Installation Guide
20/40/60 Minute Ventilation and Filtration Timer
- Ventilation and filtration control fromany location.
- Works with any RedLINK® 2.0 thermostat.
- Does not require a ventilator to boost filtration.
Install Battery
- Remove the cover.
- Insert the CR2450 coin cell battery (included) into the slot at the bottom of the remote. See polarity marking on the remote.
- The LED will briefly flash green.
When battery power is low, the LED will flash red.
Mounting
Mounting the remote is optional.
- Remove the front cover from the remote.
- Use provided screws and wall anchors to fasten the remote to the wall.
- lternatively, use double sided tape to fasten the remote to the wall.
- Replace the cover on the remote.
Connect
- Prepare the thermostat for RedLINK connection (see the thermostat or EIM instructions).
- Press and release the CONNECT button on the remote. After a short delay, the LED will glow green for 15 seconds.
LED Operation
During normal operation the LED will be off when the remote is idle. If the LED remains off when a button is pressed then the battery has failed
After a button press the LED will function as follows:
- Green when a button is pressed.
- Quickly flashing red when the battery needs to be replaced.
- Slowly flashing amber when the remote is disconnected from the system.
- The LED will be off when the remote is idle.
During wireless connection to the system the LED will function as follows:
- Solid green for 15 seconds: connected to the system.
- Solid red: the remote did not connect to the system.
Disconnect from RedLINK System
Press and hold the CONNECT button on the remote until the LED glows amber (about 10 seconds) to disconnect from the RedLINK system.
If you replace a thermostat or Equipment Interface Module, disconnect the remote from the old device. Then follow the steps on page 1 to re-connect the remote to the wireless network.
Setting up Ventilation and Filtration Boost at the Thermostat
Ventilation and Filtration Boost
Wire ventilator and choose the type of ventilation in Installer Set Up of the
thermostat. Filtration will be boosted with ventilation if the system is set
up to run the fan with ventilation
Filtration Boost without a Ventilator
Choose passive ventilation (fan only) for the ventilation type in Installer
Set Up of the thermostat. When the remote button is pressed the equipment fan
will circulate air through the filter.
Operation
The Wireless Vent and Filter Boost Remote provides onetouch control of the ventilation and filtration systems.
The remote has three buttons: 20, 40, and 60 minutes. The ventilation and
filtration can be temporarily boosted for 20,
40, or 60 minutes, depending on the button pressed.
Pressing one of these buttons temporarily boosts the ventilation and filtration for either the time on the button or the current run time at the thermostat, whichever is greater.Vent boost can be cancelled from the thermostat.
Specifications
-
Operating Ambient Temperature
35 to 114° F (1.7 to 45.6° C) -
Operating Relative Humidity
5% to 90% (non-condensing) -
Physical Dimensions (height, width, depth)
2-7/8 x 1-7/8 x 15/16 inches (74 x 48 x 24 mm
Input: 3 V
This device contains a Lithium battery which may contain Perchlorate material.
Special handling may be required.
See
www.dtsc.ca.gov/hazardouswaste/perchlorate.
Regulatory information
FCC Compliance Statement (Part 15.19) (USA only)
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
FCC Warning (Part 15.21) (USA only)
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
FCC Interference Statement (Part 15.105 (b)) (USA only)
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is
encouraged to try to correct the interference by one of the following
measures:
- aged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Equipment interface module, thermostats and indoor sensor
To comply with FCC and Industry Canada RF exposure limits for general
population/ uncontrolled exposure, the antenna(s) used for these transmitters
must be installed to provide a separation distance of at least 20 cm from all
persons and must not be co-located or operating in conjunction with any other
antenna or transmitter.
Section 7.1.2 of RSS-GEN
Under Industry Canada regulations, this radio transmitter may only operate
using an antenna of type and maximum (or lesser) gain approved for the
transmitter by Industry Canada. To reduce potential radio interference to
other users, the antenna type and its gain should be so chosen that the
equivalent isotropically radiated power (e.i.r.p.) is not more than that
necessary for successful communication.
Section 7.1.3 of RSS-GEN
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device
The operation of this equipment is subject to the following two conditions: (1) this equipment or device may not cause harmful interference, and (2) this equipment or device must accept any interference, including interference that may cause undesired operation.
Need Help?
For assistance please visit http://customer.resideo.com,
or call toll-free: 1-800-468-1502
References
- Resideo Customer Portal
- dtsc.ca.gov/hazardouswaste/perchlorate
- Smart Home Solutions in EMEA | Resideo
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>