LEEDARSON Motion sensor Pet Immunity Z
Wave™
7CA-SS-VE-C0
Motion Sensor Pet immunity
Quick Start Guide
Product Introduction
The Motion Sensor lets you know when movement is detected in a certain area
and can trigger different actions in response to that movement (or lack of
movement). It supports the pet immunity up to 80 lbs. This sensor integrated
Z-Wave communication module to connect with Z-Wave gateway, and this device
can be adapted to EU(868.42Mhz) or US(908.42MHz).
If you want your Motion Sensor to be a security device that use
secure/encrypted message to communicate in a Z-Wave network, then a security
enabled Z-Wave controller is needed.
The motion sensor can be included and operated in any Z-Wave network with
other ZWave certified devices from other manufacturers and/or other
applications. All non-battery operated nodes within the network will act as
repeaters regardless of vendor to increase reliability of the network.
Product Appearance
Product appearance and function overview.
Button:
- Short press reset button into learning mode, then the sensor can inclusion or exclusion from the Z-Wave network.
- Hold the key for 5s to reset the sensor, after reset, Sensor will send “Device_Reset_Locally” to the main controller and exclude from the Z-Wave network when the Button is released, this procedure will reset the Sensor to factory default.
- Short press button for 3 times then the sensor sending wake up notification on to gateway, and LED will fast blink when sending data, send over then the L ED turn off.
Specification
Detection angle| 80 degrees
Detection distance| 8 meters / 26.25 feet
Mounting height| 6.23 ft. to 7.55 ft.
(1.9m to 2.3m)
Light sensor| 20 lux for day/night(bright/dark)
Protocol| Z-Wave
Frequency| 908.42MHz (US)
868.42MHz(EU)
Power source| Battery-powered
Battery type| CR123A X 1
Battery life| 3 years
Anti-Tamper| YES
Low power alarm| YES
Certifications| CE/FCC/Z-Wave
| Battery-powered
Features/Capabilities:
- Supports pet immunity up to 80 lbs (36 kgs)
- Use PIR & Fresnel lens technology
- Easy installation with bracket
- Low battery alarm
- Equipped with an anti-tamper switch that reports any tampering
Installation Position and Notes
-
Installation position should be chosen at the area which the bass-by will be across, try to make the bass-by in the detection area as below.
Side view
Top view -
Do avoid installation near air-conditioner, electric fans, refrigerators, ovens or other places where temperature easy change.
-
In order not to affect the detecting result, there should be no object in front of the produces lens.
-
Building (such as the wall) will shorten the distance of wireless communication. 5. This device can be mounted on the wall only, it cannot be installed on the ceiling.
Product Installation
Adding the device as accessories, install it according to the diagram below:
- Choose the installation location on the wall, fix the bracket by screw or 3M adhesion tape on the wall.
- Take off the bracket in the back, and draw out the battery insulation sheet, then assembly the bracket.
- Assembly the main body to the bracket.
Product Usage
Function of Action Button:
-
All functions of each trigger:
Function Of Action Trigger| Description
---|---
Power on| In the network: Send Battery report and Wake up notification, the LED turn on within 1 second.
Not in the network: Only the LED will be slow blink 3 times.
SmartStart Inclusion| Add the Motion Sensor into the Z-Wave network via SmartStart:
1. Add your Motion Sensor device to the primary controller’s SmartStart provisioning list (if you don’t know how to do this, refer to its manual) by scanning your device’s QR code
2. Power on the motion sensor again.
3. The motion will send “Z-Wave protocol Command Class” frame to start SmartStart Inclusion.
4. Led will fast blink and solid for 2 seconds to indicate the inclusion is successful, if inclusion failed, Led will off.
Short press button three time| Add the Motion Sensor into the Z-Wave network:
5. Power on your Motion Sensor, and let your Z-Wave controller into add/inclusion mode.
6. 3 consecutive clicks in 1.5 seconds, the Motion Sensor will send out a node info security CC in command class list (Security inclusion), the LED will be fast blink for 30 seconds.
7. If the inclusion is successful, the LED will be turn on within 2 seconds. If failed, LED will be turn off forever, and please repeat the steps in above. Remove Motion Sensor from a Z-Wave network:
1. Power on your Motion Sensor, and let the Z-Wave primary controller into remove mode.
2. 3 consecutive clicks in 1.5 second, the LED will be fast blink for 30 seconds.
3. If Motion Sensor has been successfully removed from your Z-Wave network, the LED will be turned on 2 seconds. If failed, LED will be turn off forever, and please repeat the steps in above.
Short press button one time| In the network: Send Wake up notification, and LED will fast blink when sending data, send over then the LED turn off.
Not In the network: NOP.
Press and hold more than 5 seconds| Reset Motion Sensor to factory default.
1. Triggering this action, in 5 seconds LED will accelerate blink. After 5 seconds, the LED will remain on until the key is released. Motion Sensor will send “Device_Reset_Locally” to the main controller and exclude it from the Z-Wave network when the button is released, this procedure will reset the sensor to factory default.
2. Please use this procedure only when the network primary controller is missing or otherwise inoperable.3. When not in the network, triggering this action, in 5 seconds LED will accelerate blink red. After 5 seconds, the LED will remain on red until the key is released. this procedure will reset the sensor to factory default.
Motion is triggered| In the network: Send Notification report and Sensor multilevel report and Basic set (Setup configuration parameter 0x0E to 0x01), and the LED will be turned on 0.2 second.
Not in the network: Motion sensor is disabled.
Tamper switch is triggered| In the network: Send Notification report, and the LED will be turned on 0.2 seconds.
Not in the network: Tamper switch is disabled. -
Caution:
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Hereby, Corporation declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU -
Low voltage alarm to remind changing battery.
This product has low voltage detection reminder, when the battery voltage is in low status, the detector will give out low battery signal to controller.
Attention
- If need to clean the sensor, please use a soft cloth with a little alcohol to wipe it after you cut off the power.
- This product is just for indoor use.
- Replace the battery timely on low battery warning to ensure the detector works properly. Please remove the battery and safe keeping, if you don’t use this product for a long time.
- This device can be mounted on the wall only, it cannot be installed on the ceiling.
- The reference range template of PIR detection is tested at the indoor temperature (the range is 2025)the target of the test is 77kg±10kg weight and 1.71m±0.3m height, the target of the test across movement speed is 4m/s±0.15m/s.
- In order to prevent the PIR sensor’s abnormal fault, please don’t mounting and operating sensor in the bellow conditions, Firstly, product mounting should prevent installed in the airflow environment such as in front of the door, window, heater, air conditioner and so on. Secondly, the PIR detection area should not be shielded by another screen. Thirdly, if the operating temperature range is out of the defined range of product specification may result in some product faults, which is not in the technique commitment of manufacturer. Fourthly, this product has mot pet immunity function, so when some animals go through in front of the product may trigger PIR function reported.
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS
Dispose of the device separately from household waste at an official collection point. Professional recycling protects people and the environment against potential Negative effects.
Command Class List
| Non-Included Non-Secure| Included S0 Non-Secure
---|---|---
Node Info
Frame
| COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_VERSION
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_BATTERY
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_NOTIFICATION_V3
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_WAKE_UP
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_CONFIGURATION_V4
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5
| COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVISION
Security Command
Supported Report
Frame
| | COMMAND_CLASS_VERSION
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_BATTERY
COMMAND_CLASS_NOTIFICATION_V3
COMMAND_CLASS_WAKE_UP
COMMAND_CLASS_CONFIGURATION_V4
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5
| Included S2 Non-Secure|
Node Info
Frame
| COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_TRANSPORT_SERVICE
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVISION
|
Security
CommandSupported
Report Frame
| COMMAND_CLASS_VERSION
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_BATTERY
COMMAND_CLASS_NOTIFICATION_V3
COMMAND_CLASS_WAKE_UP
COMMAND_CLASS_CONFIGURATION_V4
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5
|
Association Command Class
Motion Sensor supports 2 association groups and max 5 nodes for each group.
Association Group Info Command Class
Association Group Info
Grouping identifier | Group Name | Profile MS | Profile LS |
---|---|---|---|
01 | Lifeline | 0x00 | 0x01 |
02 | On/Off control | 0x71 | 0x07 |
Association Group Command
Group 1 | Command List Support |
---|---|
Command Class | COMMAND_CLASS_NOTIFICATION_V8(0x71) |
Command | NOTIFICATION_REPORT_V8(0x05) |
Command Class | COMMAND_CLASS_BATTERY(0x80) |
Command | BATTERY_REPORT(0x03) |
Command Class | COMMAND_CLASS_DEVICE_RESET_LOCALLY(0x5A) |
Command | DEVICE_RESET_LOCALLY_NOTIFICATION(0x01) |
Command Class | COMMAND_CLASS_SENSOR_MULTILEVEL_V5(0x31) |
Command | SENSOR_MULTILEVEL_REPORT(0x05) |
Group 2 | Command List Support |
Command Class | COMMAND_CLASS_BASIC(0x20) |
Command | BASIC_SET(0x01) |
Notification Commands
Notification Type | Notification Event |
---|---|
HOME_SECURITY (0x07) | (0x00) NO_EVENT |
(0x03) TAMPERING_COVERING_REMOVED
(0x08) MOTION_DETECTION_UNKNOWN_LOCATION
POWER_MANAGEMENT (0x08)| (0x0A) REPLACE_BATTERY_SOON
(0x0B) REPLACE_BATTERY_NOW
(0x00) NO_EVENT
LIGHET_ALARM(0x14)| (0x00) NO_EVENT
(0x01) LIGHETSENSOR_ALARM_DETECTED
Configuration Set Command Class
Command Format
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
---|
Command Class = COMMAND CLASS CONFIGURATION
Command = CONFIGURATION SET
Parameter Number
Default| Reserved| Size
Configuration Value 1(MSB)
Configuration Value 2
……
Configuration Value n(LSB)
Parameter Number Definitions (8 bit)
Name| Info| Paramet
er
Number
| Default
Value
| Max
Value
| Min
Value
| Size| Read-
only
| Format| Altering
capabilit
ies
---|---|---|---|---|---|---|---|---|---
LowBatPrecent| LowBatAlarm| 0x0A
(10)
| 10
(0x0A)
| 50
(0x32)
| 5
(0x05)
| | NOT
Read-
only
| UNSIGNED
_INTEGER
| Will alters
capabilities
Pironoff| PironoffSet| 0x0C
(12)
| 1
(0X01)
| 1
(0X01)
| 0
(0X00)
| 1| NOT
Read-
only
| UNSIGNED
_INTEGER
| Will alters
capabilities
PirTimeout| PirTimeoutSet| 0x0D
(13)
| 60
(0X3C)
| 15300
( 0x3BC
| 05
(0x05)
| 1| NOT
Read-
only
| UNSIGNED
_INTEGER
| Will alters
capabilities
BasicEnable| SendBasic| 0x0E
(14)
| 0
(0X00)
| 1
(0X01)
| 0
(0X00)
| 2| NOT
Read-
only
| UNSIGNED
_INTEGER
| Will alters
capabilities
BasicReverse| BasicValue| 0x0F
(15)
| 0
(0X00)
| 1
(0X01)
| 0
(0X00)
| 1| NOT
Read-
only
| UNSIGNED
_INTEGER
| Will alters
capabilities
PirSensitivity| PirSensitivitySet| 0x10
(16)
| 9
(0X09)
| 10
(0X0A)
| 0
(0X00)
| 1| NOT
Read-
only
| UNSIGNED
_INTEGER
| Will alters
capabilities
PirPetImmunity| PirPetImmunitySet| 0x11
(17)
| 0
(0X00)
| 1
(0X01)
| 0
(0X00)
| 1| NOT
Read-
only
| UNSIGNED
_INTEGER
| Will alters
capabilities
LightSensorSend
Type
| LightSensorSendSet| 0x12
(18)
| 1
(0X01)
| 3
(0X03)
| 1
(0X01)
| 1| NOT
Read-
only
| UNSIGNED
_INTEGER
| Will alters
capabilities
Parameter Number description
Parameter
Number
| Description
---|---
0x0A (10)| Low battery power level of alarm threshold values: the value range
are 5~50 for percentage, the battery low power level can setting 5%~50%.
0x0C(12)| Enable/Disable the PIR
0 = Disable the PIR.
1 = Enable the PIR.
0x0D (13)| Setup the wait time of PIR for clear the motion.
Valid values: 0x05~0x3BC4
0x0E (14)| When the Motion Sensor is triggered, if this parameter is
0x01 then it will send Basic set command to group 1.
0 = Don’t send.
1 = Send.
0x0F (15)| PIR triggers the correspondence between the value of the Basic set and the PIR state.
-If this value is 0x00 :
PIR triggers send the basic set with 0xFF, PIR alarm release send the basic set with 0x00.
-If this value is 0x01 :
PIR triggers send the basic set with 0x00, PIR alarm release send the basic set with 0xFF.
Only support 0x00 and 0x01 values as valid value.
0x10 (16)| Motion detection sensitivity level is a value between 1 and 10. This value affects the amount of motion energy required to generate a motion event and also affects the detection range and angle.
1 = Lowest Motion Sensitivity
10 = Highest Motion Sensitivity
0x11 (17)| Enable/disable pet immunity mode. This feature is lens dependent and detection range may be reduced when Pet Immunity is enabled.
0 = Disable the pet immunity mode
1 = Enable the pet immunity mode
0x12 (18)| Configure lightsensor to upload data form
1=Upload lumens value.
2=Upload day or night(By notification).
3=Upload lumens and day/night .