CHAMPION 8000W Electric Start Dual Fuel Generator User Guide

June 7, 2024
Champion

CHAMPION 8000W Electric Start Dual Fuel Generator User Guide
CHAMPION 8000W Electric Start Dual Fuel Generator

Warning IconWARNING

Read the ENTIRE operator’s manual to become familiar with the features of the product before operating.
Failure to operate the product correctly can result in damage to the product, personal property and cause serious injury or even death.

Set Up / Montage

1. Open shipping carton. Assembly > Unpacking
Opening Carton

2. Attach wheel kit. Assembly > Install Wheel Kit
Attach Wheel Kit

3. Connect the battery. ****Assembly > Connect the Battery.
Cut cable tie on each side of battery connector.
Push two halves of battery connector together tightly.

Connect to Battery

4. Add oil. ****Assembly > Add Engine Oil.
Recommended: 5W-30, up to 37.2 fl. oz. (1100 ml) DO NOT overfill.
Add Oil

Start Up

5. Move the generator outdoors.
Move generator to an open, outdoor area. Point exhaust away. Never run generator in enclosed areas (e.g., not in house or garage).
Moving Generator Outdoor

Keep all objects at least 5 feet (1.5 m) from generator. Heat from the muffler and exhaust gas can ignite combustible materials.

Keep Away

6. Add fuel – Gasoline or Propane (LPG) ****Assembly > Add Fuel
Add Gasoline

Warning Icon FOR GASOLINE OPERATION :
DO NOT USE E15 OR E85

7. DO NOT plug in any electrical devices.
Don not Plug In
Warning Icon NEVER START OR STOP THE GENERATOR WITH
ELECTRICAL DEVICES CONNECTED OR TURNED ON!

8. Select Fuel. **Operation > Starting the Engine.
Gasoline: Turn fuel select dial to “GASOLINE RUN” position.
Propane: Turn fuel select dial to “PROPANE RUN” position.
Select Fuel
9. Move the
choke lever** to the “CHOKE” position.

Start Up

Starting the Engine GasolineStarting the Engine: Gasoline

10a. Electric Start

  1. Press and hold the ignition switch to the “START” position.
  2. Move the choke lever to the “RUN” position.
    Ignition SwitchChoke
Lever

Manual Start

  1. Pull the starter cord.
  2. Move the choke lever to the “RUN” position.
    Choke Lever

Engine Starting IconStarting the Engine: Propane (LPG)

10b. Electric Start

  1. Press and hold the ignition switch to the “START” position.
  2. Move the choke lever to the “RUN” position.
    Ignition SwitchChoke
Lever

Manual Start

  1. Pull the starter cord 2-3 times to prime the engine.
  2. Move the choke lever to the “RUN” position.
  3. Pull the starter cord to start the engine.
    Choke Lever

11. Plug in. ****Operation > Connecting Electrical Loads.

Plug In

Contac Us: 1•877•338•0999

CHAMPIONPOWEREQUIPMENT.COM

Documents / Resources

| CHAMPION 8000W Electric Start Dual Fuel Generator [pdf] User Guide
8000W Electric Start Dual Fuel Generator, 201078
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Champion User Manuals

Related Manuals