Altronix eBridge16CR 16 Port IP Over Coax Receiver Installation Guide
- June 4, 2024
- Altronix
Table of Contents
eBridge16CR
Sixteen (16) Port IP over Coax Receiver
Installation Guide
Rev. 072412
Installing Company: ___ Service Rep. Name: ____
Address: ____ Phone #: __
Overview:
Altronix eBridge16CR is a CAT5 to Coax cable Ethernet receiver. The receiver enables fast 10/100Base-T Ethernet digital communication to be received over Coax cable. This plug and play unit facilitates system upgrades from analog to IP cameras/devices utilizing existing legacy Coax and eliminating the costs and labor associated with installing new network cabling. In addition, data transmission over the Coax can be extended to 500m (five times the 100m Ethernet maximum length), eliminating the need for repeaters. At the same time the unit can combine Composite Video Signal with the Ethernet data enabling connection to an analog input on a monitor or matrix switch. The eBridge16CR is to be used with a compatible Hybrid camera with “sloc” technology. An eBridge1CT is required for other IP cameras/devices.
Features:
Agency Listings:
- UL 60950-1 Information Technology Equipment.
- CE European Conformity.
- Compliant: Incorporates *sloc TM (Security Link over Coax) technology.
Input:
- 24VDC to 56VDC UL Listed Class 2 power supply (polarity not observed) or UL Listed 24VAC Class 2 plug-in transformer.
Power Consumption:
- 24VDC/1500mA, 56VDC/700mA, 24VAC/2000mA.
Ethernet:
- Connectivity: RJ45, auto-crossover.
- Wire type: 4-pair Cat-5 or better-structured cable.
- Distance: up to 100m.
- Speed: 10/100BaseT, half/full duplex, auto negotiation.
- Throughput is rated to pass 25Mbps of data at distances up to 500m. With proper headend equipment multiple Megapixel cameras can be used.
Coax:
-
Distance: up to 500m.
-
Connectivity: BNC, RG-59/U or similar.
-
sloc is a registered trademark of Intersil Corporation.
LED Indicators:
- Blue LED: Coax link connection.
- Yellow and Green LED (RJ45): IP Link status, 10/100Base-T/active.
- Green LED: Power.
Environmental:
- Operating Temperature:
- 10ºC to 50ºC (14ºF to 122ºF).
- Storage Temperature:
- 30º to 70ºC (– 22º to 158ºF).
- Humidity: 20 to 85%, non-condensing.
Applications:
- Retrofit digital IP cameras in an analog CCTV installation.
- Works with Megapixel, HD720, HD1080 and VGA (SD) cameras (see note, pg. 2).
- Extend Network link distance in an industrial environment.
- Upgrade deployed CCTV Coax to a digital network in Retail, Hospitality, Arenas, Casinos, Airports, Schools, Hospitals, Transportation, etc.
- Enables simultaneous transmission of composite and digital IP video.
Mechanical:
- Dimensions (H x W x D approx.): 1.625” x 19.125” x 8.5” (42mm x 486mm x 216mm)
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA
70/ANSI, and with all local codes and authorities having jurisdiction. Wiring
should be UL Listed and/or Recognized wire suitable for the application.
eBridge16CR is not intended to be connected to outside plant leads and should
be installed indoors within the protected premises. The eBridge16CR is
intended for indoor use only. This product is intended to be supplied by a UL
Listed Direct Plug-in Power Unit marked “Class 2” and rated from 24VDC to
56VDC or 24VAC, 2000mA.
Elevated Operating Ambient – If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be
greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum ambient
temperature (Tma) specified by the manufacturer.
Reduced Air Flow – Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is
not compromised
Mechanical Loading – Mounting of the equipment in the rack should be such
that a hazardous condition is not achieved due to uneven mechanical loading.
Circuit Overloading – Consideration should be given to the connection of
the equipment to supply circuit and the effect that overloading of the
circuits might have on overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate rating should be used when addressing
this concern.
Reliable Earthing – Reliable earthing of rack-mounted equipment should be
maintained. Particular attention should be given to supply connections other
than direct connections to the branch circuit (e.g. use of power strips).
-
Attach mounting brackets to eBridge16CR unit for rack installation (Fig. 7, pg. 11).
Affix rubber pads to eBridge16CR for shelf installation (Fig. 8, pg. 11). -
Unit should be located in proximity to ethernet switch/network, NVR or video server.
-
Connect UL Listed 24VAC Class 2 plug-in transformer or 24VDC/56VDC (polarity not observed) UL
Listed Class 2 power supply to jack marked [Power Input] using two pin plug in connector (supplied) (Fig. 1, pg. 5). Use 22AWG-16AWG wire for this connection. -
Connect structured cable from ethernet switch/NVR (network video server) to RJ45 jack marked [10/100BaseT] (Fig. 1, pg. 5).
-
Connect Coax cable to BNC connector marked [Data In] (Fig. 1, pg. 5).
-
For optional simultaneous Composite Video transmission, connect Coax cable to BNC connector marked [Composite Video Out] (Fig. 2, pg. 6). Connect the other end of the Coax cable to the composite video input of the NVR, monitor display, matrix switch or other headend equipment.
Note: eBridge16CR is designed to accommodate Megapixel, HD720, HD1080 and VGA (SD) cameras. It is important to note that some high resolution and high frame rate cameras may demand faster headend processing ability, such as a PC graphics card to present a quality image. If the headend processing equipment is insufficient in speed, the image may show pixilation and latency. It is advisable to pretest system if unsure. Alternatively, frame rate and resolution may be reduced to accommodate system equipment.
Technical Specifications:
Parameter | Description |
---|---|
Connections | BNC for Coax link. RJ45 for ethernet link. |
Composite video connector for optional composite video service
Input Power Requirements| 24VDC/1500mA, 56VDC/700mA, 24VAC/2000mA.
Indicators| Blue: Coax Link.
Yellow (RJ45 connector): On – Link, Off – No Link, Blinking – Activity.
Green (RJ45 connector): On – 100Base-TX, Off – 10Base-T.
Green: Power.
Environmental Conditions| Operating Ambient Temperature (UL60950-1): —
10°C to 50°C (14°F to 122°F).
Relative humidity: 85%, +/— 5%.
Storage Temperature: — 30°C to 70°C (— 22°F to 158°F).
Operating Altitude: — 304.8 to 2,000m.
Regulatory Compliance| UL/cUL Listed for Information Technology
Equipment (UL 60950-1).
CE European Conformity.
Weights (approx.)| Product: 7.2 lb. (3.27 kg) I Shipping: 9.2 lb. (4.17
kg)
Single IP Camera Shown with Composite Video Option:
Solutions and Installation Notes:
Currently, Matrix Switchers, DVRs, and NVRs do not readily accommodate multi- picture (Matrix) monitor display capability (typically 4X4 16 channel display) for some of the higher resolution cameras. In addition, HD cameras use a widescreen format (16:9 aspect ratio). This may not fit as well into the matrix display as the standard screen format (4:3 aspect ratio). In addition, high-resolution multichannel recording can introduce unacceptable latency in the real-time monitor display. To achieve high-resolution recording along with real-time multi-channel viewing: Record the high-resolution IP video via the NVR and the simultaneous composite video via the Matrix switcher to achieve proper display format (Fig. 4, pg. 8).
Multiple IP Cameras Shown with Composite Video Option:
Multiple IP Cameras Over a Single Coax:
*Note: Multiple cameras require higher bandwidth and headend equipment processing speed. It is advised to test this configuration. eBridge is rated to pass 25Mbps of data at distances up to 500m. With proper headend equipment multiple Megapixel cameras can be used.
eBridge16CR Rack Mount Chassis Mechanical Drawing and Dimensions (H x W x
D approx.):
1.625″ x 19.125″ x 8.5″ (42mm x 486mm x 216mm)
Mounting Options:
Rack Mount Installation
- Remove and discard factory installed screws from both sides of rack chassis (Fig. 4a).
- Install mounting brackets (A) on the left and right side of rack chassis using the four (4) flat head screws (B) (included) (Fig. 4b).
- Place unit into desired EIA 19″ rack position and secure with mounting screws (not included) (Fig. 4c).
Wall Mount Installation
- Install mounting brackets (A) on the left and right side of rack chassis using four (4) flat head screws (B) (included) (Fig. 5a).
- Place unit at desired location and secure with #6 size screws or larger (not included) (Fig. 5b).
Caution: It is necessary to make sure mounting screws are securely fastened to a beam when installing the unit vertically.
Shelf Installation
- Position and affix rubber pads (C) (included) at each corner on the bottom of the unit (Fig. 6).
- Place unit in desired location.
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA |
718-567-8181 |
fax: 718-567-9056
website: www.altronix.com
e-mail: info@altronix.com
Lifetime Warranty
IIeBridge16CR G19U
eBridge16CR Installation Guide
Read User Manual Online (PDF format)