Honeywell HZ322 TrueZONE Panel User Guide

June 7, 2024
Honeywell

Honeywell logo

Honeywell HZ322 TrueZONE Panel

Honeywell-HZ322-TrueZONE-Panel-PRODUCT

Honeywell HZ322 TrueZONE Panel

SUBMITTAL SHEET

Job Name|
---|---
Engineer|
Mechanical Contractor|
Contractor’s P.O. No.|
Representative|
Notes|
Model(s)

HZ322| Qty.|  | Notes|

HZ322K (Kit
| Qty.|  | Notes|
Approval|
Service|
Tag No.|

APPLICATION

The HZ322 TrueZONE panel controls:

  • Conventional gas, oil, or electric forced-air systems up to 2 stages heat and 2 stages cool;
  • Heat pump systems with single-stage compressor and auxiliary heat;
  • 2 or 3 forced-air zones with wired thermostats, or wireless thermostats using an optional wireless adaptor.

FEATURES

  • Intuitive installer setup with easy-to-follow, digital the display uses real language to guide the installer through configuration
  • Universal application for any HVAC system using conventional thermostat wiring (R W Y G C etc.)
  • Standard checkout procedure ensures correct operation before leaving the job
  • Robust push terminals for up to two wires per terminal
  • Common-sense LEDs indicate the stage of heat and damper state
  • Control of two or three-wire dampers with open or closed logic
  • Variable-speed fan control lowers fan speed when one zone is calling for cooling
  • Discharge air temperature down-stages equipment when near high or low limit

Honeywell HZ322 TrueZONE Panel - 1

SPECIFICATIONS

Input Ratings:
Voltage: 18-30 VAC 50/60 Hz powered by a transformer of 40 VA or more
Current Draw:
Zone Panel: 7.5 VA max. All VA specifications at 24 VAC.
Wiring: 18- or 20-gauge solid (not stranded) wire
Humidity Ratings: 5 % to 90 % RH non-condensing
Temperature Ratings:
Shipping: -20° to 150 °F (-29° to 66 °C)
Operating: -40° to 165 °F (-40° to 74 °C)
Dimensions: See Fig. 1.
Mounting:
Mounts with either 2 screws at the centerline to mount onto 2x 4, or with 4 screws at corners for a wall mount.
Recommended Thermostats: See Table 1.
Recommended Dampers: See Tables 2 and 3.
For a maximum number of dampers per zone see Table 4.
Accessories:
See Table 5.
Emissions:
Complies with FCC Class B, part 15 requirements.

Honeywell HZ322 TrueZONE Panel - SPECIFICATIONS

Fig. 1. HZ322 TrueZONE panel dimensions in in. (mm).

Table 1. Recommended thermostats.

RedLINK thermostats:

TH8110R1008 (wired or wireless) Single-stage heat and cooling. No IAQ.
TH8320R1003 (wired or wireless
) 2H/2C heat pump without aux, 2H/1C with AUX or 2H/2C conventional. No IAQ.
TH8321R1001 (wired or wireless) 2H/2C heat pump without aux, 2H/1C with AUX or 2H/2C conventional. Hum, Dehum, or Vent control when used as wired thermostat, or wireless to a THM5421R1021 EIM. EIM wired to one of the zones.
THX9421R5021 Prestige (2-wire R and C. Wireless to THM4000R/HZ322 or THM5421R1021 EIM.
) 2H/2C heat pump without aux, 2H/1C with AUX or 2H/2C conventional. Hum, Dehum, and Vent control when used with THM5421R1021 EIM. EIM wired to one of the zones.
TH6320R1004 programmable FocusPRO (wireless) 2H/2C heat pump without aux, 2H/1C with AUX or 2H/2C conventional. No IAQ.
TH5320R1002 non-programmable FocusPRO (wireless
) 2H/2C heat pump without aux, 2H/1C with AUX or 2H/2C conventional. No IAQ.
Wired thermostat
Battery-powered, hard-wired, or mechanical| The HZ322 is compatible with most standard thermostats. The HZ322 allows you to choose stage 2 (and stage 3) control to be by thermostat, timer, or % of zones. If you want the thermostats to control staging, multi-stage thermostats are required.
Power stealing or phantom voltage (Lyric round, etc.)| We do not recommend using thermostats that operate on phantom voltage or power-stealing mode with the HZ322. Some of these models have an optional C wire. Models tested with a C wire worked correctly with the HZ322.

  • RedLINK models without IAQ control need a THM4000R1000 wireless adaptor. One adaptor can be used for up to 3 RedLINK thermostats on HZ322. If IAQ control is required from the TH8321R1001 or THX9421R5021 model, a THM5421R1021 is required for the thermostat controlling IAQ equipment. That EIM wires to one of the zones on the HZ322.

Table 2. Recommended residential dampers.

Type Actuation Round Rectangular
Zone Spring-open/power-closed ARD ZD
Power-open/power-closed RRD
Bypass Barometric CPRD None

Table 3. Recommended commercial dampers.

Type Actuation Round Rectangular
Zone Power-open/power-closed MARD D2 with ML6161A2009*
Bypass Power-open/power-closed MARD with SPC D2 with ML6161A2009* and SPC

*Or equivalent damper and actuator.

**Table 4. Maximum dampers***

Ambient Temp. Maximum Damper VA per Zone
100°F (38°C) 28.8
160°F (71°C) 16.8
  • Use an SDCR (Secondary Damper Control Relay) for additional dampers.
    •Maximum dampers per panel is limited by transformer size.
    •Ensure the transformer is large enough to power the panel (7.5 VA) and dampers.

Table 5. Accessories.

Description Part Number
40 VA transformer AT140A1042*
75 VA transformer AT175A1008
Discharge air temperature sensor (DATS) C7735A1000*
Outdoor Air Sensor (wired) C7089U1006
Outdoor Air Sensor (wired) C7089R1013 (THM4000R1000 wireless adaptor

required)
Wireless adaptor| THM4000R1000
Secondary damper control relay| SDCR
*Included in HZ322K kit.

Resideo Technologies, Inc.
1985 Douglas Drive North, Golden Valley, MN 55422
1-800-468-1502
68-3072—03 M.S. Rev. 06-21 | Printed in the United States

www.resideo.com

© 2021 Resideo Technologies, Inc. All rights reserved.
The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates.

DOWNLOAD RESOURCES

FAQ’S

Do I have to purchase a transformer?

Yes. The HZ322 does not come with a transformer.

Can I use the HZ322 with a 24 VAC system?

No. The HZ322 will only work on systems that are 18-30 VAC.

What does a Honeywell HZ322 do?

The TrueZONE® HZ322 Panel is for conventional and heat pump applications up to 3 zones (2H, 2C) at 24 Volts. It features robust push terminals, common-sense LEDs, variable-speed fan control, and leaves a smaller environmental footprint.

What does a TrueZONE damper do?

The TrueZONE® Bypass constant pressure regulating damper (CPRD) is a round static pressure relief damper. It is used in forced-air bypass applications to relieve excess static pressure when some of the zone dampers are closed.

What can cause a Honeywell thermostat to stop working?

What can cause a Honeywell thermostat to stop working?
Put in new batteries; Check the circuit breaker; Check the indoor unit to make sure all the panel doors are closed; Make sure the power is connected to the furnace or air conditioning unit by checking the switch near the indoor unit is up.

How do I reset my Honeywell thermostat that won’t turn on?

Resetting a Honeywell Thermostat
Power off the thermostat and remove the batteries.
Put the batteries in the wrong way, with negative to positive and positive to negative.
Wait ten seconds and put them back in the correct way.
Your thermostat will be reset to factory settings.

What to do when the thermostat goes blank?

If your thermostat is blank, the first thing you should do is check the batteries. Chances are, the batteries have died and the thermostat simply can’t power on. Replace the batteries and see if your thermostat turns on.

What does red light mean on Honeywell HZ322?

I had one of these units in a two story house, and the red LED means that zone is closed, a green light means that it is open. So, for the panel on the left, the system is calling for heat, and only the Zone 3 damper is open (so the Zone 3 thermostat is the one calling for stage 1 heat.

What are the signs of a thermostat not working?

High-temperature readings
The main symptoms of a failing thermostat are related to engine overheating. It can be easily noticed because the temperature gauge in the vehicle will probably read unusually high. This can be caused by the valves being stuck in a closed position.

How do I connect my Honeywell sensor?

Now remove the sensor cover and insert batteries. Then tap next then press the connect button on the sensor. Your unit will then search for the sensor.

How do you check a thermostat if it’s working?

Check the screen: Check the screen of the thermostat and make sure that it is lit. A blank or unlighted screen could indicate a thermostat failure. Check the batteries: Many modern thermostats rely on battery power to operate. If the screen is blank or unlighted, a battery change could solve the problem.

How do you activate a sensor?

The Activate Sensor Behavior (deactivate sensor) enables the Sensor on an Entity for as long as the behavior is active. To use an Activate Sensor Behavior a Perception Locator must be mapped to the Crowd Field (directly or through the Crowd Manager Node). Sensors don’t have any visible effect on the Crowd simulation.

Honeywell logo

Honeywell HZ322 TrueZONE Panel
https://www.honeywellhome.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Honeywell User Manuals

Related Manuals