Nature POWER Monocrystalline Solar Panel User Manual
- June 7, 2024
- Nature POWER
Table of Contents
Monocrystalline Solar Panel
User Manual
WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious personal injury.
SAVE THESE INSTRUCTIONS
Important Safety Information
Thank you for choosing a Nature Power Product.
Save the receipt and these instructions. It is important that you read the
entire manual to become familiar with this product before you begin using it.
This product is designed for certain applications only. the distributor cannot
be responsible for issues arising from modification. We strongly recommend
this product not be modified and/or used for any application other than that
for which it was designed. If you have any questions relative to a particular
application, Do not use the product until you have first contacted the
distributor to determine if it can or should be performed on the product.
For technical questions please call 1800-588-0590
⚠ WARNING
-
Read and understand all instructions. Failure to follow all instructions may result in serious injury or property damage.
-
The warnings, cautions, and instructions in this manual cannot cover all possible conditions or situations that could occur. Exercise common sense and caution when using this tool. Always be aware of the environment and ensure that the tool is used in a safe and responsible manner.
-
Do not allow persons to operate or assemble the product until they have read this manual and have developed a thorough understanding of how it works.
-
Do not modify this product in any way. Unauthorized modification may impair the function and/or safety and could affect the life of the product. There are specific applications for which the product was designed.
-
Use the right tool for the job. DO NOT attempt to force small equipment to do the work of larger industrial equipment. There are certain applications for which this equipment was designed. It will be a safer experience and do the job better at the capacity for which it was intended.
DO NOT use this equipment for a purpose for which it was not intended. -
Industrial or commercial applications must follow OSHA requirements.
WARNING
This product can expose you to chemicals, including Di (2-Ethylhexyl)
phthalate (DEHP) which is known to the State of California to cause cancer,
birth defects, or other reproductive harm. For more information, go to
www.p65warnings.ca.gov
ADVERTENCIA
Este producto puede exponerlo a productos químicos, incluidos Di (2-etilhexil)
ftalato (DEHP)que el estado de California sabe que causa cáncer, defectos de
nacimiento u otros daños reproductivos. Para obtener más información, vaya a
www.p65warnings.ca.gov
Cautions
- Never touch the end of output cables with your bare hands when the modules are irradiated. Handle wires with rubber-gloved hands to avoid electric shock
- Do not wear metallic jewelry when working on electrical equipment
- The product should be installed and maintained by qualified personnel
- Do not drop tools or other items on the glass of the solar module
- Do not scratch the back film of the solar panel
- Avoid exposing solar panels to partial sunlight or shadows. Partial sunlight can cause hot spots on the panel
- Do not pour chemicals on the module when cleaning. To clean use, a damp cloth do not apply excessive pressure to the cells
- Do not expose solar module to sunlight concentrated with mirrors, lenses, or similar means
- Keep module away from children
Precautions when working with batteries
- Never smoke or allow a spark or flame near the batteries
- Batteries generate hydrogen and oxygen during charging resulting in the evolution of explosive gas mixture. Care should be taken to ventilate the battery area and follow the battery manufacturer’s recommendations
- Batteries contain very corrosive diluted acid as electrolytes. Precautions should be taken to prevent contact with skin, eyes, or clothing
- Use caution to reduce the risk of dropping a metal tool on the battery. It could spark or short circuit the battery or other electrical parts and could cause an explosion
- Remove metal items like rings, bracelets, and watches when working with batteries. The batteries can produce a short circuit current high enough to weld a ring or the like to metal and thus cause a severe burn
- If you need to remove a battery, always remove the ground terminal from the battery first. Make sure that all the accessories are off so that you do not cause a spark
- Only use rechargeable 12 Volt batteries, ie. Sealed Lead Acid, Deep Cycle, Gel-Cell etc.
- Use properly insulated tools only when making battery connections
- When working with batteries please follow the battery’s manufacturer manual and precautions
Precautions when working with solar panels
With the incidence of sunlight or other light sources on all solar panels, a
voltage appears at the output terminals of the solar panel turning it into a
source f electricity. Do not make contact with the terminals when the panel is
exposed to sunlight or other light sources. To avoid shock hazards make sure
the solar panel is either turned over so the cells are not exposed to light or
cover the cells with an opaque (dark) material such as paper/cloth during the
installation process.
WARNING: Ensure that the positive matches the positive and the negative
matches the negative. ( Connections are in Parallel) Wrong connection may
cause sparks and void the warranty.
Parts List
Reference | Part Description | Quantity |
---|---|---|
1 | Solar panel with SAE connector wiring | 1 |
2 | SAE-Battery clamp cable | 1 |
3 | Mounting Z bracket set | 4 |
Technical Specifications
Rated electrical characteristics are within +10 percent of the indicated values of lsc, Voe, Pmax under Standard Test Conditions (irradiance of 100 mW/cm 2, AM 1.5 spectrum, and a cell temperature of 25 ℃ {77°F}). The electrical characteristics are based on the results of the outgoing test.
Pmax | 90W | 100W | 165W | 180W | 330W( |
---|---|---|---|---|---|
Voltage at Pmax (Vmp) | 17.5V | 17.5V | 17.5V | 17.5V | *kit consists of |
Current at Pmax (Imp) | 5.14A | 5.71A | 9.43A | 10.3A | 2 165W panels* |
Open Circuit Voltage (Voc) | 21.6V | 21.6V | 21.0V | 21.0V | |
Short Circuit Current (Isc) | 5.49A | 5.49A | 9.95A | 9.95A | |
Dimension | 32.6×26.5×1.2” | 32.6×26.5×1.2” | 57.8×26.5×1.4” | 57.8×26.5×1.4″ | |
Efficiency | 18.20% | 19.85% | 17.20% | 18.90% | |
Cell technology | Monocrystalline | ||||
Class | A | ||||
Weight | 21.1lbs | 21.1lbs | 25.3lbs | 25.3lbs |
Installation
- Open the packaging and check to make sure that all parts have been received.
- Arrange to have on hand the proper tools to carry out the mounting installation.
- Determine the mounting location of the solar panel(s). It is important the solar panel receive the maximum amount of sunlight during the day and not be shaded.
- Connecting a solar panel to battery for 12V charging.
- Mount the charge controller within 5 feet of battery or loss of current may occur.
- Wire the battery to the charge controller and then the solar panel to the charge controller to ensure that the correct polarity is observed.
- Secure the solar panel to the desired location, the solar panel must be within 20 feet of the battery, or loss of current may occur.
Easy Electrical Installation
Please confirm that you have all parts to your system before starting
installation. Figure 1 shows how to connect the solar panel to the 12 Volt
batteries
Step 1
Connect the charge controller to the solar panel
Step 2
Connect the battery clamps to the charge controller
Step 3
Connect the battery clamps to the battery in parallel. (Parallel connections=
Positive to Positive and Negative to Negative)
When installing solar panels configuration and systems, please carefully observe correct cable connections and polarity. The solar panels can be damaged by not observing the correct electrical installation and polarity; in addition, this will void the warranty of your solar panel(s). Having a multimeter handy will help to confirm correct polarities.
Extending the wiring
If you choose to mount your solar panel further away from the charge
controller by extending the wiring we recommend the following gauges at each
specified distance. Use stranded wire instead of solid wire. Stranded wire
does not fatigue or lose connections over time.
Appropriate wire gauge should be used for distance and total amperage, for
further information please consult with a licensed electrician or through an
online wiring chart calculator
Solar Panel Mounting
Mounting the Solar panels
Choose a site for mounting the solar panels that is free from shade and
located in an area that receives maximum sunlight daily. For maximum solar
power absorption throughout the day, a tilt-mounting kit is recommended.
The solar panels can be permanently installed level using the Z-brackets.
Measure the distance between the mounting site and the battery location. The
charge controller should be mounted in close proximity to the battery bank
(within 5 feet). Refer to the DC electrical wire guide to choose an
appropriate gauge wire for the length of the wire.
If you choose to mount your Solar Panel on your RV, be sure you solidly mount
your panels to the roof. If you have a rubber roof over thin plywood you may
want to use molly fasteners to get a better grip. If you have a fiberglass
roof, drill some pilot holes through the fiberglass to reach the plywood
below. This will prevent cracking or damaging the fiberglass. If your RV is
equipped with a metal roof you must mount the solar panel to the joists
supporting the roof. Figure 3 shows an example of how the panel can be mounted
with the z-brackets.
The wire from the solar panel can be routed to the interior of the RV through the roof-top refrigerator vent. In this kind of installation attempt to mount the panel near the refrigerator vent. See Figure 4.
Operating Instruction
Additional Solar Panels
- To connect 2 Solar Panels together simply remove the SAE connector at the end of each Solar Panel to reveal at least 2 inches of bare wiring.
- Once the two wires are exposed they can be connected together by either twisting the wires together or by using solder. When connecting the wires always ensure the correct polarity is observed, Negative (- Black) to Negative and Positive(+ Red) to positive.
- Once the wires are connected they can be placed in/on the correct terminals of your charge controller.
- Once the wires have been placed on their terminals correctly ensure the connection is safe and secure and that the bare wires cannot come into contact with each other. This can be done by using insulation tape or electrical tape that can be wrapped around the wires to stop them from coming into contact with one another.
Note: If the Solar Panel wires are short while being connected to the
Charge Controller it may cause irreparable damage. Removing the SAE connector
will not have the warranty on Solar Panels.
You can also contact nature power for a 2 in 1 SAE cable for 2 panels fast
connected.
Selecting the correct Battery
We do not offer batteries. However, please choose a 12 Volt rechargeable
battery. Do not attempt to recharge non-rechargeable batteries. 6 Volt battery
configurations may also be used if connected in series (Negative to Positive).
You may choose a Sealed Lead Acid battery, a Gel-Cell, or a Deep Cycle 12 Volt
battery. Batteries come in all different sizes, Please converse with your
battery dealer for more information on which type of battery you should use
for your system. Note your solar panel amperage rating when selecting your
battery size.
Additional 12V DC Batteries
Addition batteries may be desired for extra electrical storage.
For 12 Volt battery bank configurations; make sure your batteries are
connected in parallel (Positive to Positive and Negative to Negative)
- From the charge controller attach the red battery clamp to the red terminal of the first battery in the bank, matching the polarities, positive to positive.
- Then connect the black alligator clamp to the black terminal of the second or late battery in the bank, again matching polarities, negative to negative. This will ensure equal charging across both or all batteries.
Selecting the Correct Charge Controller
Charge Controllers may be sold separately and are required for installations
of solar systems arrays that are rated 12 Watts and higher. Charge Controllers
help to protect the battery(s) and solar panel(s) from harmful reverse
currents, battery overcharging and high wattage surges, additional protections
are
found on larger charge controllers.
If two or more solar panels are connected in series/parallel make sure that
the sum of the short circuit current ratings of all panel strings does not
exceed 80% of the charge controller’s current rating i.e. 8 Amps or 28 Amps.
8 Amp Charge Controller
is an easy-to-connect and easy-to-read charge controller with LED light
indicators for battery charging cut-in voltage 13V and battery full cut-out
voltage 14.2V. The 8 Amp Charge Controller is compatible with solar system
arrays rated up to 130 Watts.
Protections:
- Reverse Current
- Over Charge
- Low Voltage
- High Voltage surges
28 Amp Digital PWM Charge Controller
With Pulse Width Modulation (PWM) technology this charge controller helps to
maintain a higher charging efficiency, thus maintaining a higher battery
reserve and capacity than the standard on-off 8 Amp charge controller. The 28
Amp Digital PWM Charge Controller features a digital LCD display and
adjustable voltage settings.
Protections:
• Short Circuit | • Discharging |
---|---|
• Low Voltage | • Reverse Current |
• Overloading | • Discharging |
Connecting an Inverter
An inverter can be used to converting the 12 Volt energy created to 120 Volt
Electricity.
Inverter sizes and types vary depending on your power consumptions needs.
Please discuss which inverter to purchase with your Inverter dealer.
Run Times
Please refer to the run times chart to choose how much solar power your desired system requires. Note that all run times and ratings are approximate and may vary depending on your location and time of day and are based on 7 hours of full sunlight a day.
Rated Hourly (Maximum output)| 90 Watt| 100 Watt| 165
Waft| 180 Waft| 330 Watt
---|---|---|---|---|---
5.14 Amp| 5.71 Amp| 9.43 Amp| 10.28 Amp| 18.86 Amp
Weekly Output| 4410 Watts/ 251.86 Amps| 4900 Watts/ 279.79 Amps| 8085
Watts/ 462 Amps| 8820 Watts/ 501 Amps| 16170 Watts/ 924.14 Amps
Weekly Run Times
Laptop 20-50 watts| 88 hr| 98 hr| 160 hr| 176 hr| 320 hr
PC 80-150 watts| 29 hr| 32 hr| 50 hr| 59 hr| 100 hr
Television 19″ Color 70 watts| 63 hr| 70 hr| 110 hr| 126 hr| 220 hr
CD Player Radio 35 watts| 126 hr| 140 hr| 230 hr| 252 hr| 460 hr
Fan 10-50 watts| 83 hr| 98 hr| 165 hr| 176 hr| 330 hr
Halogen Light 100 watts| 44 hr| 49 hr| 80 hr| 88 hr| 160 hr
Fluorescent Light 40 watts| 110 hr| 122 hr| 200 hr| 220 hr| 400 hr
Coffee Maker 800 watts| 6 hr| 6 hr| 10 hr| 11 hr| 20 hr
Portable Heater 1500 watts| 3 hr| 3 hr| 5 hr| 6 hr| 10 hr
**Maintenance
**
Monitoring your Solar System
To confirm your solar panels are generating power we suggest purchasing a
multi-meter. Annual testing and inspections are recommended to confirm all
connections are secure and panels are functioning properly.
Open voltage testing of solar panels may range from 11 Volts up to 21.6 Volts
depending on the intensity of the sun, this is within the normal range.
Upon annual inspections, it is recommended to wipe all solar panels with a
damp towel to remove dust and debris covering the panels, as layers of dust
can affect the solar panel voltage.
Routine Maintenance Check List
- Check and replace damaged components if necessary
- Clean with a damp towel or cloth remove all debris
- Check and maintain the battery electrolyte levels are at regular intervals as per the battery manufacturer’s recommendations if flooded wet cell lead-acid batteries are used
- Check solar panel open voltage range
- Check solar panel close circuit range
- Confirm all wiring connections are secure and tight
- Confirm all mounting connections are secure and tight
Limited Warranty
Nature Power warrants our products to the original purchaser that this product is free from defects in materials and workmanship for the period of 1 year from date of purchase, 25 years warranted to generate up to 80% of rated power from the date of purchase. In the case of a product defect, contact Nature Power customer service to receive troubleshooting. If a defective part or unit should be returned, a Return Authorization Number must be issued by Nature Power and the defective part or unit should be returned to the authorized location at the purchasers’ expense. A dated proof of purchase is required to receive warranty service. Once received at authorized location and defect proves to be the result of defective material and workmanship, the defective part or unit will be replaced at warrantors’ option and returned to the original purchaser at warrantors’ expense. No refunds will be granted by the warrantor, in the event of buyer’s remorse please contact your point of purchase within and in adherence to their return policy. Refunds are granted at the retailers’ discretion.
Please contact Nature Power Products to acquire more
information:
1-800-588-0590
info@naturepowerproducts.com
www.naturepowerproducts.com
Made in Vietnam
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>