of your plugs grounding. Handle the pump
with care. Do not pull or carry the pump by the power cord. Never pull a plug
from the outlet by yanking the power cord. Keep cord free from abrasions.
Sharp objects, oil, moving parts, and heat should never be exposed to the
filter pump.
NOTE: Please examine equipment before use. Notify Bestway at the customer
service address listed on this manual for any manufacturing defect or missing
parts at the time of purchase. Verify that the equipment components represent
the filter pump model that you had intended to purchase.
NOTE: Place the pump on solid and level ground. Pay attention to the
position of the pool and pump so adequate ventilation, drainage, and access
for cleaning is available. Never place a pump in an area that may accumulate
water, or in an area where foot traffic will flow around the pool.
NOTE: Atmospheric conditions may affect the performance and life span of
your filter pump. Unnecessary wear and tear may occur during periods of cold,
heat, and exposure to the sun. Whenever possible shelter the pump from these
conditions.
NOTE: Do not add chemicals in the filter pump.
NOTE: Assembly and disassembly of this product should only be performed
by adults.
- THERMALLY PROTECTED MOTOR CSA ENCLOSURE 3
- FOR USE WITH SWIMMING POOLS ONLY.
- CAUTION: TO ENSURE CONTINUED PROTECTION AGAINST SHOCK HAZARDS, USE ONLY IDENTICAL REPLACEMENT PARTS WHEN SERVICING.
- WARNING: RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A GROUNDING-TYPE RECEPTACLE.
- CAUTION: THIS PUMP IS FOR USE WITH STORABLE POOLS ONLY – DO NOT USE WITH PERMANENTLY INSTALLED POOLS.
- CAUTION: CONNECT ONLY TO GROUNDING-TYPE RECEPTACLE PROTECTED BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER.
- CAUTION: FOR CONTINUED PROTECTION AGAINST POSSIBLE ELECTRIC SHOCK THIS UNIT IS TO BE MOUNTED TO THE BASE IN IN ACCORDANCE WITH THE INSTALLATION INSTRUCTIONS.
- WARNING – RISK OF ELECTROCUTION
- Connect Only To Properly Grounded Outlet. Do Not Remove Ground Pin
- Inspect Cord Before Using – Do Not Use If Cord Is Damaged.
- Keep Ground-Fault Circuit-Interrupter Dry And Off The Ground
- Do Not Touch Plug With Wet Hands
- Double Insulated – When Servicing Use Only Identical Replacement Parts.
- Read Instruction Manual Before Using.
DO NOT REMOVE THIS TAG
SAVE THESE INSTRUCTIONS.
PEDESTAL FIXING
The filter pump must be vertically fixed on the ground or a certain pedestal made of wood or concrete before use. There should be two holes 9mm in diameter on the pedestal, the space between which should be 159mm. Put the filter pump on the pedestal and fix them together by fastening the bolts and nuts. All the pedestal parts should weigh over 18kgs at least to prevent the pump from accidentally falling.
Operation
- Open/unscrew the Air Purge Valve (P6112) on the top of the Filter Pump; the air is released as water fills the Filter Pump.
- When water comes out of the Air Purge Valve (P6112) screw it closed and wipe away any water.
- Test the GFCI plug.
NOTE: It is imperative to check that the hydraulic connectors are not closed.
GFCI Test
A. To test the GFCI plug, insert it into a grounding-type receptacle.
B. Press the “RESET” button; the indicator turns red.
NOTE: If the indicator light is not on, the test has failed.
C. Press the “TEST” button. The indicator turns off.
NOTE: If the indicator light is not off, the test has failed.
D. Press the “RESET” button, the indicator light turns red, and the filter
pump is ready for use.
WARNING : RISK OF ELECTRIC SHOCK. THE GFCI MUST BE TESTED BEFORE EACH
USE.
WARNING : DO NOT USE THE PUMP IF THE ABOVE TEST FAILS.
Please contact your local Bestway Aftersales Service.
NOTE: To prevent the risk of electrical shock, ensure your hands are
completely dry when plugging in the Filter Pump.
IMPORTANT: DO NOT DRY RUN THE FILTER PUMP – Make sure both the pool’s
Inlet and Outlet valves are fully covered by water before operating the Filter
Pump.
Maintenance
CAUTION: YOU MUST ENSURE THE FILTER PUMP IS UNPLUGGED BEFORE ANY
MAINTENANCE OR STORAGE BEGINS OR SEVERE RISK OF INJURY OR DEATH EXISTS.
-
Unplug the Filter Pump.
-
Loosen the Hose Clamps on the pool’s Inlet and Outlet Hoses by unscrewing the fly nut counter-clockwise.
-
Remove Debris Screens from the inside of the pool.
-
Replace the Debris Screens with the Stopper Plugs in the pool’s Inlet and Outlet Valves.
-
Unscrew the Filter Cap Retainer and remove the Filter Cap.
-
Clean the Filter Cartridge with a garden hose, if the filter cartridge remains soiled or discolored, it is necessary to replace it with a new one.
-
Insert the cleaned (or new) Filter Cartridge; ensure it is centered in the Filter Pump.
-
Check that the Filter Cap Seal is in place.
-
Replace the Filter Cap and screw the Filter Cap Retainer into position.
-
Replace the Stopper Plugs with the Debris Screens in the pool’s Inlet and Outlet Valves. Tighten the Hose Clamps. Water will now
flow to the pump. -
Follow the PUMP INSTALLATION DIRECTIONS section to prepare the system for use.
IMPORTANT: For sanitary reasons, we suggest replacing the Filter
Cartridge with a new one every two weeks.
STORAGE
- Unplug the Filter Pump.
- Follow the instructions as previously outlined to stop water flowing to the Filter Pump and to remove the Filter Cartridge.
- Discard the Filter Cartridge.
- Detach all Hoses.
- Dry all components thoroughly.
- Store the filter pump in a dry location out of the reach of children. Storage temperature: 4-40 O C (39.2-104OF)
Pump Warranty
For information concerning pump warranty please visit our website at: www.bestwaycorp.com
Limited BESTWAY®anufacturer’s Warranty
The product you have purchased comes with a limited warranty. Bestway®stands
behind our quality guarantee and assures, through a replacement warranty,
your product will be free from manufacturer’s defects that result in leaks.
The limited warranty is valid as follows: 360 days for the motor pumps from
the original date of purchase, 30 days for hoses, fitting, and accessory
included in the package all from the original date of purchase To enact a
warranty claim, this form must be completed and supplied with a copy of your
receipt/purchase to your local Bestway After Sales Center. Please contact your
local Bestway After Sales Center before sending any documents. They will
provide full instructions of what is needed for your claim. Bestway®is not
responsible for economic loss due to water or chemical costs and will not
replace any products deemed to have been damaged due to negligence or having
been used outside of the owner’s manual guidelines.
Bestway’s warranty covers manufacturing defects discovered while unpacking the
product or during use as recommended within the user manual. This warranty
applies only to products that have not been modified by any 3rd parties. The
product must be stored and handled in accordance with the technical
recommendations.
The warranty does not cover damages caused by misuse, abuse, neglect,
including, but not limited to collision, fire, use of incorrect voltage,
excessive heat exposure, improper installation, improper wiring or testing, or
improper storage.
Replacements and repairs don’t extend the duration of the warranty. The
warranty start date is the date of sale shown on the original receipt/purchase
invoice.
Please copy the Batch Number found on the body of the filter pump.
Batch Number:…………. | Date:……………… |
---|---|
Date of purchase:………. | Customer Code Number:………… |
TO: Bestway ®Service Department
FAX/E-MAIL/TEL: Please refer to your country according to the information
found on the back cover or on our website:
www.bestwaycorp.com
Please provide your address details in full. Note: Incomplete address details
will result in delayed shipments.
Bestway reserves the right to charge for re-delivery of undelivered packages
where the recipient is at fault.
REQUIRED INFORMATION – PLEASE WRITE THE SHIPPING ADDRESS
Name: | Address: |
---|---|
Zip Code: | Retailer: |
Country: | City: |
Mobile: | Telephone: |
Fax: | E-mail: |
Please Clearly Write Your Item Code:
All drawings for illustration purposes only. Not to scale.
IMPORTANT: ONLY THE DAMAGED PART WILL BE REPLACED, NOT THE COMPLETE SET.
Bestway reserves the right to request photographic evidence of defective
parts, or to require sending the item for additional testing.
In order to best assist you, we request all information you provide to be
complete.
FOR FAQ, MANUALS, VIDEOS OR SPARE PARTS, PLEASE VISIT OUR
WEBSITE:www.bestwaycorp.com
VIDEOS ARE ALSO AVAILABLE ON OUR BESTWAY CHANNEL ON YOUTUBE
:www.youtube.com/user/BestwayService
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>