UVPLUS UVP101R Intelligent UV & Ozone Disinfection Box Instruction Manual
- June 7, 2024
- UVPLUS
Table of Contents
Intelligent UV & OZONE Disinfection Box ULTIMATE
UVP101R
UVC Light germicidal system intends for use in general-purpose
2-year warranty
Product Features:
- The double-effect disinfection combination, fully reflect the high efficiency of ULTRAVIOLET disinfection and 360° no the blind angle of OZONE disinfection.
- A multi-purpose box can meet the user demands of the whole family along with realizing the classified disinfection and mobile disinfection.
- The metal deposition in the disinfection box can strengthen the reflection efficiency and realize 360° all-round disinfection without blind angle.
- The inside of the disinfection box is equipped with an interlayer, which can increase the disinfection area to the backside of articles after the ultraviolet is reflected from the inner bottom of the box.
- The design of Hall Switch for the disinfection box, opening the box will automatically stop the disinfection work, which can effectively avoid the damage of ultraviolet or ozone to the human body.
- During the hand-held use, the REV-ODS intelligent Reverse Obstacle Detection System will start automatically. If detecting the distance between the light source of the disinfection light head and the surface of articles to be disinfected exceeds 2cm, it will automatically stop the disinfection work, and reach the safe energy-efficient effects.
- In case of disinfecting the surface of articles by independently hand-held use, it is usually able to kill 99.9% bacteria and viruses on the surface or articles within 3 to 5 seconds.
- With the intelligent button operation interface, it is able to independently select and adjust the disinfection mode and disinfection time.
- The color LCD screen can display the information e.g. disinfection mode, disinfection time and state of charge, etc. in real-time.
- UVP101R has a memory function. After starting the machine each time, the screen will display the mode and time of disinfection work for the last time.
- Type-C charging, portable and durable.
Schematic Diagram of Product:
Operation Instruction:
- After starting the machine, please select language: short press ” ****“to select English
- Long press both of ” ” and ” ” for more than 5 seconds, the unit will automatically switch off and reset the language selection, you can reselect language in the next use
The disinfection lamp cap is fixed with an upper cover of the box and lower Box (Mode 1). (ULTRAVIOLET mode or OZONE mode are optional for disinfection)
- Long press ” ****” for 1.5 seconds to start the machine, the screen displays “Double-click start/stop disinfection” for 5 seconds. If not performing any operation after starting the machine, it will automatically switch off after 30 seconds for energy conservation and environmental protection.
- The screen displays “Fixed use” to indicate the installation for disinfection lamp, upper and lower box of the box is completed; If them is any separation between disinfection lamp cap, upper cover of the box and a lower box of the box, and then the screen will display “Handheld use”.
- Short or long-press ” ****” to select “03 60 min” or “03 120 min” mode.
- Short or long-press ” ****” to select “UVC 5 min”, “UVC 10 min” or “UVC 30 min” mode.
- After selecting the disinfection mode, double-click “ ****” to start disinfection, the screen displays “Disinfecting…”.
- In case of any separation between disinfection lamp cap, upper cover of the box, and lower cover of the box in the course of disinfection, it will automatically stop the disinfection work, and the time will return to the preset time.
- In the progress of disinfection, double-click ” ****” to stop working, and time will return to the preset
- Long press ” ****” during the disinfection to switch off the machine.
- Short presses any button during the disinfection will not be effective.
- It will automatically stop the ozone work in the last 10 minutes of preset time in the course of ozone disinfection and activate the ultraviolet automatically to perform 10-minute ozonolysis.
- If the battery level is lower than 20% and the battery level displays in red ” ****“, it is required to charge as soon as possible to avoid that the remaining battery power is insufficient to finish one complete disinfection.
- If the screen displays “Disinfection finished” and time displays the green number 0, it indicates the disinfection work is completed.
- After the disinfection work is completed, it will automatically switch off after 30 seconds if not performing any operation for the energy conservation and environment protection.
- The disinfection lamp cap has the memory function: After starting the machine each time, the screen will display the mode and preset time of disinfection work for the last time.
Separate hand-held operation for disinfection lamp cap (Mode 2). (Only ULTRAVIOLET disinfection mode)
- Long press ” ****” for 1.5 seconds to start the machine, the screen displays “Double-click start / stop disinfection” for 5 seconds. If not performing any operation after starting the machine, it will automatically switch off after 2 minutes for energy conservation and environmental protection.
- In the preset mode’s “UVC 60 min”, double-click ” ****” to start disinfection.
- The intelligent REV-ODS system will start automatically during the disinfection
- If the REV-ODS system doesn’t detect the articles to be disinfected, the screen will display “Please move closer”, and the unit will automatically stop the disinfection work, It will automatically switch off after 2 minutes for the energy conservation and environment protection
- If the REV-ODS system detects the articles to be disinfected, the unit will automatically resume the disinfection work, and the screen will display “Disinfecting…”, and the unit will continue the previous work for time countdown
- In the progress of disinfection, double-click ” ****” to stop working, and time will return to the present time “60 min”.
- Long press ” ****” during the disinfection to switch off the machine.
- Short presses any button during the disinfection will not be effective.
- If the screen displays “Disinfection finished” and time displays the green number 0, it indicates the disinfection work is completed.
- After the disinfection work is completed, it will automatically switch off after 30 seconds if not performing any operation for energy conservation and environment protection.
Suggested Time For Disinfection Articles (Mode-1, disinfection lamp cap is fixed with an upper cover of the box and lower box):
- Time suggestion for ultraviolet disinfection:
- As for the ordinary small-sized articles, such as mobile phone, watch, pen, key chain, etc., it is suggested to disinfect for 5 minutes
- As for the ordinary middle-sized articles, such as masks, milk bottles,s, etc., it is suggested to disinfect for 10 minutes
- As for the professional article disinfection, it is suggested to appropriately extend the disinfection time
- Time suggestion for ozone disinfection:
- As for the ordinary article disinfection, it is suggested to disinfect for 60 minutes
- As for the professional article disinfection, it is suggested to appropriately extend the disinfection time
SAFETY WARNING:
- Please read and understand this user manual before use, to ensure that the product is safely and properly used
- Our Company shall not be liable for product damage and other injuries caused by improper use or failure to follow this User Manual.
- Strictly forbid any children 0-12 years old to use this product. Users should carefully select places without children before use and ensure that children do not touch the product.
- Avoid the risk of electric shock during use.
- The use of this product in gas, flammable and explosive substances and heat source environments is
- Don’t use wet hands in operating the product. Please keep the operating environment dry
- Do not remove, repair, and alter the product by oneself. Repairs and battery replacements can only be carried out by authorized service providers and manufacturers, and repair and replacement of batteries by authorized service providers and personnel other than manufacturers may result in injury. Replacing the battery with the wrong model is a risk of explosion
- Use the product only at specified voltages and frequencies
- UV Light Hazard. Harmful to bare skin and eyes. Can cause temporary or permanent loss of vision. Never look at the bulbs while illuminated. Any exposed skin must not be exposed to UV light
CAUTION:
UVC-Equipment Damage Hazard.
- Ultraviolet light can cause color shift or structural degradation of plastic materials
- Ultraviolet light can cause color shift or structural degradation of resin materials
- Ultraviolet light can cause color shift or structural degradation of leatherwear
- Ultraviolet light can cause color shift or structural degradation of organic compounds materials
OZONE-Equipment Damage Hazard.
- OZONE can cause color shift or structural degradation of plastic materials
- OZONE can cause color shift or structural degradation of resin materials
- OZONE can cause color shift or structural degradation of leatherwear
- OZONE can cause color shift or structural degradation of organic compounds materials
- High concentrations of ozone for a long time can cause electronic products to function damage
NOTES:
- The design of this product is based on IEC 62471:2006 Photobiological safety of lamps and lamp systems and other international standards
- This product utilizes the ultraviolet rays LED, which emits UV-C rays with a peak value wavelength at 275nm to disinfect
- Ultraviolet LED is a relatively tight and fragile electronic component, users should avoid the impact on the product resulting in product failure.
- The design of this product is according to Code of Federal Regulations Title 21, Volume 8 by US FDA, California Code of Regulations Title 17 Public Health, and IEC 62368-1[4] 7.3 and other international standards
- According to the code of federal Regulations Title 21, Volume 8, ozone is a toxic gas, according to FDA. Although ozone has been reported to have adverse physiological effects on the central nervous system, heart, and vision, its main physiological effect is to stimulate the mucous membranes. Inhalation of ozone causes enough irritation to the lungs, leading to pulmonary edema. The onset of pulmonary edema is usually delayed by several hours after exposure; As the hazards of ozone are widely understood, people pay full attention to the use of ozone.
- At Ozone concentrations of 0.02PPM (0.04mg/m3), ozone can be smelled by people with acute olfactory senses, at 0.15PPM (0.32mg/m3), ozone can be smelled by the general population, at 1-10PPM (2.14 -4mg/m3) ozone has reached the “stimulus range”, and can be clearly smelled, at 1OPPM (21.4mg/m3) ozone has reached the ‘toxic range’ or more “poisonous range’. The odor of ozone is not a reliable warning indicator due to the possibility of olfactory fatigue
- Long-term occupied enclosed spaces, such as houses, apartments, hospitals, and offices, should have ozone volumes below 0.1mg/m3 (0.05PPM). The ozone concentration in the workplace, i.e. occupational exposure limit, is 0.1PPM
- The amount of space used by the equipment used to place and use this device should not be less than 20m3 to ensure that the ozone remaining in the equipment has sufficient space to be decomposed to a safe level when the cabinet door is opened
- When opening the equipment for ozone disinfection, make sure that the equipment is in a well-ventilated environment. If the equipment cannot be ensured to be in a well-ventilated environment, only open the cabinet door at least 30 minutes after an ozone disinfection session has finished
- Ozone is unstable, breaks down rapidly at high temperatures, slowly breaks down to (oxygen) at room temperature, has a half-life of about 16 minutes in 1% of ozone solution and about 25 minutes in the air.
- Pure ozone, if receives impact or friction, will explode and decompose. High concentrations of ozone when heated are also prone to explosion. But as long as care is taken, such accidents are rather rare. Ozone should not have high concentrations of flammable and explosive gases at the disinfection site when it is used for air disinfection.
- The user uses a 3M8514 welding protection mask (or equal grade protection masks) when using ozone to disinfect, and can process ozone protection which at 10 times occupation touch limit potency under 1PPM
- This product set enough safety device to guarantee the safety of users. The daily item to item check is the necessary condition to guarantee that safe uses the equipment. Please process item to item check according to the requirements in the specification, need stop use the equipment immediately once found the problem.
- Because of the instability of ozone, ultraviolet light accelerates the decomposition of ozone and converts it back to oxygen. ARer the ozone work is completed, the equipment switches to UV mode to quickly reduce the ozone concentration in the equipment. The user must never open the cabinet doors before the device has completed the ozone disinfection operation (before the end of the timer countdown in the monitor)
- Users are advised to equip users with ozone concentration detection instruments to regularly detect whether the leaked ozone value of the equipment exceeds the safe value: long term populated enclosed spaces, such as houses, apartments, hospitals and offices, ozone must be less than 0.1PPM in If ozone leakage value is found to have exceeded the above standard, the equipment must be immediately stopped.
To guarantee the disinfect effect of UVC:
- Whether UV light can effectively disinfect depends on the amount of exposure received by the disinfection object, which depends on the radiation power of the UV light source, the distance of the disinfection object from the UV light source, and the duration of the exposure to UV light.
- When killing common microorganisms, the irradiated dose should reach 10,000 pW/cm2; 100,000 p W/cm2 is the recommended dose to kill bacterial spores. The radiation dose should not be less than 100,000 pW/cm2 when the target microorganism for disinfection is unknown.
- According to the radiation intensity of the UV light source of this product and the general distance of the UV light source from the irradiated object, it is recommended that:
- In order to achieve the radiation dose of 10,000 pW/cm2 to meet the general needs of daily use, the exposure time should be at least above 60 seconds
- In order to achieve the radiation dose of 100,000 pW/cm2 to meet the needs of the professional environment, the exposure time should be at least above 500 seconds
To guarantee the ozone disinfect effect:
- Ozone can kill bacterial reproductions, viruses, fungi, etc., and can destroy botulinum toxin. In order for ozone to be effective as a disinfectant, its concentration must be much higher than that that can be safely tolerated by humans and animals. Ozone has a powerful killing effect on microorganisms in the air, and at the same time has odor-removal characteristics, 30minutes of 20mg/m3 (9.35PPM) concentration of ozone in sealed environments can achieve disinfection effect. Ozone on the surface of the items of the microorganism also has a killing effect, requiring 60mg/m3(28.04PPM), relative humidity of 70%, and exposure of 60 minutes to 120 minutes, to achieve disinfection effect.
- If the equipment is stopped in the middle of the operation, the disinfection effect cannot be guaranteed, a new disinfection session from the start will be necessary.
The reminding of damage about the disinfect objects:
- The effects of ozone on a variety of substances vary considerably Glass, stainless steel, butyl rubber, silicone, polycarbonate, and ABS plastics are better at ozone resistance, but Von, zinc, glass-fiber-added plastics, and natural materials such as natural rubber and leather, are less resistant to
- In order to ensure the service life, this product is designed with ozone-resistant materials.
- In order to examine the accelerated aging effect of ozone on substances, the substance was tested for 60 minutes at a time using ozone concentrations of 35PPM.
- Acer 10 tests of six different leather material colors samples, the results show color fading and hardening of the material, especially the brighter samples whose fading was more pronounced
- The same conditions were tested on stainless steel, aluminum, gold-plated PIN needles, silicone, cotton pads, cotton, and ABS plastics, and no significant decomposition was found
- It is recommended to avoid ozone disinfection of brightly colored leather, silk, and other items. Some highly aged items, such as natural rubber, are also recommended to not undergo ozone disinfection. Since ozone has an oxidative effect on most metals, users should not use ozone disinfection on electronic products to avoid ozone damage to devices containing metal substances, such as circuit boards in electronic products.
Equipment maintenance, please contact professional after-sales service stores or professionals
WARNING HARMFUL OZONE may be created by this product.
Follow installation and operating instructions.
WARNING UV-C emitted from this product.
Avoid eye and skin exposure to unshielded products.
Follow installation instructions and user manual.
AEC Lighting Solutions Co., Ltd
Add.: 2548 Bao’an Highway, Jiading District, Shanghai 201801, China
Tel.: 400-083-8757
www.aeclight-reel.com
References
- ALS | Advanced Lighting Systems & Products
- UVPLUS | 360° Disinfection & Sterilization Systems & Products
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>